Tender For Description Of Stores /Items: Processing Of Consumables /Implants /Devices/Accessories, Etc, On Case To Case Consignment Basis, On Rate Contract For A Period Of Three Years, Extendable Upto 6 Months Or Till The Finalization Of The Next Tender, Whichever Is Later, For Department Of Ctvs.; 1 Ventilator, Invasive Pressure Monitoring, IV Drip sets, Anticoagulation Monitoring and Airway Consumables 2 Bain Circuit Adult Based on Mapleson D system, provided with a corrugated tube, expiratory valve and antistatic bag. Should have co-axial modification of the basic T-piece system, developed to facilitate scavenging of waste gases. The process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube. Lightweight anesthesia delivery system. 3 Bain Circuit Pediatric Based on Mapleson D system, provided with a corrugated tube, expiratory valve and antistatic bag. Should have co-axial modification of the basic T-piece system, developed to facilitate scavenging of waste gases. The process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube. Lightweight anesthesia delivery system. 4 Corrugated Tube Connector Should allow connection between all breathing circuits and the ET tube connector. Thecorrugatedtubeshouldbeexpandable. ShouldAllowmovementofbreathingcircuitatpatientend.Should be made of medical grade PVC. Should be compatible with ETT and tracheostomy tube. 5 Micro Aggregate Blood Filter for Red Cell Transfusion Filter media should be 40 micron rated polyester screen media with uniform pore size Should have total filter surface area of170 Sq.cm Should have average capacity of filtering 10 units of blood. 6 Packed Red Cell & Whole Blood Leucocyte Reduction Filters. Bedside filtration of one & two unit of packed red blood cells or whole blood Should have universal spike with microbiological recovery vent Should be with attached straight administration set/automatic self leveling drip chamber Performance should consistently average less than 2x105 residual leukocytes per unit Red cell recovery should average greater than 90%. Filter housing hold up volume should be 25ml for one unit filter and 35ml for two unit filter It should be single use 7 Forced Warming Blanket Should be disposable and two layered; • Should consist of non woven propylene fabric for body warming.• Should be usable with forced air warming units.• Material should be latex free and should meet flammability standard 16 CPR 1610 for safety.• The manufacturer must have all the below listed types of blankets and should quote the prices separately for separate blankets• Full Body Adult• Underbody Adult with Arm and Head Openings• Pediatric Full body• Pediatric underbody Blanket.• Should be compatible with common machines.• Should be CE certified 8 Cuff Inflator and Pressure Gauge •Itisusedtoinflate& preciselymonitorthecuffpressureofET tube, Tracheostomy Tube and LMA Cuff. •Reducetheriskofpressurenecrosisandmucosal ischemia •Theriskofaspirationcanbeavoided Eliminatestheuseofsyringestoinflate&deflatethecuffs. Should have release valve to adjust the pressure. •GaugecalibratedincmH2Owiththedetachablelongconnecting tube. •Shouldhaveinflationbulbfortheinflationofthecuff Shouldhavethehookatthebackoffitsintostandardrail. Should have widely spaced scale markings with colour coded pressure ranges. Ergonomiconehadoperation 9 Intubation Pillow •Reusable Intubation pillow for Head elevated laryngoscopy position (HELP) for airway management of Obese &l arge framed patients. •ShouldbemadeupofDenseFoam. •ShouldbesuppliedwithHeadCradle •ShouldbeVinylCovered •ShouldbeCEmarked 10 Negative Insipratory Force Meter •Should be disposable, compact, Light Weight & amp;single patient use Negative Inspiratory Force Meter to check the Negative inspiratory Force of the Ventilated patients with the facility of memory indicator point ertore cord reset highest force achieved by the patient individually packed ready for use. •Shouldbe ,CE marked 11 Capnography Co2 Sampling Mask •Shouldhavetheprovisionforbreathtobreathmonitoringforboth nose & mouth •Should have the facility to deliver oxygen; allow sampling of exhaled carbon dioxide from mouth & nose at the same time. •ShouldhaveattachedmicrofilterattheCO2samplingportend to protect the CO2monitor •ShouldbeabletoconnecttheLuerlockconnectortoanyside stream CO2 monitor. 12 Colorimetric Disposable CO2 Detector For patients from 250gm to 15+kg. Body weight. Should have the facility of activation by pull tab Technique. Should be able to work for 24 hours once activated by pulling tab. Should be able to indicate- Blue green & yellow colour. •Should have larger CO2 viewing window. •Should have 15mm I.D. Standard Taper at Patient End & 15mm O.D. Standard Taper at Circuit End. Should be CE marked •Sizes Infant, Pediatric & Adult 13 Single Lumen Catheter (Seldinger Technique) Should be polyurethane Single Lumen catheter with J Guide-wire non kinking kit should be radio opaque with fixation wing & integral extension tube with flexible & transparent extension tube (PUR) Size – Catheter 12-22G, Lengths- 10cm-20cm 14 La Line Central Catheter (All Sizes) Should be long I.V Catheter with external needle and fixed proximal hub catheter in fully radiopaque polyurethane protected by a non touch-handling sleeve marking every cm 10 to 20cm. Should be made available in assorted sizes. 15 Swan Ganz Pa Catheter Introducer Kit Set Percutaneous Sheath introducer set should have bonded hemostasis valve & side port along with 0.035 x 45 cm straight & “J” tip guide wire for introducing 7.5 Fr, 8.0 Fr PA Catheter. It should have sheath diameter of 8.5 F & sheath length of ≈11 cm. It should be made of radiopaque polyurethane & should have a coating of Heparin as well as antimicrobial material (Benzalkonium Chloride) on entire sheath surface. It should come with 1 catheter contamination shield, ≈80 cm in length. It should have one 4-waystopcock, one vessel dilator & four 4x 4gauze pads.0ne disposable scalpel, # 11 blade & one 18 ga x 2 ½ thin wall needle. 16 Swan Ganz Thermodilution Vip Catheter Flow directed 5-lumen balloon tipped pulmonary artery catheter. 7.5 Fr in diameter &≈110 cm in length• It should have a coating of Heparin as well as antimicrobial material (Benzalkonium Chloride) on entire catheter surface.• Should be able to give Cardiac output using Thermodilution method• Should be able to give PA pressure, PAWP & RA Pressure when connected to transducer.• Should have proximal infusion & proximal injectable ports at ≈31 cm &≈30 cm respectively.• It should come with one volume-limiting syringe of 1.5cc for balloon inflation 17 Swan Ganz Pa Catheter Flow directed 3 lumen balloon tipped pulmonary artery catheter, 7 Fr in diameter & ≈110 cm in length Should be able to give PA pressure, PAWP & RA Pressure when connected to transducer. Should have proximal infusion port at 30 cm. Recommended guide wire size 0.89 mm. It should come with one volume-limiting syringe of 1.5cc for balloon inflation 18 Pressure infusion bag Should be made up of durable plastic to prevent the rip & tear of bag Should have clear sleeve around the bag to see the contents of the fluid bag. Should have convenient IV pole loop hanger. Should have I.V Bag holder to hang the fluid bag inside. Should have double sealing to prevent the rip or tear of pressure bag Should have stopcock valve. Should have efficient palm fitted bulb for the inflation of bag. Pressure gauge should have 360-degree window to see pressure from all sides. Should have built in bleed valve to check the over inflation of the bag. Sizes- 3000ml. Each bag should have aneroid pressure gauge with inflation capacity of 400 to 700mmHg. 19 Closed Circuit (Pediatric) ISO marked. Length-1.75mtr. double tubing with a Y connector with least dead space. Y connector adopter 15mm to 20 mm connector. Latex free medical plastic material, disposable, non-irritant to tissue, and should not react to anesthetic gases and volatile agents. Outer diameter (OD) 10-12mm. Bag-1L. capacity, natural latex medical grade rubber, antistatic, soft and should not react with anesthetic gases and agents. Expandable type, corrugated, non-kinkable tube. 20 Piece with APL Valve Should be good quality, light weight, non conductive disposable T piece with corrugate tubing 1.8m circuit length, low resistance, 500 ml bag with APL valve with 15F/22F connector, safety cap. 21 Anesthetic Circuit Holder of Adult, Pediatric and Neonatal Circuits •Anesthetic Circuit Holder of Adult, Pediatric and Neonatal Circuits 22 Endotracheal Tubes with Cuff (Disposable) Pre-sterilized, single use• Siliconized PVC non-toxic to tissues.• Implantation tested marking on the tube.• Thermo-sensitive to adapt to tracheal anatomy.• Non-kinkable.• Bevel with Murphy eye.• Radio-opaque line all along the length of the tube to detect the correct position on X-ray.• Should adopt universal connector of 15mm and should be compatible with all circuits.• Cuff should be bonded, non-herniating.• Size range- 2.5 to 8.5 mm in 0.5mm increments.• Inflation of the cuff balloon via a one-way valve with a pilot balloon and should be on the concave aspect of the tube.• Depth marker at the proximal cuff end, 3 cm from the cuff.• Cuff should be smooth, non-traumatic, low-pressure high volume.• ETT opening should be beveled type, rounded edge, facing to the left end of the tube with an angle of 38 +/- 10 0• Markings on the tube to know the depth of insertion and fixation at mouth.• Specified mention on the tube- o Nasal/oralo Outside diameter OD in mm.o Inside diameter ID in mm.a. Made of medical grade PVC. Left and right sided.c. All sizes.d. Bronchial cuff should be of blue color and its pilot balloon should be also of blue colorfor the ease of differentiating between tracheal & bronchial cuffs.e. Pre- sterilized, ready for use.f. Should have pre-inserted stellate to help maintain the shape and curve of the tube. 23 Double Lumen Endotracheal Tube Made of medical grade PVC Left and right sided. All sizes. Bronchial cuff should be of blue color and its pilot balloon should be also of blue color for the ease of differentiating between tracheal & bronchial cuffs. Pre-sterilized, ready for use. Should have pre-inserted stellate to help maintain the shape and curve of the tube. 24 Thermoplastic Supra-Glottic Airway Device Should have soft non inflatable anatomical seal, epiglottis blocker; buccal cavity stabilizer, integrated bite block; integrated gastric channel for passage of nasogastric tube Size: 1, 1.5,2,3,4,5 25 Percutaneous Tracheostomy Set with Tracheostomy Tube: Should be with tracheostomy tube. Should have multiple dilators of different sizes- 14Fr., 21Fr., 24Fr., 27Fr. Guiding catheter over which the dilator is introduced. The guide wire should have position markings. Should have introducer needle with sheath. Should be supplied with essential accessories. 26 Corrugated tube connector Should allow movement of breathing circuit at patient end. Should allow connection between all breathing circuits and the ET tube connector. The corrugated tube should be expandable. Should be made of medical grade PVC. Should be compatible with ETT and tracheostomy tube. 27 Catheter Mounts With Bronchoscopy Port: Should be flexible & Extendable Should be having bronchoscopy port. Should be 360 degree rotating head. 28 Suction Tube 7 mm 30M COIL, 7 MM ID with Bubble Non Conductive 29 Suction tube 5 mm 30M COIL 5 MM ID with Bubble Non Conductive 30 HME filters for neonatal: Low dead space, hydrophobic filtration incorporated with heat and moisture exchange filter and with retainable gas sampling port, disposable good quality. 31 Anti Microbial Breathing System Heated Wire Should be light weight and flexible to minimize drag on circuits, 1.5m heated inspiratory tubing, Silver impregnated 0.5m humidifier connection tube, Auto float humidification chamber with dual float Sizes: Adult, pediatric, Neonatal. 32 Suction Catheter Thumb Controlled Working length should be at least 50cms (working length without Connector) for 10Fr.& above; should be at least 40 cm. in length below 10 Fr.• Should be color-coded and should have open end with lateral eye with length marked in centimeters with male connector with vacuum control device as ISO specifications.• Should be in straight soft blister packing.• Should have markings on the full length of the tube• Should have markings on the catheter.• Sizes 5,6,8,10,12,14,16, and 18 Fr. 33 Leucocyte Reducing Blood Transfusion Set: Blood set should have drip chamber and filter with proven leucocyte reduction properties for leucocyte free blood transfusion for organ transplant use. It should have filter size 40 microns and 180 sq. cm of filter area and should have attached IV set with a luer lock tip. 34 Measured Volume Set (ISO/CE) Should be made up of PVC material Should have soft cylindrical type measure volume chamber with float valve to prevent air embolism The set should have transparent tubing and chamber. Should have capacity of 100ml and 150 ml. Should have drip nozzle with reduced size of drop that has to be uniform at 60 drops/ml. Should have molded bubble latex bulb for extra medication or Y port for injection. Should be sterile ready for use. Should be double packed. Should have short bevel 23 G Vein needle. Should have built in airway for bottle perforating spike (air vent). 35 Surgical Tape Polyethylene Material without Dispenser Sizes: 3 X 9.10 mtrs. 36 Spiral (Polyethylene) Tubing Should be spirally coiled tubing (polyethylene) for drug infusion (Drug compatible). Size – 100,150,200,300 & 400cm. Should be US FDA APPROVED 37 Polyethylene Pressure Extension Tube Should be polyethylene high pressure extension tube (drug compatible) Size – 11, 30, 50, 100, 150, 200 cm. Sh0uld be US FDA APPROVED. 38 Extension Line For Light Sensitive Drugs Extension line for light Sensitive drugs (anti UV). Size – 100,150,200cm. Should be US FDA approved. It should have 200 cm long multichannel tubing to ensure continuous supply 39 Basic Parallel Ventilator Circuit FDA & CE marked should incorporate with in-line nebulization T Valve with automatic closer preventing pressure drop. Must be clear construction 40 Flexible Tubing – Silicone Highly flexible medical grade silicone tubing, autoclavable, can be sterilized by EO. Sizes : 6mm & 8mm; Length of tube roll should be 60.0mtr. 41 Disposable Shoe Cover Should be of good quality (thick) Made from non-toxic non-woven, thick fabric. Well stitched in universal regular size. Skid resistant & dust proof. Hard elasticated for better grip and easy to wear. Should cover the ankles. Size: Assorted- (Std. size of shoe from 7 to 12) & blue color. 42 Disposable Foley’s Catheter (2 way) – Adult & Paed Disposable 2 way latex Foley catheter Should be manufactured from natural rubber latex coated with silicone so as to eliminate the risk of encrustation. Should have symmetrical large capacity balloon to ensure a straight tip and proper flow for good sphincter action to prevent bladder leakage. Should have coned distal end with burr free eyes for atraumatic insertion. Should have hard valve to ensure easy inflation and deflation of balloon. Balloon capacity- 3-5 ml for pediatric and 30 to 50 ml for adult catheter. Length- 20-30 cm. Should have colour coded for instant size identification. Should be sterile and should be individually packed in peel-able pack. Sizes-5 Fr to 22Fr only ISO 9002 CE marking, should confirm to ASTM- F623-99 Guideline specification for Foley’s catheter. 43 50ml Syringe(with Luer Lock) Should be made of clear PVC. Should have rubber seal in the piston Should have a luer lock 44 Absorbable Disposable Pillow Cover for Standard Size 75 X 55CM 45 Disposable chamber for bal Collection with adapter Disposable sterile container for Bronchoscopy application. 46 Bite Block Size 4: Bite block size 4 for oral fixation of ETT size 6.5-8.0mm, Laryngeal Tube size 2 & 2.5 tube should clip into the bite block for protection against occlusion. 47 Bite Block Size 5 Bite block size 5 for oral fixation of ETT size > 8.5mm, Laryngeal tube Size 2 & 2.5 LMA 2 & 2.5 tube should clip into the bite block for protection against occlusion. 48 Bite Block Size 6 Bite block size 6 for oral fixation of laryngeal Tube size 3,4,&5 and LMAs, Tube should clip into the bite block for protection against occlusion. 49 Pediatric Bronchial Blocker Should have a catheter with a bifurcated distal end resembling the bifurcation of the trachea. During insertion through a standard endotracheal tube, both distal ends easily find their way into the two main stem bronchi. Under bronchoscopic vision the lung can be isolated by inflating the balloon. The inflated balloon will always be located at the entrance of the main bronchus. The EZ-Blocker should not dislocate after inflation of the isolated lung. If renewed isolation is required the balloon can be re-inflated without the need to reposition the balloon. Size - 7mm. 50 Medical Grade Soda Lime CO2 Absorbent Granules Medical grade best quality soda lime granules. Hardness, moisture and absorption should be international agency certified. Should be good quality for closed circuit. There should be high contrast pink to white color change after absorbent capacity is exhausted. Pack size should be 5 liter/container. 51 Disposable DVT Sleeve Calf & Thigh design 52 Disposable DVT Sleeve Calf design 53 BIS Sensors It should have four sensors element to capture, recognize and discard artifact. Connector should provide secure click-in connection with push button release It should include an additional above eye element, which captures critical eye motion data, along with other important physiological signals. It should have flexible design adjusts to different head sizes It should have FDA approval Should be supplied by authorized channel partner from principal company/manufacture. Electrode Gel: Potassium Chloride (KCl) , latex free. Sizes ADULT and PEDIATRIC 54 NIRS Sensors Adult and Pediatric for Casmed NIRS Machine 55 Disposable Pulse Oximeter Sensors (SP02) Should be compliant with the equipment intended to continuously estimate and display non-invasively a patients arterial blood oxygen saturation and pulse rate Proposed sensors must comply with Philips Technology. Digit sensors should be available in Adult, Pediatric, Neonatal and Infant sizes to accommodate diverse patient sizes, weights and needs. Seller must have all types of sensors available (e.g., finger, forehead, and ear). Sensor must be available in Adult, Pediatric, Infant and Neonatal Sizes. Sensor extension cables must be available in 4 and 9 lengths. The sensors must be compatible with all generations of Philips Technology inPhilips Oximeters and OEM/Licensee Multi-para meter systems with all generation of Philips technology. The sensor shall resist inadvertent displacement. The sensor shall resist interference from ambient light. The sensors shall not be adversely affected by fluid spills or common disinfectant solutions. 56 Infant Feeding Tube Size: 3-10 Fr., color-coded. Silken smooth tube, medical grade siliconized PVC. X-ray opaque line. Fitted with female luer mount with built-in stopper/ lid. Packed in peel-off pouch, not coiled packing. Sterilized ready to use. Length of tube minimum- 50 +/- 5 cm. Smooth rounded tapered distal end with two lateral eyes. 57 Urine Collection Bag with Transparent Volume Chamber Sterile ready for use. Bag should be manufactured from clinical grade transparent PVC. Capacity- 2000ml.marked in increments of 50 ml. Fitted with non-return valve to avoid spillage. One-meter long super smooth, highly flexible non-kinkable tube which should provide approx. 6.5 mm diameter with universal male connector. Leak proof, single piece/ wielded manufacture. Provided with hanging device to be fitted on to the bed. Stopper drain should be attached with the bag. 58 Clinical thermometer: Good quality. Digital For oral temperature measurement. 59 ACT Cartridges Should have double cell measurement to increase accuracy of results, Should use liquid kaolin activator for real time efficient clot detection, Should allow room temperature storage Hemochron Signature Elite compatible 60 I.V. Set with Flow Controller (DEHP Free) Specially designed I.V. set for controlling the flow rate of fluid made of medical grade DEHP free polymer nonreactive to water- soluble materials. Gravity drive infusion set with wide dial, which operates as thumb wheel like roller clamp. Security door to prevent the accidental change of flow rate. Low cost disposable set. Sterile, individually packed in blister pack 61 Snugger Set All sizes: Three pairs of smooth snuggers with Yellow, Blue & Pink colors for vessel identification. Each snare set should consist of thumb holder handle for easy maneuverability. Specially designed for putting purse string sutures, made of medical grade PVC. Sizes Adult & Pediatric. 62 Disposable Suction Tube & Tip Yankauer Type, Medical grade PVC molded handles with kink resistant tube for per operative suctioning. Tip of Handle should be crown/ standard shape. Vent port to be provided in handle which should be closed with tight sleeve. Soft flexible adaptors at both end of the tube for connection with secure fitment between suction source& handle. Tube Length 2500mm, OD: 9 mm, ID: 6 mm. Sterile packed in poly pouch pack. 63 Ventilator circuit Plain 64 Ventilator circuit with Humidifier Sizes- Adult, Pediatric, Neonatal 65 Ventilator circuit Double water Trap 66 CABG Consumables and CABG Heart Postioners 67 Aortic Punch Should have Sharp, dual cutting edge for clean, precise removal of aortic tissue should have a conical tip for easy insertion by straight or button- hole technique Punch should be available with tapered cutting blade to increase visibility. Should be available in all functional sizes (2.5-6mm) Should have long and short handle configuration 68 Coronary artery retraction clips Should be designed to improve exposure to a coronary anastomosis site. Should be able to small prongs and gently hold tissues away from the vessel to improve vision. Sizes 3mm and 5mm 69 Temporary pigtail pacing wire Should include unipolar atrial and ventricular pacing, pediatric unipolar pacing, and the bipolar pacing lead 70 Tissue Stabilizer for Minimally invasive beating heart surgery. Should be stabilizer to be used via thoracotomy with detachable shaft and should have fully rotating pods. 71 Heart positioner for Minimally invasive beating heart surgery Should be a positioner with detachable shaft for MICS via thoracotomy. 72 Mist Blower Should have specialized nozzle utilizing a micro orifice for fluid delivery and a separate orifice for gas delivery. Should have the malleable shaft and on/off control on the hand piece. 73 Arteriotomy shunts (Intra Coronary Shunts) Sizes 1.0,1.25,1.5,1.75,2.0,2,5,2.5, 2.753.0mm. Teal color for easy detection within the operative site Beveled, ultra-soft tip for easy insertion Single-mold, kink-resistant silicone design for easy insertion andatraumatic removal Radiopaque shunt and radiopaque, non-slip tab with asymmetrically placed tether 74 Intra Aortic Balloon Catheter IAB Catheter should be of 7.5 Fr with displacement volume of 30cc, 34cc, 40 cc. and 8Fr with volume displacement 50cc. It should be abrasion resistant and have good fatigue resistance Should immediately inflate at start up without manual filling of the catheter. It should be compatible with Maquet IABP pump It should have exact 7.5Fr size sheath and dilator set. It should have 0.025 3mm J PTFE stainless steel guide wire. It should be approved by US FDA. 75 Heart Stabilizer- Octopus type Cardiac wall conforming malleable bifid arms with vacuumsuction cups to hold and position the heart in off pump CABG. Should have a thin mount with a constant low profile design for an optimized work area. Stabilizer should allow a vertical drop of the arm into the chest cavity. Should provide 180º side-to-side range of motion of the arm. Integrated channels secure tubing away from the work area 76 Heart Stabilizer- Urchin type The tissue-conforming suction cup with gentle vacuum to securely lift and hold the heart in off pump CABG. Should be designed for apical and non-apical placement of the heart. Should have a flexible arm and mount should be compatible with a range of adult sternal retractors. Should have integrated channels to secure tubing away from the work area 77 Tissue Stabilizer With Canister Tubing Set (For Off pump CABG) - Metallic Titan Flex and Titan Stabilizers provide optimal positioning, stabilization and coronary artery isolation during beating heart. USFDA Approved 78 Arm for Tissue Stabilizer With Canister Tubing Set (For Off pump CABG) - Metallic Arm Titan Flex and Titan Stabilizers provide optimal positioning, stabilization and coronary artery isolation during beating heart. USFDA Approved 79 Endoscopic Vessel Harvesting System The Endoscopic Harvesting System should be designed for use in In conjunction with the 7mm Endoscope. Harvesting Cannula should have four lumens to house the Endoscope, C-Ring, Distal Lens Washer Tube & BiSECTOR Bipolar Ligating Forceps for ligation & division of vessel branches. C-Ring/Distal lens washer should be independently controlled by a C-BiSECTOR can be extended/retracted through the main cannula by inserting it into the Tool Adapter Port, and rotated independently. Bipolar coagulation should be achieved using electrosurgical energy.Short Port Blunt Tip Trocar (BTT) should be provided which is used to provide a port of access for insertion of endoscopic instruments into an incision site. Syringe should be provided for inflation/deflation of the Balloon. 80 7mm Extended Length Endoscope vasio view Hemopro-2 The 7 mm Endoscope (Zero Angle) should be a reusable product, which consist of a stainless steel Shaft housing optical and illumination components. Proximal end should have an Eyepiece for camera adapter attachment,7 mm Endoscope should be designed to be used in conjunction with the removable Dissection Tip for blunt dissection of tissue and isolation of structures in the cavity. 81 Suture Organizer Device to organize Valve sutures / VSD / graft sutures easily in a non-traumatic way. Should organize a minimum of 8 suture sets. 82 Cardio Pulmonary Bypass Oxygenators, ubings and Cannilae 83 LV Vent with stylet Left ventricular vent should consist of round tipped dual lumen tube with lateral eyes, suture collars & proximal funnel connectors used for emptying the Left Ventricle for clearer view during surgery. All sizes- neonatal, pediatric, adult 84 Antegrade Ostial Cardioplegia Cannula - All Size: Antegrade-cardioplegia cannula should be made of soft 100% silicone conduit with distal bulbous end & should have luer lock connector at the proximal end for administration of cardioplegia solution into the coronary ostia. Sizes: 3.5, 4, 4.5, 5, 5.5, 6 mm. 85 Antegrade Ostial Cardioplegia Cannula- Neonatal Antegrade-cardioplegia cannula should be made of soft 100% silicone conduit with distal bulbous end & amp; should have luer lock connector at the proximal end for administration of cardioplegia solution into the coronary ostia, suitable for doing neonatal arterial switch surgery 86 Cardioplegia Cannula Size Infant: Cardioplegia cannula should be made of soft 100% silicone & should be tapered conduit with distal open tip having adjacent lateral eyes, followed by a flange for secure positioning. It should have proximal luer lock & a SS needle with hub. Size: Infant. 87 Arterial cannula for arch cannulation Sizes 20FR -24 Fr. Should have elongated one piece wire wound body with radiopaque suture ring and dilator with depth markings 88 Axillary artery one piece cannula with central arterial pressure measurement Sizes 18 Fr.-24Fr. Should have elongated one piece wire wound body with radiopaque suture ring and dilator with depth markings. Should have integrated pressure monitoring port at tip 89 One piece Pediatric Aortic cannula Vented Should be beveled with thin wall tips and should be elongated one piece wire wound body. Size 6FR-16 Fr. 90 Straight Tip Arch cannula Sizes 8Fr-24 Fr vented and Non vented; Pediatric and Adult Should be beveled thin wall tips attached to tapered cannula bodies. Should be available in pediatric and adult sizes. 91 Angled tip Arterial cannula Should be beveled thin wall tips attached to tapered cannula bodies. Should have kink resistant wire wound bodies. Sized 8 Fr - 24 Fr 92 Arterial cannula angled with diffused flow tip Sizes 18 Fr-24Fr Should be one piece wire wound body with integrated flutes for diffused flow. 93 Femoral one piece Arterial and venous cannula kit Sizes 8-21 Fr. arterial and 8-29 Fr. Venous cannula Should be one piece wire wound body. 94 Femoral Multistage venous cannula Sizes: 29/29/29 Fr and 29/46/37 Fr Should be one piece wire wound multiple side holes body with percutaneous kit. 95 Standard insertion kit for femoral cannulation a. Kit for femoral cannulation should contain 12-14 Fr, Scalpel # 11 blade, Introduce needle 18 ga, vessel dilator 8-10 Fr, vessel dilator Guidewire .038 in X 180 cm, catheter tip , Syringe 96 Carpentier Bi-caval femoral venous cannula Sizes : 24/29 Fr, 30/33Fr Should have wire wound kink resistant two stage design. 97 Single stage venous cannula with Metal tip Sizes 12-31 Fr Should have kink resistant wire wound taper body with beveled metal tip. 98 Single stage Venous cannula with right angle Sizes 12-40 Fr Should have kink resistant wire wound taper body with tapered multiport tips. Should be right angled with plastic tip. 99 Single stage straight venous cannula malleable Sizes 12-40 Fr Should have kink resistant malleable wire wound taper body with tapered multiport tips 100 Double-stage venous cannula round and oval shape Should be two-stage cannula with oval body in various sizes. Should be two-stage cannula with round body in various sizes. Should have cannula body with thin walled with depth markings. Sizes 28/36,36/46,32/46, 36/51, 32/40, 36/46 Fr. 101 Three stage venous cannula Should be three stage venous cannula for Vacuum Assisted Venous Drainage(VAVD)/Kinetic Assisted Venous Drainage(KAVD). Sizes 29/29/29 Fr 29/46/37 Fr 102 Multiple Stage Venous cannula Should have polyurethane wire wound body with radiopaque markers and multiple holes at distal end. Sizes 23 Fr and 29 Fr 103 Aortic root cannula Should have radiopaque tips attached to clear PVC bodies. Additional features: aortic root pressure monitoring and left heart venting. Can be used to aspirate air emboli as well administer cardioplegia. Sizes 4 Fr-11 Fr 104 Aortic root cannula with Vent line Should have radiopaque tips attached to clear bodies with separate vent line. Sizes 5 Fr-11 Fr 105 Aortic root cannula pediatric Neonatal Sizes 4 Fr Should be able to aspirate air from Aorta, Should have radiopaque tip and standard 50.5 in length or a shortened 2.5 in. 106 Cardiopleiga needles Should have stainless steel tip with plastic depth stop, Needle should be attached to Flexible PVC tubing which should include a drape clamp and female luer. Neonatal, Pediatric and Adult. Sizes: 5Fr -8 Fr 107 Silicon Ostial cannula for continuous perfusion Should have a silicon body with soft bulb shaped tips, should have a female luer connection site. Sizes 15Fr,17Fr and 20 Fr 108 Ostial perfusion cannula with basket tip and soft convex tip Should have flanged, radiopaque basket tips/soft tips attached to malleable stainless steel shafts. Sizes 10 Fr, 12 Fr and 14 Fr. 109 Minimally invasive antegrade Aortic root cannula Should have more than 30 cm long body to allow insertion during MICS 110 Minimally invasive retrograde cardioplegia cannula with deflecting tip Should have tip deflecting models for sinus placement through thoracotomy should be able to allow minimum 10mm sweep. Should be auto/ manual inflatable. Sizes 13 and 15 Fr 111 Retrograde cardioplegia cannula with Auto inflate Should have silicon/ PVC bodies with auto inflatable cuff and pressure monitoring lines; should have multiport tip/ integral stopcock. Sizes 13 Fr and 15 Fr 112 Multiple perfusion set Should have silicon/ PVC bodies with auto inflatable cuff and pressure monitoring lines; should have multiport tip/ integral stopcock. 113 Distal perfusion kit Should be able to perform simultaneous perfusion of Aortic root and upto 3 or more vein grafts 114 Left Heart Vent Catheters Should be of PVC or silicon, could be used for direct and indirect venting, should have perforated tip, malleable bodies with depth mark. Should have a choice of either PVC or Silicone along with straight body with depth marking. All vents should terminate with a vented or non vented ¼”connector. Sizes 10 Fr,13Fr,15Fr,16Fr,18Fr,20Fr,24Fr 115 Pericardial Sumps Sizes 20 Fr Should feature a fluted tip, should be encased in a stainless steel spring and should have weight at the end. 116 Intra-cardiac sump Size 20 Fr Should feature a perforated pool tip to maximize suction and minimize tissue trauma. The tip design should be ideal for atraumatic suction within the heart chambers. 117 Suction Tube Sizes 6 Fr,10Fr and 20 Fr Should have variety of cardiac suction tubes, intracardiac suction tubes & rigid suction tubes. 118 Micro Suction tubes Sizes 9 Fr Should have a vacuum control port, malleable shaft, should equipped with a length of tubing and clamp terminating with a ¼ in (0.64cm) connector 119 Macro Rigid suction tubes Sizes 20 Fr Should have tip made up of stainless steel, should have fluted pool tip to maximize suction and minimize tissue trauma, should offer gentle suction. 120 PA vent cannula Should have a soft, pliable tip with female luer end; should have movable depth marker and an introducer needle should be included. 121 Tourniquet Sets Should have color coded tubes with varying lengths for adults and pediatric, should have wire snares included with the tube set. Sizes 12 Fr, 16 Fr and 19 Fr. 122 Vessel cannula with and without valve Should have clear and radiopaque bodies. These should terminate with a female luer. Should have tips in various sizes and shapes. Sizes 2mm,3mm, 4mm 123 Coronary Arteriotomy Cannula Should have polyurethane tube with a bulb shaped tip connected to winged female luer. Sizes1mm,1.25mm, 1.5mm, 1.75mm, 2mm, 2.5mm 3mm, 124 Rapid priming set Length 35cm and 40cm These should facilitate the transfer of fluid during the priming of the circuit. Should have large bore spikes attached to flexible tubing with a clamp. Should terminate with either an open end tube or a male luer. 125 Rapid Priming “Y” Set Length around 1 m These should facilitate the transfer of fluid during the priming of the circuit. Should have large bore spikes attached to flexible tubing with a clamp. Should attach to a “ Y” adapter with a length of tubing and another clamp. 126 Adult Oxygenator Priming volume should be less than 300 ml. Blood flow range should be 0-7lts/min. Oxygen transfer should be at least 400ml/min. Heat exchange efficiency should not be less than 0.50. Housing material should be of polycarbonate. Surface area of the fibers should be from 1.8m 2 to 2.4m 2 Heat exchanger should be made of stainless steel and surface area should be approx. 20cm 2 Blood inlet port (from pump) 3/8 Blood outlet port 3/8 Cardioplegia port ¼ Gas Inlet port 1/4 Gas Outlet port 1/4 Water Ports ½ Maximum Pressure Blood inlet 1000 mmHg water Inlet 42 PSI Blood storage capacity of hard shell reservoir should be approx. 4000ml Minimum operating volume of reservoir should be 200ml. Hard shell reservoir should have cardiotomy filter and de-foaming part Hard-shell reservoir should have venous filter with pore size 452mm The hard-shell reservoir should have Venous blood inlet port ½ Blood outlet port (to pump) ⅜ Suction ports (six) ¼ Water Inlet 42 PSI Vertical port to CR Filter ¼ Quick Prime port ¼ Auxiliary port ¼-⅜ Sustainable negative pressure should be 15010mmHg 127 Pediatric Oxygenator • Priming volume should be less than 150ml. Blood flow range should be 0.40.01ltrs/min. Oxygen transfer should not be less than 250ml/min. Pressure drop should be least-up to 100mmHg or less. Heat exchange efficiency should not be less than 0.65. Housing material should be of polycarbonate. Surface area of the fibers should be approx 1.0m 2 . Heat exchanger should be made of stainless steel and surface area should be approx 1300cm 2 . Blood inlet port 3/8 Blood outlet Port 3/8 Cardioplegia port 1/4 Gas Inlet Port 1/4 Gas Outlet port 1/4 Water Port ½ Maximum Pressure Blood inlet 1000mmHg, Water Inlet 42 PSI Blood Storage capacity of hard shell reservoir should be max 3000ml. Minimum operative volume of hard shell reservoir should be 100ml. Hard-shell reservoir should have cardiotomy filter and defoaming part. Hard-shell reservoir should have venous filter with pore size should be 20mm The hard-shell reservoir should have Venous blood inlet port 3/8 rotatable Blood outlet port ( to pump) 3/8 Suction port(six) ¼ Vertical port to CR filter 3/8 Quick prime port ¼ Auxiliary port 3/8 Water Inlet 42 PSI 128 Neonatal Oxygenator Blood flow range should be 0.1 – 2 liters/min. Priming Volumes should be around 40 ml. Oxygen transfer should be minimum 100 ml/min. Pressure drop should be least up to 100mmHg or less. Heat exchange efficiency should not be less than 0.65. Housing material should be of polycarbonate. Surface area of the fibers should be ≈0.5m 2 and material should be micro porous polypropylene. Heat exchanger should be made of stainless steel and surface area should be approx 0.035m2 . Blood inlet port (from pump) ¼ Blood outlet port ¼ Luer port (for recirculation or blood cardioplegia) one luer lock on blood outlet Gas inlet port ¼ Gas outlet port 5/16 Water ports ½ Maximum pressure Blood inlet 1000mmHg Blood storage capacity of hard shell reservoir should be 1000ml Minimum operating volume of hard-shell reservoir should be 15ml Hard-shell reservoir should have cardiotomy filter and defoamer The hard-shell should have Venous blood inlet port ¼ Blood output port (to pump) ¼ Suction port (five) 3/16 Quick prime port ¼ Vent port ¼ Auxiliary port ¼-3/8 Maximum sustainable negative pressure in reservoir -150mmHg Water inlet 2Kgf/cm 2 129 Pediatric Arterial Filter with Bypass Loop The Arterial Filter should be for pediatric use. Priming volume should not be more than 90ml Filter pore size should be 30- 40 micron. The outlet and inlet blood posts should be 3/8 or ¼”.The filter should allow maximum blood flow rate of 5.0L/min. The filter should be provided with a bypass loop at the inlet and outlet port. 130 It should have priming volume less than 50 ml. Blood flow rate should be between 0-600 ml/min Filter screen should be around 100 um. Inlet connection should be ¼and outlet connection should be 3/16. Heat exchange surface area should be ≈0.20m2 . Heat exchange should be of stainless steel corrugated/ convoluted pipes. Bubble trap should be integrated for highly efficient de-bubbling Integrated by pass manifold for easy de-bubbling Exchangeable water in /water out Blood flow path bottom up It should have a Stopcock Prime/ Perfusion for easy priming. It should have tip in the surgeon pack so that it can be connected to cardioplegia cannula. It should be available in 4:1 configuration. 131 Cardioplegia Heat Exchanger (BCD) del Nido It should have priming volume less than 50 ml. Blood flow rate should be between 0-600 ml/min Filter screen should be around 100 um. Inlet connection should be ¼and outlet connection should be 3/16. Heat exchange surface area should be ≈0.20m2 . Heat exchange should be of stainless steel corrugated/ convoluted pipes. Bubble trap should be integrated for highly efficient de-bubbling Integrated by pass manifold for easy de-bubbling Exchangeable water in /water out Blood flow path bottom up It should have a Stopcock Prime/ Perfusion for easy priming. It should have tip in the surgeon pack so that it can be connected to cardioplegia cannula. It should be available in 1:4 configuration 132 Pedaitric Hemo Concentrator It should have priming volume approx 35ml. Effective surface area of the Fibers should be approx 0.5m2 . Blood port should be ¼with Luer locks. Filtrate port should be ½. Maximum Trans-membrane Pressure should be 500mm Hg. It should have tubing lines along with reservoir Bag. 133 Adult Hemo Concentrator The priming volume should be 70 ml Effective surface area of the fibers should be ≈1m2 . Blood port should be ¼ With Luer locks Filtrate port should be ½ (1/4adapter). Blood flow range should be 100-500ml. Maximum Trans-membrane pressure should not be more than 500mm Hg. It should have tubing with reservoir bag. 134 Neonatal Hemo Concentrator It should have priming volume less than 20 ml. Membrane surface area should be ≈0.2m2 . Max Membrane pressure should not be more than 600mm Hg. Capillary wall thickness should be ≈50um. It should have inlet/outlet lines, male luer lock connections, filter safety cap, filtrate line and additional filtrate bag (200ml). 135 Adult Custom Tubing Pack Custom Tubing Pack Adult. Custom Tubing Pack with arterial filter with PVC tubing medical grade -6 as per NEIGIRHMS CTVS design. Filter/Tubing should be CE/USFDA Approved. 136 Small Adult Custom Tubing Pack Custom Tubing Pack Small Adult. Custom Tubing Pack with arterial filter with PVC tubing medical grade -6 as per NEIGIRHMS CTVS design 137 Pediatric Custom Tubing Pack Custom Tubing Pack Pediatric. Custom Tubing Pack with arterial filter with PVC tubing medical grade -6 as per NEIGIRHMS CTVS design 138 Neonatal Custom Tubing Pack Custom Tubing Pack with neonatal arterial filter with PVC tubing medical grade- 6Filter/Tubing should be CE/USFDA Approved. 139 Small Neonatal Custom Tubing Pack Custom tubing packs with 3/16arterial and ¼ venous lines for small neonates. Made from medical grade-6 PVC. Filter/Tubing should be CE/USFDA approved 140 Extra Corporeal Membrane Oxygenator (Neonatal) ECMO should have a validation for 14 days and should be phthalate free (NO DOP). Membrane used should be of polymethylpentene fibers. Priming volume should be 100 ml. Should have contact surface area ≈0.70 square meters. Should cater for blood flow from 0.2 to 1.5 L/min. Heat exchanger surface area should be ≈0.4 square meter. Heat Exchanger performance factor should be of 0.77 ( 1.5 liter /min). Oxygenator and tubing should have coating of Phosphorylcholine. Inlet and outlet connector preferred is 1/4 (6.35 mm). 141 Extra Corporeal Membrane Oxygenator (Paediatric) ECMO should have a validation for 14 days and should be phthalate free ( NO DOP). Membrane used should be of polymethylpentene fibers. 142 Should have priming volume 200 ml. Should have contact surface area of around1.4 square meters. Should cater for blood flow from 0.3 to 4 liter /min. Heat exchanger should have surface area of ≈0.8 square meter. Heat exchanger performance factor should be of ≈0.6 ( @ 4 liter /min). Oxygenator and tubing should have coating of Phosphorylcholine(PC). Inlet and outlet connections preferred is 3/8(9.53 mm) 143 Extra Corporeal Membrane Oxygenator (Adult) ECMO should have a validation for 14 days and should be phthalate free (NO DOP). Membrane used should be of polymethylpentene fibers. Should have priming volume of≈250ml. Should have contact surface area of 1.7-1.9 square meters. Should cater for blood flow from 0.4 to 7 liters/ min. Heat exchanger should have surface area of ≈0.8square meter. Heat exchanger performance factor should be ≈0.6 ( @ 4 liters /min). Oxygenator and tubing should have coating of Phosphorylcholine.(PC) Inlet and outlet connections preferred is 3/8 (9.53 mm) 144 Adult Oxygenator (Integrated with arterial filter & heat exchanger) Oxygenator should have integrated arterial filter with cardiotomy/ venous reservoir.• Should have integrated arterial filter with self venting technology.• Heat exchanger surface area should be no more than 0.2m 2 .• Venous filter should be 50micro meter.• Priming volume should not be more than 300ml.• Blood flow range should be 0.5 to 7 LPM.• Heat exchange efficiency should not be less than 0.50 at max flow.• pressure drop should be minimum, up to 110 mmHg or less.• Arterial filter should be 35micron meter.• Membrane surface area should be 2-2.5 m2 . 145 Small Adult Oxygenator (Integrated Filter and Heat Exchanger) Oxygenator should have integrated arterial filter with cardiotomy/venous reservoir. Should have integrated arterial filter with self venting technology. Heat exchanger surface area should be no more than 0.14m 2 . Venous filter should be 50micro meter. Priming volume should not be more than 150ml Blood flow range should be 0.5 to 5 LPM. Heat exchange efficiency should not be less than 0.5 max flow @ 5 LPM Pressure drop should be minimum up to 110 mmHg or less. Arterial filter should be35micro meter. 146 Paediatric infant Oxygenator (Integrated Filter and Heat Exchanger) Oxygenator should have integrated arterial filter with cardiotomy/ venous reservoir. Should have integrated arterial filter with self venting technology. Heat exchanger surface area should be no more than 0.035m 2 . Venous filter should be 50micro meter. Priming volume should not be more than 45ml. Blood flow range should be 0-1.5Ltrs/min. Heat exchange efficiency should not be less than 0.6 at max flow. Pressure drop should be minimum up to 100mmHg or less @ 1.5 LPM Arterial filter should be35micro meter. 147 Oxygenator infant- Pediatric Infant- paeditric oxygenator totally coated phosphorylcholine coating, prime volume 99ml, surface0.84m2, blood flow 0.5-3.0 l/min 148 Oxygenator infant- Pediatric with filter Infant- paeditric oxygenator totally coated phosphorylcholine coating with modular cascade filtration (with interated arterial filiter) prime volume 130ml, surface0.84m2, blood flow 0.5-3.0 l/min 149 Oxygenator Adults The Lowest Prime Adult Oxygenator phosphorylcholine coating, Oxygenator is specially designed to have the lowest priming volume (190 ml) surface area 1,35m2, max blood flow 7,0 l/min with low contact surface area, combining excellent gas transfer performances with clinical flexibility for small adult and adult Patients. OPTIMAL ERGONOMIC DESIGN FOR PERFUSION COMFORT. Improved ease of use thanks to the top venous inlet port and a large variety of connector adapters for enhanced customization capabilities. 150 Cardioplegia Delivery System The Cardioplegia Heat Exchanger aims to meet all the performance expectations with the following product features: Priming between 20-30 ml k) A flow dynamic engineering system which can effectively mix the blood and crystalloid solution to the desired preparations ( 1:4& 4:1 ratios) Complete blood for warm shot also Allows delivery in any ratio either Delnido 4 part Crytalloid:1 blood) or Microplegia(1 part crystalloid and 4 part blood) Ports available for infusion, sampling, temperature reading, and the inlet/outlet connector easily adapt 1⁄4’’ tubes for infant, paediatric and adult patient use. While priming, the perfusionist can easily purge air through the one port between the inlet and outlet with minimal holdup volume. The pleated anodized aluminium heat exchanger hasminimum surface area ,delivery froth –free, to allow the excellent mixing of blood with cardioplegia. An air trap column at the entry port provides additional safety by trapping any micro air bubbles going out. Thebottom-in,top-outflowpathenablescompletedrainagewith minimal blood holdup volume. The PVC recirculation lines are preconnected with their respective connectors to ensure easy setup and use. Available individually packed or preconnected with recirculation line Product has double protective packing that can be pealed easily when assembling A cardioplegia Heat exchanger which can infuse the contents to the patient as and when the surgeons wants instantly without any delay . An in-built 200 μ Filter to prevent micro air bubbles. 151 Membrane Oxygenator Efficient Heat Exchanger with Surface coating with Hardshell Venous Reservoir, Cardiotomy Filter and Integrated Arterial Filter. 7 Ltr Recommended Max Blood flow rate: 5001 to 8000 ml/min, Static priming vol: 180 to 350 ml, Maximum Hardshell Reservoir Capacity: 4000 to 4500 ml, Minimum Hardshell Reservoir Capacity: 200 to 300ml, Venous Reservoir filter: 20 to 47 μ, Suction inlet No.: minimum 4, Filtered quick prime No.: minimum 1, Filter luer No.: minimum 2, Venous blood flow: 7000 to 8000 ml/min, Membrane Surface area: 1.8 to 2.5 m². Specifications of Arterial Filter: Maximum Blood flow rate: 6 to 8 lit/min, Low Priming Volume, Inlet and Outlet 3/8 For Adult 152 Membrane Oxygenator Efficient Heat Exchanger with Surface coating. Small Adult 5 Ltr Cardiotomy filter and integreated arterial filterRecommended Max Blood flow rate: 4000 to 5000 ml/min, Static priming vol: 120 to 175 ml, Maximum Hardshell Venous Reservoir Capacity: 3000 to 4200 ml, Minimum Hardshell Reservoir Capacity: 70 to 150 ml, Venous Reservoir filter: 20 to 47 μ, Suction inlet No.: minimum 4, Filtered quick prime No.: minimum 1, Filter luer No.: minimum 2, Venous blood flow: 4000 to 5000 ml/min, Membrane Surface area: 1.0 to 1.5 m². Specifications of Arterial Filter: Maximum Blood flow rate: upto 5 lit/min, Low Priming Volume, Inlet and Outlet 3/8 For Small Adult CE Approved 153 Membrane Oxygenator Efficient Heat Exchanger with Surface coating. Ped. 4 Ltr Cardiotomy filter Recommended Max Blood flow rate: 2000 to 3000 ml/min, Static priming vol: 90 to 145 ml, Maximum Hardshell Reservoir Capacity: 1600 to 3000 ml, Minimum Hardshell Reservoir Capacity: 15 to 70 ml, Venous Reservoir filter: 20 to 47 μ, Suction inlet No.: minimum 4, Filtered quick prime No.: minimum 1, Filter luer No.: minimum 2, Venous blood flow: 2000 to 3000 ml/min, Membrane Surface area: 0.6 to 1.5 m². Specifications of Arterial Filter: Maximum Blood flow rate: 3.2 to 5 lit/min, Low Priming Volume, Inlet and Outlet 3/8 For Paediatric CE Approved 154 Membrane Oxygenator Efficient Heat Exchanger with Surface coating with Hardshell Venous Reservoir, Cardiotomy Filter and Integrated Arterial Filter. Neonatal 1.5 Ltr Recommended Max Blood flow rate: 800 to 2000 ml/min, Static priming vol: 35 to 70 ml, Maximum Hardshell Reservoir Capacity: 700 to 1500 ml, Minimum Hardshell Reservoir Capacity: 15 to 30 ml, Venous Reservoir filter: 20 to 47 μ, Suction inlet No.: minimum 4, Filtered quick prime No.: minimum 1, Filter luer No.: minimum 2, Venous blood flow: 800 to 2000 ml/min, Membrane Surface area: 0.3 to 0.7 m². Specifications of Arterial Filter: Maximum Blood flow rate: 0.7 to 2.5 lit/min, Low Priming Volume, Inlet and Outlet 1/4 For Infant and Neonatal CE Approved 155 Arterial Perfusion Cannulae Adult. Wire reinforced beveled tip Size 18Fr, 20Fr, 22Fr and 24 Fr. Overall length should be approx.15cm with suture bump 156 Arterial Perfusion Cannulae Pediatric Sizes: 8Fr, 10Fr, 12Fr,14Fr and 16Fr. Wire reinforced bevel tip. Overall length 18cm with suture bump 157 Venous Cannulae Single Stage. (neonate) Thin Flexible wire reinforced straight open light house tip. Overall length approx.28cm with ¼ acceptance size 12Fr, 14Fr and 16Fr 158 Venous Cannulae Single Stage(pediatric) Thin Flexible wire reinforced straight open light house tip. Overall length approx. 35cm with ¼and 3/8 acceptance Size 18Fr, 20Fr, 22Fr and 24Fr. 159 Venous Cannulae Single Stage(small adult) Thin flexible wire reinforced straight open lighthouse tip. Overall length 35cm with 3/8 acceptance Size 26Fr and 28Fr. 160 Venous Cannulae Single Stage(adult) Thin Flexible wire reinforced straight open lighthouse tip. Overall length should be approx.40cm with 3/8 acceptance Size 30Fr, 32Fr, 34Fr, 36Fr, 38Fr and 40Fr. 161 Venous Cannulae Right Angled Wire reinforced 900 angled plastic tip 10Fr, overall length approx.28cm and ¼ acceptance 162 Venous Cannulae Right Angled Wire reinforced 90 0 angled plastic tip 12Fr, 14Fr and 16Fr. Overall length should be approx. 33cm with ¼& 3/8 acceptance 163 Venous Cannulae Right Angled Wire reinforced 90 0 angled plastic tip 22Fr, 24Fr and 28Fr. Overall length should be approx.38cm with 3/8 acceptance 164 Retrograde Cannula catheter Self-inflating smooth balloon with preshaped stylet and handle 14Fr. Overall length should be approx. 27cm & should have 18-20 mm sized smooth balloon. 165 Aortic Perfusion Cannulae; Wire reinforced dispersion tip Sizes: 21Fr and 24Fr overall length approx.35cm and vent. 166 Dual Stage Venous Cannulae; Wire reinforced 32/40Fr and 36/51Fr. Overall length should be approx. 40cm and ½acceptance. 167 Femoral Arterial Cannulae; Wire reinforced overall length should be 19.5.2 cm with ¼ vented connector sizes: 8Fr, 10Fr, 12Fr and 14Fr. 168 Femoral Arterial Cannulae; Wire reinforced overall length should be approx. 24cm with 3/8 vented connector sizes: 14Fr, 16Fr, 18Fr and 20Fr. 169 Femoral Venous Cannulae; Wire reinforced overall length should be approx. 24cm with ¼ non vented connector. Sizes 8Fr, 10Fr, 12Fr and 14Fr. 170 Venous Femoral Cannulae; Wire reinforced overall length should be 752 cm with 3/8 non vented connector sizes 18Fr, 20Fr, 22Fr,24Fr and 28Fr 171 Antegrade Cardioplegia Cannulae with vent 12/14/16 Fr. with vent and without vent. 172 Antegrade Cardioplegia Cannulae without vent 12/14/16 Fr 173 Disposable connector all sizes: Y/ Straight with and without leur lock ½*3/8 st, ½*1/2 st, 3/8*3/8*1/2 Y, 3/8*3/8*3/8 Y, 3/8*3/8*1/4 Y, 3/8*1/4*1/4 Y, ¼*1/4 st, ¼*1/4*1/4 Y, 3/8*1/4 st, ¼*1/4 st, ¼*1/4*1/4 Y, ¼* 3/16 st inch, ¼ male Leur with side port, ¼*1/4 st with Leur lock, 3/8*3/8 inch male leur lock. 174 Disposable Single Tubing Sizes (½,⅜,¼,3/16 inch) 175 Wire enforced Arterial Cannula (6 Fr to 20 Fr) 176 Intra-Aortic Balloon Fiber Optic Catheters Sizes 30 cc (Height 147-162 cm, BSA <1.8 m2), 40 cc (Height 162-182 cm, BSA >1.8 m2) Designed to capture and transmit the high-fidelity AP signal at the speed of light; Abrasion –resistant: Should have Cardiothane II abrasion resistant membrane with hydrophilic coating. 177 Pruitt andPruitt-Inahara Shunts Sizes 3Fr to 12 Fr 178 Long, Flexible, wire-enforced cannula for ascending aortic & arch cannulation with Obturator 179 Long Flexible, wire-enforced cannula for ascending aortaarch cannulation with guide wire. 180 Long Flexible wire enforced cannula for ascending aorta and arch cannula angled with side holes. 181 Balloon tip antegrade cerebral perfusion cannula. 8, 10, 12 Fr size 182 Hemofilter Adult 0.8 m2 183 Hemofilter Ped. 0.3m2 184 Custom Tubing Pack Adult Made from non-toxic medical grade PVC tubing . It is used exclusively in combination with heart lung machine and other devices of the system such as oxygenator and blood cardioplegia delivery system. Options of clear or colorful stripes tubing i.e. RED/BLUE/YELLOW/GREEN and with arterial line filter and withouT filter is available. 185 Custom Tubing Pack Semi Adult Made from non-toxic medical grade PVC tubing . It is used exclusively in combination with heart lung machine and other devices of the system such as oxygenator and blood cardioplegia delivery system. Options of clear or colorful stripes tubing i.e. RED/BLUE/YELLOW/GREEN and with arterial line filter and withour filter is available. 186 Custom Tubing Pack Paediatric Made from non-toxic medical grade PVC tubing . It is used exclusively in combination with heart lung machine and other devices of the system such as oxygenator and blood cardioplegia delivery system. Options of clear or colorful stripes tubing i.e. RED/BLUE/YELLOW/GREEN and with arterial line filter and withour filter is available 187 Custom Tubing Pack Neonatal Made from non-toxic medical grade PVC tubing . It is used exclusively in combination with heart lung machine and other devices of the system such as oxygenator and blood cardioplegia delivery system. Options of clear or colorful stripes tubing i.e. RED/BLUE/YELLOW/GREEN and with arterial line filter and withour filter is available. 188 Blood Cardiolplegia Delivery Set Adult Adult and Paediatric Delivery system configurations Flow engineer with Axial, non turbulent, eddy free design prevents bubble formation and eliminates need for downstream filters Shortest blood flow path over smooth surfaces, yet best cooling efficiency Core flow without thinning of blood , reduces stress Priming Volume is just 40 ML, Mixing propositions of blood and cardioplegia 1:1,2:1 and 4:1 189 Blood Cardiolplegia Delivery Set Paediatric Adult and Paediatric Delivery system configurations Flow engineer with Axial, non turbulent, eddy free design prevents bubble formation and eliminates need for downstream filters Shortest blood flow path over smooth surfaces, yet best cooling efficiency Core flow without thinning of blood , reduces stress Priming Volume is just 40 ML, Mixing propositions of blood and cardioplegia 1:1,2:1 and 4:1 190 Hemofilter Adult Surface Area (Sq.m): 0.8 Priming Volume (cb.m) : 58 Max. Trans pre (mm/Hg) : 500 Max. Flow (ml/min) : 150 Blood Inlet & Outlet: 1/4 191 Hemofilter Paediatric Surface Area (Sq.m): 0.4Priming Volume (cb.m) : 58Max. Trans pre (mm/Hg) : 500Max. Flow (ml/min) : 150Blood Inlet & Outlet: 1/4 192 Pressure Transducer Kit Double Consists of high pressure monitoring lines , transducer domes with built in flushing device and three way stop cock. Close system design reduces the risk of leakage and infection to operators. Consistent and accurate reading during monitoring. 