| 1 | Takingdown carefully old point wiring (light, fan, socket, bell point orpower point) completeincludingunserviceablefixtures like switchessockets, holders, ceilingroses etc removing from site and keeping in safe custody for taking credit and making good disturbed surfaces of wall /ceiling withcement plasterin cement mortar(1:6) and distempering / white washing to match the existing surface complete all as specified & directed. |
| 2 | Taking down old unserviceable Empty Box / Bus Bar Chamber / DB’s of any capacity with MCCB\"s or MCB fixed on wall and making good disturbed surfaces of wall / floor with cement plaster in cement mortar (1:6) and distempering / white washing to match the existing surface complete all as specified & directed. |
| 3 | M&L for point wiring with two single core PVCinsulatedunsheathed multistranded copperconductor cable (FRLSH) of size 1.5 Sqmm 1100 voltsgradewith onesinglecore PVCinsulatedunsheathedmultistranded coppercable (FRLSH) of size 1.5Sqmm 1100 volts gradeas earth continuity conductor (as per colour code), drawn throughin andincludingPVC surface conduit (medium grade) of 20mm/ 25mm withall accessories such as bend, elbow, tee etc in anytypeof brick wall/ ceiling, plastering and making gooddisturbed surfaces as per existing and connectedto commonearth dolly, sunk type metal box for housing / mounting the modular switch sockets with mounting plate / cover plate complete all as specified and directed for the following items :-Make : PVC Cable-MESCAB/ KEI / RR Kable PVC Conduit/ Casing Caping-Precission /Prestoplast |
| 4 | One light point controlled by one no one way 6 Amps switch complete. |
| 5 | One fan point controlled by one no one way 6 Amps switch complete. |
| 6 | One calling bell point controlled by one no 5 Amps bell push switch complete. |
| 7 | One 6 Amps socket outlet point on the same board with other switches complete |
| 8 | One 6 Amps switch socket combination point on independent board complete |
| 9 | All as per Serial item No.3.00 here-in-before butwith two single core PVCinsulated unsheathedmultistranded copper conductor cable (FRLSH) of size 4.0 Sq1100 volts grade and one single core PVC insulated unsheathed multistrandedcopper conductor (FRLSH) of size 4.0 Sqmm 1100 Volts grade as earth continuity conductor (as per colour code) includingPVC surface conduit (medium grade) of size 20mm/ 25mm withall accessories such as bend, elbow, tee etc for 15 Amps switchsocket combination pointon independentboard complete all as specified anddirected. |
| 10 | S&F Metal flush Box 1/2 Module, complete all as specified and directed by Engr-in-charge |
| 11 | S&F Metal flush Box 3 Module, complete all as specified and directed by Engr-in-charge |
| 12 | S&F Modular Plate 4 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 13 | S&F Metal flush Box 6 Module, complete all as specified and directed by Engr-in-charge |
| 14 | S&F Metal flush Box 8 Module, complete all as specified and directed by Engr-in-charge |
| 15 | S&F Metal flush Box 12 Module, complete all as specified and directed by Engr-in-charge |
| 16 | S&F Modular Plate 2 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 17 | S&F Modular Plate 3 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 18 | S&F Modular Plate 6 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 19 | S&F Modular Plate 8 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 20 | S&F Modular Plate 12 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 21 | S&F modular switch single pole one way, 6 Amp, AC,230 V all as specified and directed.Make : Anchor/ Indo-asian/ Legrand |
| 22 | S&Fmodular bell push, 6 Amp, AC,230 V all as specified and directed. Make : Anchor/ Indo-asian/ Legrand |
| 23 | S&Fmodular switch single pole one way, 16 Amp, AC,230 V all as specified and directed.Make : Anchor/ Indo-asian/ Legrand |
| 24 | S&F modular socket 6A, AC, 230V complete all as specified and directed.Make : Anchor/ Indo-asian/ Legrand |
| 25 | S&F modular socket 6 /16 Amp, AC, 230V complete all as specified and directed.Make : Anchor/ Indo-asian/ Legrand |
| 26 | S&F rotary step modular electronic fan regulator (2 module) flush typeAC, 230V, 120 Wcomplete all as specified & directed. Make : Anchor/ Indo-asian/ Legrand |
| 27 | M&L for point wiring with two single core PVCinsulatedunsheathed multistranded copperconductor cable (FRLSH) of size 1.5 Sqmm 1100 voltsgradewith onesinglecore PVCinsulatedunsheathedmultistranded copper cable (FRLSH) of size 1.5 Sqmm 1100 volts gradeas earth continuity conductor (as per colour code), drawn throughin andincludingPVC casing caping of size 20/25 mm, medium gradewithall accessories such as bend, elbow, tee etc. in anytypewall/ ceiling, plastering and making gooddisturbed surfaces as per existing and connectedto commonearth dolly, switch board or box plastic or PVC typefor housing / mounting the switch sockets etc complete all as specified and directed for the following items :- |
| 28 | One light point controlled by one no one way 6 Amps switch complete. |
| 29 | One fan point controlled by one no one way 6 Amps switch complete. |
| 30 | One calling bell point controlled by one no 5 Amps bell push switch complete. |
| 31 | One 6 Amps socket outlet point on the same board with other switches complete |
| 32 | One 6 Amps switch socket combination point on independent board complete |
| 33 | All as per Serial item No.22.00 here-in-before but with two single core PVCinsulated unsheathedmultistranded copper conductor cable (Heat Resistant Flame Retardant) of size 4.0 Sq1100 volts grade and one single core PVC insulated unsheathed multistrandedcopper conductor (Heat Resistant Flame Retardant) of size 4.0 Sqmm 1100 Volts grade as earth continuity conductor (as per colour code) includingPVC Casing Caping20/25 mm diafor 15 Amps switch socket combination pointon independentboard complete all as specified anddirected. |
| 34 | S&F ceiling Rose, surface, bakelite 65 x50 mm three terminals (ISI Marked), AC, 230 Volts complete all as specified & directed. Make : Anchor / Havells Reo / Maru |
| 35 | S&F switch piano flush type single pole one way (ISI Marked), 6 Amp, AC,230 V all as specified and directed. Make : Anchor (Code-38014) / Havells Reo / Maru |
| 36 | S&Fbell push flush type (ISI Marked), 6 Amp, AC,230 V all as specified and directed. Make : Anchor / Havells Reo / Maru |
| 37 | S&F socket outlet flush type 2 in 1, 6A, AC, 230V complete all as specified and directed. Make : Anchor / Havells Reo / Maru |
| 38 | S&F switch & socket combination flush type 2 in 1, 6A, AC, 230V complete all as specified and directed. Make : Anchor / Havells Reo / Maru |
| 39 | S&Fswitch socket combination flush type 2 in 1,6 Pin, 20/10 Amp, AC, 230V with four fixing holes complete all as specified and directed. Make : Anchor / Havells Reo / Maru |
| 40 | S&F rotary step deluxe electronic fan regulator flush type 2 module, 100 W, 230 V AC complete all as specified and directed. Make : Anchor / Havells Reo / Maru |
| 41 | S&F Calling Bell Ding Dong Type AC, 230Vcomplete all as specified and directed. Make : Anchor /Cona |
| 42 | S&F Batten/Angle Lamp holder, PVC/ Polycarbonate type with back platefor fixing on the wall complete all as specified and directed.Make : Anchor (Code-39527/ 38538) / Havells Reo |
| 43 | Supply and fixinglight opal glass marble with chrome finish luminaires with LED lamp E27 LED 7WX1 complete all as specified and directed.Make : Jaquar (Item Code DWL-CHR-MB160275211A)/ Havells/ Century LED Pvt Ltd. or equivalent as per make approved by MES |
| 44 | S&F decorative, wall mounting, brushed nickel finish fixture with opal glass diffuser suitable for LED lamp 9W-B22 on the wall by stainless steel screw, rawl plug etc complete all as specified and directed.Make : Havells (Code LHFOAJE1TZ1I060/ Jaquar/ Century LED Pvt Ltd. or equivalent as per make approved by MES |
| 45 | Supply of surface mounted batten type, slim LED luminaires 10 W, 220 - 240 V AC, 50 Hz, IP 20 with aluminium extruded housing, polycarbonate diffuser & end caps,minimum efficacy 100 lumens/watt with 120 degree viewing angle, CCT 6500, CRI ≥ 80, power factor ≥0.9, IP 20, surge protection 4.0 KV, THD < 20% integral electronic driver with short circuit protection and open circuitprotection, surge voltage protection completeall as specified and directed. Make : Havells (Type- LUMILINE NXT BATTEN)/ Philips/ Jaquar (Type- Glaze) or equivalent as per make approved by MES. |
| 46 | Supply of surface mounted batten type, slim LED luminaires 20 W, 220 - 240 V AC, 50 Hz, IP 20 with aluminium extruded housing, polycarbonate diffuser & end caps,minimum efficacy 100 lumens/watt with 120 degree viewing angle, CCT 6500, CRI ≥ 80, power factor ≥0.9, IP 20, surge protection 4.0 KV, THD < 20% integral electronic driver with short circuit protection and open circuitprotection, surge voltage protection completeall as specified and directed. Make : Havells (Type- LUMILINE NXT BATTEN)/ Philips/ Jaquar (Type- Glaze) or equivalent as per make approved by MES. |
| 47 | Supply of surface mounted batten type, slim LED luminaires Rod20 W, 220 - 240 V AC, 50 Hz, IP 20 with aluminium extruded housing, polycarbonate diffuser & end caps,minimum efficacy 100 lumens/watt with 120 degree viewing angle, CCT 6500, CRI ≥ 80, power factor ≥0.9, IP 20, surge protection 4.0 KV, THD < 20% integral electronic driver with short circuit protection and open circuitprotection, surge voltage protection completeall as specified and directed. Make : Havells (Type- LUMILINE NXT BATTEN)/ Philips/ Jaquar (Type- Glaze) or equivalent as per make approved by MES. |
| 48 | Fixing of surface mounted batten type LED luminaires (10 or 20 W, 230V AC) (as mentioned in Sl No. 35.00,36.00 & 37.00) on the wall by stainless steel screw, rawl plug etc. & connecting up to ceiling rose with three core sheathed copper conductor cable (white/ gray colour) of suitable sizes complete including taking down old unsv one all as specified and directed. |
| 49 | Supply of high efficacy recess mounted LED luminaires 36W, 240V AC, 2X2 tile in CRCA housing with full opal diffuser with flicker control technology to reduce harmful invisible flicker present in LED lighting sources, CCT 6500K, CRI ≥ 80, rated voltage 240V AC, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuitprotection, surge voltage protection complete all as specified and directed. Make : Orient (CAT LTRAQ-36-C-FC)/ Philips/ Havells or equivalent as per make approved by MES. |
| 50 | Supply of Surface mounted LED luminaires 18 W, 220-240V AC, minimum size 300 mmX300 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuitprotection, surge voltage protection complete all as specified and directed. Make :Havells (PLUTO1X1PLS18WLED840SG2)/ Orient/ Phillips or equivalent as per make approved by MES. |
| 51 | Supply of recess mounted LED luminaires 15 W, 220-240V AC, minimum size 295 mmX295 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuitprotection, surge voltage protection complete all as specified and directed. Make : Havells (PLUTO1X1PLR15WLED857SG2)/ Orient/ Phillips |
| 52 | Supply of recess mounted LED luminaires 18 W, 220-240V AC, minimum size 206 mmX206 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuitprotection, surge voltage protection complete all as specified and directed. Make : Jaquar (LNEP01S018XC or LNEP01S018XN) Havells/ Orient/Phillips or equivalent as per make approved by MES. |
| 53 | Supply of recess mounted LED luminaires 15 W, 220-240V AC, minimum size 180 mmX180 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuitprotection, surge voltage protection complete all as specified and directed. Make : Orient/ Philips/ Havells / Jaquar LNEP01S012XC or LNEP01S012XN or equivalent as per make approved by MES. |
| 54 | Supply of recess mounted LED luminaires 12 W, 220-240V AC, minimum size 160 mmX160 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuitprotection, surge voltage protection complete all as specified and directed. Make : Orient/ Philips/Havells (VIBETRENDSQDLR12WLED840S) or equivalent as per make approved by MES. |
| 55 | Supply of recess mounted LED luminaires 6 W, 220-240V AC, minimum size 107 mmX107 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuitprotection, surge voltage protection complete all as specified and directed. Make : Havells (VIBETRENDSQDLR6WLED840S)/ Orient/ Havells or equivalent as per make approved by MES. |
| 56 | Supply of recess mounted LED luminaires 6 W, 220-240V AC, minimum size 72 mmX72 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuitprotection, surge voltage protection complete all as specified and directed. Make : Havells (VIBETRENDSQDLR6WLED865S)/Orient/ Jaquar or equivalent as per make approved by MES. |
| 57 | Supply of industrial bulkhead LED luminaires 10 W, 240V AC with aluminium die cast housing and vandal-resistant cover finished in epoxy powder-coated housing with diffuser, power factor ≥0.9, IP 65, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuitprotection, surge voltage protection complete all as specified and directed. Make :Havells (RUGBYGENXFTS10WLED865SSYMBOPC) / Jaquar / Phillips or equivalent as per make approved by MES. |
| 58 | Fixing of recess or surface mounted type LED luminaires (3 to 36W, 230V AC) (as mentioned in sl 39.00 to 47.00) on the wall, roof, false ceiling by stainless steel screw, rawl plug etc. & connecting up to ceiling rose with three core sheathed copper conductor cable (white/ gray colour) of suitable sizes complete incl taking down old unsv one all as specified and directed. |
| 59 | M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade and onerun of PVCinsulated unsheathed multistranded copper conductorcable (FRLSH) of size4.0Sqmm 1100 volts grade as earthcontinuity conductor (as per colour code) drawn through in and including DLP mini trunking of size 32X12.5mm with all finishing accessories and junction elements etc. in anytypewall/ ceiling (fixing on wall through rawl plug & stainless steel screw) plastering and making gooddisturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed. Make : PVC Cable-RR Kable/ Finolex/ Havells DLP mini trunking-Legrand |
| 60 | M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade and onerun of PVCinsulated unsheathed multistranded copper conductorcable (FRLSH) of size6.0Sqmm 1100 volts grade as earthcontinuity conductor (as per colour code) drawn through in and including DLP mini trunking of size 32X12.5mm with all finishing accessories and junction elements etc. in anytypewall/ ceiling (fixing on wall through rawl plug & stainless steel screw) plastering and making gooddisturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed. Make : PVC Cable-RR Kable/ Finolex/ Havells DLP mini trunking-Legrand |
| 61 | M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade and onerun of PVCinsulated unsheathed multistranded copper conductorcable (FRLSH) of size4.0Sqmm 1100 volts grade as earthcontinuity conductor (as per colour code) drawn through in and including PVC concealed conduit (medium grade) of size 25 mmwithall accessories such as bend, elbow, tee etcand making groovesin anytypeof brick wall/ ceiling, plastering and making gooddisturbed surfaces as per existing and completeincl. taking down old one all as specified & directed. Make : PVC Cable-Polycab/KEI/ Finolex/ Havells PVC Conduit/ Casing Caping-Precission/ Prestoplast |
| 62 | M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade and onerun of PVCinsulated unsheathed multistranded copper conductorcable (FRLSH) of size6.0Sqmm 1100 volts grade as earthcontinuity conductor (as per colour code) drawn through in and including PVC concealed conduit (medium grade) of size 25 mmwithall accessories such as bend, elbow, tee etcand making groovesin anytypeof brick wall/ ceiling, plastering and making gooddisturbed surfaces as per existing and completeincl. taking down old one all as specified & directed. Make : PVC Cable-Polycab/ KEI/ Finolex/ Havells PVC Conduit/ Casing Caping-Precission/ Prestoplast |
| 63 | S&F sheet metal enclosure for DB’s TPN Double Door 8 way, AC, 415 volt, IP 43 on the wall with MCCB, 160A, 4 Pole of breaking capacity 16kA as incomer complete by masonry works/ cement plaster in cement mortar (1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed. Make : ABB/ Legrand/ Siemens |
| 64 | S&F sheet metal enclosure for DB’s TPN Double Door 4 way, AC, 415 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar (1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed. Make : ABB/ Legrand/ Siemens |
| 65 | S&F sheet metal enclosure for DB’s Vertical-TPN Double Door 12 way, AC, 415 volt, IP 43 on the wall with MCCB, 125A, 4Pole of breaking capacity 25kA as incomer by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface including connection of cable, testing checking etc complete all as specified & directed. Make : ABB/ Legrand/ Siemens |
| 66 | S&F sheet metal enclosure for DB’s Vertical-TPN Double Door 8 way, AC, 415 volt, IP 54 on the wall with MCCB, 125 A, 4Pole of breaking capacity 25kA as incomer by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface including connection of cable, testing checking etc complete all as specified & directed. Make : ABB/ Legrand/ Siemens |
| 67 | S&F sheet metal enclosure for DB’s SPN Double Door 12 way, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed. Make : ABB/ Legrand/ Siemens |
| 68 | S&F sheet metal enclosure for DB’s SPN Double Door 8 way, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.Make : ABB/ Legrand/ Siemens |
| 69 | S&F sheet metal enclosure for DB’s SPN Double Door 4 way, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.Make : ABB/ Legrand/ Siemens |
| 70 | S&F sheet metal enclosure for DB’s for Plug & Socket, SP, AC, 240 volt with MCB SP 16 A on the wall complete by cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.Make : ABB/ Legrand/ Siemens |
| 71 | S&F MCBTPN 40 to 63Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified & directed. Type ‘C’ CharacteristicMake : ABB/ Legrand/ Siemens |
| 72 | S&F MCCB, 4P, 100 -125 Amps, 415 Volts 50 HZ, 36 KA, Ics= 50% Icu incl. connection of cable testing, checking etc complete all as specified & directed. Type ‘C’ CharacteristicMake : ABB/ Legrand/ Siemens |
| 73 | S&F MCBSP 6 to 20Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified & directed. Type ‘C’ CharacteristicMake : ABB/ Legrand/ Siemens |
| 74 | Refixing of MCBSP 6 to 20Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified & directed. |
| 75 | S&F MCB SPN 20 to 32 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as specified & directed.Type ‘C’ Characteristic Make : ABB/ Legrand/ Siemens |
| 76 | Supply only self adhesive PVC electrical insulation tape (1.8cmX6.5mX0.125mm) conforms to IS:7809 (Part-3). Make-Steelgrip/ Anchor |
| 77 | Material and labour for flame proof point wiring on wall and surface wiring on ceiling/ roof with necessary fixing arrangements for one light/ fan point controlled by one switch with stranded PVC, FRLS insulated and unsheathed copper stranded conductor of size 1.5 sqmm, 1100 volts grade drawn in and including 14 gauge ERW rigid steel conduit (metallic) not less than 20 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc. including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 sqmm, 1100 volts grade for continuous earthing complete all as directed. |
| 78 | All as per Serial item No. 67.00 here in above but with 4.0Sqmm for one 15 Amps socket outlet on independent board and 4.0 sqmm PVC insulated multisranded copper conductor cable as continuous earth wire complete. |
| 79 | Supply and fix in repair flame proof rotary switch in ML6, 10/16 amps, single pole, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit duly approved by CMRI dhanbad and as manufacturers intructions including taking down old flame proof rotary switch with enclosure complete all as directed. |
| 80 | Supply and fix in repair Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit duly approved by CMRI dhanbad and as manufacturers intructions including taking down old flame proof rotary switch with enclosure complete all as directed. |
| 81 | Material and labour for sub main wiring on wall and surface wiring on ceiling/ roof with necessary fixing arrangements with two run of single core 4 sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable, including ERWrigid metallic steel conduit medium grade, ISI marked, 20 mm dia for sub main wiring including one run of single core 4 sqmm multi stranded copper conductor FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/ recess and fittings such as junction boxes, bends, tee, elbow etc. complete all as specified. (For light points) |
| 82 | Supply only as in replacement of fan capacitor of capacity 2.25/2.5 mfd, oil filled, metal body, rated voltage 440 volts complete all as specified and as directed. |
| 83 | All as per Serial item No. 72.00 here-in-before but 3.15 mfd. |
| 84 | All as per Serial item No. 72.00 here-in-before but 4 mfd. |
| 85 | M & L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means ofbolt, nut, check nut and washer of galavanised iron steel wire 4mm as earthing lead as shown in Electrical Plate No 4 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 typeC1 using 20mm stone aggreate, funnel, 20mm dia GI med grade water pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs,wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electricalplate no-4 of SSR part No1 all as directed. |
| 86 | Earthing complete with copper earth plate electrode 600x600x3.15mm thick buried directly in ground (earth pit not less than 2.25 m depth below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper strip 20x3mm mm dia by means of brass nut, bolt, washer& protection pipe for earth lead from the earthing plate to the DB/ main switch/ Panel, (25 mm bore, Light grade), watering pipe from plate to earthing pit (20 mm bore, medium grade), funnel with wiremesh. The earthing pit made up of PCC 1:3:6 type CI and pit cover made up of 40 mm thick pre cast RCC 1:2:4 type BI reinforced with 6 mm dia TMT rod and suitable handle of 8 mm dia TMT rod incl necessary earth work as shown in SSR Part 1 plate No.5 as specified & directed. |
| 87 | Note : i) The copper strip and protection pipe beyond 7.5 m length shall be measured and paid separately. However, earthwork and PCC work for the same is deemed to be included in this rate. ii) The desired value of earth resistanceshould be less than 2 Ω , on testing after completion if the desired earth resistance is not obtained; the earthing will be redone at no extra cost, otherwise it will not be measured and paid tothe contractor. iii) Form work of size 0.9m X0.9m X 0.6m for pouring charcoal & salt is deemed to be included in this ratev) During earth work if surface water found at site, the cost for dewatering through pumpset is deemed to be included in this rate. |
| 88 | Supply and fixing LED light fitting 1x20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.Make : Jaquar / Havells/ Phillips or equivalent as per make approved by MES. |
| 89 | S&F for installation of high efficiency 120 W LED Highbay luminaires, IP 66 in aluminium pressure die-cast housing for better heat dissipation with efficacy 150 Lumen/ Watt, CCT 5700K, CRI>70, power factor > 0.95, LED module with SMD LED package; mounted with PC lens to ensure better uniformity of light distribution with surge protector 10 KV including taking down old unsv one complete all as specified and directed.Crompton LNB-11-120-CDL/60HPM,Orient LHPNP-120-C/ Havells SAUCER GENXPROHBP120W LED 757P60DBOLTG/ Philips BY415P LED145S CW HE NB FG PSU GR XTFCL S5150 W LED/ Jaquar LHBLDUL120XC Note : i) Any fastener bolt, steel clamp, nut & bolt reqd for installation of luminaires on the ceiling, steel structure, PCC Foundation etc are deemed to be included in the rate quoted. ii) Any connector reqd for connection of wiring cable to fittings are deemed to be included in the rate quoted. |