Tender For Provision Of Certain Essential Facilities For Modenisation In Bldg No. P-15,P-50 And P-57 At 5 Brd And Covered Sentry Shed At Afs Sulur.; 1 SCHEDULE A BOQ 2 Dismantling ceiling boards any description, any thickness including cover fillets all as directed. 3 S&F 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately) complete all as spd and as directed 4 Gl frame work for seamless c e i l i n g c o m p r i s i n g o f G l perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clipsa c r o s s t h e i n t e r m e d i a t e channel at 457 mm centre to centre complete all as spd and as directed. 5 S&F Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut tolength, bent to shape required, including cranking, bendingand hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as spd and as directed 6 S&F of Collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets,complete all as spd and as directed 7 Demolition of brick work built In cement mortar,including all quoin,arches.pillars etc but excluding ashlar facing,dressed stone work and precast concrete articles complete all as spd and as directed. 8 Taking down chowkhat or frame(wooden/steel) not exceeding1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed. 9 Taking down shutters of any description exc 1.0 Sq.m andn.exc 2.0 Sq.m each complete all as specified and directed. 10 Taking down Chowkats or frames with shuttersexceeding 1.5 Sq.m each but n exc 4 sq.m eachcomplete all as specified and directed. 11 M & L for Brick work with fly ash brick subclass B straight or curved on plan exc 6 m mean radius built in CM 1:4 complete all as directed. 12 Material and labour for Ist class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put togather with glue pinned at joints all as specified and as directed. 13 M&L Flush shutters,30mm thick, solid core construction, with particle board core and ply wood face panels, commercial type on both sides,complete all as specified and directed. 14 Material and labour for I st class HW35 mm thick Glazed and skeletonshutter open rebated and prepared to receive glass , gauge, etc with sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.24 (a) and fitted to chowkatscomplete all as specified and as directed by Engineer-in-Charge. 15 S&F 10mm thick tempered toughenedglass glazing securing with oil putty /brads in squareexc 0.5 sqm in each panescomplete all as specified and directed. 16 S &F of solar control film 25micron reflective type sticked to glass panes as per instruction of manufacurs complete all as specified and directed. 17 M & L for Preparing old surface of wood and wood based material of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. 18 S & F 150 mm sizeBrass Butt hinges medium weight complete all as spd and as directed 19 S & F 150 mm sizeBrass barrel tower bolts, with cast or sheet barrel and rolled orcast bolts and fixed complete all as spd and as directed 20 S&F150 mm size brass handles fancy type ,,polished bright complete all as spd and as directed 21 S&F of Brass, sliding door boltwith sand or die-cast brass hasp, staple (bolt type) length of bolt 250mm and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed. 22 S & FFloor door stopper 150mmlong with cover plate of brass body and tongue with hard drawn steel spring complete all as specified and directed. 23 M&L forFrench polishing on surfaces of any description, width or girth including cleaning ,and preparing the surface including a coat of wood filler on new works with two or more coats all as directed 24 M &L for Preparation of new wood or wood based surfaces over 10 cm width or girth and applying twocoats of synthetic enamel paint over a coat of pink primer all as specified and directed. 25 M &L for Preparation of oldsteel surface over 10cm in width or girthand applying one coat of synthetic enamel paint all as specified and directed 26 S&F brassMortice lock vertical type100 mm size 4 levers including escutcheon plates and two keys complete all as specified and directed. 27 S&F Aluminium ( Extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg fixed in Repairs all as specified and directed 28 Cutting holes in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall exc half brick but not exc one brick complete all as specified and directed. 29 M&L Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisescomplete all as specified and directed. 30 M & L for Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tilesexceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 complete all as specified and directed. 31 M & L for Vitrified Ceramic tiles 10 mm thick,dark shade (square/ rectangular) polished, area of each tilesexceeding 0.38 sqm, but not exc 0.42 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6complete all as specified and directed. 32 All as per item No 31 above but as in skirting/Dado 33 S&F of Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to fe 290 grade E165 complete all as specified and directed. 34 Supply and fixing factory made uPVC white colourThree track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi- chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. 35 Demolition of concrete in above ground floors and pavings n. exc 15 cm thick complete all as spd and as directed 36 M&L 100mm thick, plain cement concrete (1:2:4), type B-1 (using 20 mm graded mechanically crushed stone aggregates),as in hardstanding , surface finished even and smooth without using extra cement, spike rolling to surface or making of expendable metalwhilt the concrete is green complete all as specified and as directed. 37 M&L 25 mm thick cement concrete type B-0,1:2:4 (12. 5mm graded aggregate) as in sub base of floors all as specified. 38 M & L for preparingnew steel and iron surfaces any description over 10 cm in width or girth, priming with red oxide and applying two coats of synthetic enamel paint complete all as specified and directed. 39 M & L for preparingold steel and iron surfaces any description n exc 10 cm in width or girth , and applying two coats of synthetic enamel paint complete all as specified and directed. 40 M&L for Granite (of any type) 20mm thick machine cut, bedded and jointed with gray cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete in window cill, cooking platform and includingM& L for15mm thick screed bed in CM (1:4) complete all as specified and as directed. 41 M&Lfor Rounding to edges of stone slabs one edge,such as in steps, cooking platform, and other similar situations complete all as specified and directed. 42 M&L for Rendering in CM 1:4, 10 mm thick on fair faces of stone wall work or concrete surfaces .in cement mortar 1:4 ,finished even and smooth with out using extra cement, including taking down exising plastering of any descriptioncomplete all as specified and as directed. 43 M&L for Rendering 15 mm thick in two layers onbrick or stone or concrete surfaces,first coat 10mm thick in cement mortar1:6 and 2nd coat 5mm thick in cement mortar1:4 mixed with water proofing compound as per manufacturer instructionsfinished even and smooth without using extra cement including taking down exising plastering of any description completeall as specified and directed.Note: Water proofing compound shall be measured and paid seperately. 44 supply only integral water proofing compoundcomplete all as specified and directed. 45 Supply and fixmineral fibre acoustical suspended ceiling system with 600x600x16mm classic lite (Bevelled Tegular) edge tiles with Armstrong 15mm exposed grid. The tile laid on Armstrong superfine 38 with 15mm wide T section flanges colour white having rotary stiching on allsection ie. the main runner 1200mm & 600mm cross tees with a web height of 38mm and load carrying of 12.5Kg/sqm and pull out strength of 100 Kgs.The T section have a Galvanising of 90 gm/sqm and need to be installed with suspension system of Armstrong make. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200x600 mm module.Cut cross tee longer than 600mm require independent support.600x600 mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.Permeter trim shall be Armstrong wall angles of size 3000x24x24mm, secured to walls at 450mm maximum centres.Anchor fasteners with verticle Hangers made out of galvanised steel of size 26x26x1.2mm with a galvanised thickness of 80 gms, pre-straightened hanger wire of dia 2.5mm and length of 1.8m, thickness of 80gms, and a tensile strength of 344-413 MPG alongwithadjestable hook clips or 0.8mm thich galvanised spring steel for 2.68mm with a minimum pull strength of 110 kg.The adjestable clip also consists of a 3.5mm Quiline wire to be used with main runner complete all as specified and directed. 46 S&F PVC (SWR) pipes single socktet in any length with hlaf bend , etc withrubber ring joints laid fixed to walls withsuitable PVC brackets for150 mm bore as in rain water pipe complete all as specified and directed. 47 Material and labour for preparation of newly plasteredwall surfaces,applying 3 mm thick wall care putty andapplyingtwo coats of oil emulsion distemper over acoat of chalk whiting primer completeall as specified and as directed. 48 M&L complete removal of existing treatment of old plastered wall surface applyingtwo coats of distemper oil emulsion over a coat of primer ( Chalk whitening ) with3 mm thick wall care puttyall as specified and directed. 49 M&L for along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. 50 M&L for treatment of soil under existing floor by drilling vertically 12mm dia holes at the junction of floor and wall, crumble junction etc 300mm a part and injecting chemical emulsion @ 1 ltr per hole incl plugging 12mm dia holes with CM 1:2 to match with the existing floor completed all as directed by Engr-in-Charge 51 M&L for providing and injecting chemical emulsion at the point of contact of wood work (in oil or kerosion based solution ) at the rate 0.5ltr per holes by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre incl plugging the holes ect complete all as directed by Engr-in-Charge 52 S&F 25 mm dia SS drapery rod , including brackets, decorative knobs at both ends & curtain rings 8 Nos (minimum) completeall as speccified and directed. 53 S&F 5mm figured glass, ordinary quality ,n exc 0.5 sqm in each glass all as specified and directed. 54 Removing buildingmaterialout side the campus including loading and unloading etc., to a distance exc 5.0 Km but not exc 10.0Km out side the MD land ( Ministry of Defence)where responsibility regarding place of deposition and permission from all authorities etc., in this regard will be of contractor and allas specified. Note : Location and Permission of deposting the disposal out side the MD land shall be rest with contractor at his own arrangement complete all as specified and directed. 55 S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of apperture 1.40 mm and fixed withstainless steel wire staples complete all as specified and directed. 56 S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of apperture 1.40 mm and fixed withstainless steel wire staples complete all as specified and directed. 57 M&L 30mm thick glazed and skeleton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc complete provided with stiles and rails as specified in SSR part-I section 8clause 8.24 (b) complete all as specified and directed. 58 M & L for Framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 complete all as specified and directed. 59 Chipping/removing loose concrete up to reinforcement bars, without damaging the reinforcement, removing all the loose material and to make all the exposedsurface free from dust and all impurities etc. complete allspecified and directed.Note : The work up to three storey building. 60 Removing corrosion of steel reinforcement by mechanical means like wire brushing, chipping to remove loose rust and then applying rust removal solution by using brush application, leaving the surface for at least 15 to 30 minutes, then removing loose materials by scrubbing or with brush and applying polymer bond to the old concrete surface before applying polymer mortar. Note : The work up to three storey building complete all as specified and directed.Make : - SIKA-SIKA Rust off 100 or SIKA S.B.R or latex power complete all as specified and directed.FOSROCK - Reebaklens RR or Nitobond AR. 61 Application of Corrosion Inhibitor Providing & applying One coat of Concrete Penetrating Corrosion Inhibitor (Surface applied) which work on Bipolar Inhibition Mechanism on entire concrete surface to be repaired by using brush or spray at 250 ml per Sq.Mt/Coat or as per manufactures specification and prior to application of frist coat of anti corrosive coating to reinforcement.Note : The work up to three storey building . Make :- SIKA-Feroguard 903 FOSROCK - Auramix BCI 62 Providing and applying priming cum bonding coat of polymer of approved make and quality as approved by Engr-in-charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc. Note : The work up to three storey building complete all as specified and directed. Make:- SIKA- SIKA Latex or SRB FOSROCK - Nitobond EP 63 Providing Micro Concrete jacketing to walls/columns or beams of thickness upto 75mm using polymer modified cement premixed quartz sand aggregate packed in bags of standard manufacture , for high early strength of 40 N/mm sq cm of approved brand.The dry product is to mixed with 12.50% water by weight, along with washed and poured into rigid form work moulds & tamped properly, & cured for 3 days (Payment is to be made by weight premixed of micro concrete product consumed as per site register records. No extra payment shall be made for shuttering or any other material, like scaffoling etc.Note : The work up to three storey building complete all as specified and directed.Make :- SIKA-SIKA Rep microconcrete-4FOSROCK: Rendero CRG 64 Providing and applyingpolymer modified cement mortor of average thickness 15-20mm using Polymer in one or more layers in proportion 1:5:15 of Polymer Cement Quartz Sand as manufactures specification in speific layers, curing after 72 hours of application with wet gunny bags etc and by finishing the surface with 12 mm thick (1:3) Cement sand plaster. Note : The work up to three storey building complete all as specified and directed. Make:- SIKA- Sika 122 WLFOSROCK- Renderoc -S2 65 Providing and applying one coat of structural grade epoxy bond coat by brush conforming to ASTM-C-882-87 to the prepared concrete surface to repaired/strengthened.This is applied prior to the application of polymer repair mortar/epoxy mortar/Microconcrete to have monolithic action between old concretesurface and new concrete surface.Note : The work up to three storey building . Make:- SIKA- SIKADUR 32LP, HIBOND 66 Providing and applyingpolymer modified cement mortor of average thickness 30-40mm using Polymer intwo layers in proportion 1:5:15 of Polymer Cement Quartz Sand as manufactures specification in speific layers, curing after 72 hours of application with wet gunny bags etc and by finishing the surface with 12 mm thick (1:3) Cement sand plaster.Note : The work up to three storey building . Make:- SIKA- Sika 162 HS FOSROCK- Renderoc HS xtra 67 Rakingout joints/pointing Cement mortar inbrick tiles 30cm by 20cm laid flatas in floors, roofs,and M & L forjointed pointed in CM 1:4 mixed with water proofing compound and mixed with 5% crude oil by weight of cement complete all as specified and directed. 68 Supply only approved water proofing liquid complete all as spd and as directed. 69 S&F Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. 70 S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. 71 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil complete all as spd and as directed 72 M&L Cement concrete 1:4:8 type D-2 (40mm grade aggregate) in foundations, filling and mass concrete complete all as spd and as directed 73 M&L cement concrete 1:2:4, Type B1 (using 20 mm graded stone aggregate) cast in situ in lintels/chajjas up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating completeall as specified and directed. 74 Removal of excavated material to a distance exceeding 1.50 Km andnot exceeding 5.00 Km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. 75 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. 76 M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and as directed. 77 M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 with smooth finish without using extra cement complete all as spd and as directed 78 M&L Preparing new surfaces ofplastered or unplasteredwall and applying two coats of cement based paint over one coat of alkali resistant primer complete wash complete ll as specified and directed. 79 M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as spd and as directed 80 M&L Hardcore of broken stone or boulder gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as spd and as directed 81 M&L 75mm thick Plain cement concrete1:4:8type D-2(using 40 mm gradedstone aggregate ) as in sub base complete all as specified anddirected 82 M&L 40mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate Finished even & smooth without using extra cement complete all as spd and as directed 83 M&L RCC 1:2:4, Type B1 (using 20 mm graded stone aggregate) cast in situ in Beams, cantilevers, bressummers,chajjas and lintels over 1.5m span completeall as specified and directed. 84 M & L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels/chajjas, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for rough finished sufaces of concrete complete all as specified and directed. 85 M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9mm dia or securing with clips ®complete all as specified and directed. 86 M&L 75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates),as in plinth protection complete all as specified and as directed. 87 S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 gradeSt.-240) all as specified and as directed. 88 M&L Pre painted Coloured corrugated Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheetany colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws all complete all asdirected. 89 S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding towall, fixed with self tapping screws as specified and as directed by Engineer-in-Charge 90 S & F False ceiling using GI snap grid size 60x60cm with main runner 38x24 wall angle & cross tee 29x24 mm wall angle 24x24 mm suspendede wirh 4mm dia gi wire fixed with steel dash fasteners carrying maxload upto 8.1 Kg/Sqcm with 4mm thick designer ceiling board incl taken down existing one coplete all as specified and directed by Engr -in- Charge (Lake & Hill) all as per Everest regular T 2430 91 S&F Powder coated anodized aluminum frame for door,windows & ventilators with or more rebates including joining cleat for fixing etc. complete all as specified. 92 S&F Powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. 93 S&F Powder coated anodised aluminium window & ventilator shutters, sliding/openable without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified 94 S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade (AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. 95 S&F 4 mm thick, sheet glass, ordinary quality and glazingwithoil putty /beedingin squares exceeding 0.5 sqm each pane for fixing to aluminium/wooden joinery work complete all as specified. 96 M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified. 97 M&L Brass mortice lock, vertical type, size 65 mm of 4 levers complete all as spd and as directed 98 Excavating over areas, n exc 1.5 m deep and getting out complete all as spd and as directed 99 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed offine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. 100 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening whereverrequired complete. 101 M&L for wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl non metalic PVC conduit with accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed to wallscovered with white cover plate with frame etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistrandedcable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for 102 One light point/fan/bell point controlled by one switch 103 All as per item No. 104 here in before but for one switch socket outlet 3 pin 5 Amps on independent board 104 All as per item No 103 above but wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently 105 S&F modular switch 1 way 6 Amps, 1 module complete all as spd and as directed 106 S&F modular switch 1 way 16 Amps, 1 module complete all as spd and as directed. 107 S&Fmodular socket outlet multipurpose 2/3 pin 6 amps, 2 module complete all as spd and as directed. 108 S&Fmodular socket outlet multipurpose 2/3 pin 6/16 amps, 2 module complete all as spd and as directed. 109 S&F white cover plate with frame, 3 Module complete all as spd and as directed. 110 S&F white cover plate with frame, 6 Module complete all as spd and as directed. 111 S&F metal flush box 3 module complete all as spd and as directed. 112 S&F metal flush box 6 module complete all as spd and as directed. 113 Supply and fixing LED round light 12 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. 114 M&L for wallmounted fan 400 mm sweep single phase 230 volts including fixing arrangement on wall/angle all as directed by Engineer -In-Chargecomplete. 115 Supply and fixing factory madepowder coated distribution board SPN 8 way, double doorincluding 200 Amps bus bar, Neutral bar, standard DIN rail, earth bar acomplete all as specified and directed 116 S&F Modular metal flush box made out of MS sheet concealed in walls, modular white cover plate with suitable screws and connectedaccessories for telephone jack and TV antenna outlet complete all as spd and as directed 117 S&F Non-metallic rigid PVC conduit 20 mm dia inclusive of all necessary conduit accessories concealed in wall for telephone wires complete all as spd and as directed. 118 Supply and lay cable XLPE Insulated screened Meter PVC bedded,galvanized steel strip or wire armored, electric power cables (heavy dyty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as spd and as directed. 119 M & L Sub main wiring with 2 runs of 10 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit and conduit accessories consealed in wall,ceiling etc. ISI marked32mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 10 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cableas earth conductor complete as specified. Note : Two runs of 10 Sqmm cable, one run of 10 Sqmm earth conductor shall be measured and paid as one length along with one run of PVC conduit. 120 M & L Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit and conduit accessories consealed in wall,ceiling etc. ISI marked32mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 4 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cableas earth conductor complete as specified. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor shall be measured and paid as one length along with one run of PVC conduit. 121 Supply and fixing load line verticale type TPN DB 4 way double door factory madepowder coated distribution boardway, including suitable capacity bus bar, Neutral bar, standard DIN rail, earth bar and suitable for incommer MCCB upto 100 Amps complete all as specified and directed 122 Supply and fixing MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 36 KA complete all as spd and as directed 123 S&F factory made Double Door sheet metal enclosure DB Vertical TPN 4 way, 200 Amp rated tinned copper bus bar for mountingMCBs complete all as spd and as directed. 124 Supply and fixing singlepole neutral MCB40-63 Amps, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996all as specified. 125 Supply and fixing singlepole MCB 6 to 32 Amps, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996all as specified. 126 S&F metal cladsocket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as spd and as directed. 127 Supply and fixing MCCB 4 pole 160 Amps, 50 Hz,415 volts, with rupturing cap 16 KA complete all as spd and as directed. 128 Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified. 129 M/L for brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed. 130 M&L for Radling sand and punning for cushioning to under ground cable all as directed.Note :- For the purpose of payment only punned thickness shall be measured. 131 M&L for GI pipe ( Light grade ) for protection of LT cable fixed to walls/ poles/road crossing including clamps complete of 40 mm bore complete all as spd and as directed 132 Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth strip 25 x 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre,charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers,PCCchamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified &directed. 133 S&F 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid/surface/roof including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from notless than 110 lumens/watt.The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection not less than 2KV ,permisible limit of CRI range,with recommended burning hours,4000K/6500Ketcfrequency 50 to 60 Hz ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , . PF should be notless than0.95 , THD < 10% . Indivisual LEDs should not be visible for glare free output ,colour temperature 6500k all as directed. 134 Supply and fixing 4 feet, LEDlight fitting18 watts(T-8) with out put of not less than 110lumens/watts , boxtype made with epoxy white powder coated CRCA sheet steel(decorative) light fitting having G13 bipin holders compitable for mounting on wall/ceiling/surface,ermisible limit of CRI range,with recommended burning hours ,4000K/6500Ketc , 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driverconnector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, including provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting with integrated driver ofLED tube rod 4 x 18 watts complete all as specified and as directed. 135 S&F electronicmodular fan regulator 230 volts, step type socket type, hum free 120 watt 2 Module complete all as spd and as directed. 136 S&F ceiling rose, surface type Bakelite 65x55mm3 terminal complete all as spd and as directed 137 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five starrated with brushless direct current motor (BLDC) complete all as spd and as directed 138 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame andlouvers 139 S&Ffactory madepowder coated distribution board TPN, 3-ph,4 way double door,415volts,50Hzincludingbus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCB 40-100Amps,minimum 3pole & minimum kA rating is 10kAas incomer flush to wall/surface conforming to IS and making good of distructed surface. 140 Supply andfixing ofTP, MCB 32 amp, 415 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacityin existing DB complete conforming to IS 8828 of 1996 all as specified. 141 Supply andfixing ofTPN, MCB 40 amp, 415 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacityin existing DB complete conforming to IS 8828 of 1996 all as specified. 142 M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed. 143 M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed. 144 Supply andfixing ofIndustrial power gradesockets inclduing male and female socket and connector capacity up to 32 Amps 415v,50hz,3p+N+E complete all as specified and directed.. 145 Supply andfixing ofIndustrial power grade supply sockets inclduing male and female socket and connector capacity up to 32 Amps 230v,50hz,1p+N+E complete all as specified and directed..