| Sl. No. | Item Description |
| 1 | Demolishing R.C.C. work manually/ by mechanical means including stackingof steel bars and disposal of unserviceable material within 50 metres lead asper direction of Engineer - in- charge. |
| 2 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material to the nearest engineering site as per direction of Engineer - in - charge |
| 3 | Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead: Of area 3 sq. metes and below |
| 4 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C.or R.B. work (Payment shall be made on the cross sectional area of R.C.C. orR.B. work) as per direction of Engineer-in-charge. |
| 5 | Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge |
| 6 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sq.m on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, The rate quoted should be inclusive of dewatering. All kinds of soil. |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level . Concrete of M30 grade with minimum cement content of 350 kg /cum. |
| 11 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum. |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-550 |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-550 |
| 14 | Providing fusion bonded Epoxy coating not less than 175 micron thickness and upto 300 micron to reinforcement barsof any diameter as per IS-13620-1993/ ASTM-775 M including repairs to cut ends,welded spouts and handling damages with reccomendedliquid epoxy compatible with the coating and testing of coating at plant etc complete as directed by engineer ion charge. |
| 15 | Centering and shuttering including strutting, etc. and removal of form for Foundations, footings, bases of columns, etc for mass concrete including cost and conveyance of all materials, labour charges etc. complete at all levels as directed by Engineer-in-charge |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 21 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 22 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 23 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 24 | Providing and fixing stainless steel(grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 25 | 12mm cement plaster of mix1:4 (1 cement : 4 fine sand) including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels - Internal plastering |
| 26 | 15 mm cement plaster on the rough side of single or half brick wall of mix : : 1:4 (1 cement: 4 fine sand) |
| 27 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 28 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 29 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) |
| 30 | Providing and supplying heavy duty injection adhesive for rebar fixing using Epoxy resin of 330/500ml HILTI HIT-RE 500 V3/or equivalent for fixing rebar.Embedment depth as mentioned from the Structural consultants, including supplying two component system consisting of resin and hardener in 3:1 ratio; filling above mentioned mortar with standard dispenser before inserting rebar strictly as per the manufacturers recommendations.The installation and the setting instructions should be strictly followed as per the manufacturers recommendations.The chemical anchor shall carry ETA, COLA and DIBT approval and fire approval. Application can be done in both wet & dry concrete condition, corrosion tested. The approved chemical shall beinstalled in hammer drill, diamond coring holes , including cost and conveyance of all materials, labour charges,tool rental charges, lead,liftetc complete as directed by Engineer-in-Charge at all levels. (The above work shall be carriedout by an agency having sufficient experience. Only skilled and experienced persons shall be employed for this purpose.) For fixing 10mm Dia bar with a hole dia of 12- 14 mm. (Excluding the cost of reinforcement ) |
| 31 | Providing and fixing high-performance galvanized steel M12 anchor rod of 125 mm length, 8.8 grade strength of approved make including cost and conveyance of all materials, labour charges, lead, lift, etc complete as directed by Engineer-in-Charge at all levels.(The above work shall be carried out by an agency having sufficient experience. |
| 32 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 33 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 34 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the directionof Engineer-In-Charge. |
| 35 | Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/ appropriate Zsections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessaryfilling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleatangle, Aluminium snap beading for glazing / paneling, C.P. brass / stainlesssteel screws, all complete as per architectural drawings and the directions ofEngineer-in-charge. (Glazing, paneling and dash fasteners to be paid forseparately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 36 | For shutters of doors, windows & ventilators including providing and fixinghinges/ pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber / neoprene gasket required (Fittings shall bepaid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 37 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness) |
| 38 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10x120 mm |
| 39 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm |
| 40 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 asperIS:1868)transparentordyedtorequiredcolourorshade,withnecessaryscrewsetc. complete:125mm |
| 41 | Supplying and fixing 100mm mortice cylinder lock for aluminium door with following specification. a)Hook bolt has to be made of MS and SS for end plate and strike plate with lock set of size minimum 37mm, back set of min 20mm and hock bolt of min 18mm. b)Cylinder should be made of brass with minimum weight 0.20kg with nickel plated brass key(3 sets) and it should be of 5pin brass tumbler mechanism |
| 42 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 43 | Providing and fixing Gysum false ceiling (12.5 mm) at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS Certification marks) |
| 44 | Providing and fixingGypsum Cove (pelmet/cornice ceiling detail) at all levels as per architectural drawings and directions of the Engineer-in-Charge, including forming recessed or curved profiles suitable for indirect lighting using 12.5 mm thick tapered edge gypsum board (IS: 2095 Part I: 2011 with BIS mark) on concealed G.I. framework made of galvanized M.S. sections (120 gsm zinc coating as per IS: 277), including angle cleats, hangers, intermediate channels, ceiling sections, and perimeter channels as per standard spacing and layout. Boards to be screw-fixed with drywall screws, joints finished with tape and jointing compound in three layers with primer, including cutouts for fixtures, all complete as per drawings and direction of Engineer-in-Charge, excluding painting. |
| 45 | Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with Tegular 15 BE Edge Tiles of 17mm thick and Suprafine 15mm face exposed grid. The tiles shall have pin hole visual with Humidity Resistance (RH) of 99%, NRC 0.0.7 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 30db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84with 17mm Tegular 15 BE edge and 8mm drop in module size of 600 x 600mm (nominal). It shall be suitable for Green Building application, with Recycled content of up to 69%. The tile shall have certifications.The tile shall be laid on KCS Suprafine 32 with 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. The Tile & Grid system used together shall carry a 30 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate.The rate is including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels. |
| 46 | Providing & fixing 8 mm thick Calcium Silicate false ceilingat all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture\"s specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. |
| 47 | Providing & Fixing Wooden finished Suspended Ceiling System with Microlook edge tiles and edge profile in exposed grid. The 18mm thick Plain Tile shall be made of Medium Density Fibre of density 700+ Kgs/m3. The tile shall have melamine laminate finish of approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut) on visible side and backing laminate (same shade) on the reverse with 0.8mm matching PVC edge banding in module size of 600mm x 600mm. The edges of the tile shall be Square Tegular/Microlook 90˚ having 8mm drop using 3mm thick compact board spline. The tile shall have Humidity Resistance (RH) of 70%, with sag limited to 1/300mm. The tile shall have a Fire Performance of class 1 according to BS 476 part 7. The tile shall be laid on 15 mm wide T - section flanges having double stroke rotary stitching on all T - sections i.e. the Main Runner at a spacing of 1200 mm and cross tee at a spacing of600 mm with a web height of 38 or 43mm (all sections) as per manufacturers reccomendation. The deflection loading of the system shall be 12.5-15.6 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360 within suspension points) with deflection loading of 15.5 - 18.6kg/m2. The end details of the main beam and cross tee shall be made of pre hardened steel clip fixed to the ends. The cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”.All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T - Sections shall be made of hot dipped galvanized steel of 100 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability.The rate is including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels.Suspension System consist ofaccessories manufactured and supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs connected to the RCC Slab /structural steel system. Additionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners.The rate shall include cost and conveyance of all materials, labour charges etc. complete at all levels as directed by Engineer-in-charge. Contractor should submit detailed design and corresponding calculations of design of all structural suspension system of metallic false ceiling, structural steel support and shop drawings vetted bya consultant in accordance with design parameters specified by the consultant and the codal requirements of BIS (Bureau of Indian Standards) latest version, all relevant safety codes etc as per the direction of theEngineer-in-Charge. Vetting shall be in the scope of the Contractor. Only skilled and experienced persons shall be employed for this purpose and should ensure guarantee for installation, ceiling panels and supporting system for & a period of 10 years from the date of completion of the said work. The measurement shall be taken along the girth on the bottom side of the ceilings, in square meters and deduction shall be made for all openings exceeding 0.4 Sqm in area. |
| 48 | Procuring healthy grass free from weeds and foreign materials and laying on the soil medium as turfing,the rate include for grass cost, transport to site, cost and application of manure, planting, labour, supervision and maintenance for 2 months after plantingPearl Grass |
| 49 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Eugenia Topiary |
| 50 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Clerodendrum Inerme -Hedge |
| 51 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Murraya Exotica - Flower bush |
| 52 | Supplying , stacking and spreading sludge / well decayed farm yard manure from thesource,Mixing earth and manure or in proportion specified or directed, Spreading ofdung manure or / and good earth in required thickness.and fine dressing the ground as per natural gradiantapproved by the engineer in charge incl. screening, loading, unloading, conveyance and stacking at site. |
| 53 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 54 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin-charge). |
| 55 | MEP |
| 56 | WIRING |
| 57 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 58 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 59 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 60 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 61 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 62 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 63 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 64 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 65 | 20 mm |
| 66 | 25 mm |
| 67 | 32 mm |
| 68 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 69 | 5/6 A switch |
| 70 | 2 way 5/6 A switch |
| 71 | 15/16 A switch |
| 72 | 3 pin 5/6 A socket outlet |
| 73 | 6 pin 15/16 A socket outlet |
| 74 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 75 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 76 | 1 or 2 Module (75mmX75mm) |
| 77 | 3 Module (100mmX75mm) |
| 78 | 4 Module (125mmX75mm) |
| 79 | 6 Module (200mmX75mm) |
| 80 | 8 Module (125mmX125mm) |
| 81 | MCCB, MCB & DB’S |
| 82 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door |
| 83 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door |
| 84 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door |
| 85 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 86 | Double pole |
| 87 | Triple pole |
| 88 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 89 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 90 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 91 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 92 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 93 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 94 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 95 | Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copperconductorsingle core cable in surface / recessedmedium class PVC conduit,with modular switch, modular plate,suitable GI box and earthing the point with 1.5sq.mm.FRLS PVCinsulatedcopper conductor single core cable etc. as required for;Two light controled by one switch. |
| 96 | S\" type M.S. fan hook fabricated from suitable dia. S.S. rod/Anger Bolt duly painted for fixing of ceiling fan. The \"S\" type hook shall be fixed to steel bar in RCC ceiling. The ceiling shall be replastered with sand, cement & neeru etc. The cost of labours for chipping out ceiling upto steel bar & fixing of \"S\" hook & resurfacing the ceiling is included in the cost of item |
| 97 | CABLE TRAYS |
| 98 | FRP Cable Tray |
| 99 | Supply of the following sizes of Ladder Type FRP cable trays with vertical sides on both ends as per approved design and FRP supports with coupler plates spaced 300mm apart throughout the length as specified, including the cost of support hooks, fasteners, painting if required etc.( Contractor shall ensure to use corrossion free materials as support or fastening fittings)150mm(150x100x25) |
| 100 | 300mm(300x100x25) |
| 101 | LIGHT FITTINGS / FANS |
| 102 | SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans |
| 103 | LED Downlight Recessed Fitting 15 W |
| 104 | LED Downlight Recessed Fitting 12 W |
| 105 | LEDRecessedLuminaire 36Watts |
| 106 | LED Linear Fixture 20Watts 4ftSurface Mounted |
| 107 | Mirror Light 5W |
| 108 | Ceiling Fan -1200 mm ( BLDC) |
| 109 | Exhaust Fan-450 mm |
| 110 | Bollard Lights |
| 111 | 50W Flood Light |
| 112 | LED STRIP LIGHT WITH DRIVER HAVE Aluminium powder coatedPROFILE -5 Mtr |