| 1 | S&F in replacement offirst aid kit box/emergency medical boxwall mouted type made out of powder coated GI sheet of 18 gauge and the size of the box will be 36cm(H) x 26cm(W) x 13 cm(D) with front transparent acrylic glass and multi compartment 4 shelf for better organize of medicines with security lock on door, openable window at front side with help of hinge at one side and locking arrangement at another side, openable window must painted with \"FIRST AID\" with red paint and whole box will fixed on wall at height not less than 2mtr including medicene and other items as under :- (i) Sterilized dressings- 04 Nos, (ii) Cotton Wool 10 gm - 02 Nos, (iii) Antiseptic Solution (100 ml) - 01 No, (iv) Burn Ointment - 01 No, (v) Scissor - 01 No, (vi) Digital Thermometer - 01 No, (vii) Disposal Gloves - 02 Nos, (viii) Disposal Mask - 20 Nos, (ix) Adhesive / Microporous Tape 1/2\" - 01 No, (x) Band- Aid - 10 Nos, (xi) Safety pins - 05 No, (xii) Cold Rub - 01 No, (xiii) Roller Bandage (5cm) - 02 Nos, (xiv) Roller Bandage 10 cm - 02 Nos, (xv) Cotton Buds - 10 Nos, (xvi) Hand Sanitizer - 02 Nos, (xvii) Handiplast - 12 Nos, (xviii) Antiseptic cream - 01 No, (xix) Antiallergic medicene, Cough medicene, Pain killer, Fever and cold medicene- 01 strip each and a First-Aid Guide booklet, complete all as specified and directed. |
| 2 | Uprooting grass/weeds/plants up to 30cm depth by scrapping soil in order to make free ground from all sort of vegetation (grass/weeds/plants) and hand packing carefully by packing round pebbles approximately of size 20 to 40mm after carefully picking form heap of pebbles/stones, complete all as specified and directed. |
| 3 | Cleaning of area around E/M sub division by scraping the grass and creepers from roof and spraying grass killing chemical (as approved by Engr-in-charge) with spray gun, as per manufacturer\"s instructions for prevention of weeds and grass at surrounding of E/M sub station area, complete all as specified and directed. |
| 4 | Supply and spreading unslaked lime at E/M sub station area to destroy the roots of grass and herbs, complete all as specified and directed. |
| 5 | Supply and filling dry river sand at surrounding of E/M installations / sub stations /cable trenches including watering and consolidation, complete all as specified and directed. |
| 6 | Supply and filling crushed stone aggregate, free from any foreign particles, 25mm gradded, for spreading at E/M sub station area, complete all as specified and directed. |
| 7 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars, manholes etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed. |
| 8 | M&L for brick work with sub class \"B\" bricks, old size, burnt clay brick, straight or curved on plan exc 6 mtr mean radius built in CM (1:6), complete all as specified and directed. |
| 9 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:6) and finished even and smooth without using extra cement, complete all as specified and directed. |
| 10 | M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and directed. |
| 11 | M&L for complete removal of existing treatment of old painted steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality), complete all as specified and directed. |
| 12 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level), complete all as specified and directed. |
| 13 | M & L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping/benching/foundation of columns, filling and mass concrete etc, complete al as specified and directed. |
| 14 | M&L 75mm thick PCC (1:3:6 ) type C-2, (using 40mm graded stone aggregate) for sub base of floor, plinth prtection, path/hard standing etc, complete all as specified and directed. |
| 15 | Supply and installation information display board of size 100cm x 130cm at E/M installations to display the maintenance chart/shock treatment/Do\"s and Dont\"s/fire fighting/first aid/circuit diagram etc, the border of the board made out of 2nd class hard wood bead width n. exc. 25cm of thickness 30mm including varnishing display area of board made of 1st class hard wood 25mm thick hard wood including soft material for pinning of information on board including covered with green velvate cover (not less than Rs. 400 /- per Sqm) and complete board should be covered with talcum sheet, transparent type, and charts are pined on the board with spikes including taking down old unserviceable board of any size, complete all as specified and directed. |
| 16 | Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in deep for foundation etc. or for cable/CI/PP-R/GI pipe, shaft, wells, cesspits, manhole, pair house etc.and getting out in soft/loose soil, complete all as specified and directed. |
| 17 | Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. |
| 18 | Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed. |
| 19 | M & L for road cutting/removing the hard standing/cutting plinth protection of building/path for laying of pipe line of any size including making good disturbed surfaces after laying of cable, as per existing, complete all as specified and directed. |
| 20 | M & L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) for making good to disturbed surfaces of road/hardstanding etc, complete all as specified and directed. |
| 21 | Supply and laying or fixing,three layer (inner antimicrobial & outer UV stabilized), polyprolene random pipe 90mm outer dia, PP-R pipes SDR 7.4 (PN-16) confirming to IS -15801 : 2008 UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including PP-R plain & brass threaded polypropylene random fittings fixed complete to trenches/wall/cellings or laying in floor including taking down old unserviceable PP-R/GI pipes, complete all as specified and directed. |
| 22 | All as per item No 21.00 here-in-before but 75mm outer dia, complete as specified and directed. |
| 23 | All as per item No 21.00 here-in-before but 63mm outer dia, complete as specified and directed. |
| 24 | All as per item No 21.00 here-in-before but 50mm outer dia, complete as specified and directed. |
| 25 | All as per item No 21.00 here-in-before but 32mm outer dia, complete as specified and directed. |
| 26 | M&L for 100mm bore, ductile iron pipe (K-7), socket and spigot end as per IS:8329 with internal cement mortar lining and external bitumen coating for potable water supply with and including rubber ring joints as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per technical specification etc laid in trenches including taking out/down old unserviceable pipe any type, complete all as specified and directed.(Note: Excavation and earth work shall be measured and paid separately under respective items) |
| 27 | All as per item No 26.00 here-in-before but 150mm bore, complete as specified and directed. |
| 28 | S&F CPVC pipe of size 75mm inner dia in trenches, high pressure, CPVC pipes, schedule 40 & plain CPVC schedule 80 fittings, including all necessary fittings, like elbow, tee, socket, reducer, bushings, step over bends, end caps, end plugs, etc. and with CPVC solvents cement including taking down old unserviceable pipes, complete all as specified and directed. |
| 29 | S&F 50mm bore GI water tubing and connection, medium grade, with all fitting fixed to wall or in ceiling or laid in floors including taking down old unserviceable pipe, complete all as specified and directed. |
| 30 | S&F 25mm bore GI water tubing and connection, medium grade, with all fitting fixed to wall or in ceiling or laid in floors including taking down old unserviceable pipe, complete all as specified and directed. |
| 31 | S&F in repair three layer PP-R elbow 90/45 degree (UV stabilized) confirming to IS -15801 : 2008, for 90mm dia PP-R pipes, complete all as specified and directed. |
| 32 | S&F in repair three layer PP-R elbow 90/45 degree (UV stabilized) confirming to IS -15801 : 2008, for 63mm dia PP-R pipes, complete all as specified and directed. |
| 33 | S&F in repair three layer PP-R union 90mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes, complete all as specified and directed. |
| 34 | S&F in repair three layer PP-R union 63mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes, complete all as specified and directed. |
| 35 | S&F in repair three layer PP-R socket 90mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes, complete all as specified and directed. |
| 36 | S&F in repair three layer PP-R socket 63mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes, complete all as specified and directed. |
| 37 | S&F in repair three layer PP-R FT 90mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes, complete all as specified and directed. |
| 38 | S&F in repair three layer PP-R FT 63mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes, complete all as specified and directed. |
| 39 | S&F in repair three layer PP-R MT 90mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes, complete all as specified and directed. |
| 40 | S&F in repair three layer PP-R MT 63mm dia (UV stabilized) confirming to IS -15801 : 2008, for PP-R pipes, complete all as specified and directed. |
| 41 | S&F in repair three layer PP-R flange (core), 90mm dia (UV stabilized) confirming to IS -15801 : 2008 for PP-R pipes, complete all as specified and directed. |
| 42 | S&F in repair three layer PP-R flange ring, 75mm dia (UV stabilized) confirming to IS -15801 : 2008 for PP-R pipes, complete all as specified and directed. |
| 43 | S&F 150mm dia CI sluice valve, flanged end, class PN 1.6 (IS-14846) with brass spindle and hand wheel including necessary gasket, nuts and bolts, washer etc. including taking down old unserviceable sluice valve, complete all as specified and directed. |
| 44 | S&F 100mm dia CI sluice valve, flanged end, class PN 1.6 (IS-14846) with brass spindle and hand wheel including necessary gasket, nuts and bolts, washer etc. including taking down old unserviceable sluice valve, complete all as specified and directed. |
| 45 | S&F 80mm dia CI sluice valve, flanged end, class PN 1.6 (IS-14846) with brass spindle and hand wheel including necessary gasket, nuts and bolts, washer etc. including taking down old unserviceable sluice valve, complete all as specified and directed. |
| 46 | M & L for cutting existing steel tubing of size40/50mm for alterations or additions (each cut measured), complete all as specified and directed. |
| 47 | M & L for screwing existing steel tubing of size 40/ 50mm for alterations or additions (or lengthening screw on pipe to form connector), complete all as specified and directed. |
| 48 | S&F in repair 32mm dia PP-R gate valve (brass insert) confirming to IS -15801 : 2008, complete all as specified and directed. |
| 49 | S&F in repair 50mm dia PP-R gate valve (brass insert) confirming to IS -15801 : 2008, complete all as specified and directed. |
| 50 | S&F in repair 63mm dia PP-R gate valve (brass insert) confirming to IS -15801 : 2008, complete all as specified and directed. |
| 51 | S&F 50mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unserviceable valves, complete all as specified and directed. |
| 52 | S&F 40mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unserviceable valves, complete all as specified and directed. |
| 53 | S&F 25mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unserviceable valves, complete all as specified and directed. |
| 54 | S&F 20mm bore gun metal gate/globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe and taking down old unserviceable valves, complete all as specified and directed. |
| 55 | S&F in repair 50mm dia CPVC ball valve suitable for CPVC pipe, complete all as specified and directed. |
| 56 | S&F in repair 40mm dia CPVC ball valve suitable for CPVC pipe, complete all as specified and directed. |
| 57 | S&F in repair 25mm dia CPVC ball valve suitable for CPVC pipe, complete all as specified and directed. |
| 58 | S&F rotational moulded polyethylene water storage tanks, triple layered, (cylindrical vertical with closed top) ISI marked, confirming to IS 12701-1989, hoisted and fixed in position all as specified in SSR Part I (500 ltr capacity) including 20mm Nipple suitable for HDPE water tank and ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed to 20mm bore pipe inculding dismantling of old unserviceable water tank, complete all as specified and directed |
| 59 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint complete for base support frame for water tanks at roof top/ground floor including dismantling of old unserviceable cross arm/bracings etc, complete all as specified and directed. |
| 60 | Taking up or down steel tubing and connections, from walls, ceiling, floors etc, of size 20/25mm bore cleaning including refixing and connections in new or old position, complete all as specified and directed. |
| 61 | M & L for run lead joints in position for cast iron spigot and socket ends pipes of size 150mm bore including providing new spun yarn jute etc, as required, complete all as specified and directed. |
| 62 | M & L for run lead joints in position for cast iron spigot and socket ends pipes of size 100mm bore including providing new spun yarn jute etc, as required, complete all as specified and directed. |
| 63 | M & L for run lead joints in position for cast iron spigot and socket ends pipes of size 80mm bore including providing new spun yarn jute etc, as required, complete all as specified and directed. |
| 64 | M & L forDI fitting upto 200mm bore for bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (flange sockets or socket and spigot) collars, caps and plugs, complete all as specified and directed. |
| 65 | M & L for CI Fitting upto 200mm bore for bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (flange sockets or socket and spigot) collars, caps and plugs, complete all as specified and directed. |
| 66 | Attending pipeline breakdown of CI/DI/GI pipe of 80/100/150/200mm dia by making lead joint with lead and spun yarn and moulding clay including takin up/down pipe using chain pulley or rope and excavation in any type of soil including returning filling and removal of soil and testing of pipe line, complete all as specified and directed.Note : Lead joint /titon joint/material/fitting/pipeline shall be measured and paid seperately. |
| 67 | Boring of holes under road, pavement, hard standing by using trenchless technology, using ultra sounding technique and necessary machine including providing (DWC) HDPE pipe of 150mm outer dia, not less than 1.0m below GL, complete all as specified and directed. |
| 68 | M & L for construction of valves pit chamber of size (1200mm x 1200mm x 1200mm, internal), 15cm thick PCC foundation using PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate), 25cm thick brick wall, using old size burnt clay brick in CM (1:4), 10mm thick rendering on internal and extranal surfaces both in CM (1:4), PCC (1:2:4) type B1 coping (using 20mm graded crushed stone aggregate) for grouting MS frame including foundation 3mm thick MS top sheet cover with locking arrangement including 50mm pad lock with double key arrangement, MS frame work made out of 40 x 40 x 5mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer incuding necessary excavation in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtrs including demolition of existing cracked valve chamber, complete all as specified and directed. |
| 69 | All as per item No 68.00 here-in-before but of size (900mm x 900mm x 900mm, internal), complete as specified and directed. |
| 70 | Note: An amount of Rs.82,274.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| 71 | Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips |