}

Tender For Improvement And Development Of Ei And Fans Along With Provision Of Ups System At Lal Kuan Dispensary Under Ward No. 179 Pul Prahaladpur Under Cnz, Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Improvement And Development Of Ei And Fans Along With Provision Of Ups System At Lal Kuan Dispensary Under Ward No. 179 Pul Prahaladpur Under Cnz. Submission Date for this Tender is 04-08-2025. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

50475662
Tender For Improvement And Development Of Ei And Fans Along With Provision Of Ups System At Lal Kuan Dispensary Under Ward No. 179 Pul Prahaladpur Under Cnz
Tender
Indian
Delhi
Delhi
04-08-2025

Tender Documents

Tender Details

Improvement And Development Of Ei And Fans Along With Provision Of Ups System At Lal Kuan Dispensary Under Ward No. 179 Pul Prahaladpur Under Cnz; 1 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C 2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 5 Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. (a)5/6 amps switch 6 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 3 pin 5/6 A socket outlet 7 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 8 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 150 mm X 100 mm deep 9 Installation of exhaust fan in the existing opening ,including making good the damage ,connection,testing,commissioning etc.as required.(a) Up to 450 mm sweep 10 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door 11 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole 12 Supplying and fixing following rating ,double pole,240 volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.(b) 63 amps 13 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) 14 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm 15 Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required. 16 Supply of 1200 mm sweep 50 watt, Energy saver ISI Marked BEE 5 star rating AC Ceiling fan suitable for 230 V, Hertz AC supply without regulator with blades, download etc. complete as required. 17 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 18 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not riseabove 90°C).CRCA Sheet Body (Thickness ≥ 0.50 mm) , 18-22 WATT 19 SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color 20 Supply, installation testing and commission of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated, specially designed Al bus bar 400A to 630 A with heat shrinkable colour coded sleeves suitable for accommodating MCCBs/MCBs/Isolators as incoming and outgoing as required (without MCCBS/MCBS/Isolators) complete with digital meter Module, including voltmeter, Ammeter with selector switch, CTs control fuse and indicating lights including connections etc as required (conforms to IS:8623) 21 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB 22 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 A , 36 KA , TPMCCB 23 Repair/Rewinding of existing 1HP mono block pump set including replacement of parts like gun metal bush/ bearing condenser, impeller etc to make the pump functional as required. 24 SITC of single phase monoblock pump set complete with all accessories workable on 240/415Volts, 50Hz ac supply (a) 1 HP (0.75kw) single phasepump set , head from 12-30 meter suction amd delivery 25x25mm. 25 Supply of XLPE insulated PVC sheathed Al. Conductor Un-Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm 26 Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C x 10 sqmm 27 LED Flood Light, powder coated pressure die cast aluminum(System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light,powder coated pressure die cast aluminum body with built in or separatedriver as per the requirement with Driver efficiency >85%, Input voltage:Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 degto 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltageprotection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg., suitable tiltable fitting, life time (LED,Driver & electrical circuitry) of minimum 50000Burning Hours with 70% of initial Lumen maintained till life ends as perLM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation ColorMatching) <5, Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standard complete inall respect i/c connections with 1.5 sq mm FRLS, PVC insulatedcopper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall beas approved by Engineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminum housing such that LED junctiontemperature shall not rise above 90°C).150 watt 28 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 29 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 30 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. 31 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 32 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 33 Online UPS - Input supply: Single Phase, Output Supply : Single PhaseSupplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) onthe input grid shall be < 5% at 100 %load. (The required LC filters shall beincluded in UPS cost), extreme power factor kit to be include to limit the inputpf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPSshall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7laging to 0.7 leading power factor loads. UPS shall be suitable for incomingsupply AC single phase 160-270V 50 Hz and delivering output AC supplytrue sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overloadcapacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shallcomply with low voltage electromagnetic compatibility (EMC) achieved asper EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and FrequencyIndependent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPSshould be with IGBT Based Inverter Technology, CommunicationRS232/RS485/SNMP port open protocol for BMS integration as perapproved by Engineering in charge. Required battery racks, DC breaker ofsuitable rating and interconnecting copper conductor cable of suitable sizeand connectors and all required accoseries are inclusive in the cost. TheUPS should have QR code which should contain drawing, test report OEMmanual, Geo- Tag of manufacturing location etc. 6 KVA

Key Value

Document Fees
INR 590 /-
EMD
INR 8750.0 /-
Tender Value
INR 4.15 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail