}

Tender For Providing Additional Infrastructure Facilities At Punnakayal In Thoothukudi District., Tuticorin-Tamil Nadu

Fisheries Department has published Tender For Providing Additional Infrastructure Facilities At Punnakayal In Thoothukudi District.. Submission Date for this Tender is 18-08-2025. Paver Blocking Tenders in Tuticorin Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

50463594
Tender For Providing Additional Infrastructure Facilities At Punnakayal In Thoothukudi District.
Tender
Indian
Tamil Nadu
Tuticorin
18-08-2025

Tender Documents

Tender Details

Tender For Providing Additional Infrastructure Facilities At Punnakayal In Thoothukudi District.; 1 Earth work excavation for foundationby manual means for RR/Brick and Other step type footings for Load bearing structures in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directedbythedepartmental officers. 2 Supplying and filling in foundation, basement,etcwithSandGravel mix in ratio of 1:3 in layers of not more than 15cm thick thoroughly mixed, well watered, rammed with surface vibrator and consolidated etc. complete complying with standard specification and as directedbythedepartmental officers. 3 Supplying and filling in foundation, basement, etc with Stone Dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 4 Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidatedetc. complete complying with standard specification and as directedbythe departmental officers. 5 Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed,consolidatedandincludingcuringetc.completecomplyingwithstandard specification and as directed by the departmental officers. - Mixing by manual means 6 Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers.(Payment for centering shall be given after the concrete is laid). 7 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oakjoists of size 10cm x 5cm& 7.5cm x 5cm as support runner, vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 8 Supplying and erecting steel centering including necessary supportsFor plane surfaces such asrectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). 9 Providing and laying in position, Standardised Concrete Mix M-25 Gradeby insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 10 For Foundation and Basement 11 For Ground Floor up to 4.50 M height 12 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 13 Brick work inCement Mortar 1:5 using best quality Fly ash Brick of size230x110x70mm withclass designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. 14 For Foundation and Basement 15 For Ground Floor up to 4.50 M height 16 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. 17 Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 18 Supplying and painting the walls with two coats of Deco paint with two coats of putty including removing the old paint materials if any from the wall surface using the scrapping materials such as iron brush emery sheet, rough nice and cleaning the wall surface etc., after finishing the scrapping the work to be apply with one coat of water base primer them applying with second coat of putty with necessary scrapping charges up to final smooth finishing ect., finally painted the wall with two coats of plastic emulsion paint of approved and colour and quality, the rate is inclusive of cost of material labour charges and transporting, scaffolding charges ect., complete and as directed by the departmental officers. 19 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 20 Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stoneSand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 21 Paving the floor with kota stone (unpolished) slab of following size in all floors laid over cement mortar bed of 20mm thick in of cement mortor 1:3 (one cement and three crushed stone sand), with required Cement Slurry and Mortar Plasticizer and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc.complete complying with standard speicification and as directed by the departmental officers. (The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work) 22 Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizerand pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 23 Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of U clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers. 24 110mm dia PVC Pipe for One Floor 25 Supplying and fixing GI pipe handrails for handicapped persons using 50mm dia GI pipe double handrail at a height of 800mm and 900mm from floor level with 25mm thick MS square rods as balusters embedded in the concrete and welded with pipe at 60cm centre to centre as shown in CA Job No. 9123 / 1 including cutting, welding, bending and fixing charges and applying one coat of red oxide primer for MS members as directed by the departmental officers 26 Wiring with 2x1.5 sqm (22/0.3) PVC insulated unsheathed SC.Cu Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.T. switch inflush with wall, covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (For electronic regulator) (5 Points per Coil) -SD 22 27 Supplying and fixing of twin box type 4 40W flu fitting complete with copper choke and condensor, with TW round block on wall or ceiling with tubes and PVC unsheathed Copper leads from terminals to the fitting.-SD-90 28 Supply and fixing of 1200 mm (48) sweep AC ceiling fan complete with stepped electronic 300W regulator, with 1 metre down rod with fan clamp with side plates and cross arm of size 450 mm (18) SD - 106 29 Supply and run of 2 of 6sq.mm. (84/0.3) PVC insulated S Cunsheathed FRL Scopper conductor of 1100V grade in 25mm dia GI pipe (Class B) bent at both ends with necessary angle iron up right and end supports for mains. SD No. 71 30 Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earthlink (1x1/8copper flat) on TW plank of size 375mmx300mmx19mm with supporting TWreepers of 1thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and interconnection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1No 40Amp 30MA Double Pole RCD / RCCB (Higher End) with suitable necessary connection.SD No. 125 31 Supply and fixing of 5A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch on suitable TW box connection complete. SD No. 136 32 Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch on suitable TW box connection complete. SD No. 139 33 PLUG AND SOCKETS IN SHEET STEEL ENCLOSURE WITHOUT MCBs (BWD SOR - Page No.194 34 20A Single Pole 35 20A Double Pole 36 VERTICAL THREE PHASE DISTRIBUTION BOARD WITH MCBS 4 way / 8 way / 12 way vertical TPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating One No. 4 pole incoming MCB / Isolator and another separate 4 way provision for accommodatingOne No. 4 pole ELCB / RCD with label holder and provisions for taking up cable for size not lessM- 1898 37 Sub Total Amount for above all items (excluding GST) 38 GST 18% for above SubTotal Amount

Key Value

Document Fees
Refer document
EMD
INR 48500.0 /-
Tender Value
INR 77 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail