Science and Technology Statutory Bodies & Commissions/Committees Closing in 0 days TDR #50475649

Tender For Provision Of Air Conditioning Work For Embedded System Prototyping Lab And Gyrotron Lab At Csir Ceeri Pilani Rajasthan

Issued by Statutory Bodies & Commissions/Committees · pilani, Rajasthan
Tender Value
74.63 Lakhs
Estimated cost
Bid Submission
07 Aug 2025
0 days left
EMD
1.49 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
pilani → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Provision Of Air Conditioning Work For Embedded System Prototyping Lab And Gyrotron Lab At Csir Ceeri Pilani Rajasthan Provision Of Air Conditioning Work For Embedded System Prototyping Lab And Gyrotron Lab At Csir Ceeri Pilani Rajasthan

BOQ

Name of Work:Provision of air conditioning work for embedded system prototyping lab and Gyrotron labat CSIR-CEERI, Pilani (Rajasthan)”
Sl. No. Item Description
1Supply, installation, testing, commissioningof following modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled outdoor units suitable for cooling and heating having100%hermetically sealed inverter type rotary/ scroll compressor(s),minimum two compressors(with individual separate PCB)for above 14HP module, microprocessor based controller, top discharge/side discharge type condensing unit(s), with R-410A refrigerant or equivalent, Vibration isolators with suitable masonry foundation work etc. complete as required. To have a better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD specification and work even at 50-degree Celsius ambient temperature without tripping. The unit shall be able to deliver 100% of rated capacity up to 39 degree Celsius. The unit shall be suitable to work on 400V +/-10%,3 Phase,50 Hz AC power supply and BMS compatible. The unit shall be filled with first charge of refrigerant and ready for use as required. The condenser should be coated with hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion and reduce the risk of degradation, thereby improving overall performance and durability. The ISEER of the unit shall be as per ECSBC-2024 as below and complete as per CPWD specification, connections and interconnections etc. as required. (The ISEER should not less than 5.6)
2Outdoor unit- 14HP
3Outdoor unit- 20HP
4Outdoor unit- 16HP
5Supply, installation, testing, commissioningof following minimum capacity 4 way flow compact VRV/VRF Cassette type indoorceiling mounted unit equipped withsynthetic washablemedia pre filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolations, corded less remote controland necessary accessories etc., suitable for operation on 230V +/- 10%, 50Hz,single phase AC supply, complete as required. The unit must shut down upon receiving signal from BMS system. The unit shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27-degree C DB and 19-degree C WB temperature. (Make will be same as of outdoor unit)
6Compact Cassette type indoor unit 1.5 TR
7Supply, installation, testing, commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230V +/- 10%, 50Hz, single phase AC supply, complete as required. The unit shall have force shut down provision in case of fire on receiving signal from BMS system. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. (Make will be same as of outdoor unit)
8High Wall type Indoor unit 2.0 TR
9High wall type Indoor unit 1.5 TR
10Laying and fixing one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface wall as required.
11Above 35 Sq.mm and up to 95 Sq.mm
12Up to 35 Sq.mm
13Laying and fixing one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
14Above 35 Sq.mm and up to 95 Sq.mm
15Supply& making one end termination with heavy duty single compression brass gland SIBG type, copper lugs duly crimped with crimping tool, PVC tape etc. for following size of armored PVC insulated & PVC sheathed copper cable of 1.1 KV grade as required.
163.5core x 50 Sq.mm. copper Cable
173.5core x 25Sq.mm. copper cable
18Providing and fixing 4.00 mm dia. copper earth wire on surface or in recess for loop earthing along with existing surface / UG cable as required.
19Supply, Installation, Testing, Commissioning including vaccumization and nitrogen testing ofnominal sizes of soft/hard drawn copper refrigerant piping(Thickness greater than or equal 0.8 mm) for VRV/VRF system, complete with fittings, refnets/Y-joints/ branch headers/connection piping kits with suitable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class-O tubler section/with class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 12/19mm thicknessfor suction and liquid lines, all accessories as per specification etc. as required:
20Supplying and fixing following size powder coated M.S. ‘C’ channeltypetrays with coverincluding connectors, bend, tee etc. and fitted on wall/floor/ roof with M.S. fasteners, supports, clamps/MS hanger etc. as required.
21250 mm width X 75 mm depth X 1.0mm thickness.
22Supply and fixing of following sizes piping drain on wall complete with fittings and clamps/supports etc. The joints shall be properly sealed with rubber-based adhesive to ensure proper bonding.The rate shall include UPVC Coupler, reducer, socket, bend, Tee as required as per the site to connect with the Drain Hopper of IDUs.
2325 mm dia. rigid uPVC pipe.
2412 mm nylone braided PVC pipe
25Supplying and Fixing of following sizes de-rusted, cleaned, primed and duly painted M.S. stand for outdoor units, including Fasteners (Fischer) & Fixtures etc. Complete in all respect.
26M.S. stand (14 HP outdoor unit)
27M.S. stand (20 HP outdoor unit)
28M.S. stand (16HP outdoor unit)
29Supply and layingof following sizes ofFRLS PVC insulated flexible copper conductorcable of 1.1 KV gradefor power supply to indoor unit i/c providing and laying of suitable size PVC conduitwhere ever required etc. as required.
303C x 1.5 Sq.mm cable
31Supply and laying of following size overall shielded Control cum Communication cable in suitable PVC conduits between indoor and outdoor units.
322C x 1.0 Sq.mm shieldedcable
33Supply of following sizes of 1.1KV grade copper conductor XLPE insulated and PVC sheathed armored cable conforming to IS : 7098 (Part-I) 1988 ofas required.
343.5 core x 50Sq.mm. copper Cable
353.5core x 25 Sq.mm. Copper Cable
36Supply, fabricating, testing and commissioning of Kiosk type weather proof distribution feeder pillar box of size 800 x 850 x 300mm with a taper of 75mm at top (for protection from rain water) and made out of 3.2 mm (10 gauge) thick CRCA MS Sheet, front and back both side openable, duly hinged doors with locking arrangement by providing both sides hold drafts and all hardware for fabrication of box. The cubical panel should be dust and vermin proof followed by duly phosphatized and powder painted in gray or required shade after rinsing. The cubical panel should be mounted with hardware on angle iron frame 40 x 40 x 6mm and 400mm long legs duly primered and black painted. Frame be grouted with metal fastener and cement concrete 1:3:6 ratio in 150x150x 300 mm and providing brick masonary along angle iron frame above ground level , complete in all respect including S/F of following accessories, their inter connections with suitable size FR PVC copper wires, lugs, testing etc.as reqd.Panel should be fabricated through electrical panel builders only and Delivery challan should be produced along with panel. INCOMER: a) 1No- quick make and quick break 4 Pole current limiting MCCB- 125 Amp., 35 KA with adjustable O/L setting & Thermal Magnetic Release and conforming to IS:13947-2/ IEC 60947-2 with front face and centralized adjustable, line load inter changeability including making connections with lugs/ spreaders etc. as required.b) 1 Set – 200 A, 4 strips copper bus bar of suitablelength, fixed on SMC/DMC type insulators & color coding with heat shrinkable PVC sleeves.c) 1 set- Digital Volt meter (0 - 500V) with in-built selector switch and 3Nos SP AC control MCBs-2A of approved make for 3-phase supply including making connections with lugs, testing etc.d) 1Set- Digital Ammeter with built-in selector switch 3 Nos. CTs 125/5A for 3 phase supply including making connections with lugs, testing etc.e). 1set- Suitable size TP&N Input Terminals to receive XLPE Copper/ Al. cable of 1.1KV grade for incoming circuit.OUTGOING: a)2 Nos.- quick make and quick break 3 Pole current limiting MCCB- 63 Amp., 35 KA with adjustable O/L setting & Thermal Magnetic Release and conforming to IS:13947-2/ IEC 60947-2 with front face and centralized adjustable, line load inter changeability including making connections with lugs/ spreaders etc. as required.b). 2 sets- Suitable size TP&N Terminals to receive XLPE Copper/ Al. cable of 1.1KV grade for outgoing circuits.

AI Tender Summary

OUR REF NO 50475649
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 74.63 Lakhs
LAST DATE 07-08-2025
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Provision Of Air Conditioning Work For Embedded System Prototyping Lab And Gyrotron Lab At Csir Ceeri Pilani Rajasthan Provision Of Air Conditioning Work For Embedded System Prototyping Lab And Gyrotron Lab At Csir Ceeri Pilani Rajasthan
Basic Detail
Tender No 13-8(173)-2025/EME
Bidding Type Tender
Location
City pilani
State Rajasthan
Key Dates
Publish Date 01 Aug 2025
Submission Date 07 Aug 2025
Open Date 08 Aug 2025
Finance
Tender Value 74.63 Lakhs
Tender Fee 1000
EMD 1.49 Lakhs
Exemption Not Available
Document List
dc2448eb-352a-4160-9b5c-5ce12410ee9b.html
BOQ_277838.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 01, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 08, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

dc2448eb-352a-4160-9b5c-5ce12410ee9b.html

xls

BOQ_277838.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders