| 1 | M & L for taking down the ceiling fan /Exhaust fan /cabin / wall fan/ table fan / pedestal fan of any size from various building/ locations and opening the same for servicing by cleaning each part with air blower/vacuum cleaner and cloths, includingreplacement of worn out nuts, bolts, screws, washers, split pin rubber pad, oiling greasing, writing MES No. of fan with black paint and refixing testing complete all as specified and as directed. |
| 2 | M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, shaft and Capacitor where ever requiredcomplete all as specified and as directed. |
| 3 | All as per item No 2 but here-in-before metal exhaust fan of size upto 230 mm sweep. |
| 4 | All as per item No 2 but here-in-before exhaust fan of size upto 300 mm sweep. |
| 5 | All as per item No 2 but here-in-before exhaust fan of size 450 mm sweep. |
| 6 | All as per item No 2 but here-in-before exhaust fan of size 600 mm sweep. |
| 7 | All as per item No 2 but here-in-before PVC fresh air fan of size 200mm/250mm sweep. |
| 8 | All as per item No 2 but here-in-before wall/cabin fan of any sweep |
| 9 | All as per item No 2 but here-in-before pedestal fan of any sweep from 450 upto 600mm.Notes for Srl item No. 2 to 9 :- Rates are inclusive of transportation to work shop and carrying out rewinding, transportation to site after rewinding& testing on installation . |
| 10 | S&F in replacement of upper and lower Gun metal bush for ceiling fans of anymake & sweep complete all as specified and directed. |
| 11 | S&F in replacement of Ball bearing of suitable size for ceiling /wall /pedestal /cabin /table Exahust fan of any make and sweep complete all as specified and directed. |
| 12 | S&F in replacement of Rotar shaft for ceiling fan of any make and sweep complete all as specified and directed. |
| 13 | S&F in replacement of ceiling fan capacitor of 2.5 mfd complete all as specified and directed. |
| 14 | S&F in replacement of ceiling fan capacitor of 3.15 mfd complete all as specified and directed. |
| 15 | S&F in replacement of ceiling fan capacitor of 4 mfd complete all as specified and directed. |
| 16 | Supply and fix in repairfan regulator electronic type (5 step) complete all as specified and directed. |
| 17 | S&F in replacement of Flexible wire 23/0.0076 three core copper conductor complete all as specified and directed. |
| 18 | S&F in replacement of Flexible wire 40/0.0076 three core copper conductor complete all as specified and directed. |
| 19 | S&F in replacement of MS clamps for down rod complete with nut, bolt and rubber pad, split pin and washer for ceiling fan of any size & make. |
| 20 | S&F in replacement Fan blades with screws, nuts and washers for ceiling fans of any make and sweep as required at site. |
| 21 | S & F in replacement Anti suicide fan rod 300mm long, white, MS pipe zinc plated, 19 mm OD, spring set grade 3 carbon steel material zinc plated, opening at impact load of 22 kgf + and spring \"hidden in the pipe\" will expand to about 1 mtr or more, complete all as specified and directed.Make: Gold life or any other equivalent as approved |
| 22 | Supply and fixing in replacement down rod for ceiling fans, 300 mm long 19 mm outer dia with holes on both ends of the rod for connection wire complete all as specified and directed. |
| 23 | Supply andfixing in replacement down rod for ceiling fans, 600 mm long19 mm outer dia with holes on both ends of the rod for connection wire complete all as specified and directed. |
| 24 | S&F condenser carrier clip (PVC) in build connector two way fixed with screwon down rod or housing complete all as specified and directed. |
| 25 | S & F 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, B class insulation having aerodynamic profile blades for silent operation comprising of remote ,3 nos. blades with dust and mark resistance coating, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding fan motor having power factor not less than 0.9, minimum service value 3.5 CMM/W, Air delivery minimum 280 CMM as per IS-374:1979 (amended upto Mar 2002) including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC supplyincluding writting MES Number having letter size of height 3 cmwith black paint complete all as specified and directed. Make: Crompton/ Havells/ Bajaj.Note: Old UNSV ceiling fan shall be depossited to MES store yard |
| 26 | S & F in replacement air ventilating fan 300 mm sweep Metallic body, AC, single phase, 230 volts,complete with louvers shutters and including PVC insulated 3 core 1.5 sqmm copper cable from ceiling rose to exhaust fanincluding writting MES Number having letter size of height 3 cm with black paint complete all as specified and directed.Make: Crompton/ Havells/ Bajaj.Note: Old UNSV exhaust fan shall be depossited to MES store yard |
| 27 | S & F in replacement of wall mounted fan 400mm sweep, energy saving fans, 230 V, 50 Hz including writting MES Number having letter size of height 3 cmwith black paint complete. Make: Crompton/ Havells/ BajajNote: Old UNSV wall fan shall be depossited to MES store yard |