193 Aortic Cannula Reinforced straight and Angled One piece body with straight or curved tip available with vented or non-vented connector. An adjustable or xed depth ring together with tip and depth line permits precise position of all cannula. Size 12, 14,16,18,20,22,24 194 Aortic Cannula non-reinforced St. One piece body with straight or curved tip available with vented or non-vented connector. An adjustable or xed depth ring together with tip and depth line permits precise position of all cannula. Size 12, 14,16,18,20,22,25 195 Aortic Cannula non-reinforced Curved Plastic Tip One piece body with straight or curved tip available with vented or non-vented connector. An adjustable or xed depth ring together with tip and depth line permits precise position of all cannula. Size 12, 14,16,18,20,22,26 196 Aortic Cannula non-reinforced Curved Metal Tip One piece body with straight or curved tip available with vented or non-vented connector. An adjustable or xed depth ring together with tip and depth line permits precise position of all cannula. Size 12,14,16,18,20,22,27 197 Venous Cannula straight One piece body with wire reinforced walls and MULTIPORT LIGHTHOUSE TIP. Sizes available: 12 FR-38 FR. 198 Venous Cannula angled metal tip Venous cannula with right angled metal tip features kink resistant wire reinforced bodies. with beveled angled metal tip. This construction allows for higher flow rates with minimum pressure di erential. Metal tip orientation permits precise positioning of the cannula. Sizes 12-38 Fr 199 Two Stage Venous Cannula These cannulae feature multiport tips with atrial baskets and kink- resistant, wirewound bodies with depth markings. The oval body presents a lower profile in the surgical field. All Sizes 200 Arterial Line Filter Filter : 40 micron. Flow : 7 LPM. Priming : 179 ml. Port: 3/8 201 Arterial Line Filter Filter : 40 micron. Flow : 5 LPM. Priming : 90 ml. Port: 3/8 202 Arterial Line Filter Filter : 40 micron. Flow : 3.2 LPM. Priming : 35 ml. Port: 1/4 203 Aortic root Cannula / Antegrade These cannulae feature radiopaque tips attached to clear bodies with separate vent lines. Additional features available with these cannulae. include aortic root pressure monitoring and left heart venting. All cannulae are supplied with a stainless steel introducer needle. Sizes 12,14,16,18 204 Cardiac Sump with steel tube tip This sump features a weighted perforated pool tip to minimize the possibility of tissue occlusion while maintaining an opportunity for drainage. The perforated steel tube tip is inside the tubing that terminates with a 1/4 inch (0.64 cm) connector. Adult, Paed. Infant 205 L. V. Vent with stylet These vent catheters are for direct and indirect venting of the left ventricle and feature perforated tips. Catheter material is PVC, along with straight, preformed, or malleable bodies with depth markings. These vents are available in pediatric and adult sizes. Straight body models come with a malleable or stiff guidewire style introducer for easy insertion and placement. All vent catheters terminate with a vented or non-vented 1/4 inch (0.64 cm) connector. 12, 14, 17, 18, 20 Fr 206 Femoral Aortic Cannula Features an introducer with blunt tip configuration that allows safe insertion for additional arterial access sites such as the aorta, axillary and subclavian A lock feature reduces push-back of the introducer during insertion Vent cap reduces back-bleed when no guidewire is used in the procedure Depth markings aid in placement 8 to 24 Fr 207 Femoral Venous Cannula single stage Venous femoral cannulae, designed to drain from superior and inferior vena cava, available in given sizes , with full flow drainage capability. A high quality soft introducer features a smooth transition to the cannula to improve insertion and reduce vascular damage. Available for percutaneous insertion via Seldinger technique. 16 to 30 FR 208 Femoral Venous Cannula three stage Multiple Stage Femoral Venous cannulae, designed to drain from superior and inferior vena cava, available in given sizes , with full flow drainage capability. A high quality soft introducer features a smooth transition to the cannula to improve insertion and reduce vascular damage. Available for percutaneous insertion via Seldinger technique. 16,18,24,26,28 Fr 209 Cytokine Adsorber Maximum Blood Flow Rate: 700 mL/min Minimum Blood Flow Rate: 100 mL/min. Blood Priming Volume: 150 mL Adsorbent Material should ideally be crosslinked Divinylbenzene or polyvinylpyrrolidone. Should be compatible with CRRT, VV and VA ECMO Should be FDA approved 210 Prosthetic Cardiac Valves, Rings and Composite Conduits 211 Complete Bovine Aortic Pericardial Valve Should be bio engineered, computer optimized to ensure uniform thickness of leaflets and have tissue deflection test to ensure uniform flexibility in all three leaflets. Long term clinical data should be available, establishing more than at least 20 years expected durability in clinical study, long term follow up data on hemodynamic performance establishing consistency in low gradients. Should have standard low- pressure fixation & adequate treatment of tissues to preserve natural leaflet dimensionality & flexibility, while extracting phospholipids. Should have more than 20 yrs. Experience globally. Scalloped sewing ring for Aortic annulus conformity is preferable. Aortic Sizes 19/21/23/25/27 Should be FDA APPROVED E.g.; SJM- Trifecta / SJM Biocor / Edwards Inspiris / Edwards Perimount / Edwards Magna / Edwards Magna Ease / Medtronic Avalus / Medtronic Avalus Ultra 212 Complete Bovine Mitral Pericardial Valve Bio- engineered: Computer optimized to ensure uniform thickness, with Tissue deflection tests to ensure uniform flexibility in all three leaflets, unique design mounting feature such as flexible stent& optimal tissue stent compatibility for greater reliability. Long term clinical data available, establishing more than & consistency in hemodynamic performance. Low-pressure fixation & chemical treatment of tissue to preserve natural leaflet dimensionality & flexibility, while extracting maximum phospholipids. Should have more than 20 yrs experience globally. Should have convenient deployment and LVOT markers for ease of Implantation at Mitral position. MITRAL SIZE 25/27/29/31/33 Should be FDA APPROVED 213 Complete Bovine Mitral Supra Annular Pericardial Tissue Valve Bio mechanically engineered tissue valve with three leaflets of identical thickness, and identical Flexibility. Should be a True supra annular valve with a saddle shaped sewing ring with posterior flexibility & anterior rigidity for optimal conformity at Mitral position, Should have LVOTO markers for correct orientation, preventing any LVOT obstruction, with convenient deployment system to prevent suture looping and ease of deployment. Low profile tissue valve with asymmetrical sewing ring should preserve sub valvular apparatus and prevent LV impingement. Should have Tissue treatment to irreversibly extract both calcium binding sites Phospholipids, residual glutraldehyde, should have a flexible stent & optimal tissue stent compatibility for greater reliability. Clinical data to be available establishing long term durability and consistency in hemodynamic performance. Sizes: 25 to 33mm Should be FDA APPROVED 214 Complete Bovine Aortic Supra Annular Pericardial Tissue Valve Bio-mechanically engineered tissue valve with three Leaflets of identical thickness and identical flexibility. Should be a true supra annular valve. Scallop shaped sewing ring for aortic position.Should be Low profile tissue valve. Should have Tissue treatment to irreversibly extract both calcium binding sites phospholipid, and residual glutraldehyde, should have Flexible and Durable Stent. Short term and long term clinical data should be available, establishing Durability & consistency in hemodynamic performance. Should have a sizer (barrel and replica end) for optimum sizing and placement. Size 19 to 29mm Should be FDA approved 215 Complete Bovine Pericardial Low Profile Aortic Tissue Valve Bio-Mechanically engineered tissue valve with three leaflets of identical thickness, and Identical Flexibility.• Should be a true supra annular valve.• Should have a Scallop shaped sewing ring consistent with Aortic annulus.• Should have tissue treatment to Irreversibly extract both calcium binding sites phospholipid residual glutraldehyde,• Should have a flexible stent & optimal tissue stent compatibility for greater reliability.• Short and long term clinical data should be available, establishing Durability & consistency in hemodynamic performance.• Should have Low profile height for optimizing Coronary Ostial &sino- tubular junction clearance. Should have Three Mid commissure markers for correct orientation of the valve.• Should have a slick stent post & stent base allowing ease of implantation in small aortic root.• SIZES: 19/29mm• Should be FDA APPROVED. 216 Tricuspid Repair Ring Sterile double packed tricuspid semi rigid ring with an anterior gap with polyester of PTFE cloth with marking for commissures. 3D waveform shape to restore tricuspid annulus to a systolic position Open segment around anteroseptal commissure to avoid conduction system Sizes 26, 28, 30, 32, 34, 36 mm. 217 Mitral Repair Ring Sterile double packed complete semi rigid ring with polyester or PTFE cloth with marking for commissures. Kidney shaped for mitral position. Anterior saddle and smaller posterior saddle for apposition to the aortic root Cover sizes 26, 28, 30, 32, 34, 36, 38, 40mm 218 IMR annuloplasty ring: Should have a complete rigid ring. To be constructed of a strong, durable alloy. Asymmetrical design to compensate in tethered P2/P3 region Dipped P3 segment to accommodate downward displacement of posterior annulus Should have a increased sewing margin in the P2-P3 region, Should be marked with suture and designed to accommodate a double suture row. Should have a Dipped P3 region to accommodate higher stresses from downward LV displacement. Should have a convenient holder/handle to increase ease of use & operative efficiency Sizes 24,26,38,30,32,34mm 219 3-D Tricuspid Annuloplasty Ring: Should be a rigid annuloplasty ring with three-dimensional shape and with an incomplete ring shape to avoid the sensitive conduction system. Should have a downward angle in septal region to help reduce the stress on sutures and the risk of ring dehiscence. Sizes 26, 28, 30,32,34mm. Should be FDA approved. E.g. Medtronic Contour 3D 220 Artificial Mechanical Heart Valve Bileaflet Mitral Rotatable with handle design, leaflets made up of pyrolytic carbon / standard durable alloy and polyester sewing cuff. Should have low profile height. Should have minimum vertical leaflet exposure to result in NO LVOT obstruction Should have greater posterior wall clearance Wide range of sizes from 23/24mm – 34/37mm Should have both CE and FDA approval E.g. SJM Master / Sorin Carbomedics / ONX 221 Artificial Mechanical Heart Valve Bileaflet Mitral (for supra- annular implant) Rotatable with handle design, leaflets made up of pyrolytic carbon / standard durable alloy and polyester sewing cuff. Should have low profile height. Should have minimum vertical leaflet exposure to result in NO LVOT obstruction Should have greater posterior wall clearance Wide range of sizes from 24 mm – 34 mm Should have both CE and FDA approval SJM /ATS /Sorin Carbomedics 222 Artifical Heart Valve Bileaflet Aortic Rotatable with handle design, leaflet made up of pyrolytic carbon and polyester sewing cuff, with pivot guard design. Should have low profile height. Should have minimum vertical leaflet exposure. Wide range of sizes from 19mm-31mm. Should have both CE and FDA approval SJM Regent / ATS/ Sorin Carbomedics / ONX 223 Artifical heart valve bileaflet Aortic for Supra-annular implant Rotatable with handle design, leaflet made up of pyrolytic carbon and polyester sewing cuff, with pivot guard design. Should have low profile height. Should have minimum vertical leaflet exposure. Wide range of sizes from 16 mm- 28mm Should have both CE and FDA approval E.g. Sorin Tophat 224 Bileaflet Mechanical Aortic Valve with Straight Conduit Should have double velour woven graft. Rotatable with handle design Should be collagen impregnated to control hemostasis and reduce the hemorrhagic complications. Should have mechanical heart valve with low-pressure gradients. With pivot guard design and leaflet opening and >75 degrees. Cuff design should enhance implantability. Should have minimum taper conduit to facilitate strong coronary anastomosis. Should not have any pleats to allow easier positioning and attachment of the coronary arteries. Wide range of sizes from 19mm- 33mm. Should have both CE and FDA approval. E.g. SJM Masters valved graft, On-X Ascending Aortic Prosthesis, Medtronic Open Pivot Aortic Valved conduit 225 Bileaflet Mechanical Aortic Valve with Valsalva Conduit One piece design collagen coated VALSALVA graft with integrated mechanical aortic bileaflet valve for repair or reconstruction of the ascending aorta and aortic valve. Should mimic the anatomy and blood flow dynamics of the natural sinuses of Valsalva Wide range of sizes from 19mm- 33mm. Should have both CE and FDA approval. Should have the ability to be precisely trimmed and shaped in case of remodeling technique procedures. At least 3 References line at 120O intervals should act as a guide for prosthetic valve. Coated polyester fabric Cross linked Type I bovine collagen Water permeability < 5m * cm -2 min-1 @ 120mmHg 226 Porcine Tissue Heart Valve Mitral / Aortic Should have stented, triple composite design with separate porcine leaflets to optimize leaflets cooptation and reduce stress. Should have anti-calcification treatment to reduce calcification. Low profile height. In aortic position should be available in sizes 19mm-31mm. In mitral position should be available in sizes 25mm to 33mm. Should have both CE and FDA approval. E.g. SJM Epic/ SJM Epic Plus / SJM Epic Max / Medtronic Hancock /SJM Mosaic /SJM Biocor 227 Pericardial Externally Mounted Tissue Heart Valve (Aortic) Should have stented, pericardial single layered leaflet externally mounted to optimize hemodynamics. Should have tissue to tissue interface adding to durability. Should have anti calcification treatment to reduce calcification. Supra annular design. In aortic position should be available in sizes 19mm-29mm. Should have both CE and FDA approval. E.g. Sorin Perceval / Perceval plus 228 Full Aortic Root Bioprosthetic Stentless Valve Sizes: 19 mm, 21mm, 23 mm, 25 mm, 27 mm Should be third generation stentless Native asymmetrical Porcine aortic root, Should have more than 12 years durability and hemodynamic clinical data, Should have AOA tissue treatment to mitigate calcification & Physiological fixation to preserve leaflet function which facilitates open leaflet in systolic position. E.g Medtronic Freestyle 229 Monoleaflet Mechanical Heart Valve Mitral sizes 21-33 mm, Aortic 17-31 mm Should have smooth movement monoleaflet configuration with minimum 70 degrees opening angle. Should be easily implantable and rotatable. Should preferably be premounted on a handle. Sewing ring should be low profile; leaflet and housing should be made of strong , durable alloy. E.g. TTK Chitra 230 Cardioroot Graft one piece-design collagen-coated VALSALVA GRAT. For ascending aorta. Should mimic the anatomy and blood flow dynamics of the natural sinuses of Valsalva. Anatomically correct shape. Unique uncrimped section that does not stretch: can be precisely trimmed and shaped. Water permeability ≤ 5ml • cm-2 • min-1@120 mmHg. Coated polyester fabric Cross-linked Type I bovine collagen. sizes 24,26,28,30,32,34 231 Dacron Membranes, Conduits and Graft 232 ePTFE Conduit length 35 cm, sizes 16, 18, 20, 22 ringed 233 ePTFE Conduit length 35 cm, sizes 16, 18, 20, 22 non ringed 234 ePTFE BT Shunt carbon coated sizes 3.0mm, 3.5mm, 4.0mm, 4.5mm, 5.0mm 235 Knitted Graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability ≤5 mL × cm−2 × min−1@120 mmHg. Wall thickness** 0.49 mm Sizes 40cm length, Dia: 6,7,8,10 mm 236 Knitted Graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability ≤5 mL × cm−2 × min−1@120 mmHg. Wall thickness** 0.49 mm Sizes 40 CM length. Dia:12,14,16,18,20,22,24mm 237 Knitted Graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability ≤5 mL × cm−2 × min−1@120 mmHg. Wall thickness** 0.49 mm Sizes 70 CM length, dia: 6,7,8,10mm 238 Silver Knitted Graft Type I Bovine collagen cross-linked collagen-coated polyester. Graft loaded with an antimicrobial agent: silver acetate Reverse lock-knit knitting technique External velour surface and non-velour inner surface Magnetic Resonance Safe Radially Supported grafts have a polypropylene supportive coil Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Validated intended use with rifampicin loading Water permeability ≤ 5ml/cm-2/min-1@120 mmHg Sizes 40 CMlength, Dia: 6,7,8,10, 239 Silver Knitted Graft Type I Bovine collagen cross-linked collagen-coated polyester Graft loaded with an antimicrobial agent: silver acetate Reverse lock-knit knitting technique External velour surface and non-velour inner surface Magnetic Resonance Safe Radially Supported grafts have a polypropylene supportive coil Validated intended use with rifampicin loading Water permeability ≤ 5ml/cm-2/min-1@120 mmHg Sizes 40 CM length, Dia.12,14,16,18,20,22,24 240 Silver Knitted Graft Type I Bovine collagen cross-linked collagen-coated polyester Graft loaded with an antimicrobial agent: silver acetate Reverse lock-knit knitting technique External velour surface and non-velour inner surface Magnetic Resonance Safe Radially Supported grafts have a polypropylene supportive coil Water permeability: ≤5 mL × cm−2 × min−1/120 mmHg Validated intended use with rifampicin loading Water permeability ≤ 5ml/cm-2/min-1@120 mmHg Sizes 70 CM length, Dia:6, 7, 8, 10 241 Knitted Bifurgated Graft Type I Bovine collagen cross-linked collagen-coated polyester Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Bovine collagen cross-linked type. Water permeability ≤5 mL × cm−2 × min−1@120 mmHg. Wall thickness** 0.49 mm Sizes 12x6, 14x7, 16x8, 18x9mm 242 Silver Knitted Bifurcated Graft Type I Bovine collagen cross-linked collagen-coated polyester Graft loaded with an antimicrobial agent: silver acetate Reverse lock-knit knitting technique External velour surface and non-velour inner surface Magnetic Resonance Safe Radially Supported grafts have a polypropylene supportive coil Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Validated intended use with rifampicin loading Sizes 12x6, 14x7, 16x8, 18x9mm 243 Woven Graft Type I Bovine collagen cross-linked collagen-coated polyester Woven No suture hole bleeding. Bovine collagen cross-linked type. Water permeability ≤5 mL × cm−2 × min−1@120 mmHg. Thickness** 0.38 mm. 15cm usable length, Dia: 12,14,16,18,20,22,24,26,28,30,32mm 244 Silver Woven Graft Type I Bovine collagen cross-linked collagen-coated polyester Graft loaded with an antimicrobial agent: silver acetate Woven External velour surface and non-velour inner surface Magnetic Resonance Safe Radially Supported grafts have a polypropylene supportive coil Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Validated intended use with rifampicin loading Wall thickness: 0.38 mm. Sizes 12,14,16,18,20,22,24,26,28,30,32 245 Woven Aortic Arch Graft Type I Bovine collagen cross-linked collagen-coated polyester Woven No suture hole bleeding. Pre-sewn and Anatomically correct angle of branches designed for total replacement of aortic arch to allow reduced cardiac ischemic time. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.38 mm. 45°suture retention: 2.53 kg. Sizes 20,22,24,26,28,30,32,34 246 Dacron straight woven Grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Sizes 6mm to 16 mm, 30-35 cm long 247 Dacron straight woven Grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Sizes 18mm to 28 mm, 30-35 cm long 248 Dacron straight woven Grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Sizes 30mm to 38 mm, 30-35 cm long. 249 Dacron straight woven Grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Sizes 6mm to 16 mm, 60-70 cm long 250 Dacron straight woven Grafts . Type I Bovine collagen cross-linked collagen-coated polyester Woven Sizes 18mm to 28 mm, 60-70 cm long 251 Dacron straight woven Grafts. Type I Bovine collagen cross-linked collagen-coated polyester Woven Sizes 30mm to 38 mm, 60 cm-70 long 252 Dacron bifurcated woven grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Sizes: 12x6x6 mm, 14x7x7mm, 16x8x8mm, 18x9x9mm, 20x10x10mm with 40-50cm length. 253 Knitted Dacron straight graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability ≤5 mL × cm−2 × min−1@120 mmHg. Wall thickness: 0.49 mm Sizes: 6mm to 16 mm with 30-35 cm length. 254 Knitted Dacron straight graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability ≤5 mL × cm−2 × min−1@120 mmHg. Wall thickness: 0.49 mm Sizes: 18mm to 24 mm with 30-35 cm length. 255 Knitted Dacron straight graft coated. Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability ≤5 mL × cm−2 × min−1@120 mmHg. Wall thickness: 0.49 mm Sizes: 6mm to 16 mm with 60-70 cm length 256 Knitted Dacron straight graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability ≤5 mL × cm−2 × min−1@120 mmHg. Wall thickness: 0.49 mm Sizes: 18mm to 24 mm with 60-70 cm length 257 Dacron bifurcated knitted grafts Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability ≤5 mL × cm−2 × min−1@120 mmHg. Wall thickness: 0.49 mm Sizes: 12x6x6 mm, 14x7x7mm, 16x8x 8mm,. 18x9x9mm with 40-50 Cm length. 258 Dacron Woven 3 branch arch grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven 30cm usable length, 12-8-8mm and 14-10-10mm branch sizes 259 Dacron Woven 4 branch arch grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven 50cm usable length, 24-30mm dia, with 12,10,8,8mm branch grafts 260 Dacron Woven Thoraco- abdominal grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven 47cm usable length 20-32mm dia. with 10-10-8-8mm side branch grafts 261 Dacron Woven graft with perfusion side branch Type I Bovine collagen cross-linked collagen-coated polyester Woven 50cm usable length with dia. 20-34mm with 10 mm perfusion side branch 262 Dacron Woven extra length graft with offset branch graft Type I Bovine collagen cross-linked collagen-coated polyester Woven 50cm usable length with dia. 20-34 mm with 10mm perfusion side branch 263 Dacron Woven pre-curved graft Type I Bovine collagen cross-linked collagen-coated polyester Woven 50cm usable length with dia. 22-32 mm with 8mm perfusion side branch. 264 Woven Trifurcated graft Coated polyester fabric Cross-linked Type I bovine collagen Construction Knitted, reverse locknit Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.49 mm Burst strength: 32.7 kg/cm2 45°suture retention: 3.37 kg Sizes: 12mm X 6mm X 7mm, 14 mm X7mm X 7mm, 16mm X 8mm X 7mm, 40-50 cm in length 265 Dacron Knitted axillo-bifemoral bifurcated graft with radial support Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Size 100cm usable length with 60cm side branch usable length sizes: 8x8mm Right, 8x8mm Left, 10x10mm Right, 10x10mm Left 266 Dacron Knitted Axillo-bifemoral graft with radial support Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Angle 90 degrees angle with 60 cm usable length side branch 8mm and 10 with supported lengths 20-45cm 267 Dacron Knitted Femoral-Femoral grafts Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable sizes 6mm and 8 mm 30cm and 40 cm long 268 Dacron Knitted straight Peel able support Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable lengths 6mm, 8mm and 10 mm 269 Dacron straight woven Grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Usable lengths of 6mm to 16 mm, 30-35 cm long. 270 Dacron straight woven Grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Usable lengths of 18mm to 28 mm, 30-35 cm long, Gelatin coated. 271 Dacron straight woven Grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Usable lengths of 30mm to 38 mm, 30-35 cm long. 272 Dacron straight woven Grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Usable lengths of 6mm to 16 mm, 60-70 cm long 273 Dacron straight woven Grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Usable lengths of 18mm to 28 mm, 60-70 cm long. 274 Dacron straight woven Grafts Type I Bovine collagen cross-linked collagen-coated polyester Woven Usable lengths of 30mm to 38 mm, 60 cm-70 long. 275 Knitted Dacron straight graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable sizes of 6mm to 16 mm with 30-35 cm length. 276 Knitted Dacron straight graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable sizes of 18mm to 24 mm with 30-35 cm length. 277 Knitted Dacron straight graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable sizes of 6mm to 16 mm with 60-70 cm length. 278 Knitted Dacron straight graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable sizes of 18mm to 24 mm with 60-70 cm length, Gelatin coated. 279 Dacron bifurcated knitted grafts Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable sizes of 12mmX6 mm, 14mm X 7mm, 16mmX 8mm,.18mm X 9mm with 40-50 cms length. 280 Dacron Woven 3 branch arch grafts Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable sizes of 20mm to 34 mm. 281 Dacron Woven 4 branch arch grafts Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable sizes of 20mm to 34 mm. 282 Dacron Woven Thoracoabdominal grafts Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable sizes of 20mm to 30mm. 283 Dacron Woven graft Type I Bovine collagen cross-linked collagen-coated polyester Woven Usable sizes of 20 to 34mm with 8mm and 10 mm perfusion side branch, 40-50 cm length. 284 Dacron Woven extra length graft with offset branch graft Type I Bovine collagen cross-linked collagen-coated polyester Woven Usable lengths of 22 to 32 mm with 8mm perfusion side branch. 285 Dacron Woven pre-curved graft Type I Bovine collagen cross-linked collagen-coated polyester Woven Usable lengths of 22 mm to 32 mm with 8mm perfusion side branch. 286 Woven Trifurcate graft Type I Bovine collagen cross-linked collagen-coated polyester Woven Usable lengths of 12mm X 6mm X 7mm, 14 mm X7mm X 7mm, 16mm X 8mm X 7mm, 40-50 cm in length. 287 Dacron Knitted axillo-bifemoral bifurcated graft with extended support, Gelatin coated. Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg 288 Dacron Knitted Axillo-bifemoral graft Type I Bovine collagen cross-linked collagen-coated polyester. Reverse locknit knitting technique for radial tensile strength. No suture hole bleeding. Water permeability: ≤5 mL × cm−2 × min−1@120 mmHg Wall thickness: 0.35 mm Burst strength: 35.3 kg/cm2 45°suture retention: 1.83 kg Usable sizes of 90 degrees angle with 60 cm side branch 8mm and 10 mm, Gelatin coated 289 Dacron Marking Patch (Filamentous Fabric) Should be Nominal Thickness; around 0.6 mm Water permeability; approximately 1800ml Popularly known as ”MARKING PATCH” Markings arrow should indicate, in which direction the patch is to be stitched. Sizes 2” x 2”, 4 x4” and 6x6 ‘ inches 290 Double Velour Fabric Should have Nominal Thickness; 1.4-1.6mm. With Water permeability of approximately 3800 ml. Should have No Reference markings. Used for Repair of Intracardiac defects and for VSD repair in Adults. SIZES: - 4”X4” & 6”X6” 291 Ascending aortic reconstruction Valsalva graft One piece design collagen coated VALSALVA graft for repair or reconstruction of the ascending aorta. Should mimic the anatomy and blood flow dynamics of the natural sinuses of Valsalva Unique un-crimped section that does not stretch should allow easy sewing of valve remnants or prosthetic valve Should facilitate estimation of the length required for optimal placement of valve remnants or prosthetic valve to ensure optimal clinical outcomes. Should have the ability to be precisely trimmed and shaped in case of remodeling technique procedures. At least 3 References line at 120O intervals should act as a guide for prosthetic valve. Coated polyester fabric Cross linked Type I bovine collagen Water permeability < 5m * cm -2 min-1 @ 120mmHg 292 Dacron Graft Straight Tube dilatation resistant ,gelatin sealed , Koper knitted polyester vascular graft 40 cm 6,7,8,10,12 293 Dacron Graft Straight Tube dilatation resistant ,gelatin sealed , Koper knitted polyester vascular graft 70 cm 6,7,8,10,12 294 Dacron Graft Silver coated Straight tube 40 CM 6,,7,,8 295 PTFE Membranes and Graft 296 Outflow Tract Fabric PTFE. Should have Nominal Thickness: around 0.9mm. with Water Permeability: 250ml. Used for Aortic repair, Pulmonary Outflow tracks patching & other Intracardiac Defects. SIZES: - 4X4 & 6”X6” 297 Thin Wall Patch of PTFE Should have multidirectional node fiber structure, to accommodate cellular in growth & give uniform strength throughout the patch Surface. Should be soft & pliable for easy surgical positioning. No Pre clotting should be required. Should have excellent biocompatibility for cardiac& vascular repairs and peripheral vascular reconstruction. Should have Thickness around 0.4mm suitable for Aortic & Vascular repair SIZES:- 1CMX9CM,2X9CM & 3CMX6CM (OVAL SHAPED) 298 Regular Wall Patch of PTFE Should have multidirectional node fiber structure to accommodate cellular in-growth. • Should be soft & pliable for easy surgical positioning. • No Pre clotting should be required. • Should have excellent biocompatibility for cardiac& vascular repairs and peripheral vascular reconstruction. • Thickness – 0.6mm • SIZES:- 3CMX 3CM,5CMX7.5CM,2.5CMX15CM & 10CM X 15CM (RECTANGULAR) 299 Low Porosity Felts of PTFE Should have Thickness 1.5 to 1.8mm. Should have Low Porosity to control bleeding and for buttress for sutures. SIZES:-2 X 2, 4”X4’ & 6”X6’ 300 PTFE Normal felt; Should have Thickness 1.5 to 1.8mm. To be used as a buttress for sutures and Friable tissue SIZES:- 2”x2 ,4”x4 & 6”x6 301 PTFE Hard (Thick) FELTS Should have Thickness around 3 mm to provide added support to tissue. SIZES:- 4”X4” & 6”X6 302 PTFE Felts Pledgets Shape:-Rectangle, Square Oval &Round. Should have Thickness around 1.6mm Sizes:- 4.8mm x 6.0mm (Rectangle), 9.5mmx4.8mm (Rectangle), 6.0x6.0mm (Square) & 4.8mm x 6.0mm (Oval) 303 Regular & Thin wall e-PTFE graft All length and diameters (2-10mm) 304 Ring reinforced PTFE graft All lengths and diameters (4-30mm) 305 BT Shunt PTFE graft with carbon lining All length and diameters (2-5mm) 306 Large Diameters e PTFE Grafts all sizes and length Sizes of all length and diameters (18-36mm) 307 e-PTFE Stretch Large Diameter Reinforced Aortic Vascular Graft Sizes of all length and diameters (18-36mm) 308 e-PTFE Cardiovascular Patch Sizes:- 5cm x 15cm x 0.6mm x10cm x 15cm x 0.6mm, 3cmx 6cm x 0.4mm 309 e-PTFE Pericardial Membrane 0.1mm thick Sizes:- 5cm x 15cm x 0.6mm x10cm x 15cm x 0.6mm, 3cmx 6cm x 0.4mm 310 e-PTFE Pericardial Membrane 0.1mm thick Size 6cm x 12cm/12cmx12cm/15cm x 20cm 311 e-PTFE Stretch Reinforced Thin Wall Heparin Bonded Vascular Graft 10cms length Size: 3mm/3.5mm/4mm/5mm/6mm diameter 312 e PTFE Stretch Reinforced Thin wall Non Ringed Heparin Bonded Vascular Graft 40/80cms length Size: 6/7/8/mm diameter 313 e- PTFE Stretch Reinforced Removable Ringed Thin Wall Heparin Bonded Vascular Graft 50/70/80cm length size: 6/7/8mm diameter 314 e-PTFE Stretch Reinforced Thin Wall limbed Bifurcated Vascular Graft Size :12/6x50cm, 14/7x40cm/50cm; 16/8x50cm; 18/9x50cm; 20/10x50cm; 22/12 x40cm; 24/12x40cm 315 e PTFE Suture Size CVO/CV2/CV3/CV4/CV5/CV6/CV7/CV8 316 e-PTFE Stretch re-in forced removable ringed thin wall pre configured axillo bi femoral vascular graft. Size: i) 8mm diameter x 70cm/40cm length ii) 8mm diameter x 90cm/40cm length 317 e PTFE stretch re- in forced low profile integrated radially supported thin wall vascular graft Size 6mm/7mm/8mm diameter 40cm/60cm/80cm length 318 e PTFE stretch re-in forced removable ringed thin wall vascular graft Size: 6mm/8mm diameter x 50cm/70cm/80cm length 319 Pericardial Patch Cardiac and great-vessel reconstruction and repair and pericardial closure. soft, pliable tissue conforms to uneven surfaces and minimizes suture hole leaks for more reliable repairs. Glutaraldehyde and EnCap™ anti-calcification technology,promote host endothelialization . bovine pericardium resists shrinkage and aneurysm formation. Rinse less Preparation, Ready to use. Thinner patch 320 Bovine Pericardial Patch Ready-to-use, rinseless preparation, glutaraldehyde fixed/ glutaraldehyde free, anticalcification treatment, size 8x8 cm, preferably USFDA approved 321 Vacuum Drainage Sets, Thoracic Drains and Tubes 322 Thoracic Catheter All Sizes: Extra soft thoracic drainage catheter, made of DEHP free medical grade polymer, gentle to body tissues & most suitable for thoracic drainage. Catheters are marked at every 2cm from the last eye. Sterile, double (straight) packed in peel able pouch pack. Sizes required: Sizes: 16, 20, 24, 28, 32, 36, 40 FG 323 Thoracic Catheter Right Angled (90o) All Sizes: Extra soft angled thoracic drainage catheter, made of DEHP free medical grade polymer, gentle to body tissues & most suitable for thoracic drainage. Catheters are marked at every 2cm from the last eye. Sterile, double packed in peelable pouch pack. Sizes: 16, 20, 24, 28, 32, 36, 40 FG 324 Thoracic Catheter with trocar – All Sizes Thoracic drainage catheter with trocar for thoracic drainage purpose. Catheters to be marked at every 5, 10, 15 & 20 cm from the last eye. Fitted with tapered connector. Sterile, packed in peelable pouch pack. Sizes: 12, 16, 20, 24, 28, 32, 36 FG 325 Chest Drainage Bottle – 2000 ml Under water seal drainage system. Double chamber compact unit with 2000 ml capacity. Easy to read graduation on bottle to determine the drainage volume precisely. Clearly marked initial level to ensure the underwater seal. Separate suction port for connection with suction unit. Should have valve to prevent excess suction. Kink resistant large bore tubing to facilitate unrestricted flow. Unit to be provided with metal hangers and floor stand. Sterile, packed in peelable pouch pack. 326 Chest Drainage Bottle – 1200 ml: Under water seal drainage system. Single chamber compact unit with 1200 ml capacity. Easy to read graduation on bottle to determine the drainage volume precisely. Should have valve to prevent excess suction. Clearly marked initial level to ensure the underwater seal. Specially designed positive pressure relief valve. Separate suction port for connection with suction unit. Kink resistant large bore tubing to facilitate unrestricted flow. Unit to be provided with metal hanger/ floor stand. Sterile, packed in peelable pouch pack 327 Chest Drainage Bottle – 500 ml Under water seal drainage system. Single chamber compact unit with 500 ml capacity. Easy to read graduation on bottle to determine the drainage volume precisely. Clearly marked initial level to ensure the underwater seal. Separate suction port for connection with suction unit. Kink resistant large bore tubing to facilitate unrestricted flow. Should have valve to prevent excess suction. Unit to be provided with metal hanger/ floor stand. Sterile, packed in peelable pouch pack 328 Vacuum Drainage Sets Device for close wound drainage under negative pressure post operatively with option to use one or two catheters. Drain catheters should be provided with radio opaque line and smooth eyes. Connecting tube should be kink resistant and should be provided with additional strength to withstand the suction. Chamber should be easy to depress so as to activate the suction of bellow unit. Should be available with different catheter. Should be sterile and individually packed. Sizes of 8, 10, 12, 14, 16, 18 FG. 329 Embolecomy Catheters 330 Fogarty Arterial Emblectomy Catheter Vinyl Latex Balloon tipped catheter for Arterial Emblectomy procedure. Usable length 60-80 cm, Size 2F to 8F. Recessed winding technique for balloon attachment for maintaining balloon symmetry for uniform contact with vessel wall, providing consistent clot removal 331 Thru Lumen Fogarty Catheter Vinyl Latex Balloon tipped catheter for Arterial Embolectomy procedure. Usable length 80 cm. Size 2F-8F. Second lumen for guide wire compatibility facilitating crossing occluded, tortuous &stenotic arterial wall OR to be used for drug delivery & blood sampling. Stainless steel bushes under proximal & distal balloon windings for visualization under fluoroscopy. Recessed winding technique for balloon attachment for maintaining balloon symmetry for uniform contact with vessel wall, providing consistent clot removal 332 Cautery Accessories 333 Electro Cautery Return Plate with Cord All sizes should be available Disposable Sticky patient return split monitoring style. Pre attached cable (US FDA approved) 334 Electro Cautery Return Plate without Cord All sizes should be available Disp. Sticky patient return split monitoring style. Cord should be provided separately. US FDA approved 335 Cautrey Lead Disposable.• Hand control 2 button switch• Should be light weight• US FDA approved• Should be compatible with all standard brands of cautery machines. Smoke evacuation attachment compatible PTFE coated lead tip for easy cleaning of eschar Cautery tip cleaner should be supplied along with it. 336 Ligating Clips, Bull Dog Clamps and Aortic Punches 337 Titanium Ligating Clips “Size – Small” Wire of the clip should be ‘ Heart shaped for a firm grip on Vessels Clips should be of ‘Chevron’ shape for better closure Cartridge should have adhesive backing for better control while loading. Clips should be easy to lad with soft loading technique. Clip cartridges should be color coded for better identification. Clips quoted should be registered in India for selling. Should have all required documentations like from 10 A and Form 41 etc. Should be US FDA approved with clinic data backing for the same Reference size Liga clip LT 100 338 TITANIUM LIGATING CLIP “ SIZE MEDIUM Wire of the clip should be ‘Heart shaped’ for a firm grip on vessels Clips should be of ‘Chevron’ shape for better closure. Cartridge should have adhesive backing for better control while loading. Clips should be easy to load with soft loading technique. Clip cartridges should be color coded for better identification. Clips quoted should be registered in India for selling. Should have all required documentations like from 10A and form 41 etc. Should be US FDA approved with clinic data backing for the same Reference size Liga clip LT 200 339 Titanium Ligating Clips”Size- Medium Large” Wire of the clip should be ‘Heart shaped’ for a firm grip on vessels. Clips should be of “Chevron’ shape for better closure. Cartridge should have adhesive backing for better control while loading. Clips should be easy to load with soft loading technique. Clip cartridges should be color-coded for better identification. Clips quoted should be registered in India for selling. Should have all required documentation like form 10A and form 41 etc. Should be US FDA approved with clinic data backing for the same Reference size Liga clip LT 300 340 Titanium Ligating Clips” Size- Large Wire of the clip should be ‘Heart shaped for a firm grip on Vessels. Clips should be of ‘Chevron’ Shape for better closure Cartridge should have adhesive backing for better control while loading. Clips should be easy to load with soft loading technique. Clip cartridges should be color-coded for better identification. Clip quoted should be registered in India for selling. Should have all required documentation like from 10A and form 41 etc. Should be US FDA approved with clinic data backing for the same. Reference size Liga clip LT 400 341 Open Applicator For Titanium Clips (Small, Medium, Medium-Large, Large) Should be available in three shapes :CURVED, ANGLED & RIGHT ANGLED Device to be compatible for titanium clips listed in the list above 342 Bulldog Clamp Novaclip atraumatic spring clip,17mm straight,Blue 343 Bulldog Clamp Novaclip atraumatic spring clip,12mm straight,Magenta 344 Bulldog Clamp Novaclip atraumatic spring clip, 12mm angled, Yellow 345 Bulldog Clamp Greyhound Adjustable spring clip, 6mm straight 346 Applier Applicator for Sofia / Greyhound® Spring Clips 347 Applier Applicator for NOVACLIP® spring clips 348 Enclose II Proximal Anastomosis Assist Device (with Aortic Punch 3.5 mm) 349 Enclose II Proximal Anastomosis Assist Device (with Aortic Punch 4.0 mm) 350 Enclose II Proximal Anastomosis Assist Device (with Aortic Punch 4.5 mm) 351 Aortic punch Long handle Should have sharp dual cutting edge for clean, precise removal of aortic tissue. A conical tip should be there for easy insertion by straight or button hole technique. Ten blade sizes for trimming to desired size and shape 2.5mm – 6.0mm 352 Carotid Shunts Should have A Wide selection for Carotid Endarterectomy procedures. SHUNTS should be available in various sizes and lengths, including Straight, Tapered, “T”, “H” Design to add versatility in use. 353 Bull Dog Clamps All Sizes Disposable’ bull dog’ clamps for temporary occlusion of vascular structures. Atraumatic. Made with standard quality plastic. Should be ETO sterlisable for repeated use. 354 Plastic Bulldog All sizes, Curved or straight, one piece design 355 Vessel Scraper Should be able to scape fat away from the coronary artery. Should be light weight. Should be pre mounted on a disposable handle 356 Arteriotomy Knife Should have high quality, sharp pointed blade for precise incision. Should be suitable to make incision in 1mm artery. Should be pre mounted on a disposable handle. 357 Titanium clip Metal ligation clip 1.91 mm width and 2.24 closed length with 30% smaller than small clips, USFD and CE approved, heart shaped wire with inner locking grooves f chevron shape for more vessel engulfing, Transverse Grooves, Micro white Cartidge of 6 Clip 358 Titanium clip Metal ligation clip with 1.98 mm width and 3.63 closed length, USFD and CE approved, heart shaped wire with inner locking grooves , chevron shape for more vessel engulfing, Transverse Grooves, Lateral, Clip-restraining springs, small yellow Cartridge of 24 Clip 359 Titanium clip Metal ligation clip with 2.08 mm width and 3.63 closed length, USFD and CE approved, heart shaped wire with inner locking grooves , chevron shape for more vessel engulfing, Transverse Grooves, Lateral, Clip-restraining springs, small wide Red Cartridge of 24 Clip 360 Titanium clip Metal ligation clip with 3.02 mm width and 5.89 closed length, USFD and CE approved, heart shaped wire with inner locking grooves , chevron shape for more vessel engulfing, Transverse Grooves, Lateral Clip-restraining springs, medium blue Cartridge of 24 Clip 361 Applier High quality stainless steel applier, compatible only with Weck Horizon clips, opens at box lock for cleaning purpose, jaws alignment to avoid clip fallout Angle shape and Straight shape 362 Surgical Brush with Iodine Povidone and Chlorohexidine Should be sponge impregnated 12% povidone-iodine in a 15ml solution of Teepol, P.E.G and water supplied with nail cleaner. Should be sponge impregnated 20% chlorohexidine-iodine in a 15ml solution of ISO PROPYL Alcohol and water supplied with nail cleaner. Should be US FDA APPROVED 363 Respiratory muscle exerciser (Inspiratory muscle trainer device) Should incorporate a flow-independent, one-way valve to ensure consistent resistance, Should feature an adjustable specific pressure setting to be set at a particular time. It should work via inhalation to exercise the respiratory muscles. It should have flow independent one-way valve, which should work at constant pressure regardless of patients airflow. It should be easy to set at adjustable pressure, which can be used/held in any position. It should be easy to clean & should have the capacity to be used with mouthpiece. It should be individually packed in poly bag. 364 Reusable Gel Pack Reusable Gel packs for pain management. It should be able to be kept in freezer for cold therapy. It should be able to be microwaved (for appx. 2mintues) / kept in boiling water to provide hot fomentation. Gel packs must be of a superior quality and non-toxic filling should be safe and hold temperatures for longer duration. Should be durable, burst & puncture resistant. Should have been designed to ensure even spread of gel inside the pack. Two sizes: Large: 15 x 30cm (6” x 12”) & Medium: 10 X 25 cm (4” x10”). 365 Sternal band for sternal closure Polyethero-ether ketone material pack of 5 366 Central Venous Catheters 367 Quintuple Lumen Central Venous Catheter Set- Adult Base material of catheter should be polyurethane. The surface of the catheter should be modified with non-leaching technology with polymer surface modification, on both outer surface and internal luminal surface with Antimicrobial Effect Durable over 30 Days It should have Five (5) lumen Central Venous catheter with Straight Introducer Needle, Syringe, Dilator, Infusion valve and Scalpel should be available in the kit. It should have Nitonol Guide wire one soft J tip and one soft straight tip, printed with length markings and ECG mark Size: 12 Fr, No. of lumens: 5, Length: 15cm, Lumen dia (gauge): 16/18/18/18/12, Flow (ml/min): 55/28/28/28/185 Introducer needle: V type 18G, Guidewire length 50cm, 0.89mm dia. 368 Quadruple Lumen Central Venous Catheter Set- Adult Base material of catheter should be polyurethane. The surface of the catheter should be modified with non-leaching technology with polymer surface modification, on both outer surface and internal luminal surface with Antimicrobial Effect Durable over 30 Days It should have Four (4) lumen Central Venous catheter with Straight Introducer Needle, Syringe, Dilator, Infusion valve and Scalpel should be available in the kit. It should have Nitonol Guide wire one soft J tip and one soft straight tip, printed with length markings and ECG mark Size: 8 Fr, No. of lumens: 4, Length: 15cm, Lumen dia (gauge): 14/18/18/16, Flow (ml/min): 50/20/20/50 Introducer needle: V type 18G, Guidewire length 50cm, 0.89mm dia. 369 Tripe lumen Central Venous catheter Set- Adult Base material of catheter should be polyurethane. The surface of the catheter should be modified with non-leaching technology with polymer surface modification, on both outer surface and internal luminal surface with Antimicrobial Effect Durable over 30 Days It should have Three (3) lumen Central Venous catheter with Straight Introducer Needle, Syringe, Dilator, Infusion valve and Scalpel should be available in the kit. It should have Nitonol Guide wire one soft J tip and one soft straight tip, printed with length markings and ECG mark Size: 7 Fr, No. of lumens: 3, Length: 15cm, Lumen dia (gauge): 16/18/18, Flow (ml/min): 50/28/28, Introducer needle: V type 18G, Guidewire length 50cm, 0.89mm dia. 370 Tripe lumen Central Venous catheter Set- Pediatric Base material of catheter should be polyurethane. The surface of the catheter should be modified with non-leaching technology with polymer surface modification, on both outer surface and internal luminal surface with Antimicrobial Effect Durable over 30 Days It should have Three (3) lumen Central Venous catheter with Straight Introducer Needle, Syringe, Dilator, Infusion valve and Scalpel should be available in the kit. It should have Nitonol Guide wire one soft J tip and one soft straight tip, printed with length markings and ECG mark Size: 5 Fr, No. of lumens: 3, Length: 13cm, Lumen dia (gauge): 20/22/22, Flow (ml/min): 30/15/15, Introducer needle: S type 21G, Guidewire length 50cm, 0.46mm dia. 371 Kt for Rotaflow ECMO Machine 372 ECMO PLS Kit Adult Centrifugal Pump. Max flows: 0 to 10 lits/min. Channel type. Priming volume: 20 - 32 ml. Max Flows: 0.5 to 7 lits/min. Surface area: 1.8 sq. mts. Diffusion membrane Oxygenator. Hollow fiber polymethylpentene. Heat exchanger: Integrated into oxygenator. Heat exchanger membrane type: Polyurethane. Coated with Bioline (Albumin + Heparin) 373 ECMO PLS Kit Adult MECC Centrifugal Pump. Max flows: 0 to 10 lits/min. Channel type. Priming volume: 20 - 32 ml. Max Flows: 0.5 to 7 lits/min. Surface area: 1.8 sq. mts. Diffusion membrane Oxygenator. Hollow fiber polymethylpentene. Heat exchanger: Integrated into oxygenator. Heat exchanger membrane type: Polyurethane. Coated with Bioline (Albumin + Heparin) Modified to incorporate extra oxygenator , centrifugal pump and ECCO2 374 ECMO PLS Custom Pack Adult Anti thrombotic Tubing for ECMO machine Coated with Bioline (Albumin +Heparin) 375 ECMO cannulas Venous Bioline coated Sizes 19, 21, 23, 25, 29 376 ECMO cannulas Arterial Bioline coated Sizes 13, 15, 17, 19, 21 377 PiCCO Catheter PiCCO technology is based on two principles namely, trans pulmonary thermodilution and pulse Global End Diastolic Function contour analysis. Stroke Volume Variation(SVV).Pulse Pressure Variation(PPV),Global Ejection Fraction(GEF),Extravascular Lung water index (ELWI)Pulmonary Vascular Permiability Index (PVPI). Systemic Vascular Resistance index(SVRI)Temperature sensor at the catheter tip for trans pulmonary thermodilution 378 Dressing Kit 379 Advance IV Kit for positive patient. Peripheral IV line kit consisting of 1 pc of reinforced IV dressing advance size 7cm x 8.5cm, 1 pc of 2% w/v Chlorhexidine gluconate and 70% v/v isopropyl alcohol skin prep swab, 1 pc of Latex free disposable tourniquet and 1 pc of sterile gauze swab / 1 ml Sting Barrier Film. 20 Pcs in Pkt. It should be comfortable for positive patient. 380 Dressing All Sizes Polyurethane film with acrylic adhesive dressings. Adhesive, surgical site dressing.• Sterile.• Individually packed.Should be waterproof, sterile barrier to external contaminants including liquids, bacteria and viruses. Complies with ISO-10993 standards for biocompatibility. Should be HRIPT and HCIPT Test compliant. High moisture vapour transmission rate MVTR 2760 g/m2/24hrs 381 CVC dressing Neonates. Polyurethane film peripheral IV dressing with acrylic adhesive oval shaped with deep notch and tails reinforced. 3 extra sterile tape strips to additionally secure the dressing. Should be waterproof, sterile barrier to external contaminants including liquids, bacteria and viruses. Complies with ISO-10993 standards for biocompatibility. Should be HRIPT and HCIPT Test compliant. High moisture vapour transmission rate MVTR 2760 g/m2/24hrs. Size: 3.8cm x 4.5cm. 382 CVC dressing Pediatric. Polyurethane film peripheral IV dressing with acrylic adhesive oval shaped with deep notch and tails reinforced. 3 extra sterile tape strips to additionally secure the dressing. Should be waterproof, sterile barrier to external contaminants including liquids, bacteria and viruses. Complies with ISO-10993 standards for biocompatibility. Should be HRIPT and HCIPT Test compliant. High moisture vapour transmission rate MVTR 2760 g/m2/24hrs. Size: 5cm x 5.7cm. 383 CVC Dressing Adult Polyurethane film peripheral IV dressing with acrylic adhesive oval shaped with deep notch and tails reinforced. 3 extra sterile tape strips to additionally secure the dressing. Should be waterproof, sterile barrier to external contaminants including liquids, bacteria and viruses. Complies with ISO-10993 standards for biocompatibility. Should be HRIPT and HCIPT Test compliant. High moisture vapour transmission rate MVTR 2760 g/m2/24hrs. Size: 8.5cm x 10.5cm. 384 Transparent Film Dressing Frame Dressings are made with a thin, semi-permeable film that enables long wear time and full site visibility to minimize unnecessary dressing changes. High moisture-vapour transmission rate (MVTR) for breathability andadhesion throughout the surgery. Size 4 inch x 10 inch (10 cm x 25 cm) 385 Iodophor Impregnated Incise Drape Adult Adhesive with Iodophor coated incise drape It Should be USFDA approved. It Should be effective against methicillin-resistant Staphylococcus aureus (MRSA) at a depth of 1000 microns. Class III medical device. Should comply to NICE guidelines on the use of incise drapes in CTVS Surgery. High moisture-vapour transmission rate (MVTR) for breathability andadhesion throughout the surgery. Size 60x45cm 386 Iodophor Impregnated Incise Drape Small Adult Adhesive with Iodophor coated incise drape It Should be USFDA approved. It Should be effective against methicillin-resistant Staphylococcus aureus (MRSA) at a depth of 1000 microns. Class III medical device. Should comply to NICE guidelines on the use of incise drapes in CTVS Surgery. High moisture-vapour transmission rate (MVTR) for breathability andadhesion throughout the surgery. Size 56x45cm 387 Iodophor Impregnated Antimicrobial Incise Drape Pediatric Adhesive with Iodophor coated incise drape It Should be USFDA approved. It Should be effective against methicillin-resistant Staphylococcus aureus (MRSA) at a depth of 1000 microns. Class III medical device. Should comply to NICE guidelines on the use of incise drapes in CTVS Surgery. High moisture-vapour transmission rate (MVTR) for breathability andadhesion throughout the surgery. Size 34x55cm 388 Canister 500 ML 500 ml Canister with Gel Company Should be having manufacturing or import License It should be DCGI and FDA & CE Certified Should be compatible to burst abdominal vac dressing veraflow and Abthera 389 Vac Dressing Granufoam NPWT Dressing kits containing Small Polyurethane foam Dressing (10 x 7.5 x 3.2cm) with drape, ruler, trac tubing and 1-ltr canister for exudate collection.It should be DCGI and FDA & CE Certified & company having manufactutring or import license 390 Vac Dressing Granufoam NPWT Dressing kits containing Medium Polyurethane foam Dressing (18 x 12.5 x 3.2cm) with with drape, ruler, trac tubing and 1-ltr canister for exudate collection.It should be DCGI and FDA & CE Certified & company having manufactutring or import license 391 Vac Dressing Granufoam NPWT Dressing kits containing Large Polyurethane foam Dressing (26 cm x 15 cm x 3.2cm) with drape, ruler, trac tubing and 1-ltr canister for exudate collection.It should be DCGI and FDA & CE Certified & company having manufactutring or import license 392 Pressure Garment Custom made Pressure Garment below Knee stockings Pair. 393 Pressure Garment Custom made Pressure Garment Full Knee stockings Pair. 394 Pressure Garment Custom made Pressure Garment Fore arm 395 Pressure Garment Custom made Pressure Garment Full arm 396 Pressure Garment Custom made Pressure Garment Fore arm with Guantlet 397 Pressure Garment Custom made Pressure Garment Full arm with guantlet 398 Aortic Neocuspidization Kits 399 Aortic Valve Neocuspidisation Sizer Multiuse System Sizer Number 21, 23, 25, 27, 29, 31, 33, 35 (1 each- 9 total) Plates for fixation and trimming- One Petri Dish- One 0.6% Glutaraldehyde Soaking Tray- One Sterilization Container- one 400 Aortic Valve Neocuspidisation Pediatric Sizer Multi use System Sizer No. 13, 15, 17 (One each- 3 total) 401 Aortic Valve Neocuspidisation Sterile Templet Single-Use, individually packaged ( Pack of 10) 402 Aortic Valve Neocuspidisation Sizer Common Kit Disposable, Sizers 19, 21,23, 25, 27, 29 (Total 6 sizes) Templates for molding leaflets (one Each) Pericardium Fixation Plates (one) Petri Dish- One 0.6% Glutaraldehyde Solution Tray- One Leaflet Size Mark Sheet (One) 403 Aortic Valve Neocuspidisation Sizer Disposable Kit AVNeo Small Sizer 13, 15, 17 (3 sizes) One each 404 Aortic Valve Neocuspidisation Sizer Disposable Kit AVNeo Large Sizer 31, 33, 35 (3 sizes) one each 405 Gauze Pieces 406 Gauze Pieces with American Folding Sterile, Cotton Gauze swab with pack of 5 swab, 12 Ply, Folded in such a way that no loose thread should be found, Bleached with Hydrogen Peroxide. Radio-opaque Thread must be woven in the Gauze piece Size 7.5x7.5 cm 407 Gauze Pieces with American Folding Sterile, Cotton Gauze swab with pack of 5 swab, 12 Ply, Folded in such a way that no loose thread should be found, Bleached with Hydrogen Peroxide. Radio-opaque Thread must be woven in the Gauze piece Size 10x10 cm 408 Gauze Pieces with American Folding Sterile, Cotton Gauze swab with pack of 5 swab, 12 Ply, Folded in such a way that no loose thread should be found, Bleached with Hydrogen Peroxide. Radio-opaque Thread must be woven in the Gauze piece Size5x5 cm 409 Surgical Sealants and Glues 410 Fibrin glue with synthetic aprotinin 4ml 411 Bovine Gelatin Matrix with thrombin 5000IU in 10ml 412 Bovine Gelatin Matrix with thrombin 2500IU in 5ml 413 Bovine Collagen matrix with PEG coating Sizes: 27x27mm 414 Bovine Collagen matrix with PEG coating Sizes: 45x45mm 415 Bovine Collagen matrix with PEG coating Sizes: 45x90mm 416 Absorbable adhesion barrier composed of CMC and Sodium hyaluronate Sizes: 13x7.5cm 417 Absorbable adhesion barrier composed of CMC and Sodium hyaluronate Sizes: 13x15cm 418 Surgical Adhesive GLUE BSA ( Bovine Serum Albumin ) & glutaraldehyde in the ratio of 4:1 surgical glue • Thrombin Free • Biodegradable and Biocompatible • Simple, ergonomic design allows for unmatched preparation and ease of use. • No reconstitution or manual mixing needed. • Room temperature storage - No warming/thawing needed. • Open and use operability • Should reach full strength in just two minutes •Should seal, adhere, or reinforce soft tissue in adults. It should be able to be used along with the usual surgical ways to seal tissues, which can include sutures, staples, and/or patches. It should be used for soft tissues of the cardiac, vascular and lung Should seal anastomoses, reinforces friable tissue, and adheres dissected tissues together used for sealing, adhering and reinforcing tissue 2ml 419 Surgical Adhesive GLUE BSA ( Bovine Serum Albumin ) & glutaraldehyde in the ratio of 4:1 surgical glue • Thrombin Free • Biodegradable and Biocompatible • Simple, ergonomic design allows for unmatched preparation and ease of use. • No reconstitution or manual mixing needed. • Room temperature storage - No warming/thawing needed. • Open and use operability • Should reach full strength in just two minutes •Should seal, adhere, or reinforce soft tissue in adults. It should be able to be used along with the usual surgical ways to seal tissues, which can include sutures, staples, and/or patches. It should be used for soft tissues of the cardiac, vascular and lung Should seal anastomoses, reinforces friable tissue, and adheres dissected tissues together used for sealing, adhering and reinforcing tissue nm5ml 420 Surgical Adhesive GLUE BSA ( Bovine Serum Albumin ) & glutaraldehyde in the ratio of 4:1 surgical glue • Thrombin Free • Biodegradable and Biocompatible • Simple, ergonomic design allows for unmatched preparation and ease of use. • No reconstitution or manual mixing needed. • Room temperature storage - No warming/thawing needed. • Open and use operability • Should reach full strength in just two minutes •Should seal, adhere, or reinforce soft tissue in adults. It should be able to be used along with the usual surgical ways to seal tissues, which can include sutures, staples, and/or patches. It should be used for soft tissues of the cardiac, vascular and lung Should seal anastomoses, reinforces friable tissue, and adheres dissected tissues together used for sealing, adhering and reinforcing tissue 10ml 421 Powder dressing(Altrazeal) Should be non resorbable. Should be oxygen permeable Impenetrable to exogenous bacteria and toxins Should be long lasting (>3 weeks)