}

Tender For Supply Of Arthoplasty Implants , Total Hip Replacement (Thr) – All Sizes Un Cemented: -(Metal On Poly) All Should Be Of Same Make Implant Should Be Usfda / Indianfda Approved Only , The Femoral Stem Should Have Morphometric Wedge Geometry And H, dausa-Rajasthan

Medical Health And Family Welfare has published Tender For Supply Of Arthoplasty Implants , Total Hip Replacement (Thr) – All Sizes Un Cemented: -(Metal On Poly) All Should Be Of Same Make Implant Should Be Usfda / Indianfda Approved Only , The Femoral Stem Should Have Morphometric Wedge Geometry And H. Submission Date for this Tender is 08-08-2025. Orthopedic equipment Tenders in dausa Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

50416294
Tender For Supply Of Arthoplasty Implants , Total Hip Replacement (Thr) – All Sizes Un Cemented: -(Metal On Poly) All Should Be Of Same Make Implant Should Be Usfda / Indianfda Approved Only , The Femoral Stem Should Have Morphometric Wedge Geometry And H
Tender
Indian
Rajasthan
Dausa
08-08-2025

Tender Documents

Tender Details

Supply of Arthoplasty Implants , Total Hip Replacement (Thr) – All Sizes Un Cemented: -(Metal On Poly) All Should Be Of Same Make Implant Should Be Usfda / Indianfda Approved Only , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating Coating Of Minimum 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed ( Optional ) , Incremental Neck Length Options, Two Offset Options Minimum And Made Up Of Titanium Material. , The Acetabular Shell Made Of Titanium Hemisphericalshould Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 38 To 64 Mm With Required Cancellous Bone Screws. Can Accomadate 22, 28, 32, 36, Head , Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 22Mm/28Mm, 32Mm, And 36Mm Heads. , Femoral Heads Should Bemetal Head With All Sizes 22Mm/ 28Mm/32Mm/36Mm With Minimum 4 Variable Necklength. , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) – All Sizes Un Cemented: -(Ceramic On Poly) All Should Be Of Same Make Implant Should Be Usfda / Indianfda Approved Only , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating . Coating Of Minimum 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed ( Optional ) , Incremental Neck Length Options, Two Offset Options Minimum And Made Up Of Ti6al4v Material. , The Acetabular Shell Made Of Titanium Hemisphericalshould Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 38 To 64 Mm With Required Cancellous Bone Screws. Can Accomadate 22, 28, 32, 36, Head , Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 22Mm/28Mm, 32Mm, And 36Mm Heads. , Femoral Heads Should Be Ceramic With All Sizes 22Mm/28Mm/32Mm/36Mm With Minimum 4 Variable Necklength. . , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) – All Sizes Cemented: - With Metal On Poly. Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda / Indianfda Approved Only , Cemented Femoral Stem Made Ofss Should Highly Polished, Offset Option Double Tapered With Collarless Design With Required Bone Cement. , The Cemented Cup Should Have Ultra-High Molecular Weight Polyethylene With Pmma Cement Spacer Easily Identifiable The Cup Position On An X-Ray. Cup Should Be Available In The I.D 22Mm/28 /32 / 36 Mm With Od 42 – 60 Mm With Two Packets Of Bone Cement. , Femoral Heads Should Be Cocr Metal Head With All Sizes 22Mm/28Mm/32Mm/36Mm With Minimum 4 Variable Necklength. , Total Hip Replacement (Thr) – All Sizes Hybrid ( Metal On Poly ) Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda / Indianfda Approved Only Note:- All Should Be Of Same Make Except Cement , The Acetabular Shell Made Of Titanium Hemisphericalshould Ha Coated. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 38 To 64 Mm With Required Cancellous Bone Screws. Can Accomadate 22, 28, 32, 36, Head , Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 22Mm,28Mm, 32Mm, And 36Mm Heads. , Cemented Femoral Stem Made Of Ss Should Highly Polished, Offset Option, Double Tapered With Collarless Design With Required Bone Cement. , Femoral Heads Should Be Metal Head With All Sizes 22Mm/28Mm/32Mm/36Mm With 4 Variabale Neck Length , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) – All Sizes -Hybrid: (Ceramic On Poly) Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda / Indianfda Approved Only , The Acetabular Shell Made Of Titanium Hemisphericalshould Ha Coated. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 38 To 64 Mm With Required Cancellous Bone Screws. Can Accomadate 22, 28, 32, 36, Head , Cemented Femoral Stem Made Of Ss Should Highly Polished, Double Tapered With Collarless Design, Offset Option, With Required Bone Cement. , Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible Toaccommodate22mm/ 28Mm, 32Mm, And 36Mm Heads. , Femoral Heads Should Be Ceramic With All Sizes 22Mm/28Mm/32Mm/36Mm With Minimum 4 Variable Necklength. . , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) Dual Mobility Uncemented– All Sizes ( Ceramic On Poly) Note: - All Should Be Of Same Make Implant Should Be Usfda / Indianfda Approved Only , The Acetabular Shell Made Of Titanium Should Ha Coated. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws. A. The System Should Compose Of A Liner And Poly Insert. B. The System Should Incorporate The Following Dual Points Of Articulation- C. 22.2Mm Or 28Mm Femoral Ceramic Head. D. Large Polyethylene Insert That Mimics A Femoral Head , Dual Mobility Liner- A. Dual Mobility Liner Should Be Made Of Cocr. B. The System Should Have Inner Change Locking Mechanism And Positive Rotation Tabs C. The Liner Should Come With Removal Tool Slot. D. The Liner Should Be Available In All Sizes- 36 To58 , Poly Insert- A. The Insert Should Be Made Up Of Highly Cross Linked Polyethylene Which Should Be Wear Resistant , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating Coating Of Minimum 50-Micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed ( Optional ) Two Offset Options Minimum And Made Up Of Ti6al4v Material. , Femoral Heads Should Be Ceramic With All Sizes With Minimum 4 Incremental Length , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Total Hip Replacement (Thr) Dual Mobility Cemented – All Sizes ( Metal On Poly) Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda / Indianfda Approved Only Can Be Converted With Uncemented Dm With Same Instruments On Table , Cemented Dual Mobilty Cup Should Have Sizes 45 To 63 , Cemented Femoral Stem Made Of Ss With Offset Option , Femoral Head(Cocr) Various Sizeswith 4 Incremental Neck Option , Unicondylar Knee Replacement Mobile Bearing Various Sizes With Cement Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda / Indianfda Approved Only , Femoral Component Made Of Cocr , Cocr Tibia Base Plate , Highlycross Link Poly , Complex/ Revision Hip Replacement With All Type & Size Of Wedges & Cages Etc.Thr. Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda / Indianfda Approved Only Note- Should Provide Quotation For Individual Components. , Revision Uncemented Stem,Ha Coating, Made Of Titanium Should Be Long And Length Should Be Between 180 - 380 Mm, Variable Offset Modular, Distal Fixing Stem , Revision Uncemented Acetabular Shell, Titanium, Have Multi Hole With Min. 8 Holes Andhighly Porous Coated. , Revision Uncemented Acetabular Shell Made Of Titanium, Should Provide Dual Mobility Cup Which Composed Of Cocr Liner And Highly Crossed Linked Polyethylene Which Support 22- And 28-Mm Femoral Metal Head.(Optional) , Acetabulum Augments , Acetabulum Mesh , Acetabulum Cages Various Sizes , Uncemented Acetabular Shell Especially Designed For Protrusion Which Is Peripherally Locking. , Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter. , Femoral Heads Should Be Cocr Metal Head With All Sizes 22Mm/ 28Mm/ 32Mm/ 36Mm. , Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-Degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads. , Total Knee Replacement Cemented (Tkr) Hi-Flex – All Sizes Note: - All Should Be Of Same Make Except Cement Should Provide Option Both Ps And Cr Knee In Same Implant Implant Should Be Usfda / Indianfda Approved Only , Primary Cemented Tkr- Femoral Components Cocr Various Sizes, Narrow & Standard Option With Ability To Accept Both Distal And Posterior Augment, Can Accommodate Constrained Poly,Ps & Cr Tkr Can Be Done With Same Instrument. Implants Should Have Good Survivourship Rate , Tibial Baseplate Various Sizes, Titanium, Anatomical Tibia Base Platewith Ability To Accept Extension Stem/ Rod,Tiba Can Accommodate Any Size ( + 2) Femoral Component , Highly Crossed Linked Polyethylene Various Sizes, Should Have Option For High Fkex, Constrained Poly Both Ps & Cr , Patellar Component Various Sizes , Bone Cement Note: - All Should Be Of Same Make Except Cement , Unicondylar Knee Replacement Fix Bearing Various Sizes With Cement Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda / Indianfda Approved Only , Femoral Component Made Of Oxanium. , Titanium Tibia Base Plate And 3. Poly , Highlycross Link Poly , Complex Primary Knee Replacement All Size Cemented Tkr Should Have Following Components Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda / Indianfda Approved Only , Femoral Components Cocr Compatible With Constrained Poly , Tibial Baseplate , Titanium, Anatomical Compatible To Stem Extension , Primary Highly Crossed Linked Polyethelene High Flex And Constrained , Bone Cement Antibiotic/ Normal , Fluted Stem , Patellar Component , Revision Knee Replacement All Size And Stems And Wedges Semi Constraint Tkr Should Have Following Components Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda Approved Only , Femoral Component Cocr Compatible With Stem Extension. , Tibial Baseplate Titanium Compatible To Stem Extension. , Semi Constrained Polyethylene. , Distal Augments. , Posterior Augments , Offset , Tibial Wedges Various Options , Patellar Component , Fluted Stem , Bone Cement , Revision Knee Replacement All Size And Stems And Wedges Hinge Tkr Should Have Following Components Note: - All Should Be Of Same Make Except Cement Implant Should Be Usfda / Indianfda Approved Only , Femoral Component Cocr Compatible With Stem Extension. , Tibial Baseplate Cocr Compatible To Stem Extension. , Constrained Polyethylene. , Distal Augments. , Posterior Augments , Offset , Tibial Wedges Various Options , Patellar Component , Fluted Stem , Bone Cement , Metaphyseal Femoral Sleeve , Metaphyseal Tibial Sleeve , Reverse Shoulder Replacement Implants – All Sizes All Should Be Of Same Make Implant Should Be Usfda / Indianfda Approved Only Platform Based Should And Can Be Converted Total/Reverse And Even Revisionglenoid Hase A Same Stem. Should Have Instrumens For Both Surgical Approaches Delto-Pectoral Or Supero-Lateral Approaches With Same Set Of Instrumets. , Cemented Stem , Trauma 11A Andstem Made Of Titanium Alloy (Ta6v)And Coated With Hydroxyapatite. Stem Is Available In 5 Sizes. Long Stem Available For Humeral Revision Cases Stem Has Mm Augment (For If The Stem Has Sunk Or Any Unseen Circumstances). , Hydroxy Apetitecoated Helical Glenoid Baseplate For Reverse Shoulder Arthroplasty. , Humeral Cup Has 8 Inclination With 2 Sizes 32Mm And 37Mnhumeral Cup Liner Has 0.+ 25 And + 5Mm Three Options For Same Cup. , Glenosphere Made Of Cocr , Note - Note Should Provide Quotation For Individual Components , Total Shoulder Replacement (Tsr) Implants- All Sizes Implant Should Be Usfda / Indianfda Approved Only All Should Be Of Same Make Note - Note Should Provide Quotation For Individual Components , Should Have Pe Glenoid With At Least Three Sizes , Trauma 11A Andstem Made Of Titanium Alloy (Ta6v)And Coated With Hydroxyapatite. Stem Is Available In 5 Sizes. Long Stem Available For Humeral Revision Cases Stem Has Mm Augment (For If The Stem Has Sunk Or Any Unseen Circumstances). , Humeral Head Various Size , Hemi Shoulder Replacement Implants – All Sizes Including Fracture Stem All Should Be Of Same Make Implant Should Be Usfda / Indianfda Approved Only Note - Note Should Provide Quotation For Individual Components , Stem Should Be Titanium With Proximal Porous Plasma Spray Coating. • It Should Be Convertible From Total To Reverse Shoulder. • Diameter Should Be In 1Mm Increment Or 2 Mm Increment With Fracture Stems. • Can Be Used With Or Without Bone Cement. • Fins With Holes Should Be Present To Tie The Tuberosity In Fracture Stems , Should Have Five Humeral Head Option • Should Have Module With Offset Option , Total Elbow Replacement (Ter) – Implants – All Sizes Implant Should Be Usfda / Indianfda Approved Only All Should Be Of Same Make Except Cement Total Elbow Replacement Set With Consisting Of Long Flange Plasma Spray Coated Humeral Stem And Side Specific Left/Right) Plasma Spray Coated Ulnar Stem Component With Antibiotic Bone Cement Quality Assurance And Should Be Mri Compatible. , Long Flange Plasma Spray Coated Humeral Stem , Side Specific Left/Right) Plasma Spray Coated Ulnar Stem Component With Antibiotic Bone Cementquality Assurance And Should Be Mri Compatible. , Total Knee Replacement Cemented (Tkr) Ps And Cr – All Sizes Note: - All Should Be Of Same Make Except Cement Should Provide Option Both Ps And Cr Knee In Same Implant Implant Should Be Usfda / Indianfda Approved Only , Primary Cemented Tkr- Femoral Components Cocr Various Sizes, Narrow & Standard Option With Ability To Accept Both Distal And Posterior Augment,Ps & Cr Tkr Can Be Done With Same Instrument. Implants Should Have Good Survivourship Rate , Tibial Baseplate Various Sizes, Titanium, Tibia Base Platewith Ability To Accept Extension Stem/ Rod,Tiba Can Accommodate Any Size ( + 2) Femoral Component , Highly Crossed Linked Polyethylene Various Size, Both Ps & Cr , Patellar Component Various Sizes , Bone Cement Note: - All Should Be Of Same Make Except Cement

Key Value

Document Fees
INR 2000 /-
EMD
INR 180000.0 /-
Tender Value
INR 90 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail