Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-09-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-09-2025 |
| 2 | 20-08-2025 | AMENDMENT TO TENDER DOCUMENTS AND REVISED BOQ | BOQ | 03-09-2025 |
| 3 | 14-08-2025 | REVISED CRITICAL DATES | Date | 03-09-2025 |
| Sl. No. | Item Description |
| 1 | Rewiring (Labour and Mtrl) for light point/Fan Point/Exhaust pointwith 1.5 Sq,mm FRLS PVC insulated multi strandedcopper conductor single core cable and 1.5 sq .mmFRLS PVC insulatedmulti stranded copper conductor single core cable as earth wire in existing surface /recessed steel / PVC conduit including dismantintling/removing of burnt cable from the existing conduit and making good to surface as required complete all as specified and directed. |
| 2 | Rewiring (Labour and Mtrl)for Twin control Light point with 1.5 Sq,mm FRLS PVC insulated Cable muliti starandedcopper conductor single core cable and 1.5 sq .mmFRLS PVC insulatedmulti stranded copper conductor single core cable as earth wire in existing surface/recessed steel/ PVC conduit including dismantintling/Removing of burnt cable as required complete all as specified and directed. |
| 3 | Rewiring (Labour and Mtrl)for circuit /Submain wiring along earth wire with the sizes2x2.5 Sq. mm + 1x2.5 Sq. mm earth wireof FRLS PVC insulatedmulti stranded copper conductor,single core cable in surface /recessed conduit including dismantintling/Removing of burnt cable as required (For Power Plug) complete all as specified and directed.Note: 3runs of cable and one run of conduit shall be measured as one unit length |
| 4 | Point wiring in repair for light point/fan point/exhaust fan point /call bell with 1.5 sq mm FRLS PVC insulatedmulti stranded copper conductor single core cable in surface /recessed medium class PVC conduit,with modular switch,modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated multi stranded copper conductor single core cable etc. including dismantling/ removing of burnt cable/ includingaceessories andmaking good surfaceas per site required complete all as specified and directed. |
| 5 | Point wiring in repair for 5 Amp socket outlet point forIndependent board with 2x 1.5 sq mm single corePVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multistandard copper conductors and earth continuty wire with similar1x1.5 sq mm cablesingle core cable (incl connecting to earth dolly) drawn through andin surface/recessed medium class PVC conduit as required atsitecomplete all as specified and directed. |
| 6 | Supply and fixing in repairsuitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modular socket and 5/6A modular switch ,connection etc. as required atsitecomplete all as specified and directed. |
| 7 | Point wiring in repair for 15/25 power plug/socket outlet point forIndependent board with 2x 2.5 sq mm single corePVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multistandard copper conductors and earth continuty wire with similar1x2.5 sq mm cablesingle core cable (incl connecting to earth dolly) drawn through andin surface/recessed medium class PVC conduit as required atsitecomplete all as specified and directed. |
| 8 | Supply and fixing in repairsuitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 15/16 A modular socketand 15/16A modular switch ,connection etc. as required at site (for 15/25 Power plug) complete all as specified and directed. |
| 9 | S&F in repair Electronic ceiling fan regulator, modular type stepped /socket type heavy duty suitable to work on 230 volts on the existing modular platecomplete all as specified and directed. |
| 10 | Supply & fixing in repair piano type 5/6 amps switch on theexisting Switch box including connectionas required on site complete all as specified and directed. |
| 11 | Supply & fixing in repair piano type 2 way 5/6 amps switch on the existing Switch box including connection as required on site complete all as specified and directed. |
| 12 | Supply & fixing in repair piano type 15/16 amps switchon the existing Switch box including connection as required on site complete all as specified and directed. |
| 13 | Supply & fixing in repair piano type 3 pin 5/6 amps socket outlet switchon the existing Switch box including connection as required on site complete all as specified and directed. |
| 14 | Supply & fixing in repair piano type 6 pin 15/16 amps socket outlet switchon the existing Switch box including connection as required on site complete all as specified and directed. |
| 15 | Supply & fixing in repair piano type Telephone socket on the existing Switch box including connection as required on site complete all as specified and directed. |
| 16 | Supply & fixing in repair 5/6 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site complete all as specified and directed. |
| 17 | Supply & fixing in repair 2 way5/6 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site complete all as specified and directed. |
| 18 | Supply & fixing in repair 15/25 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site complete all as specified and directed. |
| 19 | Supply & fixing in repair 3 pin 5/6modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site complete all as specified and directed. |
| 20 | Supply & fixing in repair 6 pin 15/25modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site complete all as specified and directed. |
| 21 | Supply & fixing in repair modular telephone socketon the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site complete all as specified and directed. |
| 22 | Supply & fixing in repair modular bell push on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site complete all as specified and directed. |
| 23 | Supply and fixing in repair 1or 2 module base & cover plate on existing modular metal boxes etc as required complete all as specified and directed. |
| 24 | Supply and fixing in repair 3 module base & cover plate on existing modular metal boxes etc as required complete all as specified and directed. |
| 25 | Supply and fixing in repair 4 module base & cover plate on existing modular metal boxes etc as required complete all as specified and directed. |
| 26 | Supply and fixing in repair 6module base & cover plate on existing modular metal boxes etc as required complete all as specified and directed. |
| 27 | Supply and fixing in repair 8module base & cover plate on existing modular metal boxes etc as required complete all as specified and directed. |
| 28 | Supply and fixing in repair 12module base & cover plate on existing modular metal boxes etc as required complete all as specified and directed. |
| 29 | Supply and fixing in repair of metal box of size 150mm/75mm/60mm deep (normal size) on surface or in recess with suitable size of modular plates /phenolic laminated sheet cover in front including providing and fixing 3/6 pin 5/6 A Socket outlet 5/6A switch piano/ modular type switch, connections, painting etc. as required complete all as specified and directed. |
| 30 | Supply and fixing in repair of metal box of size 180mm/100mm/60mm deep (normal size) on surface or in recess with suitable size of modular plates /phenolic laminated sheet cover in front including providing and fixing 6 pin 15/16 A Socket outlet 15/16A switch piano/ modular type switch, connections, painting etc. as required complete all as specified and directed. |
| 31 | Supply and fixing in repair PVC batten /angle holder including connections etc as required complete all as specified and directed. |
| 32 | Supply and fixing in repair call bell ding dong suitable for single phase, 230V, complete as required complete all as specified and directed. |
| 33 | Supply and fixing in repair of electronic industrialgongbelltype size upto 10 inch wired door chime, 220 V AC, steel body, wall hanging, suitablefor office complete as required complete all as specified and directed. |
| 34 | S&F in repair ceiling rose PVC/polycarbonate three terminal surface Bakelite complete all as specified and directed. |
| 35 | M & L in repair for PVCsurface mounted Size upto 8 inch Dummy plates/ Plastic modular fan plates / PVC electrical round sheets for covering junction box complete including making good to surface as per site requirement complete all as specified and directed. |
| 36 | Supply and fixing in repair of 25 mm medium class PVC conduit along with acessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed. |
| 37 | S&F in repair in repairs electronic fan regulator socket / steptypeAC 230 Volt complete all as specified and directed. |
| 38 | Supply and fixing in repair LED light fitting 1X20W,220V high efficiency(efficiency upto 100lm/w) polycarbonate batten bright light having high quality material and design,compact appearance simple and versatile in nature makes it as long lasting efficient solution complete all as specified and directed. |
| 39 | Supply and fixing in repair LED light fitting 1X10W,220V highefficiency(efficiency upto 100lm/w)polycarbonate batten bright light having high quality material and design,compact appearance simple and versatile in nature makes it as long lasting efficient solution complete all as specified and directed. |
| 40 | Supply and fixing in repair ofLED 12w/10w LED Downlighter surface /recess typehaving high performance low height back lit downlighter suited for any modern proffessional workspace .Robodust PDC aluminium housing ensures long life.Available in 3000K,4000K,and 5700K CCT.Efficacy :100lm/W complete all as specified and directed. |
| 41 | S & F in repair LED 20W T8 Tube with in built driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection,housing made og high grade polycarbonate cover,2.5 Kv internal surge protection,IP20 ingress protection,Pcb mounted on extruded metal plate complete all as specified and directed. |
| 42 | Supply and fixing in repair of Compact industrialLED box typefitting 1X20W,220Vhaving housing made of CRCA pre coated sheet steel suitable for office havingsingle polycarbonate aluminium and glass tube complete all as specified and directed. |
| 43 | Supply and fix in repairs of Compact industrial batten LED box typefitting 2x20W,220Vhaving housing made of CRCA pre coated sheet steelsuitable for office having twinpolycarbonate aluminium and glass tube complete all as specified and directed. |
| 44 | S&F in repair Building security light fitting LED 45 W, made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to suitable shape out of GI pipe 40 mm bore light grade, 1.5 mtr length and fixed with MS Calmps of size 40x5 mm- 02 nos ,nuts, bolts and washers on wall complete all as specified and directed. |
| 45 | Supplyand fixingin repair of 9 watt LED lamp on the existing holder complete all as specified and directed. |
| 46 | Supply and fixing in repair 4 way,(4+12), Double door surface/recess mounting,vertical type ,415 V,TPN, MCB distribution board of sheet steel,dust protected,duly powder painted ,inclusive of 200 A tinned copper bus bar,common neutral link, earth bar, din bar for mounting MCBs as required complete all as specified and directed. |
| 47 | Supply and fixing in repair 4 way,Double door single pole and neutral sheet steel,MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) complete all as specified and directed. |
| 48 | Supply and fixing in repair 6 way,Double door single pole and neutral sheet steel,MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) complete all as specified and directed. |
| 49 | Supply and fixing in repair 8 way,Double door single pole and neutral sheet steel,MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) complete all as specified and directed. |
| 50 | Supply and fixing in repair 12 way,Double door single pole and neutral sheet steel,MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required complete all as specified and directed. |
| 51 | Supply and fixing in repair 4 way,(4+12) double door horizontal type, Three pole and neutral sheet steel, MCB distribution board, 415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required complete all as specified and directed. |
| 52 | Supply and fixing in repair of 5A to 32 A rating, 240/415V, 10kA \"C\" curve miniature circuit Breaker suitable for inductive load of single pole in the existing MCB DB Complete with connections,testing and commissioning etc as required complete all as specified and directed. |
| 53 | Supply and fixing in repair of 5A to 32 A rating, 240/415V, 10kA \"C\" curve miniature circuit Breaker suitable for inductive load of single pole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc as required complete all as specified and directed. |
| 54 | Supply and fixing in repair of 63 A rating,240/415V, 10kA \"C\" curve miniature circuit Breaker suitable for inductive load of Triplepole and neutralin the existing MCB DB Complete with connections,testing and commissioning etc as required complete all as specified and directed. |
| 55 | Supply and fix in repair MCCB 63 Amp,4 pole 415 volts,16 KA Complete all as specified and directed. |
| 56 | Supply and fix in repair MCCB 100 Amp,4 pole 415 volts,16 KA Complete all as specified and directed. |
| 57 | S & F in repair ofelectricalconcealed wooden box rectangular shapefor electrical fittings of allsizes upto 250 mm x300 mm x 100 mm deepon surface or in recess with suitable size of phenolic laminated sheet cover in frontincludingmountingofpiano flush type switches, sockets, fan regulator, etc bypunching required slots for switches/ Sockets / Regulators as per site requirementincluding taking down of the existing damgedconcealed wooden boxes with back and top and making good to surface as per site requirement complete all as specified and directed. |
| 58 | M&L in repair ofexisting industrial laminated sheet board/hylem sheet/phenolic laminated sheet4/6 mm thick of any size for mountingswitches, sockets, fan regulator, etc bypunching required slots for switches/ Sockets / Regulators as per site requirement including taking down the existinglaminated top cover complete all as specified and directed. |
| 59 | Supply and fixing in repair of casing and caping of size upto 50 mm including removing of old unserviceable one complete all as specified and directed. |
| 60 | S&F in repair in repairs switch socket combination 5 Ampwith PVC box suitable for 230 Volt complete all as specified and directed. |
| 61 | S&F in repair in repairs switch socket combination 15 Amp with PVC box suitable for 230 Volt complete all as specified and directed. |
| 62 | Wirirngin repair for circuit /Submain wiring along earth wire with the sizes2x4 Sq. mm + 1x4 Sq. mm earth wireof FRLS PVC insulated copper conductor,single core cable in surface /recessed conduit including dismantintling/Removing of burnt cable as required complete all as specified and directed. |
| 63 | Wirirng in repair for circuit /Submain wiring along earth wire with the sizes2x 6 Sq. mm + 1x6 Sq. mm earth wireof FRLS PVC insulated copper conductor,single core cable in surface /recessed conduit including dismantintling/Removing of burnt cable as required complete all as specified and directed. |
| 64 | Wirirng in repair for circuit /Submain wiring along earth wire with the sizes4x 10 Sq. mm + 2x6 Sq. mm earth wireof FRLS PVC insulated copper conductor,single core cable in surface /recessed conduit including dismantintling/Removing of burnt cable as required complete all as specified and directed. |
| 65 | Supply and fixing in repair 20 A, 240V, SPN Industrial type socket outlet with 2 pole and earth,metal enclosed plug topalongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commissioning etc.as required complete all as specified and directed. |
| 66 | Supply and fixing in repair LED surface full fit luminaire 2 fit X2 fit (>100 Lumen/Watt) suitable for false ceiling ,white powder coated CRCA housing and high translucent frosted diffuserwith glare free uniform illumination with longer life and less maintenance including all necessary electric connection complete all as specified and directed. |
| 67 | Supply and fix in repairs of driver as per sample for indoor type LED fitting of following watt complete all as specified and directed. |
| 68 | LED driver 10 Watt. |
| 69 | LED driver 18/20 Watt. |
| 70 | LED driver 36/40 Watt suitable for 2x2 false ceiling lights. |
| 71 | Supply and fixing in repair of KWH Meter board only made of sheet metal board made from 2 mm thick CRCA sheet with door and locking arrangementand duly powder coatedsuitable for fixing of 08 Nos for each qtrs and alsofor single phase- 01 No for common area including provision fixing of fixing of mcb TPN /DP as out going from meter,including cutting chasing in wall and fixing and making good as per existing surface complete including removing Oldbox complete all as specified and directed. Note : (i) The cost is for onlyfabricating and fixing at each qtr. (ii) Refixing of old electric meter is included in item rate. (iii) DB\"s shall be measured and paid under relevent item. |
| 72 | Dismantling and taking down ceiling fan any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testingall as specified and directed. |
| 73 | M & L in repair for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height, dismantling ceiling fan motor, removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing newpainting to ceilingfans complete with synthetic enamal Grey paintby spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc, testing, refixing the same in original position complete all as specified and as directed by the Engineer-in-Charge. Note: Rate include the taking down the ceiling fan and deposited to MES store for checkingand repairing) |
| 74 | All as per Item No.70above but for the Exhaust fan of 300 / 450 mm sweep sizes. |
| 75 | M & L for repairing of the earthing complete with digging and filling the saltand charcoal 5-10kg and refiling sand includingchamber plaster, providing the RCC cover of the required size including all neccessary work,testing on completion complete all as specified & directed. |
| 76 | M&L in repair Earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron strip25 X 4mm as earth lead by means of bolts nuts and washers of galvanized iron including excavation and earth workand disposal of surplus soil including 40 mm GI tubing light grade and necessary fittings for protection ofGI strip including laying of charcoal, dust and common salt ,Earth pit shall be in PCC 1:2: 4 type B 1using 20 mm graded aggregate, 40 X 40 X6.0 mm MS angle iron frame, RCC cover 40 mm thick (1:2: 4) Type C0 (using12.50 mm graded stone aggregate) reinforced with 8 mm dia round bar @ 75 mm C/C both way with plastering 15 mm thick CM (1:6) internally and up to 150 mm below ground level externally, PGI funnelwith wire mesh, 20 mm dia medium grade GI pipe for watering complete all as shown on electrical plate No: 03 of SSR part - I 2009 and connected to earth test point including testing on completion and taking out old earthing complete all specified and directed. Note: No JCB excavation permitted. |
| 77 | Taking down old indoor/outdoor units of split type AC of any make/type havingcapacity 1/1.5/2 TR for servicing, cleaning properlywith chemical substance at site with replacing the defective parts as requiredfor OTM accomodation in scattered area ofNPOL Kakkanadu and refixing the same on its original position complete all as specified and directed.Note: Required items will be measured and paid separately. |
| 78 | All as per Item No 74 above but for window type AC of capacity 1.5 / 2.0 Ton complete all as specified and directed. |
| 79 | M&L in repair for water servicing of water cooler ofcapacity 40/80 to 75/150 Ltr including cleaning of water cooler tank after disconnecting the incoming water supplyconnection and re fix the same on its original positionafter cleaning complete all as specified and directed. |
| 80 | Supply and chargein repair of R-32/ R-410refrigerant gasas suitable for existing AC\"s/ Refrigerators and water cooler of any size/make including copper stainer and cappillary tube etc as per site requirement including testing complete all as specified and directed.Note: Nitrogen gas test shall be done prior to the filling and leakage if any shall be arrested. |
| 81 | Supply in repair only Capacitor36/45 MFD suitable for 230 V 50 HZ AC supplycomplete all as specified and directed. |
| 82 | Supplyin repair only Capacitor50/60MFD suitable for 230 V 50 HZ AC supply complete all as specified and directed. |
| 83 | Supply in repair only Capacitor80/100MFD suitable for 230 V 50 HZ AC supplycomplete all as specified and directed. |
| 84 | Taking out existing burnt fan motor single phase 230 Voltfrom the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the followingcomplete all as specified and directed. |
| 85 | Split /window type AC capacity up to 1.5 Ton. |
| 86 | Split/ window type AC 2.0 Ton Capacity. |
| 87 | Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR complete all as specified and directed. |
| 88 | Taking out old unserviceable PCB and replace the same with new PCB at site suitable for Tower AC of capacity 3/4TR (Indoor/ Outdoor) complete all as specified and directed. |
| 89 | Taking out carefully existing defective sealed unit compressor and Supply & fixing in repair factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed. |
| 90 | window type AC capacity up to 1.5/2.0 Ton. |
| 91 | Split type Ac 1.5/2.0 Ton capacity. |
| 92 | Refrigerator capacity of 165/190/240/285/310 ltrs. |
| 93 | water cooler capacity of 40/80, 60/120 & 75/150 ltrs. |
| 94 | M & Lin repair , Sealed compressor unit suitable for 3-4 TR capacity 3 phase ductable split/ Tower AC including first filling of refrigerant gas, compressor oil etc. testing and commissioning, including taking down of old u/s one, complete all as specified and as directed. |
| 95 | M&L in repair for removing the damaged insulation of suction and discharge line & Supply and fixing in repair new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as specified and directed. |
| 96 | M & Lin repair for refrigerent piping for Split type AC 1.5/2.0 TR and Tower AC 3.0/4.0 TR with nitrile rubber insulation between indoor and out door units for split/ Tower Ac units exceeding for 3.0 Mtrs complete all as specified and directed. |
| 97 | M & L in repair for PVC drain pipe upto 25mm for connecting to nearest drain lines including chasing, drilling passing through on wall / Terrace complete all as specified and directed. |
| 98 | Taking out defective thermostat & Supply and fixing in repair new thermostat for refrigerator suitable for capacity of 165 / 286 / 310 Liters complete all as specified and directed. Make: INDFOSS / RANTROL / ANNAPURNA. |
| 99 | Supply only in repair new capacitor of Fan motor of 4 MFD complete all as specified and directed. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. |
| 100 | Supply only in repair new capacitor of Fan motor of 10MFD complete all as specified and directed. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. |
| 101 | Supply only in repair over load protector for window type AC/Split type AC complete all as specified and directed. Make: USHA / ASIAN / TESLA / KELTRON / KEIL. |
| 102 | Suply only in repair split type AC indoor unit oscilation motor complete all as specified and directed. |
| 103 | Supply only in repairthermostat for split/Window type AC 1.0/1.5/2.0 complete all as specified and directed. Make: INDFOSS / RANTROL / ANNAPURN+B100A. |
| 104 | Supply and fix in repair 240V 20 Amp singlepole and earth enclosure with a two pin and earth plug and socket complete with one single poleMCB20 Amp SPcomplete all as specified and directed.Make: Legrand/ L & T/ Indo Asian/ havells |
| 105 | Supply and fix in repair MCB240 V 50 Hz AC 10 KA , of following rating with necessarylugs for incomming and outgong connectionsfixed onDB / Enclosure/ Panel Boards after taking down the existing MCBof any Make/ rating complete all as specified and directed. |
| 106 | MCB SP 20 to 32 Amp. |
| 107 | MCB SPN 32 to 63 Amp. |
| 108 | Taking out existing unserviceable flexible cable of any size & Supply and fixing in repair new copper flexible cable of the following sizes for Water coolers / Window type ACs / Split Acs/ Refrigerator/ Deep freezer etc complete all as specified and directed. |
| 109 | Flexible copper cable, 3 core, 4 Sq.mm. |
| 110 | Flexible copper cable, 3 core, 2.5 Sq.mm. |
| 111 | Material and labour in repair for spray painting, out door unit of1.5 Ton / 2.0 Ton capacity split type A/C by two coat of spray painting using super enamel paint over one coat of anticorrosive primer including preparation of old surfaces by scrapingetc complete all as specified and directed. |
| 112 | Supply & fix in repair of factory made MS bracket (setof two) or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc., all as specified andas directed. |
| 113 | M & L in repair Removing the Window/Split A/C /Tower AC unit from existing position,of capacity1.5/2.0 Ton ofany make and refix the same in other location by fixing the indoor and out door unit in position on fixing on wall/ floor as directed including piping refix the insulation ,Gas charging filling the cavities on wallsetting of grills alignment complete including , testing & commissioning to the entire satisfaction of Engineer-in-Charge complete all as specified and directed.Note:-topping of gas if required, it will be measured & paid under relevant item. |
| 114 | S & Fin repair, starting relay pin type,240V, suitable for Window / Split type AC of any capacity, make or model, complete all as specified and directed. |
| 115 | S&F in repairin repair, PVC float valve assembly 15mm bore suitable for water cooler complete all as specified and directed. |
| 116 | S&F in repairin repair, 15 mm bore, lift cock tap, suitable for water cooler complete all as specified and directed. |
| 117 | M & L in repair, Voltage stabilizer 5 KVA by rewinding/ replacing the main transformer and replaceing PCB, sensing tranformer, power realy, connector pieceand testing on complection complete all as specified and directed. |
| 118 | All as peritem No. 104 here in above, but of 4KVA |
| 119 | M&L in repair of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make complete all as specified and directed. |
| 120 | Repair /replacement of candle for water purifier of suitable size/make for water cooler of capacity 40/80Ltr,60/120Ltr and 75/150Ltr complete all as specified and directed. |
| 121 | Supply and fixing in repair plug top 16 Amp, 230 Volt complete all as specified and directed. |
| 122 | Attending the emergent complaint for any type / any time of cooling applainces such as AC of capacity 1 to 4 TR Both window and split type), water cooler of capacity 40/80, 60/120 and 75/150Ltr and refrigerator of capacity60 to 190 Ltrinstalled at technical area of NPOL Kakkanadu, by providing one mechanic and one helper alongwith required tools complete all as specified and directed. |
| 123 | Taking down the old sub main wiring and M&/Lfor new sub main wiring with 4 run single core 6.0 sq mmPVC unsheathed copper multistranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L-bow, saddles etc of white/ lvory colour PVC conduit including multistranded copper earth conductor 6.0 sqmm two run as earth continuty conductor complete all as specified and directed.Note: 6 runs of conductor cable and 1 pvc conduit shall be measured as one unit length. |
| 124 | Taking down the old sub main wiring and M&Lfor new sub main wiring with 4 run single core 4.0 sq mmPVC unsheathed copper multistranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L-bow, saddles etc of white/ lvory colour PVC conduit including multistranded copper earth conductor 4.0 sq mm two run as earth continuty conductor complete all as specified and directed.Note: 6 runs of conductor cable and 1 pvc conduit shall be measured as one unit length. |
| 125 | S&F in repair in repairs indoor unit blower fan for 1.5 / 2 TR Split AC complete all as specified and directed. |
| 126 | S&F in repair suction copper pipe line heavy duty ½” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and directed. |
| 127 | S&F in repair discharge copper pipe line heavy duty 3/8\"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and directed. |
| 128 | S&F in repair selector switch of window type AC complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail