| 1 | New 11KV Lines: (150 CKM) |
| 2 | Galvanised Steel Tubular Pole SP-60 - 12 mtrs(H/D) |
| 3 | Galvanised Steel Tubular Pole SP-60 - 12 mtrs(N/D) |
| 4 | Galvanised Steel Tubular Pole 9.5 mtrs |
| 5 | ACSR\"Raccoon\" conductor |
| 6 | ACSR\"Weasel\" conductor |
| 7 | G.IChannel cross arm 75×40×4.8×2280 mm |
| 8 | G.IChannel cross arm/ V Cross arm 75×40×4.8×1200 mm |
| 9 | G.IChannel top bracket 75×75 * 40 *4.8 * 310 mm |
| 10 | Polymer 11 kV ( Double) Disc insulator ( 45 KN) |
| 11 | Polymer 11 KV Pin Insulator(5 KN) |
| 12 | G.I H/W fittings for ACSR\"Raccoon\" conductor |
| 13 | G.I H/W fittings for ACSR\"Weasel\" conductor |
| 14 | G.I Single Teir Z - type ( 50 × 50 × 6 ) bracing set |
| 15 | G.I Earthing pipe 40mm ( 1 mtr length) |
| 16 | G.I. Wire 8 SWG |
| 17 | Aluminium Lugs |
| 18 | G.I Cradle GuardingCross arm for DP sturuture ( 75 × 40 ×2210) |
| 19 | G.I Cradle Guarding Cross arm for single pole( 75 × 40 ×2210) |
| 20 | G.I.Eye Bolts-16mm |
| 21 | Y- Guy Stay Set |
| 22 | Back Clamp forGuardingcross arm. |
| 23 | G.I Nuts & Bolts ( Size M16) |
| 24 | G.I Spring Washer ( Size M16) |
| 25 | G.I Plain Washer ( Size M16) |
| 26 | G. I. wire , 8 SWG for guarding and grounding |
| 27 | G. I. wire -6 SWG for guarding |
| 28 | HT stay set - Complete |
| 29 | 11 KV guy insulator -88KN |
| 30 | PG clamp, for ACSR Raccon/rabbit |
| 31 | PG clamp, for ACSR weasel |
| 32 | Danger PlateDetails of Danger Plate:1.As per Tender Drawing.2. Steel Strap for Installing along with suitable nuts and bolts. |
| 33 | G.INuts & Bolts 5/8 × 4\" |
| 34 | G.INuts & Bolts 5/8 × 6\" |
| 35 | GI Through Nuts & bolts 5/8 \" × 8 \" |
| 36 | Anti-Climbing Climbing device/Spike |
| 37 | G.I Stay wire , 7/10 SWG |
| 38 | G.I Steel Pole clamp of 12.0/9.5 mt(N/D) G.I. flat 50×6 mm(T) |
| 39 | G.I Steel Pole clamp of 12.0/9.5mt(N/D) G.I. flat 50×6 mm(M) |
| 40 | G.I Steel Pole clamp of 12.0/9.5 mt(N/D) G.I. flat 50×6 mm(B) |
| 41 | G.I Jam clamp of 12.0/9.5 mt (N/D) G.I. flat 50×6 mm |
| 42 | Cement for Grouting of Pole |
| 43 | Cement for Grouting of Stay Set |
| 44 | Alumunium Jointing Sleeves for Raccoon |
| 45 | Alumunium Jointing Sleeves for Weasel |
| 46 | 11 KV lighting spikes |
| 47 | Sundries (charcoal, salt, etc.) |
| 48 | New DTs (25 KVA) - (88 Nos.) |
| 49 | Galvanised STP pole SP 60 -12 Mtrs. |
| 50 | Lightning Arrestor, 11 KV 9 KA (Line Type) |
| 51 | Raccon Conductor |
| 52 | Weasel Conductor |
| 53 | Chemical Earthing- Electrode |
| 54 | G.I. Channel cross arm 75x40x4.8x2800 mm |
| 55 | G.I Channel cross arm 100x50x6x2800 mm |
| 56 | G.I Angle Iron 50 X 50 X 6 X 2800 mm |
| 57 | G.I Pole clamp of (12.0&9.5mt ) flat 50×6 mm(top) |
| 58 | G.I Pole clamp of (12.0&9.5mt . flat 50×6 mm(middle) |
| 59 | G.I Pole clamp of (12.0&9.5mt ) flat 50×6 mm(bottom) |
| 60 | G.I jam clamp . flat 50x6 mm, 12m top |
| 61 | G.I jam clamp flat 50x6 mm, 12m bottom |
| 62 | G.I. nuts and bolts withwasher(Assorted) 5/6x3in |
| 63 | GI throgh bolts ( 5/8 × 8 \") & (5/8X10\") |
| 64 | 11 KV GangOperated Cum DO Unit 200 A |
| 65 | Polymer 11 KV Pin insulator (5 KN) |
| 66 | Polymer 11 kV(Double) Disc insulator ( 45 KN) |
| 67 | HT Stay set |
| 68 | HT Guy Insulator |
| 69 | Stay Wire 7/10 SWG (G.I) |
| 70 | G. I. wire -6 SWG |
| 71 | 11/0.4KV,25 KVA( The maximum allowable losses at rated voltage and rated frequency permitted at 75 0C for 11/0.433 kV transformers can be chosen by the utility as per Table-3 upto 200kVA and Table-6 for ratings above 200kVA as per Energy Efficiency Level-2 specified in IS 1180 (Part-1):2014 for all kVA ratings of distribution transformersor as per latest Amendment of IS and BEE) |
| 72 | LT XLPE Cable 3 .5core 35 Sq.mm.. |
| 73 | 25 KVA-Cut Out 63 A (Wooden housing box, CGI sheet/Galvanized Plain sheet for Rain shed to house Cut Out.) |
| 74 | 11 KV Danger Plate:Details of Danger Plate:1.As per Tender Drawing.2. Steel Strap for Installing along with suitable nuts and bolts. |
| 75 | Bi-metalic Cable lug (Assorted) |
| 76 | Cement for Grouting of Pole |
| 77 | Cement for Grouting of Stay Set |
| 78 | Sundries (charcoal, salt, etc.) |
| 79 | New DTs (63KVA) - (48 Nos.) |
| 80 | Galvanised STP pole SP 60 -12 Mtrs. |
| 81 | Lightning Arrestor, 11 KV 9 KA (Line Type) |
| 82 | Raccon Conductor |
| 83 | Weasel Conductor |
| 84 | Chemical Earthing- Electrode |
| 85 | G.I. Channel cross arm 75x40x4.8x2800 mm |
| 86 | G.I Channel cross arm 100x50x6x2800 mm |
| 87 | G.I Angle Iron 50 X 50 X 6 X 2800 mm |
| 88 | G.I Pole clamp of (12.0&9.5mt ) flat 50×6 mm(top) |
| 89 | G.I Pole clamp of (12.0&9.5mt . flat 50×6 mm(middle) |
| 90 | G.I Pole clamp of (12.0&9.5mt ) flat 50×6 mm(bottom) |
| 91 | G.I jam clamp . flat 50x6 mm, 12m top |
| 92 | G.I jam clamp flat 50x6 mm, 12m bottom |
| 93 | G.I. nuts and bolts withwasher(Assorted) 5/6x3in |
| 94 | GI throgh bolts ( 5/8 × 8 \") & (5/8X10\") |
| 95 | 11 KV GangOperated Cum DO Unit 200 A |
| 96 | Polymer 11 KV Pin insulator (5 KN) |
| 97 | Polymer 11 kV(Double) Disc insulator ( 45 KN) |
| 98 | HT Stay set |
| 99 | HT Guy Insulator |
| 100 | Stay Wire 7/10 SWG (G.I) |
| 101 | G. I. wire -6 SWG |
| 102 | 11/0.4KV,63 KVA( The maximum allowable losses at rated voltage and rated frequency permitted at 75 0C for 11/0.433 kV transformers can be chosen by the utility as per Table-3 upto 200kVA and Table-6 for ratings above 200kVA as per Energy Efficiency Level-2 specified in IS 1180 (Part-1):2014 for all kVA ratings of distribution transformersor as per latest Amendment of IS and BEE) |
| 103 | LT XLPE Cable 3 .5core 70 Sq.mm. |
| 104 | 63 KVA-Cut Out 100 A (Wooden housing box, CGI sheet/Galvanized Plain sheet for Rain shed to house Cut Out.) |
| 105 | 11 KV Danger Plate:Details of Danger Plate:1.As per Tender Drawing.2. Steel Strap for Installing along with suitable nuts and bolts. |
| 106 | Bi-metalic Cable lug (Assorted) |
| 107 | Cement for Grouting of Pole |
| 108 | Cement for Grouting of Stay Set |
| 109 | Sundries (charcoal, salt, etc.) |
| 110 | New DTs (100KVA) - (13 Nos) |
| 111 | Galvanised STP pole SP 60 -12 Mtrs. |
| 112 | Lightning Arrestor, 11 KV 9 KA (Line Type) |
| 113 | Raccon Conductor |
| 114 | Weasel Conductor |
| 115 | Chemical Earthing- Electrode |
| 116 | G.I. Channel cross arm 75x40x4.8x2800 mm |
| 117 | G.I Channel cross arm 100x50x6x2800 mm |
| 118 | G.I Angle Iron 50 X 50 X 6 X 2800 mm |
| 119 | G.I Pole clamp of (12.0&9.5mt ) flat 50×6 mm(top) |
| 120 | G.I Pole clamp of (12.0&9.5mt . flat 50×6 mm(middle) |
| 121 | G.I Pole clamp of (12.0&9.5mt ) flat 50×6 mm(bottom) |
| 122 | G.I jam clamp . flat 50x6 mm, 12m top |
| 123 | G.I jam clamp flat 50x6 mm, 12m bottom |
| 124 | G.I. nuts and bolts withwasher(Assorted) 5/6x3in |
| 125 | GI throgh bolts ( 5/8 × 8 \") & (5/8X10\") |
| 126 | 11 KV GangOperated Cum DO Unit 200 A |
| 127 | Polymer 11 KV Pin insulator (5 KN) |
| 128 | Polymer 11 kV(Double) Disc insulator ( 45 KN) |
| 129 | HT Stay set |
| 130 | HT Guy Insulator |
| 131 | Stay Wire 7/10 SWG (G.I) |
| 132 | G. I. wire -6 SWG |
| 133 | 11/0.4KV,100 KVA( The maximum allowable losses at rated voltage and rated frequency permitted at 75 0C for 11/0.433 kV transformers can be chosen by the utility as per Table-3 upto 200kVA and Table-6 for ratings above 200kVA as per Energy Efficiency Level-2 specified in IS 1180 (Part-1):2014 for all kVA ratings of distribution transformersor as per latest Amendment of IS and BEE) |
| 134 | LT XLPE Cable 3 .5core 150 Sq.mm. |
| 135 | 100 KVA-Cut Out 100 A (Wooden housing box, CGI sheet/Galvanized Plain sheet for Rain shed to house Cut Out.) |
| 136 | 11 KV Danger Plate:Details of Danger Plate:1.As per Tender Drawing.2. Steel Strap for Installing along with suitable nuts and bolts. |
| 137 | Bi-metalic Cable lug (Assorted) |
| 138 | Cement for Grouting of Pole |
| 139 | Cement for Grouting of Stay Set |
| 140 | Sundries (charcoal, salt, etc.) |
| 141 | New AB Cable -(3 Ph-4Wire) - 18 |
| 142 | Galvanised Steel Tubular Pole 9.5m |
| 143 | PCC Pole-8 Mtr |
| 144 | GalvanisedSteel Tubular Pole 8.0m |
| 145 | 3Cx35 Sqmm+1Cx25 Sqmm(Insulated messenger cum neutral) |
| 146 | 3Cx 50 Sqmm +1Cx 35 Sqmm (Insulated messenger cum neutral) |
| 147 | 3Cx 95 Sqmm +1Cx 70 Sqmm (Insulated messenger cum neutral) |
| 148 | Cable Tie |
| 149 | Suspension clamp assembly suitable for Bare messenger (1 No. Suspension clamp with Bracket, 1.5 Mtr. Stainless Steel Strap, 2 Nos. Buckle) |
| 150 | Anchoring/Dead End clamp assembly suitable for Bare or Insulated messenger (1 No. Anchoring/Dead End clamp, 1 No.Universal Bracket, 1.5 Mtr. Stainless Steel Strap, 2 Nos. Buckle) |
| 151 | Eye Hook/Eye Bolt ( Suitable for 9.5mtr, 8 mtr & 8 mtr PCC Pole) |
| 152 | Cross-armG.I(Channel)-300mm |
| 153 | Pole Clamp |
| 154 | G.I Nuts& Bolts complete with washer |
| 155 | Insulating Piercing Connector IPC P2X95for DB Charging as perNFC Std. |
| 156 | Insulating Piercing Connector IPC P3X95 for ABC to ABC Tee Connectionas per NFC Standard. |
| 157 | Cables End Caps for ABC Cables. |
| 158 | ASA Distribution Box (FRP Grade)/ CRCA MS sheet Box for200A, 3PH. 1+6Connectors with Busbar System along with mounting arrangement. |
| 159 | Aluminium Lugs for service connection |
| 160 | Insulation Piercing Multi portSatelliteConnector ( Sizing) - 4 way |
| 161 | Steel Strap for Installingof DB Size 20 mmx0.7m Long |
| 162 | Buckles for Steel Strap for DB Fixing |
| 163 | InsulatedWaterproofBi Metalic Lug forTransformer Connections (Set contains 4 nos. Lugs as per Cable) as per NFC Standard. |
| 164 | InsulatedCrimping type Midspan Joint (Set contains 5 nos. Ferrules as per Cable) as per NFC Standard. |
| 165 | Insulation Piercing Connector for networking/branching (Type - B)Main to Main |
| 166 | Pre-Insulated Bimetallic termination lug for Phases and Neutral |
| 167 | Pre-Insulated mid-span joint for Phases. |
| 168 | Pre-Insulated mid-span joint for Neutral messenger. |
| 169 | Insulating piercing connector for Bare Conductor to AB Cable connection. |
| 170 | Insulating piercing connector for Spike Earthing |
| 171 | Stay Set |
| 172 | Stay Clamp |
| 173 | Guy Insulator (44KN) |
| 174 | G.I Stay Wire7/12 SWG |
| 175 | G.I Earthing pipe 40mm ( 1 mtr length) |
| 176 | Spike Earthing |
| 177 | Insulation Piercing Earthing Connector(Type – E) Main Side 16 -95 Smm & Tap Side 2.5 to 10 Sqmm |
| 178 | G.I. Wire 10 SWG |
| 179 | Aluminium Lugs |
| 180 | Anti- Climbing device/Spike |
| 181 | Cement for Grouting of Pole |
| 182 | Cement for Pole Stay set |
| 183 | New AB Cable -(1 Ph-2-Wire) - 166 |
| 184 | Galvanised Steel Tubular Pole 9.5m |
| 185 | PCC Pole-8 Mtr |
| 186 | GalvanisedSteel Tubular Pole 8.0m |
| 187 | 1Cx16Sqmm +1Cx 25 Sqmm (Insulated messenger cum neutral) |
| 188 | Cable Tie |
| 189 | Anchoring/Dead End clamp assembly suitable for Bare or Insulated messenger (1 No. Anchoring/Dead End clamp, 1 No.Universal Bracket, 1.5 Mtr. Stainless Steel Strap, 2 Nos. Buckle) |
| 190 | Suspension clamp assembly suitable for Bare messenger (1 No. Suspension clamp with Bracket, 1.5 Mtr. Stainless Steel Strap, 2 Nos. Buckle) |
| 191 | Eye Hook/Eye Bolt |
| 192 | Cross-armG.I(Channel)-300mm |
| 193 | Pole Clamp |
| 194 | Nuts& Bolts complete with washer |
| 195 | Insulating Piercing Connector IPC P2x95FOR DB CHARGING as per NFC Std. |
| 196 | Insulating Piercing Connector IPC P3x95 for ABC to ABC Tee Connectionas per NFC Standard. |
| 197 | Cables End Caps for ABC Cables. |
| 198 | ASA Distribution Box (FRP Grade)/CRCA MS sheet Boxfor150A, 1-PH. 1+12 Connection withBusbar System along with mounting arrangement |
| 199 | ALuminium Lugs for service connection |
| 200 | Insulation Piercing Multi portSatelliteConnector ( Sizing) - 4 way |
| 201 | Steel Strap forfor Installing DB Size 20 mm X 0.7 m long |
| 202 | Buckles for Steel Strap for DB Fixing |
| 203 | InsulatedWaterproofBi Metalic Lug forTransformer Connections (Set contains 4 nos. Lugs as per Cable) as per NFC Standard. |
| 204 | InsulatedCrimping type Midspan Joint (Set contains 5 nos. Ferrules as per Cable) as per NFC Standard. |
| 205 | Insulation Piercing Connector for networking/branching (Type - B)Main to Main |
| 206 | Anchoring/Dead End clamp assembly suitable for Bare or Insulated messenger (1 No. Anchoring/Dead End clamp, 1 No.Universal Bracket, 1.5 Mtr. Stainless Steel Strap, 2 Nos. Buckle) |
| 207 | Pre-Insulated Bimetallic termination lug for Phases and Neutral |
| 208 | Pre-Insulated mid-span joint for Phases. |
| 209 | Pre-Insulated mid-span joint for Neutral messenger. |
| 210 | Insulating piercing connector for Bare Conductor to AB Cable connection. |
| 211 | Insulating piercing connector for Spike Earthing |
| 212 | Stay Set |
| 213 | Stay clamp |
| 214 | Guy Insulator (44KN) |
| 215 | Stay Wire7/10 SWG |
| 216 | G.I Earthing pipe 40mm ( 1 mtr length) |
| 217 | Spike Earthing |
| 218 | Insulation Piercing Earthing Connector(Type – E) Main Side 16 -95 Smm & Tap Side 2.5 to 10 Sqmm |
| 219 | G.I. Wire 12 SWG |
| 220 | Aluminium Lugs |
| 221 | Anti- Climbing device/Spike |
| 222 | Cement for Grouting of Pole |
| 223 | Cement for Pole Stay Set |
| 224 | Material for Providing Service Connection to Households. (3081 Nos.) |
| 225 | 2 Core, 2.5 sqmm PVC Cable (Blue colour) |
| 226 | 4 Core, 6 sqmm PVC Cable (Blue colour) |
| 227 | 1. All amounts shall be in Rupees.2. Use separate columns for each type of taxes. Other taxes means entry tax, octroi, exit tax or any other taxes as applicable. |