Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-08-2025 | Date Extend | Date | 28-08-2025 |
| Sl. No. | Item Description |
| 1 | Supply and Installations: Dual core architecture and dedicated network process unit forbetterperformance required, Management Purpose I/O Ports-1xRJ45 1xCOM RJ45, 8 x GbE copper 2 x SFP fiber minimum ports, Minimum 120 GB SSD-Local Storage/SSD, Firewall Throughput -38Gbps or higher, Firewall IMIX 18 Gbps or higher NGFW Throughput 6 Gbps or higher, IPS Throughput 6.8 Gbps. Concurrent Connections- 6 Million or higher, New Sessions Per Sec-145,000 or higher IpsecVPN Throughput 20 Gbps or higher, No. of IPSec VPN Tunnels-5000, Threat Protection Throughput- 1.3 Gbps or higher, SSLInspection Throughput-1.3 Gbps or higher, Capabletodo stateful inspection of packet passing through firewall. Capabletoconfigure firewallpolicy based upon network, protocol, users, group. No fixedzone to interfacemapping. Any interfacecan beconfiguredin any zone. should be ableto block traffic for country based upon Geo-IP.Must have Intrusion PreventionSystem capability and capability tocreatecustom IPS signature and policy. Capabletoidentify and blockcommand and control communication. Abletoblock malicious domain orweb category and enforcerestrictionon unwanted domain orURL. Abletocreate custom web category and enforcewebfilter policywith custom category. Webkeyword monitoring and enforcement to log, report or block web content matching keyword lists with theoption to upload customs lists. Applianceshouldhave feature supportfor both HA functionalities i.e. Active -Active and Active- Passive for redundancy. Firewall should have thefeasibility to choose/dedicate aport as HA link.Also, High Availability should support creation of multipleHA Link pairs to add resiliency in caseoneHA link Fails, so thatHA can facilitatedrobustly. Firewall should have the fesability of PoE/PoE plusports in the appliance to power up PoE devices like Acces points, without any external dependency. Port agnostic DPIscanning. Capabletoinspect TLS1.1,TLS1.2 and TLS1.3 inspection. Shouldbe ableto enforcepolicy on certificate state(likeinvalid date, untrustedissuer, namemismatch etc ..), protocol andcipher fordeeppacket inspection. Shouldbe ableto apply Application Filtering and Control. Advanced Threat Protection (detect and block network traffic attempting to contact command and control servers using multi-layered DNS, AFC, and firewall). Able to authenticateusers withlocal database and alsocapabilityto integrate active directory, LDAPserver, RADIUS Server, TACACS plusServer and eDirectory. BuiltinCapability forMulti Factor Authentication for Users without any additional cost. Must haveSD-WAN capability and have featuretocreate SLAprofilewith Jitter,Latency,Packet Loss. And same should bedemonstrated by Manufacturer/Vender in post tender POC if requested. SDWAN featuremust havesource, destination, service, application and user’s basepolicy creation capability. Also, should be able to loadbalanceor load sharetraffic across multiplegatewaysonthebasis of SLA parameters and sameshouldbe demonstrated by Manufacturer/Vender in post tender POC if requested. RouteBased/Interfacebased Ipsec Tunnel creationfacility should bepresent in addition topolicy-based tunnelscreation. Dynamic Routing Protocol such as OSPFv3 should be supported. Siteto site IPSec VPN with IKEv1 and IKEv2 key exchangecapability. Capability to apply Traffic Shaping on firewall rule, users, web category and application. One appliancereporting andcan integrate with external syslog server. Enforced password complexity feature for user and admin passwords. Built in 2FA capability with no additonal cost for local users, VPN users and admin users authetication. ProvidecompliancereportlikeHIPPA,SOX ,PCI,FISMA.CIPA. User based reporting and providethreat scoreto users based upon their activity. Logretention customization by category. Export reports as HTML, PDF, Excel (XLS), Firewall should support non-repudiation to strengthen logging datasecurity/privacy. ThreeYear Subscription licensefor Firewall, Gateway Anti-Virus, Anti-malware, DPISSL, Web Filtering Service, App Control Service, Botnet/CandC protection/ATP, zeroday protection,Intrusion Prevention System (IPS), 24x7 support,security and softwareupdates, adv. exchangewarrantyfortheperiod of 3 years. Firewall can beconfigured and managed via GUIorviaCLIconsole. Central management should provide feasability to use SD-WAN to provision VPN tunnels between multiple devices , if required in future. Central Management , if cloud based then should have hosting within Indian jurisdiction. Central management can schedule configuration backup and keep minimum two most recent backup. Central Management can giveaudit trail and full historical task of changes on a group or a policies. Inbuild diagnostic and policy testing tool in GUIfor troubleshooting.TCPdump utility in command linefor advancetroubleshooting. Firewall should beable tokeep minimum two firmwareversion and adminshould be ableto roll back to previous version from GUIwithout uploading firmware. ICSA or equivalent Indian Lab Firewall Certification. Firewall product/products family of Manufacturer should have MTCTE from TEC. ISO 9001. Manufacturer Support (TAC) Presencein India. SoftwareOS family shouldbehaving atleast oneCommoncriteriaEAL4 plus listed or equivalent Indian certification. Make in india firewall OEM Should be SOC2 Type 2 certified. Make- Fortinet/Sophos/Palo Alto |
| 2 | Supply and Installation: High End Switch should have 24 10/100/1000 Base-T Ports including 4 x1000Base loaded with 2 10SFP plusmodule single mode and 2x 1G SFP 1GSFP module, Switch should have Console Port (RJ-45 and Mini-USB console ports) for out-of-band CLI management, provide a direct, physical connection to the switch for management tasks, which can be especially useful if remote management is not possible, Switch should have separate 10/100/1000BASE-T RJ-45 Ethernet port for out-of-band IP management, even if the main data ports are saturated or malfunctioning. Switch should have1 x RJ-45 port Alarm Port for various purposes, such as signaling system alerts or connecting to monitoring devices. Should have USB 2.0Port Type A forconnecting storage devices for file sharing or providing power to external devices. 64K MAC Address and 4MB Packet buffer memory. 128 Gbps Switching capacity and 95 Mpps packet forwording rate. Power Support and Energy Efficiency: The Switch should support Power Input100 to 240 VAC 50/60 Hz with Maximum Power Consumption should be not more than42 W , while Standby Power Consumptionshould not be more than28 W. Switch should support Redundant Power Supply (RPS) supportfrom day1. The Switch Operating Temperature should be-5 to 50 °C (23 to 122 °F) with Storage Temperature • -40 to 70 °C (-40 to 158 °F). Surge Protection upto6 kV surge protection on all Ethernet access ports. Energy-Efficient Ethernet (EEE) standard and save power with shutoff LED and port shut-off and power on link while there is no activityand draw power only as per cable length used. IPv6 Support and Stacking Capabilities: Switch should be able to do Physical stacking upto9 switches in a stack with total 80 Gbps stacking bandwidth in Ring/chain topology. Switch should be able to do Virtual stacking/clustering of up to 32 units with Single IP Management upto 20 Gbps stacking bandwidth. The Switch should beIPv6 Ready Certificationfor IPv6 Ready Logo Phase-2. Layer 2 Features: Switch should support 802.3x Flow Control with HOL blocking, Switch shouldsupport802.1D, 802.1w , 802.1s. It also supportRoot Guard andLoop Guard. Switch should support jumbo Frame: up to 12 Kbytes. Support 802.1AX Link Aggregation,Max. 32 groups per device, 8 ports per group. Support ERPS (Ethernet Ring Protection Switching) version 2. Support Port Mirroring ( One-to-One, Many-to-One) , alsoSupports Mirroring for Tx/Rx/Both, upto 4 mirroring groups,Flow Mirroring,Supports Mirroring for Rx,VLAN Mirroring. Support Remote Switched Port Analyzer, to takes a mirrored copy of network traffic from within the switch to be sent to a destination. Switch should support L2 Protocol Tunneling to support one Layer 2 (L2) protocol within another L2 protocol for the purpose of transporting it across a network. Support Multi-Chassis Link Aggregation Group (MLAG). Layer 3 Features: Switch should support 256 IP interfaces , support Static Route,supportVRRP v2/v3. Switch should support RIPing, OSPF v1/v2, BGP v4. Switch should support VRF-Lite, IS-IS v4/v6, BGP/MPLS VPN, MBGP, Virtual Private Wire Service (VPWS),Virtual Private LAN Service (VPLS). QoS (Quality of Service): Switch should support Queue HandlingStrict Priority (SP),Weighted Round Robin (WRR) andStrictplusWRR ,Weighted Deficit Round Robin (WDRR). Should have Congestion Control protocol i.e. Weighted Random Early Detection (WRED) 802.1Qbb Priority-based Flow Control (PFC) for 10 GbE port. Bandwidth Control based on flow or Port min. 8kb. Support QoS based on Time , CoS ,Switch port,Inner/outer 802.1p Priority ,Inner/outer VLAN ID,MAC address,Ether Type,IP address,ToS/IP Preference,DSCP,Protocol type,TCP/UDP port, IPv6 Traffic Class, • IPv6 Flow Label. Security Features: Switch should support 12K MAC addresses per port/VLANfor connected devices, thus preventing unauthorized access and mitigating security risks. Switch should supportBroadcast/Multicast/Unicast Storm Control for effectively manage and mitigate the impact of excessive traffic on their network infrastructure, ensuring optimal performance and reliability by using any specifc protocl. Switch should supportDHCP Server Screening to prevent rogue DHCP servers from distributing incorrect or malicious IP configuration information to network. Dynamic ARP Inspection to avoidtraffic interception, packet sniffing, or denial of service attacks. IP-MAC-Port bindingin assiociation with IP Source Guard, DHCP snooping and Dynamic ARP Inspection (DAI). supportDuplicate Address Detection (DAD), ARP Spoofing Prevention. Should support Unicast Reverse Path Forwarding (URPF) and Traffic Segmentation. Switch should support SSL, TLS 1.0/1.1/1.2, SSH. OAM and AAA services: Switch should support Cable Diagnostics,802.3ah Ethernet Link OAM, unidirectional Link Detection, Dying Gasp,802.1ag Connectivity Fault Management (CFM),Y.1731 OAM, Optical Transceiver Digital Diagnostic Monitoring (DDM). Supports port/host-based access control, MAC-based Access Control (MAC) Support MAC based Identity-driven Policy Assignment. Should be SDN-enabledcompatible with Openflow 1.3, allowing the switches to be managed using an OpenFlow controller.Switch shuold be compatable with existing Network switches for HA mode.Make- Cisco/D-Link/Juniper |
| 3 | Supply and Installation: Switch should have 24x 10/100/1000BASE-T ports Ports with4 10G SFP plusports for uplink purpose. Switch should have Console Port (RJ-45) for out-of-band CLI management, provide a direct, physical connection to the switch for management tasks, which can be especially useful if remote management is not possible, Should have 16K MAC Address and 12MB Packet buffer memory. Switch should have 128 Gbps Switching capacity and 95 Mpps packet forwording rate. Power Support and Energy Efficiency: The Switch should support Power Input100 to 240 VAC 50/60 Hz with Maximum Power Consumption should be not more than30 W , while Standby Power Consumptionshould not be more than9 W. Operating Temperature should be-5 to 50 °C (32 to 122 °F) with Storage Temperature • -20 to 70 °C (-40 to 158 °F), Support Surge Protection upto6 kV surge protection on all Ethernet access ports. Support Energy-Efficient Ethernet (EEE) standard and save power with shutoff LED and port shut-off and power on link while there is no activityand draw power only as per cable length used , Also the complete switch can be hibernet during off period i.e. Night to save power. Layer 2 feature: support 802.3x Flow Control with HOL blocking, Switch shouldsupport802.1D, 802.1w , 802.1s. It also supportRoot Guard andLoop Guard Switch should support jumbo Frame: up to 12 Kbytes. Support 802.1AX Link Aggregation,Max. 8 groups per device, 8 ports per group. Port Mirroring (One-to-One, Many-to-One) , alsoSupports Mirroring for Tx/Rx/Both, Should support Remote Switched Port Analyzer, to takes a mirrored copy of network traffic from within the switch to be sent to a destination. Layer 3 feature: Switch should support 4 IP interfaces , support Static Route,124 IPv4 static route entries • 50 IPv6 static route entries. Should support Queue HandlingStrict Priority (SP),Weighted Round Robin (WRR) andStrictplusWRR ,Bandwidth Control with min granularity 10/100/1000 is 16 Kbps). Switch should support QoS based on Time , CoS ,Switch port,Inner/outer 802.1p Priority ,MAC address,Ether Type,IP address,ToS/IP Preference,DSCP,Protocol type,TCP/UDP port, IPv6 Traffic Class, support64MAC addresses per portfor connected devices, thus preventing unauthorized access and mitigating security risks. Broadcast/Multicast/Unicast Storm Control for effectively manage and mitigate the impact of excessive traffic on their network infrastructure, ensuring optimal performance and reliability by using any specifc protocol.SupportDHCP Server Screening to prevent rogue DHCP servers from distributing incorrect or malicious IP configuration information to network. Dynamic ARP Inspection to avoidtraffic interception, packet sniffing, or denial of service attacks. Switch should support IP-MAC-Port bindingin assiociation with IP Source Guard, DHCP snooping and Dynamic ARP Inspection (DAI). Support SSL, TLS 1.0/1.1/1.2, SSH.Switch should support Cable Diagnostics, Switch should carry Safety Protocl i.e. cUL, CB, CE, CCC, BSMI andEMI/EMCi.e. CE, FCC Class A, C-Tick, VCCI, BSMI, CCC. . Make- Cisco/D-Link/Juniper |
| 4 | Supply and Installation: Switch should have 8x 10/100/1000BASE-T Ports with2 x 1G SFP ports for uplink purpose. Switch should have 8K MAC Address and 4.1MB Packet buffer memory. 20Gbps Switching capacity and 14 Mpps packet forwarding rate. Power Support and Energy Efficiency: The Switch should support Power Input100 to 240 VAC 50/60 Hz with Maximum Power Consumption should be not more than7W , while Standby Power Consumptionshould not be more than3W. The Switch Operating Temperature should be-5 to 50 °C (32 to 122 °F) with Storage Temperature • -20 to 70 °C (-40 to 158 °F). Layer 2 Features: Switch should support 802.3x Flow Control, HOL Blocking Prevention ,Switch shouldsupport802.1D, 802.1w , 802.1s. It also supportLoopback Detection,Switch should support jumbo Frame: up to 10 Kbytes. Support 802.1AD Link Aggregation,Max. 4 groups per device, 8 ports per group. SupportPort Mirroring ( One-to-One, Many-to-One) , alsoSupports Mirroring for Tx/Rx/Both. Remote Switched Port Analyzer, to takes a mirrored copy of network traffic from within the switch to be sent to a destination. Switch Should support IGMP v1/v2 snooping, v3 awareness,IGMP authentication/filtering upto 256 groups, VLAN/host-based IGMP snooping fast leave Report suppression MLD Snoopingv1, v2 awareness. Support 802.1QVLAN , 256 static VLAN groups,Configurable VID from 1 - 4094, Asymmetric VLAN,automatically applying the correct VLAN and QoS settings when an IP phone is connected,Max. 10 user-defined OUI, Max. 8 default OUI, to uniquely identify devices on a network. Should support automatically detects and prioritizes surveillance video traffic on a network. Layer 3 Features: Switch should support 4 IP interface , support IPv6 Neighbor Discovery (ND),Static routing upto124 IPv4 /50 IPv6 static route entries. QoS (Quality of Service): Switch should support Queue HandlingStrict Priority (SP),Weighted Round Robin (WRR) ,Bandwidth Control with min granularity 10/100/1000 is 64 Kbps). QoS based on Time , CoS ,Switch port,Inner/outer 802.1p Priority ,MAC address,Ether Type,IP address,ToS/IP Preference,DSCP,Protocol type,TCP/UDP port, IPv6 Traffic Class. Security Features: Support64MAC addresses per portfor connected devices, thus preventing unauthorized access and mitigating security risks. Support Broadcast/Multicast/Unicast Storm Control for effectively manage and mitigate the impact of excessive traffic on their network infrastructure, ensuring optimal performance and reliability by using any specifc protocol. SupportDHCP Server Screening to prevent rogue DHCP servers from distributing incorrect or malicious IP configuration information to network. Offer is liable to be rejected if they don`t upload any of the certificates/ documents sought in the document. Support ARP Inspection to avoidtraffic interception, packet sniffing, or denial of service attacks.AMC/IP based ACL with Source/destination IP address mask. Switch should support IP-MAC-Port bindingin assiociation , DHCP snooping andARP Inspection. Switch should support SSH v2 andTLS v.1.2.OAM and AAA services:. Make-Cisco/D-Link/Aruba |
| 5 | Supply and Installation: Supply and Installation of 1G SFP Module. Make-Cisco/D-Link/Aruba |
| 6 | Supply and Installation: 4X4 Access Point Physical Interfaces : One 100/1000/2.5GBASE-T Gigabit Ethernet (RJ-45) ports with Auto Uplink (Auto MDI-X) supporting IEEE 802.3af or 802.3at Power over Ethernet (PoE),Two (2) Internal 3.1/4.3 dBi (2.4GHz/5GHz) antenna ,Four (4) LED: Power and Cloud connection: LAN speed: 2.4GHz status: 5.0GHz status,Power adapter (not included): 12V DC, 2.5A. Standards : 5.0GHz: 802.11a/n/ac/ax: 2.4GHz: 802.11b/g/n/ax , IEEE 802.11ax WiFi 6 standard , WMM - Wireless MultiMedia Prioritization , WDS- Wireless Distribution System , Power over Ethernet (PoE) IEEE 802.3af/802.3at. Security: Wi-Fi Protected Access (WPA, WPA2, WPA3), 802.11i, WPA2 Enterprise , Wireless access control to identify authorized wireless network devices , MAC address filtering with access control , 802.1x RADIUS support with EAP TLS, TTLS, PEAP, Neighbor AP detection, VLAN Support, Secure Socket Layer (SSL), Guest Network/Captive Portal, Bandwidth management, Link Layer Discovery Protocol. Network Management : Cloud based App Management for setup, monitoring and management from anywhere anytime (Remote configuration and management), Easy-to-use Web browser-based management GUI, Manageability : As standalone, Centralized Management through Mobile Application. Advanced Wireless Features : Wireless Distribution System (WDS), Bridge mode: Point-to-point wireless WDS mode, Bridge mode: Point-to-multipoint wireless WDS mode, Repeater mode,Adjustable Transmit Power Control (TPC), Device detection, Identify type of wireless clients in the network. Other Specifications : PoE power consumption: 25.5W, Business class WiFi based on next generation 802.11ax WiFi 6 technology on both 5.0GHz and 2.4GHz bands. Backward compatible to 802.11b/g/n/a/ac, Dual band 4x4 (2.4GHz and 5.0GHz) 8 streams of data for an aggregate throughput of up to 3.6Gbps, Theoretical Throughput per Band: 5.0GHz: 2400Mbps: 2.4GHz: 1200Mbps, Orthogonal Frequency Division Multiple Access (OFDMA), Multi-Gigabit Support, Target Wake Time (TWT), Basic Service Set Coloring (BSS Coloring), Bandsteering, Block SSID Broadcast, Ceiling mounting / Wall mounting, Bidir and MU-MIMO support. Warranty and Support : , 3 Years Centralized Management license included, 5 Years free latest firmware support, Rs. Make- Cisco/Netgear/Ruckus |
| 7 | Supply and Installation: Supports up to 8 10/100/1000Mbps Gigabit Ethernet PoE ports and 4 SFP slots, IEEE 802.3af/at PoE compliant to simplify deployment andSupports PoE up to 30W per port with 140W total power budget. 8 10/100/1000 Base-T Ethernet PoE Ports 4 Gigabit Combo (RJ-45/SFP) Ports Reset Button: reset to default setting, Switching Capability: 24Gbps MAC Address Table: 8K PoE Power Budget: 140W Packet buffer size: 4.1MB Jumbo Frame: 10K. L2 Features Auto-negotiation for port speed and duplex mode Spanning Tree Protocol-Support STP / RSTP / MSTP (max 16 instance)-Loopback Detection- BPDU Filter- BPDU Guard, LLDP IGMP v2/v3 Snooping: IGMP Querier, Immediate Leave MVR VLANs - 256 IEEE 802.1q tag based VLAN with 4K VLAN ID - MAC Based VLAN, Voice VLAN, Guest VLAN, Management VLAN Link Aggregation- LACP: 8 Groups, 8 Ports/Group-Static Trunk. Queueing Mechanism: SP and WRR Classifications based on- COS, COS DSCP, IP Precendence, Each port supports 8 queues Rate Limit (Port Based): Ingress/ Egress Port Flow Control.MAC address Binding Support Broadcast/Multicast/Unicast storm control IP and MAC ACL (Ipv4) RADIUS, 802.1x based Authentication Port Security, Protected Port Management ACL DHCP Snooping, DHCP Snooping option 82, IP Source Guard, IP-MAC-Port-VLAN Binding. Management Port Mirroring Support traffic statistics, FAN less design, Provide IPv4 Web-based management IPv4 DHCP Client Configuration Backup and Recovery Dual firmware images and Configuration files Error Disabled, Bandwidth Utilization, SNMP v1/v2c/v3 C11 Remote Server Telnet, SSH,HTTP, HHTPS RMON, SNTP Ping, Traceroute EEE, Port Statistics. 330(W) x 230(D) x 44(H) mm, AC Power: 100 to 240 V, 50-60 Hz, Input Surge Protector. IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX, IEEE 802.3ab 1000BASE-T, IEEE 802.3az IEEE, IEEE 802.3at and IEEE 802.3af. Temperature : Operating: 0°C ~ 40°CStorage: -40°C ~ 70°C Humidity: perating: 10% ~ 90% RH (Non-condensing) Storage: 5% ~ 90% RH (Non-condensing) Display Each port have a dedicated LED status display. Link/Act Hardware Factory Reset button. Traffic on a port can be mirrored to another port for analysis with a network analyzer. Make- Cisco/Digisol/Juniper |
| 8 | Supply and Installation: Wall Mount 9U x 550 W x 500 D, 1U Cable Manager, Roof Mounted Fan Unit / 90 CFM / 230V AC,6 Way 5 Amp Power Distribution Unit,Mounting Hardware Kit,Conforms to DIN 41494 OR equivalent ISO Standards, Adjustable 19” equipment mounting verticals provide the better mounting flexibility, and maximizes the usable mounting space,Depth adjustable mounting slots,Front Glass Door with Lock, Top and bottom Panel with ventilation and cable entry facility, Provision to mount the cooling fans on the top panel, Powder coated finish with Seven Tank pretreatment process meeting all industry standards, Grounding and Bonding Options. 100% assured compatibility with all equipments conforming to DIN 41494. Make- D-Link/Schneider/Dynamic |
| 9 | Supply and Installation: Wall Mount 17 U x 600 W x 600 D, 1U Cable Manager, Roof Mounted Fan Unit / 90 CFM / 230V AC,6 Way 5 Amp Power Distribution Unit,Mounting Hardware Kit,Conforms to DIN 41494 OR equivalent ISO Standards, Adjustable 19” equipment mounting verticals provide the better mounting flexibility, and maximizes the usable mounting space,Depth adjustable mounting slots,Front Glass Door with Lock, Top and bottom Panel with ventilation and cable entry facility, Provision to mount the cooling fans on the top panel, Powder coated finish with Seven Tank pretreatment process meeting all industry standards, Grounding and Bonding Options. 100% assured compatibility with all equipments conforming to DIN 41494. Make- D-Link/Schneider/Netrack |
| 10 | Supply and Installation: 27 U Rack The rack should have 1U Cable Manager, The rack should have minimum 2 Nos of Roof Mounted Fan Unit / 90 CFM / 230V AC, It should have 6 Way 5/15 Amp Power Distribution Unit, Casters Set of 4 (2Nos with Brake and 2Nos without Brake). The rack should have adjustable Levellers set of 4, Front Glass Door-24U-600mm Rear Door Vented-24U-600mm, Vented Side Panels-24U-800mm (set of 2) with Slam Latch. Conforms to DIN 41494 OR equivalent ISO Standards, Ral 9005(Black) Powder Coated, Equipment Mounting on DIN Standard 10mm Sq. Slots / Direct M6 Tap, Mounting Angle should be 19” Mounting angle made of formed steel, Vented and Cable entry/exit cut outs from Top and Bottom. Static Load should be 250 kgs or better.Depth adjustable mounting. Provision to mount the cooling fans on the top panel. Make- D-Link/Schneider/Dynamic |
| 11 | Supply and Installation: Fiber is optimized for operation at 1310 nm and at 1550 nm. The Fiber should be Armoured 6 core unitube9/125 µm SM fiber with central loose tube jelly compound, Glass Yarns in between Steel Tape and Loose Tube. Armour Tape : Corrugated steel Tape Armoured Jacket material : HDPE, Outer diameter : 9 ± 0.3 mm Thickness of the Jacket: 1.8plus0.2 mm Pulling Tension: Short Term 2000N, Long term 1000N, Crush Load: 3000N/100mm, The Fiber Operating Temperature should be– 20 deg C toplus 60 deg C and The Fiber Max Attenuation ± 0.36 (db / km) @ Operational Wavelength 1310 nm and,± 0.22 (db/ km) @ Operational Wavelength 1550 nm. Fiber - type should be 9/125 / G.652Dand Refractive Index should be 1.4670/1.4675.Value for Mode-filed/Cladding Diameter (um) 9.2 ± 0.4 and 125 ± 0.7. Dispersion value (=3.5 (=18 (ps/(nm-km) and PMD value (=0.2 (ps/km) and Cable Cut-off wavelength (=1260 (nm). The Fiber should followStandards: ISO 11801,IEC 60793-1/60794-1-2 andITU-T-REC G.652D. Testing methods are in accordance with the following standards: ITU-T G.652.D, IEC 793-1 and Telecordia : GR-20 Core - Make- D-Link/Commscope/Belden |
| 12 | Supply and Installation-CategoryPatch Panel should be 24 Port 1U Size loaded with 24 port RJ-45 IO/Jack,Mounts in standard 19 inch racks,Patch panel should have rear cable manager for improvement management,Patch panel suitable for Category 6 keystone,Panel material should have SPCC with 1.5mm thickness and Black Color,Support bar material should have SPCC with 1.5mm thickness and Black Color,RJ-45 jack housing should be PBTplusGlass fiber UL94V-O and Contact brackets should be PBTplusGlass fiber UL94V-O,Rj-45 contact material should be phosphor bronze with nickel plated and plug contact area finish with 50 micro-inches Gold plated, Rj-45 jack life should be 700 times minimum,Operating temperature should be -10° Celsius to 60° Celsius,Make- D-Link/Commscope/Belden |
| 13 | Supply and Installation: Category 6 patch cords 1 /2 Mtr with four pair twisted cable terminated with RJ45 modular plugs at both the ends,Patch Cord should have TIA/EIA 568C.2 standard.,Shall be backward compatible with Category 5 and Category 5e systems, Category 6 patch cord should be 100% factory made and performance tested,Category 6 patch cord length requires – 2 meter/ 1 meter,Color code for Patch Cord: Grey,Performance Characteristics ,Patch cord conductor should be 24 AWG, multi-strands ,Patch core conductor metal should be made from bare copper,Insulation material should be high density polyethylene,Patch cord jacket should be LSZH,Modular Connector/Plug Characteristics,Patch cord plug should be gold plated,Contact blade of plug should be made from copper / alloy,Insertion cycle should be 750 times,Temperature range should support from 10° Celsius to 60° Celsius.Make- D-Link/Commscope/Belden |
| 14 | Supply and Installation: Adopts high precision ceramic ferrule with good concentricity, Fiber corningsingle mode G652D,G657A,G657B, Cable Type 0.9mm, Optical Fiber – Corning Single Mode, Connector: Zirconia ceramic ferrule, Pre-radiuses and pre-polished ferrule, Mechanical specification Apex Offset :-( 50 um, Mechanical specification Fiber Heightplus (-) 100 nm, End-face radius of Curvature 7mm ( R (25mm, Repeatability ((-) 0.2 db, Working Temperature :- -4 0 c ~plus 85 o C Storage Temperature:- 40 o C ~plus85 o C, Type-_LC-LC SM Duplex. Make- D-Link/Commscope/Belden |
| 15 | Supply and Installation: The Fiber Rackmount LIU loaded having Adapter panel fixed on drawer base frame, with Adapters and with Pigtails and assembled with splice tray as per the Loaded fiber port requirement and their applicable accessories, Suitable to mount at different positions (depth wise) on standard 1U 19 inch racks. Drawer type to pull out for easy maintenance when assembled in racks, Cold Rolled Steel material with black powder coating, Three types of cable entry holes for different size cables through cable glands, covered with rubber cable grommets/covers, Splicing of 24 fibers in each plastic fiber splicing trays with integrated cable spool design.Non removable top cover and no rear cover. Drawer type to pull out for better access of interior, As per the Loaded fiber port requirement , Loaded 6/12/24 (SC Simplex) adapters with SC SIMPLEX Pigtails on rackmount ports.As per the Loaded fiber port requirement Accessories kit consists of Cable management rings/Cable saddles, Cable glands (PG13.5, 2 nos), Splice rods, Blanking clips, Velcro ties, Cable ties, Cable inlet/outlet hole covers(2 types, 2 nos each). Cable management rings/Cable saddles can be mounted inside the rackmount, no provision to mount outside in front of the adapter panel.Suitable for storing up to 3 meter of 900 µm tight buffered fiber pigtail per adapter. Panel Dimensions : 482 x 220 x 44.3 mm (Length x Width x Height)Splice Tray Dimensions : 220 x 90 x 15 mm (Length x Width x Height)Port identification numbers printed on the Adapter panel. Standards: Comply as per ANSI/TIA-568-C.3, ISO/IEC 11801, RoHS Compliant. Operating Temperature :-20 °C toplus 70° C Installation Temperature : -20 °C toplus 70° C. Make- Commscope/Belden/Digisol |
| 16 | Supply and Installation: Category 6 keystone jacks are RJ45, 8 position 8 contact socket. Category 6 keystone jacks are suitable for 22-26 AWG stranded and solid wire. Keystone jacks are compatible with both 110 and Krone punch down tools. The Category 6 keystone jacks shall be backward compatible with Category 5e, 5 and 3 cords and cables. It compliance with ANSI/TIA/EIA 568 C.2 standard. The Category 6 keystone jacks shall be of a universal design supporting T568 A and B wiring. Color of Keystone Jack: White Category 6 keystone jacks housing made from PC, UL 94V-2 material. RJ45 Jack contact material should be phosphor bronze with nickel plated. Finished with 50 micro-inch gold plated on plug contact area. IDC Housing made from PC, UL 94V-2. Terminal material should be Phosphor bronze with tin plated. Should have IDC CAP and material of IDC Cap should be PC, UL 94V-2. Current rating should be 1.5A. Life of Jack should be 750 cycles minimum (ISO/IEC 11801/IEC 60603-7-4). Operating Temperature should be -10° Celsius to 60° Celsius.Make- D-Link/Commscope/Belden.Supply and Installation: Face plate should Face Plate should have shutter to protect from dust. It should have write on labels in transparent plastic window – supplied with plate. Face plate material: ABS with white color. Screw should be supplied with face plate. Make- D-Link/Commscope/Molex |
| 17 | Supply and Installation: Voltage-140V~300V AC, Frequency-50Hz ± 10%, 230 V AC Nominal, 50Hz ± 1Hz, Modified Sinewave, Transfer time-Typical 4-8ms, Capacity-1000VA/600W, SMF (Sealed Maintenance Free), 12 V/ 7AH x 2 Batteries, Recharge time-6 Hrs to 90% after complete discharge, 0 Degree~40 Degree C, 0~90% RH Non- Condensing noise level ( 40dB. Rack and Connectors also required with Wall Mount of UPS in a proper manner.. Make- Microtek/Eaton/APC |
| 18 | Supply and Installation: 10 KVA UPS DEFAULT: 192VDC, ADJUSTABLE: 216VDC, SINGLE PHASE WITH GROUND, Nominal Voltage- 208VAC / 220V AC / 230VAC 165-285V AC, Frequency Range-40Hz 55Hz @50 Hz System, 208VAC / 220V AC / 230VAC, AC VOLTAGE REGULATION, Frequency Range-Mains Mode(Synchronized Range): 45Hz - 55Hz / Battery Mode, AC TO DC MODE-Zero, INVERTER TO BYPASS MODE-Zero, Bypass to Inverter Mode- (5ms. Battery Mode- Pure Sinewave. AC Mode/Battery Mode-87% / 91%. Battery Type- Tublar Battery: OK(With Charger Cut-Off Voltage adjustable from, Battery Charging Amp-2/4/ 8 AMP. (Default: 8 AMP). LCD Display- Load Level, battery level, Ac Mode, Battery Mode, Bypass Mode. Alarms- Fault: Continuously Sounding. RS-232 / USB and OPTIONAL SNMP- Supports Windows% 2000/2003/XP/Vista/2008/7/8, Linux and MAC. Dimension-562x250x830. . Make- Microtek/Eaton/APC |
| 19 | Supply and Installation: 12V SMF battery 65 AH. Make- Exide/Okaya/Amaron |
| 20 | Supply and Installation: RJ 45 Connector Box, Housing: PC, UL94V-2, transparent color, Contact Terminal: Copper Alloy, Finished: 03MU micro-inch gold plating, Use for 24-26 AWG stranded wires, meet wiring scheme T568A/T568B, RJ 45 connector with installation with prior approval from EIC. Make- D-Link/Belden/Commscope |
| 21 | Supply and Installlation: Supply and Installlation of Heavy Duty Floor race way(19L*9w*CM) Make- TARKAS/Serplex/Dolphy or equivalent make complete in all respect with the prior approval of EIC. |
| 22 | Supply and Instalation: Supply and Installation of Heavy Duty Bolt and Dril for Floor raceway |
| 23 | Supply and Installation/Configuration/Programing: Next-generation Voice System.offers IP at the core with onnectivity to the all-pervasive legacy and newgeneration advanced wireless telecom networks like POTS, ISDN, T1/E1, and GSM/3G/4G/VoLTE. supports up to 99 VoIP (SIP) trunks, 40 GSM ports, 8 T1/E1 ISDN PRI ports, and 64 analog trunks with up to 999 UC users, 96 digital users, and 240 analog users are available. 19? Rack Mount with 4U Enclosure .900 MHz Dual Core processor.It should work both on PRI or SIP 99 voip trunk.Its should support upto 240 analogue and 900 digital user with addionla license.Its should also support digital phone.with minimum 1CO2, plus DKP2 plus SLT 16.Minimum 1 T1 PRI CARD,4 Voip card support upto maximum no of IP Phones.Scalable Port Capacity for Connecting Trunks and Devices.Support for Multiple User Extensions and VoIP Users.Support Multi Building Telephony.Easy Management of Users and Devices through a Unified Interface. Modular and scalable with additional cards for more trunks and users. Call Features: IVR, call forwarding, call hold, call transfer, call conferencing, call recording. VoIP Support: SIP-based VoIP for seamless communication. Voicemail: Voicemail-to-email and voicemail box features. Multi-Site Support: Supports remote locations and distributed networks. Integration: Features like call queues and automatic call distribution (ACD). Connectivity: Remote access for users and management via mobile apps or web interfaces. Web-Based Management: Easy setup and management through a web interface. Video Conferencing: Built-in video conferencing support.Security: Built-in firewall and secure voice encryption. The system supports SIP VoIP technology, enabling businesses to leverage Internet Protocol (IP) for calls, reducing costs and enhancing flexibility.SIP-based VoIP support makes it compatible with a wide variety of SIP phones, softphones, and other VoIP devices. Make- Alcatel/Matrix/Avaya. |
| 24 | Supply and Installation: IP Phone - IP Phones with preloaded all VOIP Phone Handset features. Audio features: Codec: G.722, G.711(A/µ), G.729, G.726, G.723 DTMF: In-band, Out-of-band (RFC 2833) and SIP INFO Full-duplex hands-free speakerphone with AEC,VAD, CNG, AEC, AJB, AGC. Phone Features: Abbreviated Dialing, Call Pick Up, and Internal Call Restriction Call Hold, Mute, and DND One-touch Transfer and Hotline Redial, Auto Call Back (ACB), and Auto Answer Call Forward, Call Waiting and Call Transfer 3-way Conferencing and Conference Multi-party Emergency Call and Conferencing. Display: 128 x 64 Graphical LCD, LED for Call, Message Wait Indication Intuitive user interface with Icon. Networking and Security: Extended (Proprietary) SIP Protocol IP assignment: Static, DHCP SRTP TLS QoS: 802.1p/Q tagging (VLAN). Physical Features: Desk mount External AC Adaptor: AC 100~240V Input and DC 5V/600mA output Operating humidity: 10 ~ 95% Operating temperature: 0 ~ 45 °C Dimension (W x H x D): 163 x 210 x 101 mm. Operating Temperature: 0° C to 45°C. Operating Humidity: 10 - 95% (Non-condensing). Built with advanced security protocols, the VP210 incorporates TLS/SRTP encryption for voice security, dynamic lock and PIN dialing for restricted access, and user authentication controls. HD Voice Quality: Clear audio for superior communication. User-Friendly Interface: Ergonomic design with an intuitive interface. Programmable Keys: Access frequently used features and extensions with ease. Secure Communication: With TLS/SRTP encryption and user authentication, your communication is always protected. 2 x 10/100 Mbps LAN and PC Ports33 keys1 x RJ9 Handset Port1 x RJ9 Headset Port1 USB PortDimension (W x D x H): 207X335X78 Certifications CE, FCC-15 (Class B), RoHS. Make- Alcatel/Matrix/Avaya |
| 25 | Supply and Installation: 24-10/100/1000 Base-T auto-sensing PoE plusports, 2 dedicated 100/1000 Base-X Fiber SFP ports, Performance Specification- Bandwidth: 52 Gbps non-blocking, Mean Time Between Failures (MTBF): 1,051,375 hours (120 yrs), Heat Dissipation (worst case, all ports used, full PoE, line-rate traffic) (BTU/hr): 780.20 BTU/hr, Forwarding modes: Store-and-forward, 8 Priority queues, Weighted Round Robin (WRR) and Strict Priority, MAC Address database size: 8,000 media access control (MAC) addressesVLAN: 64-128 Multicast groups, Number of DHCP snooping bindings: 256, Access Control Lists (ACLs): 100 shared for MAC, IP and IPv6 ACLs (ingress), Packet forwarding rate (64 byte packet size) (Mpps) : 38.6, Jumbo frame support: Up to 9K packet size, Packet buffer memory (Dynamically shared across only used ports): 0.5 MB, 1G Copper Latency(64-byte packets): 3.749µs, 1G Fiber Latency (64-byte packets): 3.129µs, Max power (worst case, all ports used, full PoE, line-rate traffic) (Watts): 228.53 W, Auto Power Down, PoE budget: 190W, IEEE Network Protocols- IEEE 802.3 Ethernet,IEEE 802.3u 100BASE-T,IEEE 802.1Q VLAN Tagging,IEEE 802.3ab 1000BASE-T,IEEE 802.3af PoE,IEEE 802.3at PoE plus ,IEEE 802.3az Energy Efficient Ethernet (EEE),IEEE 802.3ad Trunking (LACP),IEEE 802.3z Gigabit Ethernet 1000BASE-SX/LX,IEEE 802.3x Full-Duplex Flow Control,IEEE 802.1AB LLDP with ANSI/TIA-1057 (LLDP-MED),IEEE 802.1p Class of Service,IEEE 802.1D Spanning Tree (STP),IEEE 802.1s Multiple Spanning Tree (MSTP),IEEE 802.1w Rapid Spanning Tree (RSTP),IEEE 802.1X Radius network access control. Network Security and Traffic- IEEE 802.1x,Guest VLAN,RADIUS-based VLAN assignment via .1x,RADIUS accounting,Network Storm Protection,DoS attacks prevention,Broadcast, Unicast, Multicast Protection,Access Control Lists (ACLs) L2 / L3 / L4,IP-based ACLs (IPv4 and IPv6),MAC-based ACL,TCP/UDP-based ACL,MAC lockdown,MAC lockdown by the number of MACs,IEEE 802.1x Radius Port Access Authentication,Control MAC # Dynamic learned entries: 600,Control MAC # Static entries :20. L2 Services-IEEE 802.1Q VLAN Tagging,Video VLAN,Voice VLAN,IEEE 802.3ad - LAGs - LACP ( (8 LAGS with max. of 8 members in each LAG)),Broadcast Storm Control,IGMP Snooping (v1, v2 and v3),IGMP Snooping queriers. Network Monitoring and Discovery Services-802.1ab LLDP,SNMP V1, V2, V3,RMON 1,2,3,9. QoS-Port-based rate limiting,Port-based QoS,DiffServ QoS,IEEE 802.1p COS,IPv4 DSCP,Diff Serv QoS,IPv4 ToS. Management- Cloud/Remote management,Password management,Configurable Management VLAN,Admin access control via Radius and TACACS plus ,Web-based graphical user interface (GUI),IPv6 management,Dual Software (firmware) image,Dual Configuration file,SNTP client over UDP port 123,SNMP v1/v2,SNMP v3 with multiple IP addresses,RMON 1,2,3,9,Port Mirroring,Many to One Port Mirroring,Cable Test utility,SSL/HTTPS and TLS v1.0 for web-based access,TFTP/HTTP File transfers (uploads, downloads),HTTP Download (firmware),Syslog (RFC 3164). LED- Per port: Speed, Link, Activity,Per device: Power, Fan and PoE Power Status. Operating Temperature: 32° to 122°F (0° to 50°C), Operating Humidity: 95% maximum relative humidity, non-condensing, Storage Temperature: – 4° to 158°F (–20° to 70°C), Storage Humidity: 95% maximum relative humidity, non-condensing, Operating Altitude : 10,000ft (3,000m) maximum. CE mark, commercial, FCC Part 15 Class A, VCCI Class A, Class A EN 55022 (CISPR 22) Class A, Class A C-Tick, EN 50082-1, 47 CFR FCC Part 15, SubpartB, Class A, CCC, UL listed (UL 1950)/cUL IEC 950/EN 60950, CB report / certificate IEC 60950-1:2005 (ed.2) plus A1:2009 plus A2:2013, CE LVD: EN 60950-1: 2006plusA11:2009plusA1:2010plusA12:2011plusA2:2013, BSMI: CNS 14336-1, True Lifetime hardware replacement warranty, Lifetime free latest firmware support, Replacement with New Product Only No refurbished Products. Make- Netgear/Juniper/Cisco |
| 26 | Supply and laying Flexible Pipe 25/32mm for Data and electrc wire laying |
| 27 | P/F of PVC BOX 9x3 complete in all respect as per approval of EIC. |
| 28 | P/F of PLATE 9x3 complete in all respect as per approval of EIC. |
| 29 | Supply,Laying and Testing: 3*1.5 sqmm wire (3 pair cable), Flame Retardent(FR), Multistrand. Make- Polycab/Havells/KEI |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy