| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-08-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-09-2025 |
| 2 | 22-08-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-08-2025 |
| 3 | 11-08-2025 | BOQ Corrigendum | BOQ | 22-08-2025 |
| 4 | 11-08-2025 | Tender Corrigendum | Other | 22-08-2025 |
| Sl. No. | Item Description |
| 1 | Servicing of complete desert cooler comprising oiling, greasing of all rotatry, moveable parts, taking down unserviceable parts for necessary repairs/replacement, assembling of desert cooler with old serviceable parts and replacement of unserviceable parts with new serviceable parts all as directed by Engr-in-Charge.Note :-(i)Parts required to be replaced shall be replaced and paid separately as \" supply only \"against relevant item (s) of this schedule. However, labour element involved in replacement is included in unit rate quoted against this item.(ii)Any minor parts, PVC ellbows, connectors, distributor caps, PVC flexible pipe, wire mesh, rubber pasds/ repairs involved to make the desert cooler completely functional even if not notified by Engr-in-Charge shall be carried out by the contractor without any extra cost to the department. |
| 2 | Supply only the following items to be incorporated against item 1 here-in-before:- |
| 3 | Supply of wood wool pad 750 gms weight complete all as specified and directed . |
| 4 | Switch piano single pole one way 6 Amps. |
| 5 | Indicator lamp 6 Amps. |
| 6 | Selector switch for speed controller of motor (three steps). |
| 7 | Capacitor for desert cooler of any capacity |
| 8 | Front grill for desert cooler Make- Khaitan, Crompton Greaves, Bajaj, Havells. |
| 9 | Desert cooler fan motor with fan complete Make- Khaitan, Crompton Greaves, Bajaj, Havells as Approved. |
| 10 | Supply and fixing in replacement plug top 5 Amps 3 pins all as specified and directed. Make Havells REO, Schnieder, Indoasian. |
| 11 | Supply and fixing in replacement plug top 15 Amps 3 pins all as specified and directed. Make: Havells, Schneider, Anchor, Legrand. |
| 12 | Supply and fixing in replacement of PVC pipe 15mm dia complete all as specified and directed. |
| 13 | Supply and fixing in replacement of PVC distributor with one inlet and three outlets heavy duty complete all as specified and directed. |
| 14 | Supply and fixing in replacement of PVC fan blade of existing size as approved complete all as specified and directed. |
| 15 | Painting of Desert coolers at site or site of work with two coats of synthetic enamelled grey paint or any other paint from outside complete including shutter, top, bottom, with grey paint machine and inside with black anti corrosive paint (Two sides) including writing MES No with 45mm height lettters complete all as specified and directed. |
| 16 | Supply and fixing in replacement of submersible/tullu pump, of wattage as approved complete all as specified and directed. |
| 17 | Supply and fixing in replacement of wire mesh powder coated, for fixing wood wool pads complete all as specified and directed. |
| 18 | Supply and fixing in replacement of side shutter steel frame of suitable size and capacity complete all as specified and directed. |
| 19 | Overhauling & servicing ofwindow /Split type Air conditioners up to 2 Ton capacity of any make and carry out of following tasks at different location of different establishment including taking down the AC (if required) from existing location, refixing / commissioning and testing the same after overhauling complete including the following :- (a) Inspection, taking down, opening (dismantling), washing the condensor and cooling coil complete with acid/water as required and cleaning with air blower and testing complete (b) Checking / examine operation of condensor, blower motor, cooling coil and checking the air circulation to ensure complete movement of working part trouble free (c) Inspection of leakage in system and removal obstruction if any (d) Checking and correction earth continuity of electric items (e) Checking servicing thermostat and over load and other spares and test its functioning (f) Inspecting all electrical connection and remove if any defects (g) Checking servicing and greasing oiling of blower motor.(h) Top up Refrigerent gas if required.Note: Replacement of minor spares if reqd shall be deemed to ne incl in the rate quoted for the item. |
| 20 | Fan motor for AC ( window/split) capacity 1.5 Ton of approved make and required size to suit the existing AC incl taking out unserviceable fan motor all as specified and directed. |
| 21 | Fan motor for AC ( window/split) capacity 2 Ton of approved make and required size to suit the existing AC incl taking out unserviceable fan motor all as specified and directed. |
| 22 | Rewinding of Fan motor for AC ( window/Split ) of capacity 1.5/2 Ton with super enamelled copper wire of suitable guage and quantity, insulating material incl taking out burnt winding from existing AC all as specified and directed. |
| 23 | Air filter forAC ( split type) of capacity 1.5/2 Ton AC of existing make incl taking out unserviceable filter complete all as specified and directed. |
| 24 | Starting capacitor of capacity 36 -56 Mfdsuitable forAC (Window/split type) of capacity 1.5/2 Ton AC of existing make incl taking out unserviceable capacitor complete all as specified and directed. |
| 25 | Starting capacitor of capacity 80 -120 MfdsuitableforAC (Window/split type) of capacity 1.5/2 Ton AC of existing make incl taking out unserviceable capacitor complete all as specified and directed. |
| 26 | Running capacitor for fan Motor of capacity 4 -6 MfdsuitableforAC ( window/split type) of capacity 1.5/2 Ton AC of existing make incl taking out unserviceable capacitor complete all as specified and directed. |
| 27 | Starting relaysuitablefor AC ( window/split type) of capacity 1.5/2 Ton AC of existing make incl taking out unserviceable relay complete all as specified and directed. |
| 28 | Removing the burnt/defective sealed compressor unit of any type and any make from Air Conditioner window type up to 2.0 ton capacity by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor rotary unit of suitable make as existingby connecting suction and discharge lines with filling of refrigerant gas (in quoted rate), welding/brazing work and tightening foundation nuts & bolts including etc all as specified and directed. Note :- (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b)New compressors as approved by Engr-in-charge will be purchased from authorised dealer only. |
| 29 | Removing the burnt/defective sealed compressor unit of any type and any make from Air Conditioner split type up to 2.0 ton capacity by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed rotary compressorunit of suitable make as existingby connecting suction and discharge lines with filling of refrigerant gas (in quoted rate), welding/brazing work and tightening foundation nuts & bolts including etc all as specified and directed. Note :- (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b)New compressors as approved by Engr-in-charge will be purchased from authorised dealer only. |
| 30 | Replacement of Sheet metal enclosure in/on wall with socket plug top and MCB single pole neutral enclosure with 2 pin + earth plug and socket complete with one single pole MCB of 32 amps 230 volts of repturing capacity of 10 KA and making good the disturbed surface with existing colour matching complete. |
| 31 | Replacement of damaged copper tubing of dia 5/8 inch in Split Air conditioners fordischarge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement complete all specified and specified. |
| 32 | Replacement of damaged copper tubing of dia 3/8 inch in Split Air conditioners fordischarge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement complete specified. |
| 33 | Replacement of damaged copper tubing of dia 1/2 inch in Split Air conditioners fordischarge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified. |
| 34 | Replacement of damaged copper tubing of dia 1/4 inch in Split Air conditioners fordischarge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified. |
| 35 | Replacement of damaged insulation for copper tubing of split air conditioners for any size, complete all as directed. |
| 36 | Repair to Air conditioner window type/Split type up to 2.0 ton capacity by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuming the system and charging of gas (M410a/R134a/R22/R32) as existing and testing etc complete all as specified & directed. Note : (a) Drier capillary and copper tubing are inclusive in quoted rate.(b) Contractor shall be responsible for leakage of refrigerent gasafter carrying out repair/re-charging of the gas within one year of completing jobwithout any extra payment. |
| 37 | Replacement of blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type upto 2.0 ton capacity as per existing model complete all as directed and specified. |
| 38 | Replacement ofblower Motor 0.2/0.25 HP for Air conditioner split type of capacity upto 1.5 ton/2.0 ton/3.0 ton /4.0 ton as per existing model completeas specified and directed. |
| 39 | Supply and Fix in replacement ofPrinted Circuit Board as per existing model forsplit type/window type Air Conditioners of any capacity and any make complete all as directed. Make- Voltas/Carrier/Toshiba/Blue Star/ Voltas. |
| 40 | Replacement ofwireless remote control unit for split/window type airconditioner as per existing model complete all as directed.Make - Carrier (Duracool)/Carrier (X power gold)/LG/VOLTAS |
| 41 | Dismantling of main transformer winding and stamping and material and labour for re-assembling the stamping, rewinding of main transformer, single phase, 50 Hz with super enamelled copper winding wire of existing gauge/weight/turns/tapping and varnishing after repairs including replacement of any defective parts like 15 amp socket, fuse, relay of any type and any size, complete all as specified and directed of capacity 0.5 KVA.Note: Replacement of new parts/worn out parts in lieu of unsv/burnt parts shall be paid separately as supply only item under Srl Item No\"s 39.01 to 39.07 as applicable here-in-after of the BOQ. |
| 42 | Description all as srl item No 34 here-in-before above, but capacity of 1.0 KVA |
| 43 | Description all as srl item No 34 here-in-before, but capacity of 2.0 KVA |
| 44 | Description all as srl item No 34 here-in-before, but capacity of 3.0 KVA |
| 45 | Description all as srl item No34 here-in-before, but capacity of 5.0 KVA |
| 46 | Supply only the spare parts suitable for automatic voltage stabilizer of any make and capacity complete. |
| 47 | Volt meter (0-300 volts) |
| 48 | Control relay |
| 49 | IC controlled circuit for 5KVA |
| 50 | IC controlled circuit for 3 KVA |
| 51 | Control transformer |
| 52 | Main transformer for 5 KVA |
| 53 | Main transformerfor 3 KVA |
| 54 | Supply only voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & including all fitting to mounted on wall etc, designed for unput variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 5KVA all as specified and directed . Note:- (Old Unsv voltage stablizer shall be deposted to MES Store Yard. |
| 55 | Shifting and refixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/R32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the systemas existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of split AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas,Insulation and LDPE pipe are inclusive in quoted rate.(c)making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregade, 15mm thick rendering in cement mortar (1:3) making good the disturbed surface with existing colour matching are inclusive in quoted rate. |
| 56 | Shifting and refixing of window AC of any make and any type after servicing and charging of gas (M410a/R134a/R-22/R32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the systemas existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of window AC are included in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas and LDPE pipe are inclusive in quoted rate.(c)Making hole on wall andgood the disturbed surface with existing colour matching are inclusive in quoted rate. |
| 57 | Taking down sealed compressor of 165ltr/175 ltr capacity of refrigerator of any make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity as approved by Engr-in-Chrage connecting sealed unit and discharge pipe with gas welding and soldering rod complete all as specified and as directed. |
| 58 | Taking down sealed compressor of 286ltr/310/300 ltr capacity of refrigerator of any make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity as approved by Engr-in-Chrage connecting sealed unit and discharge pipe with gas welding and soldering rod complete all as specified and as directed. |
| 59 | Thermostat switch for refrigerator of any capacity fixed in repairs, complete all as specified and directed. |
| 60 | Charging of refrigerator with suitable gas after vacuming/pressure and checking leakage including flushing the system of the refrigerator of any make and 165 ltr capacity,complete all as specified and directed. |
| 61 | Charging of refrigerator suitable gas after vacuming/pressure and checking leakage including flushing the system in the refrigerator of any make and 230/286/300/310ltr capacity, complete all as specified and directed. |
| 62 | Overload protection relay incl replacement for 165/175/180 Itr cap refrigerator any make and type. |
| 63 | Overload protection relay incl replacement for 286/300/315 ltr cap refrigerator any make and type |
| 64 | Gas charging CFC free for Refrigerator of cap 165/175/180 litres including sealing of pipe and commissioning and testing complete all as specified and directed. |
| 65 | Gas charging for Refrigerator of cap 286 to 310 litres including sealing of pipe and commissioning and testing complete all as specified and directed. |
| 66 | Supply & fixing in replacement of thermostat switch for refrigerator of existing Make/Type as approved in Engr-in-Charge complete all as specified. Make-Whirlpool/LG/Godrej/Voltas |
| 67 | Supply & fixing in replacement of Defrost timer TMDE706 SC cycle time 6H35M, 60 Hz/7H54M, 50Hz single phase 220-240v complete all as specified and directed. |
| 68 | Bottel shelf for 165/175/286/300/315 ltr cap refrigerator any make and type as approved by Engr-in-Charge. |
| 69 | Ice tray for 165/175/286/300/315 ltr cap refrigerator any make and type as approved by Engr-in-Charge. |
| 70 | Supply & fixing in replacement of copper tube of size 1/4\". |
| 71 | Supply & fixing in replacement of anti moist solution |
| 72 | Supply & fixing in replacement of dry filter |
| 73 | Supply & fixing in replacement of compressor coil complete including gas welding and soldering complete for 165/175/215 Ltrs capacity refrigerator all as specified and directed. |
| 74 | Supply & fixing in replacement of compressor coil complete including gas welding and soldering complete for 286/310/340 Ltrs capacity refrigerator all as specified and directed. |
| 75 | Supply & fixing in replacement of Magnetic door Gasket for 165/175/215 Ltrs capacity refrigerator all as specified and directed. |
| 76 | Supply & fixing in replacement of Magnetic door Gasket for 286/300/310/340 Ltrs capacity |
| 77 | Supply & fixing in replacement of copper capilary tube (036) all as specified and directed. |
| 78 | Supply & fixing in replacement of freezer cabinet for refrigerator 165/175/180 Ltrs complete all as specified. |
| 79 | Supply & fixing in replacement of freezer cabinet for refrigerator 286/310 Ltrs complete all as specified. |
| 80 | Wastage water tray for 165/175/286/300/315 Itr cap refrigerator any make and type. |
| 81 | Lamp with holder for 165/175/286/300/315 Itr cap refrigerator of any make and type as approved by Engr-in-Charge. |
| 82 | Taking down sealed compressor of water cooler any make of capacity 40/80 Ltrs and supply and fixing in replacement sealed compressor and connecting up suction and discharge copper pipe with gas welding pressure testing of leakage rectification, vaccumising and charging the refrigerant gas , testing , commissioning complete all as specified. |
| 83 | Taking down sealed compressor of water cooler any make of capacity 60/120 Ltrs and supply and fixing in replacement sealed compressor and connecting up suction and discharge copper pipe with gas welding pressure testing of leakage rectification, vaccumising and charging the refrigerant gas , testing , commissioning complete all as specified. |
| 84 | Replacement condensor fan motor 1/35 HP 230 Volt AC single phase suitable for water cooler all as specified and directed. |
| 85 | Replacement condensor fan motor 1/83 HP 230 Volt AC single phase suitable for water cooler all as specified and directed. |
| 86 | Detecting the gas leakage , rectifying the defects, vacumising and charging fresh refrigerant gas and commissioning and testing the water cooler 40/80 and 60/120 ltrs complete all as specified and as directed. |
| 87 | Preparation of old painted steel surface of water cooler by complete scraping and applying one coat of synthetic enamel paint by spraying on outer surface as per existing colour and black on bottom portion such as compressor, bottom frame etc of 40/80 ltrs capacity and writing MES Noon watercooler body, complete all asspecified & as directed.. |
| 88 | Preparation of old painted steel surface of water cooler by complete scraping and applying one coat of synthetic enamel paint by spraying on outer surface as per existing colour and black on bottom portion such as compressor, bottom frame etc of 60/120 ltrs capacity and writing MES Noon watercooler body, complete all asspecified & as directed. |
| 89 | Supply & fixing in replacement of strainer (Micro filter) suitable for 1/4\" dia gas pipe complete condensor coil for water cooler any type and capacity. |
| 90 | Supply & fixing in replacement of condensor coil of water cooler including connection with gas welding or soldering with the refrigeration system complete all as specified and directed. |
| 91 | Supply & fixing in replacement of overload protection relay for water cooler of any capacity complete all as specified and directed. |
| 92 | Supply & fixing in replacement of thermostat for water cooler of existing capacity and Make, complete all as specified and directed. |
| 93 | Supply & fixing in replacement of condensor fan blade of existing size complete all as specified and directed. |
| 94 | Supply & fixing in replacement of stainless steel bib cock push type 15 mm chromium plated all as specified and directed. |
| 95 | Supply & fixing in replacement of PVC flexible cable 3 core of size 1.5 Sqmm complete all as specified and directed. |
| 96 | Supply & fixing in replacement of relay assy for water cooler of any capacity and existing make as approved complete all as specified and directed. |
| 97 | Supply and fixing in replacement of float valve 15mm bore of PVC rigid type with polythene ball complete all as directed as approved complete all as specified and directed. |
| 98 | Repairing of water cooler tank by welding or use of stainless steel sealent complete all as specified and directed. |
| 99 | Supply & fixing in replacement of wastage pipe complete all as specified and directed. |
| 100 | Gas charging CFC free including commissioning and testing complete all as specified and directed. |
| 101 | Casing capping 40mm size all as specified and directed. |
| 102 | Casing capping 25mm size all as specified and directed. |
| 103 | Servicing the water cooler of any make including cleaning the water tank, condensor and the side body by washing, rubbing down including removing all the dust, dirt complete all as directed. |
| 104 | Supply and charging of Refrigerant gas R-22/R-410 complete all as directed. |
| 105 | Supply and charging of Refrigerant Gas R-407c/R-134a/R-32/R-404a/R-507a/R-600 complete all as directed. |
| 106 | Taking down sealed compressor of upto 320ltr capacity of deep freezer of any make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity as approved by Engr-in-Charge connecting sealed unit and discharge pipe with gas welding and soldering rod complete all as specified and as directed. |
| 107 | Taking down sealed compressor of 400 to 500ltr capacity ofdeep freezer of any make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity as approved by Engr-in-Charge connecting sealed unit and discharge pipe with gas welding and soldering rod complete all as specified and as directed. |
| 108 | Servicing the deep freezer of any make including cleaning the water tank, condensor and the side body by washing, rubbing down including removing all the dust, dirt complete all as directed. |
| 109 | Gas charging CFC tree for deep freezer including commissioning and testing complete all as specified and directed. |
| 110 | Supply & fixing in replacement of over load protection relay. |
| 111 | Supply & fixing in replacement of blower fan motor for 200 Ltrs capacity Deep Freezer of make and any type complete all as specified. |
| 112 | Supply & fixing in replacement of thermostatic switch for Deep Freezer of the existing type and make complete all as specified and directed. |
| 113 | Charging of refrigerant gas R407/R134 in compressor of cold storage room of refrigerant cooling system in Walk in cold storage room all as specified and directed. |
| 114 | Repairing/ servicing of walk in chiller room of capacity 10 TR including cleaning of filters, cleaning of chambers ( Work should be done by authorised service engineer of manufacturer unit)all as specified and directed. |
| 115 | Supply & fixing in replacement of over load protection relay of existing make and capacity. |
| 116 | Supply & fixing in replacement of unservicebale wiring kit |
| 117 | Supply & fixing in replacement of walk in cold room evaporator fan motor by existing make and type all as specified and directed. |
| 118 | Descaling of shell tube type condenser capacity 48 Ton after opening both end covers, cleaning with hydrochloric acid pocking, brushing and cleaning the inner surfaces of condenser and re-assembling and providing new rubber gasket at end and hydrulic pressure testing complete all as specified directed. |
| 119 | Repairing of operational control panel board of 8x12 Ton capacity 440 volt 50 Hz, scroll compressor 7.5 BHP mono block pump, automatic Humidity control system and interlocking including replacement of defective wiring with standard copper conductor, contractors, selecter switch and any other defective parts (Note:- Maintenance work will done by the authorised service engineer all as specified and directed by Engr-in-Charge.) |
| 120 | Supply & fixing in replacement of thermal Over load relay in AC Plant. |
| 121 | Supply & fixing in replacement of HRC Fuses 6-30 Ampin AC Plant. |
| 122 | Gas charging R-407 in AC Plant. |
| 123 | Nitrogen Gascharging for Detecting leakage in AC Plant. |
| 124 | Refrigerant Gas R-22/R-32 in AC Plant. |
| 125 | Non Freezing Compressor Oil in AC Plant. |
| 126 | Painting of cooling tower, motors, compressors, Blower casing, pipe lines and control panel use in AC plant room by one coat of red oxide and one coat of paint enamel after preparation of surface by scrubbing |
| 127 | Supplying Strip heater straight type(3KW) for package type AC plant complete all as specified.Make: Theta/Dasspass/Airex. |
| 128 | Relay in control panel of capacity of (30Amp/40Amp) for AC Plant. |
| 129 | Solenoid valves for AC Plant. |
| 130 | Three way gate valve for AC plant. |
| 131 | AHU Motor and condensor motor repair of AC plant |
| 132 | Heating coils for AC plant |
| 133 | Repair or replacement damaged indicator lamp for AC Plant. |
| 134 | Taking down and dismantling geyser of any make and cap 25/50 ltrs & taking out water inlet outlet assly, removing glass wool and taking out the inner tank, descaling the assembly and tank, detecting the leakage, welding/brazing the defected part, repacking the glass wool and refixing the same after making it funcional including replacement of worn out nuts bolts washer etc complete ass as specified and directed. |
| 135 | Supply and fixing in replacementof water inlet and outlet assembly of any make as required at site with rubber gasket suitable for geyser of25 ltrs capacity electric driven water storage heater with provn of housing for thermostat assembly, heatingelement fixing arrangement nuts bolts and washers etc. complete all as specified and directed. |
| 136 | Supply and fixing in replacementof water inlet and outlet assembly of any make as required at site with rubber gasket suitable forgeyser of 50 ltrs capacity electric driven water storage heater with provn of housing for thermostat assembly, heatingelement fixing arrangement nuts bolts and washers etc. complete all as specified and directed. |
| 137 | Supply & fixing in replacement thermostat switch for electric water heater storage type of cap 25/ 50 ltr, 230 volts of any make of geyser as approved by Engr-in-charge. |
| 138 | Supply & fixing in replacement thermostar switch short type for electric water heater storage type of cap 25/50 ltr,230 volts of any make of geyser as approved by Engr-in-charge. |
| 139 | Supply & fixing in replacement thermostar switch 2 Pin for electric water heater storage type of cap 25/50 ltr,230 volts of any make of geyser as approved by Engr-in-charge. |
| 140 | Supply & fixing in replacement thermostat switch 4 Pin for electric water heater storage type of cap 25/50 ltr, 230 volts of any make of geyser as approved by Engr-in-charge. |
| 141 | Supply & fixing in replacement heating element with triangular base ISI marked, single phase, 230 volt, cap 1.5 KW. All as specified and directed. |
| 142 | S&F in replacement heating element with round base ISI marked, single phase, 230 volt, cap 1.5 KW. All as specified and directed. |
| 143 | S&F for replacement indecator lampos rectangulan by 230V AC system for any make of geyser all as specified and directed. |
| 144 | Supply & fixing in replacement water storage inner tank of SS material for 25 ltrs capacity geyser, with provn for fixing 15mm dia galvanized air release valve all as specified and directed. |
| 145 | Supply & fixing in replacement water storage inner tank of SS material for 50 ltrs capacity geyser, with provn for fixing 15mm dia galvanized air release valve all as specified and directed. |
| 146 | Supply & fixing in replacement MCB SPN 20 Amps 240 volts , rupturing cap 10 KA,\"C\" series all as specified and directed. |
| 147 | Supply & fixing in replacement MCB DB 2 way complete with fixing accessories all as specified and directed. Make Havells,Indoasian, Schnieder. |
| 148 | Supply & fixing in replacement thermal cut out Bimetallic disc type with snap action switch, with operation temperautre below the boiling point i.e. 90+ 6˚Cwith manual reset knob for Geyser. |
| 149 | upply & fixing in replacement plug top 15 Amps 2 pins all as specified and directed Make: HAVELLS reo, Schnieder, Indiaasian |
| 150 | Painting of geyserof cap 25/ 50 ltr complete with superior quality synthetic enamel whitepaint by spray paintingafter scraping old paint and making surface clean all as specified and directed. Note: contractor has make an arrangement for spray painting within premises of Garrison as directed by Engr -in-charge. Note :-Rate quoted shall be deemed to include taking downtransporting Geysers from bldgs to specified loc for cleaning and painting and re-installing the sameat the requisite location after doing needful. |
| 151 | Supply and fixing in replacementelectric water heater, storage type steel body with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed. Make Godrej/Havells(Monza EC),or equivalent as per list of makes. Note:-Old Unserviceable geysers shall be deposited to MES store yard. |
| 152 | S&F for replacement heating element with triangular base ISI marked, single phase, 230 volt,cap 2 KW all as specified and directed. |
| 153 | S&F for replacement heating element with round base ISI marked, single phase, 230 volt,cap 2 KW all as specified and directed.. |
| 154 | Supply and fixing in replacement pressurerelease valve 15mm bore suitable for fixing with GI pipe/tubing 15mm bore complete all as specified and directed. |
| 155 | Supply and fixing in replacement of heavy duty PVC connection nylon threaded 450mm length (18”) 15mm bore including brass nuts, rubber washers complete on both ends all as specified and directed. |
| 156 | Taking down of ceiling fansize 1200/1400mmfor safety checking by replacingdefective parts/painting/rewinding and re-fixing the ceiling fan after repairs,all as specified and as directed (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc.shall bemeasured and paid separately under respective items as Supply only. However,parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr lengthincluding cost of labour for above replacement aredeemed to be inclusive in quoted rates all as directed.Note:- For No 141 The followint item shall be deemed to be inclusive in the unit rate quoted against SI item.(a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e tightening of loose screw, nuts bolts, etc are inclusive in unit quoted rate. (b) The above job shall be carried ote by a trained electrician haveing qualified in ITI (electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.(c) Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation, (d) The entire job will be carried out in Akhnoor station and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited with the concerned JE (E/M) within 24 hrs. (e) Maitenance of documents ie complaint slip/complaint register & other stationery required shall be of contractor\"s responsibility.(f) Necessary T & P such as ladder, required manpower for taking down and refixing after repair shall be of contractor\"s responsibility.(g) All type of T & P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.(h) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.(j) In case of major defects, entire job shall be completed within 10 days from the date of regisstration of complaint, failing which penalty charge @ Rs 110/- per day shall be levied from the daly of complaint.(k) In case of minor defects, entire job shall be completed within 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be levied from the daly of complaint.(l) The contractor shall maintain a record of all urgent/routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt. |
| 157 | Supply only rotor of ceiling fan of any size |
| 158 | Supply only fan canopies for ceiling fan size of 1200mm/1400mm |
| 159 | Supply onlygun metalbush of suitable size for ceiling fan 1200mm /1400 mm sweep |
| 160 | Supply onlyfan bearing suitable forceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF |
| 161 | Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed. |
| 162 | Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm |
| 163 | Supply only \"U\" clamp for hanging ceiling fan with all nuts, bolts and washers. |
| 164 | Supply onlyouter body of ceiling fan of any size |
| 165 | Supply onlyblades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed. |
| 166 | Supply only safety pins 40mm to 50mm longwith nuts and bolt with washers for ceiling fan of size 1200/1400mm |
| 167 | Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed. |
| 168 | Supply onlyblades (made of aluminium suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed . |
| 169 | Supply only (For BLDC fan) 22 swg Enameled Copper Clad Aluminium Cca winding Wires |
| 170 | Supply only BLDC Ceiling Fan Starter of 1200/1400 mm size and suitable make according to existing ceiling fan |
| 171 | Supply only BLDC ceiling fan Control PCB with remote of 1200/1400 mm size and suitable make accoding to existing ceiling fan |
| 172 | Supply only BLDC Ceiling Fan Magnet 16 pole of 1200/1400 mm size and suitable make accoding to existing ceiling fan |
| 173 | Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed. |
| 174 | Winding of ceiling fan motor 1200 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule. (iii) Taking down of fan,and re-hanging shall be deemed to be includedunder item No. 141 |
| 175 | Winding of ceiling fan motor 1400 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule. (iii) Taking down of fan,and re-hanging shall be deeved to be includedunder item No. 141 |
| 176 | Painting the ceiling fan 1200mm /1400 mm sweep with one coat of syntetic enamel paint as existing colour and writing the MES No- as directed by Engr in Charge.Taking down of fan,and re hanging shall be deeved be included under item No. 141 separately.Note:-Painting of ceiling fan shall be done inside MES complex only. |
| 177 | S&F in replacement of unserviceable wall mounted fan of capacity of 450mm sweep Superior low voltage performance energy efficient and More than 2000 RPM Rated Speed at 1850 revolution per minute frequency 50 HzRated Voltage 230 V , Pull cord for Speed and Oscillation Blade desig of Aerodynamically designed & Blanced Blade all as specified and directed.Note:-Old Unserviceable wall mounted fan shall be deposited to MES store yard. |
| 178 | S&F in replacement un serviceable wall mounted fan of capacity of 400mm sweep Superior low voltage performance energy efficient and More than 2000 RPM Rated Speed at 1850 revolution per minute frequency 50 HzRated Voltage 230 V , Pull cord for Speed and Oscillation Blade desig of Aerodynamically designed & Blanced Blade all as specified and directed. Note:-Old Unserviceable wall mounted fan shall be deposited to MES store yard. |
| 179 | Supply and fixing in replacement of unserviceable energy efficeint Ceiling fan 1200 mm sweep, energy efficient ISI mark with 5 star rating(BLDC) 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible 3 core of size 1.5 sqmm not less than 0.5 m long complete, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells cat Part No. ES Neo or equivalent inBajaj/ Orient./Halonix as approved.Note:-(a)The contractor shall give a written guarantee of minimum two years from completion of work.(b) NOTE: Old Unserviceable ceiling fan shall be deposited to MES store yard. |
| 180 | Taking down ofexhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) aredeemed to be inclusive in quoted rate all as specified and as directed. (Note:-Rewinding, over hauling and materials to be replaced shall be measured separately under relevant item of BOQ.)Note:- For srl item No 165 above: The following shall be demed to be inclusive in the unit quoted rate:-(a) In each job checking of functioning of fan including its connections, cleaning of fan, greasing of fan, mechanical check i.e tightening of loose screw, nuts, bolts, are inclusive in unit quoted rate.(b) The above job shall be carried out by a trained electrician having sufficient experience. (c) Defective unserviceable part like fan bush, bearing etc will be paid under respective item here-in-after as supply only. (d) The entire job will be carried out in Akhnoor and necessary documents showing qtr No, bldg No supported with user signature shall be preepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs. (e) Necessary complaint slip/complaint register & other stationery required shall be contractor responsibility.(f) All type of T & P, such as ladder, helper shall be contractor responsibility. (g) All types of T & P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.(h) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after rapairing.(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @ 100/- per day shall be revied from the date of registration of complaint.(k) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complint, failing which penalty charges @ 50/- per job shall be revied from the date of registration of complaint.(l) The contractor shall maintain a record of all urgent/routine work ans if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra cost. |
| 181 | Winding of Exhuast fan 450mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm qmm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. |
| 182 | Description all as perSl item No 166 here in above but300 mm sweep |
| 183 | Description all as perSl item No 166 here in above but230 mm sweep |
| 184 | Supply only fan bush of suitable size for exhaust fan of the any sweep |
| 185 | Supply only 4 MFD capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha |
| 186 | Supply only metal louvers of suitable size for exhaust fan of the 450mmsweep |
| 187 | Supply only fan bearing of suitable size for exhaust fan of 450mmsweepincluding greasing. |
| 188 | Supply only 3.15 MFD capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha |
| 189 | Supply only metal louvers of suitable size for exhaust fan of the 300mmsweep |
| 190 | Supply only fan bearing of suitable size for exhaust fan of 300mmsweepincluding greasing. |
| 191 | Supply only 2.5 MFD capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha |
| 192 | Supply only metal louvers of suitable size for exhaust fan of the 230mmsweep |
| 193 | Painting the exhaust fan of 450mmsweep with one coat of syntetic enamel paint as exiting colour and writing the MES No and return to MES storeyard /user unit from the work shop .as directed by Engr in Charge.Note:-Painting of Exaust fan shall be done inside MES complex only. |
| 194 | All as per item No 178 above but 300 mm sweep |
| 195 | All as per item No 178 above but 230 mm sweep |
| 196 | S&F Exhaust fan, steel body AC single phase, 230 volt of size 300mm sweep with blades frame and louvers and necessary fixing arrangement such as nuts, bolts, washers and connecting up from ceiling rose complete all as specified and directed Cat Part No :- FHVVEMTDBB12 Ventil Air DB D/HAVELLS on its equivalent as per makes in PS (cont list of makes.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. |
| 197 | S&F Exhaust fan, steel body AC single phase, 230 volt of size 450mm sweep with blades frame and louvers and necessary fixing arrangement such as nuts, bolts, washers and connecting up from ceiling rose complete all as specified and directed.Cat Part No:- FHVVEMTDBB12 Ventil Air DB D/HAVELLS on its equivalent as per makes in PS (cont list of makes.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. |
| 198 | Supply and fix in replacement exhaust fan of 300 mm sweep made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding all as specified and directed.Cat Part no.- Ventil Air DB(green) or equivalent in bajaj, Crompton, Orient, Khaitan as approved. Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. |
| 199 | Supply and fix in replacement exhaust fan of 250mm sweep made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding all as specified and directed.Cat Part no.- Ventil Air DB(green) or equivalent in bajaj, Crompton, Orient, Khaitan as approved. Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. |
| 200 | S&F in replacement Exhaust fan200 mm sweep 230 volt square type, heavy duty with louvers of PVC body including necessary nut, bolts / screws writing MES No with synthetic enamel paint all specified and directed. Make-Havells Cat Part No- Smart Ventil air(white) in bajaj, Crompton, Orient, Khaintan as approved or its Equivalent cat part of make.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. |
| 201 | Taking down aluminium/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceilingand apply 2 coat of white wash/distemper to meet the existing surface and removing materials and debris to outside the premise neat and clean complete all as specified and directed. |
| 202 | Point wiringfor 5 Amp switch /socketsindependent board using approved colour coding as per IS with 1.5 sqmm single core PVC insulated, unsheathed FRLS cable1100 volts grade ISI 694 marked, multi stranded with copper conductor drawn through and incl concealed PVC conduit heavy duty, 19/20mm dia, ISI marked with accessories in wall/roof/ceiling etc incl terminal boxes fabricated with 1.6mm MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators,sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Note:- (a)Switches, sockets outlets,blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separately. |
| 203 | S&F white/warm white powder coated CRCA housing with LEDs 36W, 230 V, 50 HzSurface mounting LED 2 feet x 2 feet luminaries, Sweamless front frame with flat white light transmission acrylic cover complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size.complete all as specified.Cat Part No-BZRSQL of Bajaj or its equivalent of Havells, Orient,Philips, Wipro as approved by GE. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy