Tender For Special Repair Renovation Electrical Works Of Employees State Insurance Corporation Kanshbahal Hospital - Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : 2 Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. 3 Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. 4 M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. 5 Suitable cement concrete foundation duly plastered with anti vibration pads. 6 1620 lpm at 70 m Head 7 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) 8 Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. 9 Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 voltselectric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. 10 M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. 11 Suitable cement concrete foundation duly plastered with anti vibration pads. 12 1620 lpm at 70 m Head 13 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) 14 Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. 15 Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. 16 M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. 17 Suitable cement concrete foundation duly plastered with anti vibration pads. 18 180 lpm at 70 m Head 19 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approvedshade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductorcable/solid copper strip, having switchgears andaccessories, mountings and internal wiring, earthterminals, numbering etc. complete in all respect,suitable for main fire pump, pressurisation pump &diesel pump set complete as per CPWD specificationwith following in coming and Outgoings, suitable foroperation on 415V, 3 phase, 50Hz Ac Supply withenclosure protection class IP 42 as required : 20 Incomings 21 250A, 50kA 4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich & CTsetc.LED type RYB phase indicating lamps, ON, OFF,tripindicating lamps Set of Copper Bus Bar 300A 22 Outgoings 23 OUTGOING( Note : All outgoing feeders for pumps should havedigital Ammeter with selector switches, and LED typeON, OFF, trip indicating lamps). 24 Main Fire Pumps 25 Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fullyautomatic Star/Delta starter suitable for 60 HP pumpwith overload protection, current sensing type singlephase preventor complete with all acceessories andinternal wiring required for automatic operation,selector switch for local/remote, auto/manual/OFFoperation. 26 Jockey Pump 27 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitableHP fully automatic Star/Delta starter with overloadprotection, current sensing type single phase preventorcomplete with all acceessories and internal wiringrequired for automatic operation, selector switch forlocal/remote, auto/manual/OFF operation. 28 Diesel Engine Control 29 Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts startingdevice, timers and relays as required, push buttons,start/stop in manual modeIndicating lamp for high/ Low 30 Indicating lamp for high/ Low Lub. Oil pressure, HighWater Temp and Engine on indication.Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine 31 System Controller 32 Designing, Supply, Installation, Testing andcommissioning of system controller to control operationof main electric fire pump, diesel pump, Pressurizationpump, Terrace pump in sequence as per specificationconsisting of relays, timers. Sensors, annunciationwindow for fault indication, complete as perspecification 33 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 34 Pipes, cables etc. exceeding 80 mm dia. but notexceeding 300 mm dia 35 Providing, laying, testing & commissioning of B classheavy duty G.I. pipe conforming to IS 1239 includingwelding, fittings like elbows, tees, flanges, tapers, nuts,bolts, gaskets etc. and fixing the pipe on the wall/ceilingwith suitable clamp/support frame and painting with twoor more coats of synthetic enamel paint of requiredshade complete as required : 36 25 mm dia 37 32 mm dia 38 40 mm dia 39 65 mm dia 40 80 mm dia 41 100 mm dia 42 150 mm dia 43 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 44 Single headed Stainless steel 45 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 46 Single headed Stainless steel 47 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts,washers, gaskets conforming to IS 13095 of following sizes as required : 48 65 mm dia 49 80 mm dia 50 100 mm dia 51 150 mm dia 52 200 mm dia 53 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 54 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 55 80 mm dia 56 100 mm dia 57 150 mm dia 58 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 59 150 mm dia 60 100 mm dia 61 80 mm dia 62 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 63 Stainless Steel (Grade 304) 64 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 65 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 66 20 mm nominal internal dia gun metal globe valve & nozzle. 67 Drum and brackets for fixing the equipmets on wall. 68 Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 69 40 m 70 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable fornstantaneous connection to interconnect hose pipe coupling as required : 71 Stainless Steel (Grade 304) 72 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 73 2 way - 100 mm dia M.S. Pipe 74 4 way - 150 mm dia M.S. Pipe 75 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 76 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 77 Pendent Sprinkler 78 Upright Sprinkler 79 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. 80 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 81 100mm dia 82 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 83 150mm dia 84 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 85 700 mm 86 1000 mm 87 1200 mm 88 Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required. 89 Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. 90 25 mm 91 Supplying and installing following size of perforated pre-painted GI. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI. suspenders including bolts & nuts, painting suspenders etc as required. 92 150 mm width x 50mm depth x 1.6 mm thickness. 93 Control cable copper 2 core 1.5 sq.mm 94 Providing and fixing of Weather proof hose cabinets fabricated from 14 g M.S. Sheet with full glassdoor and mortise locking arrangement , suitable to accommodate one Hydrant landing valve, 2 nos. 15 M long hose and 1 No branch pipe. The cabinet shall be painted with one coat of primer and finished stove enamelled Fire Red, Fire Hose written on front including suitably mounted on a raisedmasonry platform as required. (Approx 0.75mx0.6 m x 0.25 m). 95 Providing and fixing MS partly glazed single/double hung lockable shutter fabricated from MS section as required with5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words Fire Hydrant written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire mans axe, fire extiguishers 2 nos, including suitably mounted on a raisedmasonry platform as required. (Approx.size 0.90mm x 2.1mm ) 96 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 97 Providing, erection testing, Commissioning of Cast Iron Foot Valve/Stainer confirming to IS:4038/1538 complete with flanges, nuts, bolts and washer etc as required 98 Providing andfixing resilient rubber neoprene lined single archvibration eliminators with unit control suitable for raw water upto 450C temperature workingpressure 25 kg andtestpressure 37.5 kg/cm2. 99 80 mm dia. 100 100 mm dia 101 150 mm dia 102 Providing and fixing heavy dutyPVC insulated, PVC armoured conductor cables 1100 V grade including necessary supportclamps and connection lugs complete in all respects. 103 Power cable 3.5 core 150 sq mm aluminium conductor armoured cable 104 Power cable 3 core 16 sq mm aluminium conductor armoured cable. 105 Supply, Installation, Testing & Commissioning of double flanged vertical air vessel fabricated shell from 10 mm thick & dished ends 12 mm thick M.S.plate, suitable for working pressure of 18 kg/cm2 and test pressure of 27 kg/cm2, 450 mm dia and 2.00m high for fire pumps complete with four nos dual setting pressure switches to operate jockey and main pumps at drop of pressure as given in the specifications. 106 Providing & fixing 150 mm diameter MS Class ‘C’ for diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the diesel engine. The pipe shall be provided insulation with fibre glass wool and wraped with 24g. aluminium sheet complete with all respect. 107 Providing and fixing of gun metal fire Brigade Suction Hose coupling (Draw-out Connection) with nut for female coupling as per IS:902- 1974 complete with 100 mm dia. G.I. Suction pipe and 100 mm dia. 1No. C.I. Foot valve flanged (to be connected to static water tank). 108 Providing and fixing carbon-di-oxide type fire extinguishers consisting of pressure tested single cast cylinder with rotary discharge valve and high pressure discharge tube of minimum 1 m length, discharge horn, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge (Halon Free Gas) 109 Capacity 4.5 Kg. 110 Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. (Halon Free Gas) 111 Capacity 6.0 Kg. 112 Providing and fixing 25 mm dia inspecting & testing assembly with drain valve built in bye pass arrangement andconnection to drain line.(Giocomini) 113 Supply & Installation, testing and commissioning 2 or3 HP Single Phase open well Submersible monoblock water cooled pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guardmake) . 220v 50hz, 2900rpm with control panel/starter. 114 Two nos. of pump installed in one sump pit 1 working & 1 standby with automatic/manual operation as requireds. 115 Waste Water Sump Pumps 116 Flow rate:4.0 LPS 117 Head : 10 Mtrs. 118 Min. Motor HP : 2 (Each) 119 Set of 2 pumps (1duty +1 stand by) 120 Supply and Fixing of of 4 mm thick Anti Corrosive PipeProtection Bituminous Tape With Primer as required. 121 Supply and Fixing of Dewatering/Wastewater/Sewage Collection submersible pump with alloy tip cutter with volume capacity 700m3/hr and 48 Mtr Head with IP68 Protection and self cooling facility. 122 Estimate of FIRE ALARM at ESIC Hospital Kansbahal Odisha. 123 INTELLIGENT FIRE ALARM SYSTEMSupply, Installation,Testing & Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) & minimum 120 detectors per loop & loop length up to 2 km, network communication card,minimum 320 character graphics /LCD display with touch screen or other keypad & minimum 4000 events history log in the non volatile memory (EPROM) power supply unit (230±5% V,50 hz),48 hrs back-up with 24 volt sealed maintenance free batteries with automaticcharger.The panel shall have facility to connect printer to printout log and facilityto have seamless integration with analog /digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories.The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specifications.Two Loop Panel 124 Supplying, Installation, Testing & Commissioning of Repeater Panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 125 Supplying, Installation, Testing & Commissioning of Intelligent Analog Addressable Photothermal Detector complete with mounting base complete as required. 126 Supplying, Installation, Testing & Commissioning of Fault Isolator complete with base as required. 127 Supplying, Installation, Testing & Commissioning of Intelligent Addressable Thermal Detector with rate of rise cumfixed tempreature thermistor complete with base as required. 128 Supplying, Installation, Testing & Commissioning of Addressable Fire Control Module complete as required. 129 Supplying, Installation, Testing & Commissioning of Addressable Phone Control Module complete as required. 130 Supplying, Installation, Testing & Commissioning of Addressable Manual Call Point complete as required. 131 Supplying, Installation, Testing & Commissioning of Addressable Horn Cum Strobe complete as required. 132 Supplying & Laying of 2x1.5 Sqmm Fire Alarm Armoured Cable, 600/ 1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 133 Supplying, Installation, Testing & Commissioning of Addressable Phone Control Module complete as required. 134 Supplying , installation, Testing & Commissioning of 6 Zone, Voice alarm controller with USB, MP3 Player (Including 6 Zone button paging station) with seamless integration facility with main fire alarm Panel for Voice evacuation complete as required. 135 Supplying, Installation, Testing & Commissioning of 6 inches dia, 2 Watt, 70/100 volts Ceiling speaker complete as required. 136 Supplying, Installation, Testing & Commissioning of Voice command keypad 6 Zone, with microphone assembly complete as required 137 Supplying and drawing of Cable Fire Retardant PVC insulated copper Conductor cable in the existing surface/recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.Speaker cable single pair, 2-core, 1.5 sqmm 138 Supplying and Fixing 25 mm dia MS Flexible pipe with PVC Coating along with all ancillaries and accessories like coupler etc as required. 139 Supply and installation of 15/20/30 Watt Volume Controller to control sound of the PA Speaker with all Accessories like Face Plate, Boxes, Nuts and Bolt and Screw etc compatible with speaker. 140 Supply,Installation,Testing and Comissioning of Photo Lumine scent Non Toxic, Non-Radio active maintenance free self glowing Exit Signs Compri sing Zink Sulphide Chargeable Crystels wich glows in dark. Printed on U-1000 Photo Luminscent aluminum sheet containing Luminscent 111 as base chemical cover with U/V stabilized coating and mounting arrange ment for Wall/Ceiling mounting as per site conditions.The colour combin ation & size of the letters shall be as per IS:12349 Amended up to date.4 mm ACRYLIC SHEET BASED P.L. SIGNAGE 18X6=108 Sq.Inch (400 X 150 MM) 141 Supply and Installation of Fire Evacuation Floor Plan Maps of various sizes as per Site requirements Specifications:-drawing and drafting of Emergency Evacuation Plan by the Supplier of with the help of cerified Architect. Site Plan may not be available made on heigh intensity self Glow Photo Luminscent sheeting required mm thick Vinyl foam board 24 X 18 inches.Make :– Prolite/ Glowlite/ / Mr.Lite 142 Signage of Battery Billed 143 Construction of 1 Lakh Under gorund Water Tank and Underground Pump Room with 40 Thousand Litres water tank for ESI Hospital Kanshbahal Reg. 144 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil. 145 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil 146 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 40 mm nominal size). 147 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 148 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). 149 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 150 Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 151 Providing and laying 75 mm thick compacted bed of dry brickaggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineerin- charge. 152 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturers specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R2010 i.e. by reducing permeability of concrete by more than 90%,compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 153 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 154 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) 155 15 mm cement plaster on the rough side of single or half brick wall of mix : 156 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete 157 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 158 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 159 DSR Cost Index Rate 160 Supplying Including installation commissioning of Normal and Solar Street Light in ESIS Hospital Kanshbahal 161 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 armoured U.G. cableU.G. cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 162 3 Core A2XWY A2XFY 163 10.00 Sq.mm 3 Core armoured U.G. cable 164 Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting vertical TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar 125A and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 165 ABB, Schneider MG, legrand, Hagermake) 166 12 way TPN (8+36)single door 167 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 168 6 to 32 169 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 170 63A 171 Supplying, installation of pre galvanised sheet steel std thickness 1.6mm under floor trunking including necessary nuts and bolts, washer etc. as required, as directed and specified by the department. (MK/ LEGRANDmake) Size 172 JUNCTION BOX 173 250x250x60 - 75 mm Depth 174 Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 175 C Series (ABB, Schneider MG, legrand, Hagermake) 176 6 to 32 177 40 A 178 Erection of metallic pole of following length in cement concrete1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refillingetc. as required. 179 Above 6.5 metre and upto 8.0 metre 180 Above 8.0 metre and upto 10.0 metre 181 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 182 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 183 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 184 Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise ortwilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.2 output per phase and suitable for single phase supply 185 SITC of Hot Dip galvanised octagonal pole with 6 metre height with base plate welded at bottom with necessary Nut and Bolt. 186 SITC of Hot Dip galvanised octagonal pole with 12 metre height with base plate welded at bottom with necessary Nut and Bolt with necessary chain system for fixing/pulling of light. 187 Supply and Fixing, testing of 200 Watt Flood LED light complete work in all respect. 188 Supply and Fixing, testing of 72-75 Watt streetLED light complete work in all respect 189 Round bracket ( To be mount on pole) Suitable for mounting upto 4 No. of 200 Watt LED light 190 Supply and Fixing of Single ARM Bracket Hot Dip Galvanised GI make complete fixing with Nut Bolt in street Light complete work in all respect 191 Supplying including installation, testing and commissioning of 40W-60W All in One Solar Street Light LED Outdoor Waterproof Lamp for Home Garden,Die cast Aluminium(Cool White-Pack of 1)-Replaceable Battery.Solar Panel : 5V/45W MonocrystallineBattery : 3.2 LiFePo4 48AHLumens : 10000 lmMaterial Composition : AluminiumWaterproof Rating: IP65Color Mode: Cool WhiteCharging Duration: 6-8 hoursOperating Duration : 12-15 hours 192 Construction of underground 30+10 KLD STP Cum ETP Civil Tank and Operation room and Plant room at ESI Hospital Kanshbahal. 193 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil. 194 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil 195 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 40 mm nominal size). 196 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 197 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). 198 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 199 Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 200 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineerin- charge. 201 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturers specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R2010 i.e. by reducing permeability of concrete by more than 90%,compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capableof self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 202 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) 203 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) 204 15 mm cement plaster on the rough side of single or half brick wall ofmix : 205 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, includinguse of chequered plate wherever required, all complete 206 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 207 Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade :Two or more coats on new work 208 DSR Cost Index Rate 209 ELECTRO-MECHANICAL ITEMS 210 Supply & Installation of BAR SCREEN-15- MOC-SS 304 211 Supply & Installation of RAW SEWAGE TRANSFER PUMP along with all accessories Capacity-4 m3/hr,Head-10 m Make- Kirloskar/Lubi/KSB/Willo/Equiv 212 Supply & Installation of PROCESS AIR BLOWER (Along with all accessories) Capacity-70 m3/hr,Pressure-6 psig Make- Airvac/Akash/Tirupati/Kay/Equiv 213 Supply & Installation of MBBR MEDIA (5 Make-Plastic 214 Supply & Installation of TUBE SETTLER MEDIA (5 Cum) MOC-Plastic 215 Supply & Installation of SLUDGE RECIRCULATION PUMP along with all Capacity-2m3/hr,Rating-1 HP Make-Kirloskar/KSB/Lubi/Willo/Equiv 216 Supply & Installation of FILTER PRESS FEED PUMP along with all accessories Capacity- 1m3/hr,Rating-1HP Make-Roto/ /Rotomac/Equiv 217 Supply & Installation of FILTER PRESS along with all accessories Size-18 X 12, 18nos.plate Rating-1HP, Make-Delhi Filter Press 218 Supply & Installation of FILTER FEED PUMP along with all accessories Capacity-6 m3/hr,Rating-2 HP, Make- Kirloskar/KSB/Eqv 219 Supply & Installation of MULTI GRADE FILTER along with all accessories Dim.-400 mm Φ x 1650 mm HOS MOC-MS Make- Aventura/Pentair/Aquanomics/Equiv 220 Supply & Installation of ACTIVATED CARBON FILTER along with all accessories Dim.-400 mm Φ x 1650 mm HOS MOC-MS Make- Aventura/Pentair/Aquanomics/Equiv 221 Supply & Installation of SOFTENER FILTER Capacity-3.5 m3/hr MOC-MS Make- Aventura/Pentair/Aquanomics/Equiv 222 Supply & Installation of UF SYSTEM along with all accessories Capacity-3 m3/hr,Rating- 2.0HP Make-Grafil/Hydramem/Hydraunautics/Equiv. 223 Supply & Installation of UV SYSTEM along with all accessories Capacity-3 m3/hr MOC-SS,Rating-0.35HP 224 Supply & Installation of DOSING SYSTEM along with all accessories Capacity-50litMake-E Dose/M Dose 225 Supply & Installation of all types PIPE LINE &FITTINGS (uPVC/GI/cPVC etc. 226 Supply & Installation Earthing, ElectrcalCables Casing pipe & Fittings etc 227 Supply & Installation CONTROL PANEL alongwith all accessories, including appropriate rating of MCCB and MCB Controller. 228 Engineering drawing & design of STP 229 Erection & Commissioning of STP Plant with Consultation with PCB Odisha including Providing of NOC. 230 ELECTRO-MECHANICAL ITEMS 231 Supply & Installation of BAR SCREEN-15-25MM 232 Supply & Installation of RAW EFFLUENT TRANSFER PUMP along with all accessories. Capacity- 2 m3/hr,Head-10 m Rating-1.0 HP, Make-KSB/Kirloskar/wilo/Eqv 233 Supply & Installation of PROCESS AIR BLOWER(Along with accessories) Capacity-50 m3/hr,Rating-2.0HP,Make-Kay/Airvac/Eqv 234 Supply & Installation of SLUDGE RECIRCULATION PUMP along with all accessories. Capacity-1.0 m3/hr, Head-10m, Rating-1HP, Make- KSB/Kirloskar/Eqv. 235 Supply & Installation of FILTER FEED PUMP Capacity-4.0m3/hr, Head-20m, Rating-1 HP 236 Supply & Installation of MULTI GRADE FILTER along with all accessories. Size-400mm X 1600 mm MOC-FRP, Make-Aventura/Aquanomics/Eqv. 237 Supply & Installation of ACTIVATED CARBON FILTER along with all accessories. Size-360mm X 1600 mm MOC-FRP, Make-Aventura/Aquanomics/Eqv 238 Supply & Installation of CHLORINE DOSING PUMP along with all accessories Capacity-0-6LPH, Rating-0.35HP, Make-EDose/Eqv 239 Supply & Installation of PIPE LINE & FITTINGS 240 Supply & Installation of CABLES 241 Supply & Installation of CONTROL PANEL along with allaccessories. 242 Drawings & design of ETP 243 Erection & Commissioning of ETP 244 18% GST