Tender For Maintenance And Repairs To Cooling Appliances, Voltage Stabilizers And Connected Items; 1 Attending day to day complaints pertains to cooling appliances of any capacity/make/size/type for Split ACs, refrigerators, water coolers, Deep freezers of any capacity, by deploying one High skilled mechanic and one helper for, identifying/rectifiying any type of faults, repairing / replacing unserviceable parts, replacing the drain pipe (PVC ) and overflow pipe(PVC) checking/dressingup of electrical wirings/ circuitsetc wherever necessary to keep the cooling appliances in good working condition including top up of refrigerant gas up to required pressure all as specified and directed by the Engr-in-charge. Note : (i)Spare parts required for replacement shall be meauseured and paid for seperately under respective items under supply only items.(ii)The contractor’s refrigerator mech/ Technician alongwith T&P should be made available immediately when ever his services are required to rectify any nature of fault.(iii) Contractor/his Technician has to obtain complaints from MES office at 0900 Hrs daily and complaint should be rectfied within 24 Hrs and not more than 72 Hrs, If contractor fails to rectify complaint within 72 Hrs then the amount recovered shall be double of quoted rate for per complaint. (iv)Contractor has to provide register for maintaining records of maintenance carried out and it is the responsibility of the contractor to get the signature of user & JE/Engineer-in-charge on the register for carrying out maintenance. The register shall be maintainedand to be produced to Enginner-in-Charge whenever demanded. (v) Minor parts such as nut , bolts, washers, shall deemed to be included in rate quoted by the contractor and nothing shall be paid on this account. 2 Material and labour for dismantling indoor/out door unit of air conditioner from its postion in any situation and height and all conected items kept with safe custody, opening of indoor/out door assembly complete, servicing and maintenance of cooling appliances includingcleaning of indoor/outdoor units with water including soup solutionby using pressure jet pump , cleaning of Air filter and air outlet grills with a soft dry cloth, cleaning of air inlet(use a vacuum cleaner to removedust from the air inlet), cooling coil , condenser coil (using water jet pump), oiling tofan motor, cleaning ofcompressor etc, fan motor/blower motor, wiping with dry cloth reassamble the AC units, refixing the same in exsisting position and testing of airconditioner with proper function with out leak free all as directed 3 Material and labour for mechanically leak testing of split AC indoor/outdoor unit of capacity 1.0/1.5/2.0/3.0 TR including filling of nitrogen gas for pressure testing,finding leak, brazing of leaked copper pipes, including gas (Refrigerant) charging upto the required pressure, testing after job done for proper functioning complete including rexing the same in existing position all as specified and as directed by Engr-in-charge.(Guarntee shall be given for a period of six months) 4 Supply only factory reconditioned harmatically sealed compressor unit of Spli AC 1.0 ton capacity including initial charged of gas and oil complete as per existing specification and make all as specified and directed by Engineer-in-Charge. ( Note: Fixing under item No.1). Make: Gmcc/ Kirloskar Copland/ Carrier/ Goderej/ Bluestar/ Toshiba 5 All as per item No 4above but for 1.5 Ton capacity Split AC. ( Note: Fixing under item No.1). Make: Gmcc/ Kirloskar Copland/ Carrier/ Goderej/ Bluestar/ Toshiba 6 All as per item No 4above but for 2.0 Ton capacity Split AC.( Note: Fixing under item No.1). Make: Gmcc/ Kirloskar Copland/ Carrier/ Goderej/ Bluestar/ Toshiba 7 All as per item No 4 here in before but for3.0 Ton capacity split AC.( Note: Fixing under item No.1). Make: Gmcc/ Kirloskar Copland/ Carrier/ Goderej/ Bluestar/ Toshiba 8 Supply only Fan blade suitable for out door unit of split type AC1/1.5/2.0 Ton capacity.( Note: Fixing under item No.1). (Make : Universal/GE Motors or equivalent) all as per sample. 9 Supply onlyFan motor 1440 RPM suitable for out door unit of split type AC, 1.0/ 1.5 T.R capacity. ( Note: Fixing under item No.1). Make: AE/ American universal/ Carrier/Amtrex/Bluestar/ Fedders lloyed/Videocon/Hitachi etc. all as per sample. 10 -Ditto- all as per item No. 9 but for split type AC, 2.0 T.R capacity.( Note: Fixing under item No.1). Make: AE/ American universal/ Carrier/Amtrex/ Bluestar/Fedders lloyed/Videocon/Hitachi etc. all as per sample. 11 All as per item No. 9 here in before but for split type AC, 3.0 T.R capacity.( Note: Fixing under item No.1). Make: AE/ American universal/ Carrier/Amtrex/Bluestar/ Fedders lloyed/Videocon/Hitachi etc. all as per sample. 12 Supply only blower motor for split type AC non inverter typeindoor unit of 1.0/ 1.5 Ton capacity. ( Note: Fixing under item No.1). Make: AE/ Carrier/Amtrex/Bluestar/ Fedders lloyed/Videocon/Hitachi etc. as per sample all as specified and directed by Engineer-in-charge. 13 All as per item No 12 inverter typeindoor unit of 1.0/ 1.5 Ton capacity. ( Note: Fixing under item No.1). Make: AE/ Carrier/Amtrex/Bluestar/ Fedders lloyed/Videocon/Hitachi etc. as per sample all as specified and directed by Engineer-in-charge. 14 All as per item No. 12 but for indoor unit of 2.0 Ton capacity non inverter typesplit AC. ( Note: Fixing under item No.1). Make: AE/ Carrier/Amtrex/Bluestar/ Fedders lloyed/Videocon/Hitachi etc. as per sample all as specified and directed by Engineer-in-charge. 15 All as per item No. 12 but for indoor unit of 2.0 Ton capacity inverter typesplit AC. ( Note: Fixing under item No.1). Make: AE/ Carrier/Amtrex/Bluestar/ Fedders lloyed/Videocon/Hitachi etc. as per sample all as specified and directed by Engineer-in-charge. 16 All as per item No. 12 but for indoor unit of 3.0 Ton capacity split AC.( Note: Fixing under item No.1). Make: AE/ Carrier/Amtrex/Bluestar/ Fedders lloyed/Videocon/Hitachi etc. as per sample all as specified and directed by Engineer-in-charge. 17 Supply only runningcapacitors 36-60 MFD for split type air conditioners.( Note: Fixing under item No.1). Make: Keltron/ Bajaj/ Epcos/ Carrier totaline 18 Supply only running capacitor 2.5 to 4/5/6 MFD for fan motor of Split type AC. ( Note: Fixing under item No.1). Make: Keltron/ Bajaj/ Epcos/Havells/ Carrier totaline 19 Supply and repair of printed circuitboard (PCB) of non inverter type air conditioner andtemperature digital display sensor removing from air conditioner testing on bench and replace the unserviceable electronic items any type and refixing the same positionsuitable for split type AC 1.0/1.5/2.0/3.0 T.R capacity.( Note: Fixing under item No.1). (Make : Carrier/Amtrex/Fedder Lloyed/LG or as per sample) all as specified and directed by Engineer-in-charge. 20 Supply and repair of printed circuitboard (PCB) indoor unit of inverter type air conditioner andtemperature digital display sensorremoving from air conditioner testing on bench and replace the unserviceable electronic items any type and refixing the same positionsuitable for split type AC 1.0/1.5/2.0 T.R capacity.( Note: Fixing under item No.1). (Make : Carrier/Amtrex/Fedder Lloyed/LG or as per sample) all as specified and directed by Engineer-in-charge. 21 Supply and repair of printed circuitboard (PCB) outdoor unit of inverter type air conditionerremoving from air conditioner testing on bench and replace the unserviceable electronic items any type and refixing the same positionsuitable for split type AC 1.0/1.5/2.0 T.R capacity.( Note: Fixing under item No.1). (Make : Carrier/Amtrex/Fedder Lloyed/LG or as per sample) all as specified and directed by Engineer-in-charge. 22 Removing the split type AC both indoor and outdoor units of any capcity from the existing locaion/ position and refixing in new locaion/position including pump down of gas, disconnection of suction and discharge pipes, boring of hole in new location, provision of PVC sleeve, connecting back the suction and discharge pipes with addition of new lengths of suitable size if required upto 2 m length each, pressure testing, gas charging if required to maintain the required pressure upto 60 psi, leak testing complete all as specified and directed by Engr-in-charge 23 Supply only Air filter suitable for split type ACs of any size and make.( Note: Fixing under item No.1). 24 Supply only condensing coil with copper tube and aluminium fins of capacity 1/1.5 TR suitable for split AC .(Make: LG/Carrier/Voltas/Samsung)or as per existing specification and make all as specified and directed by Engineer-in-charge.( Note: Fixing under item No.1). 25 All as per item No 24 above but 2 Ton capacity 26 Supply only cooling coil with copper tube for indoor unit of split type AC capacity 1/1.5/2 TR .(Make: LG/Carrier/) or as per existing specification and make all as specified and directed by Engineer-in-charge.( Note: Fixing under item No.1). 27 Dismantling the perishedinsulation and supply and fix nitrile rubber insulation of size 5/8 for suction and liquid refrigerant linefor split type AC.all as specified and directed by Engineer-in-charge. 28 Supply onlycopper tube 3/8 or 5/8 in repairs with nitrile rubber insulation .( Note: Fixing under item No.1). 29 Supply only copper tube 1/4 or 1/2 in repairs with nitrile rubber insulation.( Note: Fixing under item No.1). 30 Supply only factory made outdoor unit stand complete set with fastening nut bolts/washers etc for fixing out door split type AC of any size and capacity.( Note: Fixing under item No.1). 31 Supply only Brass suction valve for split type AC 1.5/2.0/3.0 TR.( Note: Fixing under item No.1). 32 Supply only Brass discharge valve for split type AC 1.5/2.0/3.0 TR.( Note: Fixing under item No.1). 33 Supply only Remote control unit to operate exsisting air conditioner unit with required operating functions as per OEM recommandation suitable to Voltas, Samsung, LG air conditioner units all as directed 34 material and labour comprehensivemaintenance water doctor water coolar of any capacity for the period of 11 months for regular checkup by OEM and cleaning/servicing of cooler with replacement of pre and fine water filter interwal of 6 month period and ensure proper fuction round the clock all as directed 35 Supply only factory reconditioned harmatically sealed compressor unit of water coolers of 40/80 ltr capacity including initial charging of gas and oil complete as per existing specification and make all as specified and directed by Engineer-in-Charge.( Note: Fixing under item No.1). Make: Kirloskar/ Godrej / Techumes 36 All as per item No. 35 but for water coolers of60/120 ltr capacity. ( Note: Fixing under item No.1).Make: Kirloskar/ Godrej / Techumes 37 Supply only factory reconditioned harmatically sealed compressor unit of refreigerators of capacity 165/180 ltr including initial charging of gas and oil complete as per existing specification and make all as specified and directed by Engineer-in-Charge.( Note: Fixing under item No.1). Make: Kirloskar/ Godrej / Techumes 38 All as per item No. 37 but for refreigerators of 286/310 Ltrs capacity.( Note: Fixing under item No.1). Make: Kirloskar/ Godrej / Techumes 39 Supply only blower motor for water cooler of 40/80 Ltr capacity.( Note: Fixing under item No.1). Make: AE/ Carrier/Bluestar/Videocon or as per sample held in office. 40 All as per item No 39 here in before but forwater cooler of 60/120 Ltr capacity.( Note: Fixing under item No.1). Make: AE/ Carrier/Bluestar/Videocon or as per sample held in office. 41 Supply only thermostate suitable for water coolerof capacity 40/80 & 60/120 Ltrs capacity.( Note: Fixing under item No.1). Make: Annapurna/ Infos /. 42 All as per item No. 41 here in before but suitable for refrigerator of any capacity and make.( Note: Fixing under item No.1). 43 Supply only relay forwater coolers suitable for 40/80, 60/120 Ltrs capacity.( Note: Fixing under item No.1). 44 All as per sl item No.43 here in in before but of refigerator of any capacity and make.( Note: Fixing under item No.1). 45 Supply only OLP (Over Load Protection)for water coolers of any capacity as per sample.(Note: Fixing under item No.1). Make: Indfos/ Annapurna . 46 All as per sl item no.45 here in before but of refigerator of any capacity and make as per sample.( Note: Fixing under item No.1). Make: Indfos/ Annapurna . 47 Supply only starting capacitors 60 - 100 MFD for water coolers.( Note: Fixing under item No.1). Make: Keltron/ Bajaj/ Epcos/Havells 48 Supply only runningcapacitors 25/36/40 MFD for water coolers.( Note: Fixing under item No.1). Make: Keltron/ Bajaj/ Epcos/ Havells/ Carrier totaline 49 Pressure testing/ leak arresting ,vaccumising gas/oil charging, includingreplacing the unserviceable strainers and capillary tubes if required etc.., testing complete for Water cooler 40/80 or60/120 or150/150 Ltrs capacity. 50 Material and labour for refrigerant gas charging with replacement of dryer fillter in refrigerator/deep fridger any type and capacity complete and checking of its proper function all as directed and specified 51 Supply only self closing taps cast copper alloy, chromium plated, 15 mm dia suitable for water coolers. ( Note: Fixing under item No.1). 52 Supply only PVC connection 15 mm size with PTMT nuts of length 600 mm.( Note: Fixing under item No.1). 53 Supply only 3 Core,2.5 sqmmcopper conductor flexible cable heavy duty PVC insulated sheathedcable suitable for water cooler/Refrigerator/AC.( Note: Fixing under item No.1). 54 Supply only 3 Core, 4 sqmmcopper conductor flexible cable heavy duty PVC insulated sheathedcable suitable for water cooler/Refrigerator/AC.( Note: Fixing under item No.1). 55 Supply only 5 amps plug top, 240 volts.( Note: Fixing under item No.1). make: Anchor/Cona 56 Supply only 15 amps plug top, 240 volts.( Note: Fixing under item No.1). make: Anchor/Cona 57 Supply only CabinetLED lamp for refrigerator as per sample.( Note: Fixing under item No.1).