}

Tender For Provision Of Electric Capacitor Bank Ct Pt Meter, Energy Meter And Allied Wk At Banihal Under Age (I) Bhalra., Bhalra-Jammu And Kashmir

Military Engineer Services has published Tender For Provision Of Electric Capacitor Bank Ct Pt Meter, Energy Meter And Allied Wk At Banihal Under Age (I) Bhalra.. Submission Date for this Tender is 22-08-2025. Civil Work Tenders in Bhalra Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

50474267
Tender For Provision Of Electric Capacitor Bank Ct Pt Meter, Energy Meter And Allied Wk At Banihal Under Age (I) Bhalra.
Tender
Indian
Jammu And Kashmir
Bhalra
22-08-2025

Tender Documents

Tender Details

Tender For Provision Of Electric Capacitor Bank Ct Pt Meter, Energy Meter And Allied Wk At Banihal Under Age (I) Bhalra.; 1 S& F Steel Tubular swaged polestype 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable pole complete all as specified and directed by Engineer-in-Charge 2 Supply & fixing lightening arrestor, expulsion type consisting of multiple spark gaps in series with one or more non linear resister to limit voltage surge on AC power circuit to interrupt power flow current suitable for outdoor installation and exposed direct to sun with ambient temperature below - 10 degree C to 50 degree C suitable for surge discharge capacity 65 KA, 11000 volts grade conformign to IS-4350 including all fittings, complete all as specified and directed by Engineer-in-Charge 3 Supply & fixing in replacement switch air break, gang operated, triple pole, mechanically operatedsuitable for horizontal or vertical mounting, fixed type,mountedoninsulatorandsteel frame with operating mechanism workedfromgroundlevel,provided with locking arrangement for operating handle, consisting of MS channel, HT post type insulator, contacts of copper alloy, high pressure, heavy duty contact assembly,operating rod of 25mm dia GI pipe medium grade, drop out expulsion assembly of phases fuses etc conforming to IS:1018 of 1972 with continuous current rating with 15 insulators ofcurrent rating upto 400 amps 11000 volts grade, complete all as specified and directed by Engineer-in-Charge 4 Material & labour for earthinggalvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including galvanized steel strip 32 mm x 6 mm as earth lead upto equipment by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.complete all as specified and Engineer-in-Charge. 5 Supply & fixing in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised steel strip of 32mm x 6mm to connect earthpit to electrical equipment room, complete all as specified and directed by Engineer-in-Charge 6 Material & labour for earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including earth lead wire 4.0 mmby means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr including testing on completion & dismantling of existing earthing, complete all as specified and directed by Engineer-in-Charge 7 Supply & fixing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised wire of 4mm dia to connect earthpit to electrical equipment room, complete all as specified and directed by Engineer-in-Charge 8 Supply & fixing disc type insulator porcelain vitreous white, brown or green 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamp for conductor of working pressure 11000 volts, complete all as specified and directed by Engineer-in-Charge 9 S&F Pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete all as specified and directed by Engineer-in-Charge 10 Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size95sqmm complete all as specified and directed by Engineer-in-Charge 11 Supply and fix cable jointing kit for 1.1 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size95sqmm complete all as specified and directed by Engineer-in-Charge 12 Supply and fix 11 KVCTPT metering unit , type outdoor oil cooled , pole mounted , CT Ratio:5/5 A , Burden 10 VA, Class-0.5 S , STC -3 KA/1 Sec and PT Ratio 11KV /110 V, Burden -0.50 VA, Class-0.5 S, insulation -12 KV/28KV all as per IS-2705/1992 and IS-3156/1992 complete all as specified and directed by Engineer-in-Charge 13 Supply & fix Trivector meter three phase four wire TVM 110 Volt , PTR 11 kv/110 V , 5A class 0.5 S for active and 1 S reactive with water proof box and suitable copper cable for connection from CT PT Unit. 14 Supply, installation, testing and commissioning sheet metal enclosure out door type, weather proof for Energy Meter Factoryfabricated from 3.15 mm thick CRCA sheet, compartmentalized design, suitable for downloading data from meter to AMRI without opening panel with suitable locking arrangements, of size not less than 0.60 x 0.45 x 0.30 mtr including suitable clump fitted to poles as required at site or directed.complete all as specified and directed by Engineer-in-Charge 15 M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive ofoneprimer coat, one under coat and one finishing coat of alumn paint.complete all as specified and directed by Engineer-in-Charge 16 Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm. complete all as specified and directed by Engineer-in-Charge 17 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5core complete all as specified and directed by Engineer-in-Charge 18 Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 50 Sqmm 3.5 core , 1100 volts grade complete all as specified and directed by Engineer-in-Charge 19 Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foudation of poles/cable,stay assy etc and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge 20 Excavationintrenchesnotexceeding1.5 mtr wideand exceeding1.5 mtr but n.exc 3.0 mtr indepthandgettingoutsoft/loose soilfortakingup orlaying ofcable, foundation of poles, stay etccomplete allasspecified&directed.Note :Due care shall be taken while deciding cable route for excavation.However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation. complete all as specified and directed by Engineer-in-Charge 21 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layers complete all as specified and directed by Engineer-in-Charge 22 Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge 23 Supplyandlayingdryriversandlaidintrenchesascablecushioning 80mm below and 150mm above the cable and punned to 180mm andcoveringcomplete all as specified and directed by Engineer-in-ChargeNote: Punned qty will be measured and paid. 24 S & L brick covering with width equil to length of brick as the mechanical protction to cable with well burned sub class B laid in trenches flat complete all as specified and directed by Engineer-in-Charge 25 M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) forbase of foundation of pole / stay including form work etc.complete all as specified and directed by Engineer-in-Charge 26 Material and labour for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as incoping of pole, including necessary form work complete all as specified and Engineer-in-Charge. 27 Material and labour for GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and directed by Engineer-in-Charge.(clamps for fixing pipe, nuts, bolts washers shall be measured separately ) 28 Material and labour for GI tubing light grade 40mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and Engineer-in-Charge.. (clamps for fixing pipe, nuts, bolts washers shall be measured separately 29 Supplly, installation & testing Feeder Pillar Box,Kisokoutdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA on angle iron 40X40X6mm frame of size and size of panel (1.8 x 1.2 x 0.6 mtr) suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangementpowder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 typeC-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer complete all as specified and directed by Engineer-in-Charge including earth work complete comprising of following :Incoming(a) Bus bar chamber comprising 4 Nos copper strip of size 32 x 6 mm and lenght 600mm each bus bar and having min 10 holes arrangement in each basbar strip. PVC insulated made of copper strip of size suitable for 200A current. PVC sheathed with colour coding.(b) MCCB having current ratings 200Amps with rupturing cap 25 KA , AC 415 Voltsfour pole with microprocessor releasecomplete with spreader links. - 01 No(c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, including suitableCTs with secondary current 5A,with display volt, Amp , Frequency, KWH. -01 NoOutgoing :(a)MCCB having current ratings100 Amps with rupturing cap 16 KA , AC 415 Volts four pole with thermal magnetic releasecomplete with spreader links. - 03 Nos.All accessoriespre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation. 30 Supplly, installation & testing Feeder Pillar Box,Kisokoutdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA on angle iron 40X40X6mm frame of size and size of panel (1.8 x 1.2 x 0.6 mtr) suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangementpowder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 typeC-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of following :(a)MCCB 100 Amps, breaking capacity 16 KA 4 pole , 415 with shunt trip coil - 01 No(b)Heavy duty TP contactor 32 Amps with MCB TP - 20 Amps, 20 KA to connect directly with 3 phase 25 KVAR capacitor bank (including 10 KVAR capacitor bank)- 01 No.(c )Capacitor bank 80 KVAR four stages (50 KVAR + 20 KVAR+5 KVAR + 5 KVAR) Make : L&T/ABB/SIEMENS (EPOCS)(d)Four stage APFC relayMake : L&T/ABB/SIEMENS(e)Heavy duty TP contactors 16 Amps - 06 Nos , MCB TP 10 Amps -03 Nos , MCB TP 6 Amps -03 Nos (f)Current , transformer epoxy resin type capacity 200/5 , class 1 - 06 Nos.(g)Over current and relay protection-01 No Make : L&T/ABB/SIEMENS(h)Over voltage protection - 01 No Make : L&T/ABB/SIEMENS (j)Digital Multifuntional meter which shows voltage , Amps, Power Factor, and frequency -01 No(k)Indication lamps for R, Y, B- 03 Nos(l)Connected copper wiring , selector switch and locking pedestral etc.Note :-Manufacturers Test Certificate shall be submitted by the contractor alongwith purchase voucher. 31 Materials and Labour for connection cable from CT/PT Unit to trivector meter, size of cablesize 1.5 sqmm x 10 core PVC insulated unsheathed FRLScopper cablecomplete all as specified and Engineer-in-Charge.. Make Havells 32 Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm sizecomplete all as specified and Engineer-in-Charge. 33 Material and labour for construction of Platform suitable for 100 KVA transformer of size 2.50m x 2.50m with 1.50m clear height from ground level, 1.00m deep foundation, 150 mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation below ground level, 23cm wide brick masonry in CM 1:6 below & above ground level, hollow space to be filled hard core of size not exceeding 63 mm, deposited spread and levelled in layers not exceeding 15cm thickness, watered and well rammed with 100mm thick cement concreate 1:2:4 type B-2 as in Floor/Top of platform, brick surfaces plastered in CM 1:4 including protection with XPM, gate and chain link fencing rail around the platform with angel iron of 40 x 40 x 6mm frame upto 1.00m clear height supports grouted in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in foundation of angle iron including excavation in any type of soil, returning filling in and removal of surplus soil to a distance 50m,complete all as specified and Engineer-in-Charge. 34 Supply & fix Bus bar Panel, Size:0.8x0.4x0.4 Mtr,Kisokoutdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA on angle iron 30X30X4mm frame of size suitable to incorporate following accessories with front opening doors,locking arrangementpowder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 typeC-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of Bus bar chamber comprising 4 Nos Aluminium strip bus bars PVC insulated made of aluminium strip of size suitable for 200A current. PVC sheathed with colour coding.complete all as specified and Engineer-in-Charge.

Key Value

Document Fees
INR 500 /-
EMD
INR 11670.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail