Providing, Supplying and erecting electrical and allied parts for operation and maintenance of street light and Providing, Supplying and erecting electrical poles of various specification and allied works within Ichalkaranji city as per direction of Ichalkaranji Municipal Corporation- 1 Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 2 Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 3 Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on providedfoundation as per specification no. OH-PL/OPL 4 Providing & erecting 10 m high (clear height) galvanised octagonal pole withfoundation bolts having bottom of 175 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 5 Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specificationno. OH-PL/BKT 6 Providing and erecting galvanised 1000mm DOUBLE arm sword type bracket withFRP dome and ball as per specification no. OH-PL/PBKT 7 Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole). 8 Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole). 9 Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 10 Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 11 Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP 12 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 13 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 14 Supplying and laying (including excavation of suitable width & depth up to 90cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 15 Dismantling the existing pole above 6 m height with brackets, clamps,insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. 16 Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having systemlumens output of Min. 7700 Lumens, min. fficacy of 110 lumen/W, CRI>70, CCT upto 500K,THD<10%, p.f.>0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warrantyas per specification No. FG-ODF/SL. 17 Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/SL. 18 Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 13000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including drivercomplete with minium 2 Years warranty as per specification No. FG-ODF/SL. 19 Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FG ODF/FL. 20 Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm.stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). 21 Supplying & laying (including excavation) reinforced cement concrete pipe of NP-2 class of 150 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 22 Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 23 Supplying and erecting electronic type Driver for Outdoor LED fittings upto25W suitable to operate on 230V A.C. 50 Hz. Having p.f>0.95 and THD<10% asper specification no. FG-ODF/AS. 24 Supplying and erecting electronic type Driver for Outdoor LED fittings upto26W-45W suitable to operate on 230V A.C. 50 Hz. having p.f>0.95 andTHD<10% as per specification no. FG-ODF/AS. 25 Supplying and erecting electronic type Driver for Outdoor LED fittings upto46W-75W suitable to operate on 230V A.C. 50 Hz. having p.f>0.95 andTHD<10% as per specification no. FG-ODF/AS. 26 Supplying and erecting electronic type Driver for Outdoor LED fittings upto76W-100W suitable to operate on 230V A.C. 50 Hz. having p.f>0.95 andTHD<10% as per specification no. FG-ODF/AS. 27 Supplying, erecting & terminating FR XLPE insulated, galvanised steel wirearmoured (round) cable, 1100 V 2 core 4 sq. mm. aluminium conductorcomplete erected with glands & lugs on wall/ trusses/pole or laid in providedtrench/ pipeas per specification no. CB-LT/AL 28 Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 29 Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 30 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 31 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 32 Re-erecting PVC / XLPE armoured cable 2 to 4 Core up to 50 sq. mm. on wallwith necessary material & G.I. earth wire. 33 Supplying and erecting mains with WP 2 x 2.5 sq. mm. 1.1kV grade aluminiumPVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWGcomplete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 34 Supplying and erecting mains with WP 2 x 4 sq. mm. 1.1 kV grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 35 Supplying and erecting mains with WP 4 x 4 sq. mm. 1.1kV. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 36 Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 37 Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW 38 Supplying and erecting PVC insulated PVC round sheathed FR 1 sq.mm (32 no.x 0.20mm dia.) 3 core flexible multi stranded copper industrial cable for voltagegrade up to 1.1 kV 39 Supplying and erecting PVC insulated PVC round sheathed FR 1.5 sq.mm (30 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable forvoltage grade up to 1.1 kV 40 Supplying,erecting&markingSPMCB6Ato32A,C-serieswithratedshort-circuitbreakingcapacity(Icn)10kA inprovided distributionboardasper specificationno. SW-MCB 41 Supplying,erecting&markingSPMCB6Ato32A,B-serieswithratedshort-circuit breakingcapacity(Icn) 10kA inprovided distributionboardasper specificationno. SW-MCB 42 Supplying, erecting&markingSPMCB40Ato63A,C-serieswith ratedshort circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-MCB 43 Supplying, erecting&markingSPMCB40Ato63A,B-serieswith ratedshort circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-MCB 44 Supplying,erecting&markingDPMCB6Ato32A,C-serieswithratedshort-circuitbreakingcapacity(Icn) 10kAinprovideddistributionboardasper specificationno. SW-MCB 45 Supplying, erecting & marking DPMCB 6A to 32A, B-serieswithratedshort circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-MCB 46 Supplying, erecting&markingDPMCB40Ato63A,C-serieswith ratedshort circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-MCB 47 Supplying, erecting&markingDPMCB40Ato63A,B-serieswith ratedshort circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-MCB 48 Supplying, erecting&markingTPMCB6A to 32A, with rated short- circuitbreakingcapacity (Icn) kAinprovided distributionboardasper specificationno. SW-MCB 49 Supplying, erecting&markingTPMCB40A to 63A, with rated short- circuitbreakingcapacity(Icn) 10kinprovided distributionboardasper specificationno. SW-MCB 50 Supplying, erecting&marking FPMCB6A to 32A, with rated short- circuitbreakingcapacity(Icn)0kAinprovided distributionboardasper specificationno. SW-MCB 51 Supplying, erecting&markingFPMCB40A to 63A, with rated short- circuitbreaking capacity(Icn)10kA inprovided distributionboar dasperspecificationno. SW-MCB 52 Supplying&erectingFRPboxof size150mmx125mmx100mm, 2.7mmthickcomplete on pole/wallas per specification No. CB-SB 53 Supplying&erectingFRPboxof size250mmx200mmx100mm, 2.7mmthick complete on pole/wallas per specification No. CB-SB 54 Supplying & erecting watertight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification No. CB-SB 55 Supplying & erecting MS pole bracket for guarding/LT OH line, fabricatedfrom angle iron 50x50x6mm and 550mm long for necessary nos. of providedinsulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT 56 Supplying & erecting MS pole bracket for guarding/LT OH line, fabricatedfrom angle iron 50x50x6mm and 1100mm long for necessary nos. ofprovided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT 57 Supplying & erecting MS pole bracket for guarding/LT OH line, fabricatedfrom ISM channel 75x40x6mm and 550mm long for necessary nos. ofprovided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT 58 Supplying & erecting MS pole bracket for guarding/LT OH line, fabricatedfrom ISM channel 75x40x6mm and 1100mm long for necessary nos. ofprovided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT 59 Supplying & erecting MS pole bracket for LT OH conductor fabricated from65x65x6 mm section, 550mm long for necessary nos. of provided insulatorsand erecting on pole with 50x6mm clamp complete as per specification no. OHPL/BKT 60 Supplying & erecting MS pole bracket for LT OH conductor fabricated from 65x65x6 mm section, 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OHPL/BKT 61 Painting of steel tubular/rail/ RSJ pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete as per specification no CWPTG/PTP 62 Powder coating of approved colour shade on both sides of provided iron work/MS/CRCA sheet steel work complete including anti-rust treatment complete. 63 Epoxy painting on both side of approved colour shade of provided iron work /MS/CRCA sheet steel work complete along with anti-rust treatment complete. 64 Painting of pipe pole up to 6m length alongwith street light/ polebrackets/ clamps etc by scrapping the existing paint complete as perspecification no CW -PTG/PTP. 65 Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 66 Supplying&erecting G.I. pipe ‘A’ class 25mm dia. for enclosing XLPEarmouredcable on wall/poleas perspecification no. CB-CE 67 Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP 68 Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specificationno EA-EP. 69 Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. 70 Supplying, erecting, testing & commisioning GI sheet 1.25 mm (18 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint as per specification no.CP/SH/CR 71 Supplying & erecting fuse bridges with base HC type fuse links 240V, 63A erected on polished wooden block. 72 Supplying & erecting fuse bridge with base 16A erected on provided switch board complete 73 Supplying and erecting HC pattern porcelain fuse bridges with base & HC type fuse links 240V, 32A erected on polished wooden block. 74 Supplying & erecting watertight terminal box of 1.6 mm (16 gauge) CRCA sheetof size 200 x 150 x 150 mm. complete on pole as per specification No. CB-SB 75 Supplying & erecting watertight terminal box of 1.6 mm (16 gauge) CRCA sheetof size 300 x 200 x 150 mm complete on pole as per specification No. CB-SB 76 Supplying & erecting watertight terminal box of 1.6 mm (16 gauge) CRCA sheetof size 150 x 100 x 100 mm complete on pole as per specification No. CB-SB 77 Supplying & erecting watertight terminal box of cast iron of size 200 x 150 x150 mm complete on pole as per specification No. CB-SB 78 Supplying & erecting watertight terminal box of cast iron of size 300 x 200 x150 mm complete on pole as per specification No. CB-SB 79 Supplying & erecting watertight terminal box of cast iron of size 150 x 100 x100 mm complete on pole as per specification No. CB-SB 80 Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mmthick complete on pole/wall as per specification No. CB-SB 81 Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mmthick complete on pole/wall as per specification No. CB-SB 82 Supplying & erecting FRP box of size 300mm x 200mm x 125 mm, 2.7 mmthick complete on pole/wall as per specification No. CB-SB 83 Supplying and erecting rolled steel joist (girder) pole 150 x 80 mm/150 x75 mm (14.9 kg /m) with base plate in provided foundation as per specification no. OH-PL/RSJ 84 Supplying and erecting G.I. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP 85 Supplying and erecting M.S. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP 86 Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast luminium housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. GODF/SL. 87 Supplying and erecting Gate/garden light fitting with 200mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG ODF/GLT 88 Supplying & erecting integral post top lantern fixtures suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL 89 Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP 90 Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP 91 Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP 92 Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessaryfittings complete as per specification no. FF-PP 93 Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC 94 Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG BKT/BPC 95 Supplying and erecting Street light bracket for erection of Single fitting on tubular welded pole with 40 mm. dia 1.0 m. length “B” class G.I .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no.FG-BKT/BPC 96 Supplying and erecting Street light bracket for erection of Double fitting on tubular welded pole with 40 mm. dia 1.0 m. length “B” class G.I .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no.FG-BKT/BPC 97 Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPEarmoured cable on wall/pole as per specification no. CB-CE 98 Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 99 Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 100 Supplying & laying (including excavation) reinforced cement concrete pipe of150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 101 Supplying & laying (including excavation) half round reinforced cement concrete pipe of150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 102 Supplying & laying (including excavation) reinforced cement concrete pipe of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc.complete. 103 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 104 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 105 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL 106 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL 107 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL 108 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL 109 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 110 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 111 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 112 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 113 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 114 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 115 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 116 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 117 Re-erecting PVC / XLPE armoured cable 2 to 4 Core up to 50 sq. mm. onwall with necessary material & G.I. earth wire. 118 Supplying and erecting mains with WP 2 x 2.5 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 119 Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 120 Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 121 Supplying and erecting mains with WP 4 x 4 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 122 Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB 123 Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB 124 Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB 125 Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB 126 Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 127 Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB 128 Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB 129 Supplying, erecting & marking DPMCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB 130 Supplying & erecting cast iron cable indicator plate buried along with route ofcable for PVC / XLPE armoured cable as per specification No. CB-CIP 131 Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mmthick complete on pole/wall as per specification No. CB-SB 132 Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mmthick complete on pole/wall as per specification No. CB-SB 133 Supplying & erecting FRP box of size 300mm x 200mm x 125 mm, 2.7 mmthick complete on pole/wall as per specification No. CB-SB 134 Supplying and erecting all aluminium stranded conductors 7/2.21complete. (Gnat) (73.77kg/km) as per specification No. OH-CON/AAC 135 Supplying and erecting all aluminium stranded conductors 7/3.10 complete. (Ant.) (145.0 kg/km) as per specification No. OH-CON/AAC 136 Supplying and erecting porcelain shackle type LT medium insulator 75x115 mm dia. with G.I. (Shackle) strips, nuts and bolts, complete. 137 Supplying and erecting aluminium bobbin with G.l. (shackle) strip, nuts complete. 138 Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, G.l. stay wire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected inprovided cement concrete foundation complete. 139 Supplying and erecting G.I. wall hook, 10 to 15mm dia and overall length 250mm including grouting, cement plastering etc. complete. 140 Supplying and erecting pole clamp made from 50x6mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of redoxide and two coats of aluminium paint complete 141 Supplying and erecting C type (half) clamps for pole made from 50x6mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat ofred oxide and two coats of aluminium paint complete. 142 Supplying and fixing MS pole cap fabricated from MS pipe or cast iron fixed to pole by means of set screws and 75mm deep. 143 Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level 144 Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concretefoundation and making the site clear by refilling the pitswith excavated materials and bringing it to the ground level. 145 Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. 146 Dismantling the existing lightning arrestor set, insulator from DP structure complete. 147 Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP 148 Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP 149 Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP 150 Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification noEA-EP. 151 Making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole) 152 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) 153 Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) 154 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). 155 Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). 156 Making M- 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole). 157 Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal /conical GI pole). 158 Making M-20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 2m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5m raising lowering high mast). 159 Supplying and erecting GI sheet 1.25 mm (18 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to beused for fabrication ofoxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 160 Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 161 Supplying and erecting slotted angles, frames etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority 162 Supplying and erecting static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. 163 Supplying and erecting static energy meter with 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA ) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. 164 Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company 165 supplying and erecting static energy Trivector meter 440 V 50 Hz. 20- 100A ISI mark meter AC 3 phase 4 wires LCD/LED display (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested for class 1.0 accuracy by electric supply company. 166 Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as perspecification No. CB-JT/LT 167 Providing & erecting epoxy straight through joint outdoor/indoor for LTXLPE armoured cable 25 to 50 sq mm., with necessary material as per specification No. CB-JT/LT 168 Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 70 to 95 sq mm., with necessary material as per specification No. CB-JT/LT 169 Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 120 to 185 sq. mm., with necessary material as per specification No. CB-JT/LT 170 Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 300 sq mm., with necessary material as per specification No. CB-JT/LT 171 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E )XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT 172 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E )XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 173 Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT 174 Supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 V 50 cycle AC having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating upto 16A to use independently or in conjunction with contactor. 175 Supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “ON” and switching “OFF” street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230 V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box. 176 Supplying and erecting four pole power contactor 430 V, 16 A for time switch complete erected on provided wooden block/ box, with necessary materials. 177 Supplying and erecting two pole power contactor 230 V, 32 A for time switchcomplete erected on provided wooden block/ box, with necessary materials. 178 Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials. 179 Painting of steel tubular / rail / RSJ pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete as per specification no CW -PTG/PTP 180 Powder coating of approved colour shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment complete. 181 Epoxy painting on both side of approved colour shade of provided iron work / MS / CRCA sheet steel work complete along with anti-rust treatment complete. 182 Supplying and erecting double pole metal clad switch with HC type fuse and neutral link 240V, 32A on iron / GI frame as per specification no. SW-SWR/MDP . 183 Supplying and erecting triple pole metal clad switch and fuse 415V, 32A on iron / GI frame as per specification no.SW-SWR/MTP. 184 Supplying and erecting triple pole metal clad switch and fuse 415V, 63A on angle iron / GI frame as per specificationno. SW-SWR/MTP. 185 Supplying and erecting ISI mark PWD/msedcl make apprved 63*415 vmainswitch prcelain top and base 186 Supplying and erecting ISI mark PWD/msedcl make apprved 63*415 vmainswitch prcelain top 187 Supplying and erecting ISI mark PWD/msedcl make apprved 63*415 vmainswitch prcelain base 188 Supplying and erecting ISI mark PWD/msedcl make apprved 63*415 vmainswitch ki-kat fuse 189 Supplying and erecting ISI mark PWD/msedcl make apprved 63*415 vmainswitch action rod 190 Remedial action/ troubleshuting of supply in occasion of short circuit fault on ovehead line condutor forrestoration of supply in street light or other electrification work by using hydruli platform/manually including changing jumper/sag-in-line/change shackle,spacer etc. with proior approval of MSEDCL competant authority 191 Providing temporary 2 x 2/4/6sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required accessories continuous 8 SWG G.I. Earth wire complete erected with gland and lugs and switchgears and required cable protector wherever necessary. 192 Making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete.(for 4 to 6 m pole) 193 Supply and Erection of New Pole Erection /Shifting Pole or verhead/Underground Cables MSEDCL Quotation under 1.3% DDF scheme (Incl Tech. Sanction+supervision charges) 194 Carrying out Servicing of DG set from 62.5 kVA to 200 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator 195 Painting of pipe pole up to 6m lengthlongwith street light/ polebrackets/ clamps etc by scrapping the existing paint complete as perspecification no CW -PTG/PTP. 196 Supplying and erecting GI earth conductor of required sizes used for earthing orany other purposes on wall with necessary GI clamps fixed on wall/cable/ conduitwith screws complete 197 Rent For Concrete Breaker and comperssor 198 Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08class having single piece pressure die-cast aluminium housing, having systemlumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K, THD <10%, p.f. >0.95, operating range of 140-270V, inbuiltsurge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including drivercomplete with minimum 2 Years warrantyas per specification No. FG-ODF/SL. 199 Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 13000 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K, THD <10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minium 2 Years arranty as per specification No. FG-ODF/SL. 200 Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. 201 Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level 202 Dismantling the existing overhead line including G.I. wires of all sizes withoutdamaging & making the coils in suitable sizes. 203 Dismantling the existing lightening arrestor set, insulator from DP structurecomplete. 204 Erecting the departmentally supplied WP LED street light / flood light fittingupto 80W. 205 Erecting the departmentally supplied LED street light / flood light fittingabove 80 to 150W. 206 Erecting departmentally supplied LED street light/ flood light Fitting above150 to 400W . 207 Erection of departmentally supplied ceiling fan with necessary materialscomplete. 208 Providing pair of duly tested rubber hand gloves as per IS :47705 suitablefor working upto 22 kV supply complete 209 Erection of departmentally supplied exhaust fan with necessary materialscomplete 210 Polycarbonate LED Street Light Lens 1x49 211 Polycarbonate LED Street Light Lens 1x21 212 Polycarbonate LED Street Light Lens 1x12 213 Polycarbonate LED Street Light Lens 1x30 214 Street Lighting Pole. Supply of 4.5 Mtr Length IP65 Aluminium pole 120mmx80mm, With powder coating PP Texture Grey Color, with Base Plate Size of 200x200x6mm. Thickness of the pole 3mm. Led Make Osram, BIS approved Driver, Surge Protection Device and 6A MCB. IP65 Led strip with Opal Diffusor for side lighting. (Non DSR Item) as per Quotation Rate analysis