| 1 | De-sludging and cleaning of septic tank, manhole, sludge chamber etc by manual digging out and lifting of concerntrated sludge including dewatering and cleaning, removing silt, sludge , sludge water and any other foreign materials and depositing the same into excavated pits exceeding 1.5m depth at places ( n exc 100m) as directed by the Engr-in-Charge returning and filling in excavated earth after depositing sludge including sludge water and sprinkiling bleaching powder as per requirement over surrounding area and removing surplus excavated soil nearby areas complete all as specified and as directed. (Note : Measurement shall be made for sludge incl sludge water). |
| 2 | Cleaning of chocked sewer line of any description by mechanically driven vechile system and flushing with water for 150mm/200mm dia size of pipe complete all as specified and as directed.Note:- (i) Payment shall be done based on actual ground measurement taken while cleaning blokage of sewage line.(ii) Blockage shall be cleared with in 48 hrs after recieving the complaint otherwise penalty @ Rs 500/dayshall be leviedfor the period the complaint is not attended for the clearence of blockage. |
| 3 | Cleaning of chocked sewer line of any description by rodding with green bamboo stick/cane stick and flushing with waterfor 200mm dia size of pipe complete all as specified and as directed.Note:- (i) Payment shall be done based on actual ground measurement taken while cleaning blokage of sewage line.(ii) Blockage shall be cleared with in 48 hrs after recieving the complaint otherwise penalty @ Rs 500/dayshall be leviedfor the period the complaint is not attended for the clearence of blockage. |
| 4 | Cleaning of chocked sewer line of any description by rodding with green bamboo stick/cane stick and flushing with waterfor 150mm dia size of pipe complete all as specified and as directed.Note:- (i) Payment shall be done based on actual ground measurement taken while cleaning blokage of sewage line.(ii) Blockage shall be cleared with in 48 hrs after recieving the complaint otherwise penalty @ Rs 500/dayshall be leviedfor the period the complaint is not attended for the clearence of blockage. |
| 5 | Cleaning of chocked sewer line of any description by rodding with green bamboo stick/cane stick and flushing with water complete all as specified for 100mm dia size of pipe.Note:- (i) Payment shall be done based on actual ground measurement taken while cleaning blokage of sewage line.(ii) Blockage shall be cleared with in 48 hrs after recieving the complaint otherwise penalty @ Rs 500/dayshall be leviedfor the period the complaint is not attended for the clearence of blockage. |
| 6 | Taking out of existing nahani trap/floor trap including grating and cleaning of sludges/ silt from Nahani trap/ floor trap including roding CI pipe from Nahani trap/floor trap to gully trap etc in position using bamboo stick/cane stick or any other useful means and placing the existing oval access door in original position including removing the rubbish/sludge to a diatance exceeding 250m not exceeding 500m complete all as specified and directed.Note:- (i) Payment shall be done based on actual ground measurement taken while cleaning blokage of sewage line.(ii) Blockage shall be cleared with in 48 hrs after recieving the complaint otherwise penalty @ Rs 1000/dayshall be leviedfor the period the complaint is not attended for the clearence of blockage. |
| 7 | Cleaning the blockage in IWC, EWC, including rodding CI pipe after opening the oval asses door of CI bend , CI branch piece (T) etc up to first MH using bamboo stick/cane stick or any other useful means and placing the existing oval access door in original position including removing the rubbish/sludge to a diatance exceeding 250m not exceeding 500m complete all as specified and directed.Note:- (i) Payment shall be done based on actual ground measurement taken while cleaning blokage of sewage line.(ii) Blockage shall be cleared with in 48 hrs after recieving the complaint otherwise penalty @ Rs 1000/dayshall be leviedfor the period the complaint is not attended for the clearence of blockage. |
| 8 | Taking out of gully trap cover and CI grating and cleaning of sludges /silt from gully traps including rodding SGSW/CI pipe and gully trap to first manhole (length n exc 3 Mtr) and placing the existing CI grating , gully trap cover etc in original position including removing of rubbish /sludge outside the premises complete all as specified and directed.Note:- (i) Payment shall be done based on actual ground measurement taken while cleaning blokage of sewage line.(ii) Blockage shall be cleared with in 48 hrs after recieving the complaint otherwise penalty @ Rs 500/dayshall be leviedfor the period the complaint is not attended for the clearence of blockage. |
| 9 | Mechanically pumping out sewage water from Septic tanks/sump well where required and as directed with taking precautionary measurers including tools & plants as required and removing to place out side MOD land from the site and damp in a pet of size 1mx1mx1man sprinkle adquate amount of leaching powder after covering with earthcomplete(working in foul condition) all as specified and directed.Note:- (i) Payment shall be done based on actual ground measurement taken while cleaning blokage of sewage line.(ii) Pumping outshall be done with in 48 hrs after recieving the complaint otherwise penalty @ Rs 500/dayshall be leviedfor the period the complaint is not attended for the clearence of blockage. |
| 10 | Excavation in trenches by mechanical means (Hydraulic excavator) n.exc. 1.5m wide and n.exc. 1.5m in depth for taking up/laying sewer lines and getting out in any kind of soil complete all as specified and directed. |
| 11 | All as per item No. 10 above but exc. 1.5m and n.exc. 3.0m deep complete all as specified and directed. |
| 12 | Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed. |
| 13 | Removing of excavated soil to a distance n.exc 50m and depositing where directed at alevel n.exc 1.5m above starting point complete all as specified and directed. |
| 14 | Demolition and breaking up drain pipes 100mm dia ( Salt Glazed ware, AC or reinforced concrete) set in cement mortar including PCC bed and haunching and removal of debris outside the MD land complete all as specified and directed. |
| 15 | All as per item No.14 above but 150mm dia complete all as specified and directed. |
| 16 | All as per item No. 14 above but 200mm dia complete all as specified and directed. |
| 17 | M&L for Salt Glazed Stoneware pipes grade \"A\",100mm bore,laid in trenches and jointed complete all as specified and directed. |
| 18 | All as per item No. 17 herein before but 150mm bore complete all as specified and directed. |
| 19 | All as per item No. 17 herein before but 200mm bore complete all as specified and directed. |
| 20 | M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) for bed to drain pipe 100mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 21 | All as per item No. 20herein before but bed to150mm bore complete all as specified and directed.. |
| 22 | All as per item No. 20herein before but bed to 200mm bore complete all as specified and directed. |
| 23 | Dismantling of cast iron or reinforced concrete drain pipes 100mm dia, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 24 | Dismantling of cast iron or reinforced concrete drain pipes 75mm dia, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 25 | S&Ffor 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ringjoints fixed to wall/trenches etc using synthetic rubber adhesive cement solventcomplete all as specified and directed. |
| 26 | S&F for 110mm dia PVC (SWR) bend any radiuscomplete all as specified and directed. |
| 27 | S&F for 110mm dia PVC (SWR) bend with acess door any radiuscomplete all as specified and directed. |
| 28 | S&F for 110mm dia PVC (SWR) branch piece single (Single T ) equal or unequal complete all as specified and directed. |
| 29 | S&F for 110mm dia PVC (SWR) vent cowl complete all as specified and directed. |
| 30 | S&Ffor 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ringjoints fixed to wall/trenches etc using synthetic rubber adhesive cement solventcomplete all as specified and directed. |
| 31 | S&F for 75 mm dia PVC (SWR) grade bends of any radius complete all as specified and directed. |
| 32 | S&F for 75 mm dia PVC (SWR) grade bends with acess door of any radius complete all as specified and directed. |
| 33 | S&F PVC (SWR) branch piece, single (SingleT ) of radius equal or unequal, 75mm dia complete all as specified and directed. |
| 34 | S&F PVC (SWR) vent cowl, 75mm dia complete all as specified and directed. |
| 35 | M&L for applying two coats of cement based paint over a coat of primer including preparation of new plastered surfaces complete all as specified and directed. |
| 36 | Demolition of RCC cover slab for manholes etc complete all as specified and directed. |
| 37 | M&L for pre-cast reinforcement cement concrete (1:2:4) Type B-1, using 20 mm graded crushed stone aggregate as in cover slab for manholes etc.and set in cm 1:6 complete all as specified and directed. |
| 38 | S&F TMT bars 10 mm dia and over and cut to length bent to shape required including cranking, bending, hooking ends and bending with MS wire not less than 0.9mm dia or securing with clips quality conforming complete all as specified and directed. |
| 39 | Demolition of Bricks or stone masonry built in cement mortar complete all as specified and directed. |
| 40 | M & L for brick work with sub class \"B\" bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:4) as in manholes, septic tank, filter bed, walls, drains etc complete all as specified and as directed. |
| 41 | M&L for Pre-cast cement concrete block masonry with solid blocks type C1 (1:3:6) (20mm graded crushed stone aggregate) set in CM 1:6, exc. 10 cm in width and setting in mortar complete all as specified and directed. |
| 42 | Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in external surfaces of man holes, septic tank, filter bed etc incl removing of debrie complete all as specified and directed. |
| 43 | M & L forrendering 15mm thick on brick or concrete surfaces of walls in CM (1:4) (using water proof compound @ 3% of total cement used or as per manufacturer\"s instruction including finishing the surfaces even and smooth without using extra cement as in manholes, septic tank, filter bed out let drain by using water proofing compound etc complete all as specified and directed.Note:- W.P.C will be measured andpaid under the relavant item. |
| 44 | Supply of Integral waterproofing compound complete all as specified and directed. |
| 45 | Demolition of cement concrete (un-reinforced ) in ground floors and pavings not exceeding 15cm thick (below or above ground level ) complete all as specified and directed. . |
| 46 | M&L for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 47 | M&L for Plain cement concrete type C1(1:3:6)( using 20mm graded crushed stone aggregate) as in surface chanels and drains complete all as specified and directed. |
| 48 | M & L for Plain cement concrete type-B1(1:2:4) (using 20mm graded crushed stone aggregate ) as in benching coping etc incl necessary form work complete all as specified and directed. |
| 49 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed. |
| 50 | M&L for 75 mm thick plain cement concretetype D-2 (1:4:8) (using 40 mm graded crushed stone aggregates) as in sub basecomplete all as specified and directed. |
| 51 | M&L for 50mm thick plain cement concrete in (1:3:6) type C1 using 20 mm graded aggregate as in plinth protection finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 52 | S&F forchequered cement concrete tiles 30cmx30cmx25mm thickwith grey cement and pigment set jointed and pointedin neat cement slurry laid over and including 20 mm thick screed bed of cement mortor (1:6) in floors complete all as specified and directed. |
| 53 | M&L for Cutting into existing manholes for 100mm dia connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 54 | M&L for Cutting into existing manholes for 150mm dia connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 55 | M&L for Cutting into existing manholes for 200mm dia connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |