| 1 | Supply, installing, testingand commissioning Outdoor type LT feeder pillar box suitable for accommodate the following accessories, pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double door, front side openable, type IP 54 protection made of CRCA sheet 3.15 mm thick of size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Platform min 45 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including dismantling old unsv LT feeder pillar box / busbar chamber etc complete with the following items housed in :-BUSBAR :- 400 Amps rated Alumuniumbus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulatorbus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of Alumunium busbar).INCOMING:- (i)4 pole MCCB of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal magnetic release type - 01No. (ii) Digital multifunctional meter V, A, F, kW- 01 No.(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set(iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with thermalmagnetic release, adjustable type with rotary handle - 04 Nos(b) 4 pole MCCB of capacity 63 Amp, breaking capacity 25 KA with thermalmagnetic release, adjustable type with rotary handle - 01 Nos. |
| 2 | Supply, installing, testingand commissioning Outdoor type LT feeder pillar box suitable for accommodate the following accessories, pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double door, front side openable, type IP 54 protection made of CRCA sheet 3.15 mm thick of size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Platform min 45 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including dismantling old unsv LT feeder pillar box / busbar chamber etc complete with the following items housed in :-BUSBAR :- 600 Amps rated Alumuniumbus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulatorbus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of Alumunium busbar).INCOMING:- (i)4 pole MCCB of capacity 400Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal magnetic release type - 01No. (ii) Digital multifunctional meter V, A, F, kW- 01 No.(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set(iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 250Amp, breaking capacity 25 KA with thermalmagnetic release, adjustable type with rotary handle - 01 Nos(b) 4 pole MCCB of capacity 200 Amp, breaking capacity 25 KA with thermalmagnetic release, adjustable type with rotary handle - 03 Nos. |
| 3 | Supply, installing, testingand commissioning Outdoor type LT feeder pillar box suitable for accommodate the following accessories, pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double door, front side openable, type IP 54 protection made of CRCA sheet 3.15 mm thick of size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Platform min 45 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including dismantling old unsv LT feeder pillar box / busbar chamber etc complete with the following items housed in :-BUSBAR :- 600 Amps rated Alumuniumbus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulatorbus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of Alumunium busbar).INCOMING:- (i)4 pole MCCB of capacity 400Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal magnetic release type - 01No. (ii) Digital multifunctional meter V, A, F, kW- 01 No.(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set(iv) CT (200/5A) -03 Nos OUTGOING:- (iii) Outgoing :-(a) MCCB 200 Amps, 3 Pole, 36 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal and fixed magnetic release - 02 Nos(b) MCCB 163 Amps, 3 Pole, 25 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal magnetic release - 01 Nos(c) MCCB 100 Amps, 3 Pole, 25 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal magnetic release - 02 Nos |
| 4 | Supply, installing, testingand commissioning Outdoor type LT feeder pillar box suitable for accommodate the following accessories , pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double door, front side openable, type IP 54 protection made of CRCA sheet 3.15 mm thick of size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Platform min 45 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including dismantling old unsv LT feeder pillar box / busbar chamber etc complete with the following items housed in :-BUSBAR :- 600 Amps rated Alumuniumbus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulatorbus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of Alumunium busbar).INCOMING:- (i)4 pole MCCB of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal magnetic release type - 01No. (ii) Digital multifunctional meter V, A, F, kW- 01 No.(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set(iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 250 Amp, breaking capacity 25 KA with thermalmagnetic release, adjustable type with rotary handle - 04 Nos(b) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with thermalmagnetic release, adjustable type with rotary handle - 02 Nos. |
| 5 | Supply, installing, testingand commissioning Outdoor type LT feeder pillar box suitable for accommodate the following accessories , pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double door, front side openable, type IP 54 protection made of CRCA sheet 3.15 mm thick of size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Platform min 45 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including dismantling old unsv LT feeder pillar box / busbar chamber etc complete with the following items housed in :-BUSBAR :- Alumuniumbus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulatorbus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of Alumunium busbar).(The rating of main bus bar shall be 1.5 times of ampere rating of incomer and outgoing bus bar rating shall be 1.5 times of ampere rating of each outgoing MCCB.) and continuous earth bus with GI strip of suitable size capable for carrying full short circuit current for 1 sec shall be provided at bottom of the panel.INCOMING:- (a) Air Circuit Breaker (ACB), 630 Amps, 4 Pole, 50 KA (Ics = Icu = Icw for 1 Sec), 415 Volts, 50 Hz, Manual Draw Out (MDO) type with microprocessor based release - 01 No(ii) Digital multifunctional meter V, A, F, kW- 01 No.(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set(iv) CT (200/5A) -03 Nos OUTGOING:- (b) 4 pole MCCB of capacity 250 Amp, breaking capacity 25 KA with thermalmagnetic release, adjustable type with rotary handle - 06 Nosa) 4 pole MCCB of capacity 63 Amp, breaking capacity 25 KA with thermalmagnetic release, adjustable type with rotary handle - 02 Nos. |
| 6 | S&F of Bus bar chamber with door type of size 400 x 380 x 190 mm made out of MS sheet 3mm thick with copper bus bar three phase & neutral each 320 x 20x6 mm of size fixed on insulators and fixing on steel pole with proper clamps, nuts, bolts & washers of required size and making connection of LT cables with thimbles, glands and making good the disturbed surfaces including water proof PVC sticker like danger mark complete all as specified and directed. |
| 7 | Supply and installation, connecting electrically & commissioning in replacement of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with arrangement mounted on angle iron legs made out of angle iron of size 40 x40 x6mm, 1.0 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30 x 0.30x 0.50 mtr -04 Nos duly painted with two coats of synthetic paint over a coat of red oxide complete with 200 Amps rated copper bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 200 Amps 4 pole 415 volts, 35/36 kA complete all as specified and directed. |
| 8 | M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using galvanised iron strip 32x6mm as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil reaming surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge incl testing on completion. |
| 9 | S&F in replacement of Cable jointing kit for 1100 volt grade cable for outdoor/indoor termination end joint heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 16 to 35 Sqmm 3.5/4 core. |
| 10 | All as per item No 9 but for 6 to 25 Sqmm 4 core size. |
| 11 | All as per item No 9 but for 50 to 95 Sqmm 3.5 core size. |
| 12 | All as per item No 9 but for 120 to 185 Sqmm 3.5 core size. |
| 13 | Supply and fix in replacement of aluminium strip 25 x 3.15 mm with saddles and fixing screws, insulators rawal plugs etc forconductor for roof and fixed on wall upto test point all as specified. |
| 14 | Supply and fix in replacement of galvanized iron strip 32 x 6 mm fixed with saddles & fixing screws, PVC dash fasteners, insulators fixed from test point to earth on walls or buried in ground /drawn into hume pipe. NOTE : Excavation & earth work shall be measured and paid for separately under relevant item of schedule. complete all as specified and directed. |
| 15 | Supply and fix in replacement of wooden block heavy weight of size 30x30x30 cm with hole of 20 cm for fixing of air termination rod of any size incl dismantling and taking down old existing unserviceable wooden block complete all as specified and directed. |
| 16 | Supply and fix in replacement of GI tubes light grade, galvanised, 20 mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for fixing of air terminationincl dismantling and taking down old existing unserviceable GI tubes lightgrade complete all as specified and directed. |
| 17 | Supply and fix in replacement of five pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed. |
| 18 | Supply and fix in replacement of Test point terminal block made of gun metal or phosphorous bronze 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point completed all as specified. |
| 19 | M & L forPCC 1:3:6 (nominal mix) type C-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concreteincluding necessary frame work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site. |
| 20 | Dismantling from insulators and taking down ACSR conductor any size from LT over head lines. |
| 21 | Supply and fix laying & testing of aerial bunched cable 1100 volt grade stranded and aluminiumconductor 4 core x 25 Sqmm,(three phase and one neutral), 16 Sqmm (insulated messenger) , electric power cables (heavy duty) 1100 volts grade withstranded aluminum conductor including all fittings such as anchor clamp, suspension clamps, inline connector, cable protection and dead construction, in cluding taking down unserviceable cable all as per IS , specified & directed. |