| Sl. No. | Item Description |
| 1 | Surface dressing and site clearance not exceeding 15 cm deep including site clearance in soft/ loose soil complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5 meter wide and not exc. 1.50 meter in depth for foundation etc and for manholes etc not exceeding 10 Sqm on plan and not exceeding1.5 meter depth and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Treating the top surface of filled earth at the rate of 7.50 liters of emulsion per square meter of surface complete all as specified and directed. |
| 4 | Treating the soil under plinth protection at the rate of 5 liters of emulsion per square meter of surface area complete all as specified and directed. |
| 5 | Removing excavated materials (soils) to a distance not exc. 50 meter and depositing where directed at a level not exc. 1.50 above the starting point complete all as specified and directed. |
| 6 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soft/loose soil complete all as specified and directed. |
| 7 | Material & labour for approved soil filling under the floors, spreading and leveling in layersnot exceeding 25 cm thick, well ramming including watering as required complete all as specified and directed. |
| 8 | Material & labour for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed. |
| 9 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 10 | Form work to sides of pillars, posts, struts, piers, columns etc square or rectangular or polygonal rough surfaces of concrete complete all as specified and directed. |
| 11 | Form work to sides and soffits of beams lintels etc finished fair complete all as specified and directed. |
| 12 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick flat fair finished surfaces of concrete complete all as specified and directed |
| 13 | Form work to the edge of concrete flat not exceeding 200 mm thick complete all as specified and directed |
| 14 | Supply & fix mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 15 | Supply & fix mild steel TMT bars 5 mm dia and over upto and including 10mm dia as in stirrups complete all as specified and directed. |
| 16 | M&L RCC 1:2:4 (nominal mix) type B-1 (using 20 mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs. under reamed piles and mass concrete complete all as specified and directed. |
| 17 | M & L RCC 1:2:4 (nominal mix) type B-1 (using 20 mm graded stone aggregate) as in Columns, pillars etc complete all as specified and directed. |
| 18 | M & L RCC 1:2:4 (nominal mix) type B-1 (using 20 mm graded stone aggregate) as in beams, lintels over 1.5 m span etc complete all as specified and directed. |
| 19 | M&L for RCC M 25 type A-1 (using 20 mm graded stone aggregate) for roof slabs supported on walls, beams and the like. Complete all as specified and directed. |
| 20 | Material & labour brick work with fly ash bricks in CM 1:6 brick straight or curved on plain exceeding 6m mean radius complete all as specified and directed. |
| 21 | Material & labour for brick work with fly ash bricks in CM 1:6 brick straight or curved on plain to any Radius in Half brick thick wall complete all as specified and Directed. |
| 22 | Material & labour for 10 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed |
| 23 | Material & labour for 15 mm thick rendering on fair faces of brick work or concrete surfaces, in CM (1:4) surface finished even and smooth without using extra cement complete all as specified and directed |
| 24 | Matertal & labour for 5 mm thick plaster in CM 1:3 on ceiling surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 25 | Material & labour for hardcore of broken bricks gauges n.exc. 63mrn, deposited spread and leveled in layers n.exc, 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 26 | M&L 75 mm thick cement concrete 1:3:6 type C-2 (using (40 mm graded stone aggregate) as in sub base complete all as specified & directed |
| 27 | M&L Non Skid ceramic ( coloured tiles ) tiles 7mm to 8 mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, (400 x 400 x 10mm) in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & including screed Bed or bedding layer of mortar 15 mm thick in CM 1:6 complete all as specified and directed. |
| 28 | Material & labour for glazed coloured ceramic tiles of size 450x300x7-8mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/ coloured cement to match laid over & including Screed bed or bedding layer of mortar 10 mm thick in C M 1:4, for laying floor finish complete all as specified & directed. |
| 29 | M&L 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in path/plinth protection , finish even & smooth without using extra cement complete all as specified & directed. |
| 30 | Material & labour for preparation of new plastered surfaces of walls etc and applying two coats of cement base paint over a coat of primer complete all as specified & directed |
| 31 | M & L for preparation of new plastered surfaces of walls and applying three coat of white wash complete all as specified and directed. |
| 32 | Material and labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed. |
| 33 | M& L for PCC padding 1:2:4 type B-1(using 20 mm graded stone aggregate) average thickness 25mm,finished fair and even without using extra cement on roof surfaces complete all as specified and directed. |
| 34 | M&L 20 mm thick screed bed in cement mortar 1:4 as on roof surfaces finished even & smooth complete all as specified and directed. |
| 35 | Material & labour for cleaning of plastered /concrete surfaces and applying priming coat using bituminous primer @ 0.30 Kg/Sqm, followed by evenly a tack coat @ 1.20 Kg/Sqm. using with 85/25 grade bitumen, over laid with 3mm thick APP modified polymeric water proofing membrane with non woven polyester reinforced of weight not less than 3.6 Kg/Sqm unrolled and bonded to substance with side and end laps 75mm and 100mm as per manufacturer’s instructions and finished top of APP water proofing polymeric membrane with a coat of hot blown industrial bitumen 05/25 grade @ 1,20 Kg/Sqmand finally finished with a coat of bituminous aluminium paint @ 0.20 Kg/Sqm complete all as specified and directed |
| 36 | M&L For framed work as in door or gates of angle or other section with gusset plate, rails, braces confirming to Fe 410 W (Gde E-250 quality- A ) Complete drill for fixing of steel sheeting or other covering. Doors etc to be prepare for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, finning rails and guides) and hanging also fastening and fixing complete all as specified and directed. |
| 37 | Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to getter with solvent cement, supplying & fixing in the frame at site as per specification & drawing for Item No. 08080 on page No 156 of SSR 2010 (Part-Il). Complete all as specified and directed. |
| 38 | Supply & fix 125mm size aluminium alloy handles cast type anodized complete all as specified & directed. |
| 39 | S&F aluminium tower bolts 150mm long, of extruded section complete all as specified and directed. |
| 40 | M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 41 | Supply & fixing steel C.P. grating 100/125 mm dia as reqd atsite complete all as specified and directed. |
| 42 | S&F for 110 mm bore PVC floor traps plain with grating and 300 mm long out let including jointing with cement concrete type B -1, 1:2:4 complete all as specified & directed. |
| 43 | Supply and fix PVC bends 110mm bore, any radius complete all as specified & directed. |
| 44 | Supply & fix steel windows or ventilators fixed type including hold fast, complete all as specified & directed. |
| 45 | Supply & fix 3mm thick sheet glass, pin headed, and glazingwith oil putty/beading in square not exceeding 0.50sqm each pane complete all as specified & directed |
| 46 | S8F Gun -metal, globe or gate valves, with iron wheel head screwed, both ends for iron pipe and fixed for 20 mm pipe, Complete all as specified and directed |
| 47 | S&F Gun -metal globe or gate valves, with iron wheel head screwed, both ends for iron pipe and fixed for 15 mm pipe. Complete all as specified and directed |
| 48 | S & F soap dish MS approximate size 160x160x90 mm fixed to plugs with chromium plated brass screws. Complete all as specified and directed |
| 49 | Supply & fix angular valve, 15 mm dia, cast copper alloy, chromium plated, fancy type with long shank and cup, screwed down, high pressure screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified & directed. |
| 50 | Supply & fix rotational moulded polyethylene water storage tanks 1000 liters capacity, (cylindrical, vertical in closed top) hoisted and fixed in position with all fittings complete all as specified and directed |
| 51 | Supply & fix in PVC low level flushing cistern of 9 to10 ltrs capacity, ISI Marked, white, symphonic action type with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm bore, suitable for low level cistern complete all as specified & directed |
| 52 | Supply & fix 15mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed. |
| 53 | Supply & fix 20 mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed. |
| 54 | Supply & fix butt hinges, 100 mm long of stainless steel, complete all as specified & directed |
| 55 | Supply & fix PVC connections of 450mm long suitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed. |
| 56 | Supply & fix PVC ball valves, high pressure with polyethylene float and fly nut complete screwed for iron pipe 20mm bore complete all as specified & directed. |
| 57 | Supply & fix vitrous china wash down water closet pan (padestal pattern) , white ( excluding fixing bolts, flushing cistern and flush pipe), Complete all as specified and directed |
| 58 | S&F white plastic seat cover for WC ( E.T ) white including MS CP or aluminium hinging device complete all as specified and directed |
| 59 | S&F for CP Health Faucet brass body with wall hook and one meter SS braided rubber hose pipe complete all as specified and directed. |
| 60 | S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all specified and directed |
| 61 | S&F PVC (SWR), junction single, (Single T) equal or unequal 110 mm bore Complete all as specified and directed |
| 62 | Supply & fix vitreous china wash hand basin, white, flat back of size 550x400mm (excluding taps, waste chain and plug and porcelain stopper) but including brackets and pedestal suitable for 15mm dia pipe complete alt as specified & directed |
| 63 | Supply and fixing PVC waste pipes of 40/32mm bore suitable for wash hand basins/sinks complete all as specified & directed. |
| 64 | Supply & fix pillar taps, fancy type cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered \"hot\" or \"cold\" with long screwed shanks and fly nut screwed for iron pipe of 15mm bore complete all as specified & directed |
| 65 | S&F 600mmx750mm fancy type bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed |
| 66 | M&L Concrete bed to drain pipes 150mm in cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 67 | M&L Slat-glazed stoneware drain pipes 150 mm dia laid in trenches and jointed complete all as specified and directed. |
| 68 | M&L Cement concrete in foundations, filling and mass-concrete in PCC 1:4:8 Type D-2 (using 40 mm graded stone aggregate). Complete all as specified and directed. |
| 69 | M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 Complete all as specified and directed |
| 70 | M&L PCC(1:3:6) type C-1 (using 20mm graded stone aggregate) as in benching to man hole complete all as specified and directed. |
| 71 | M&L for construction on septic tanks , exc in ordinary soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame vent shaft and sludge chambers etc complete for 25 users. Complete all as shown on drg No TD-217 sheet 1/7 to 7/7 and directed by Engineer-in-Charge. |
| 72 | M&L for construction on soakage well exc. in ordinary soil, foundation in PCC 1:3:6, well of Hony combed and solid in M-25 concrete, including intercepting chamber, screen chamber brick work in CM, RCC cover slab in M-25 RR masonry/ filling with brick bats, complete of size 1.8m dia x 3.00m deep. Complete all as shown on drg No TD-309 sheet 1/4 to 4/4 and directed by Engineer-inCharge |
| 73 | M& L Cement concrete as in cover slabs (for manholes etc PCC 1:2:4 type B-1 (20 mm graded aggregate) set in cement mortar I:6 including as per requirement of form work complete all as specified and directed |
| 74 | M&L for laying 60 mm thick machine pressed precast PCC coloured interlocking paver block moulded in PVC frame / mould any shape and size conforming to IS 15658-2006 of M-35 grade of approved design with gray cement and pigment to match shade / colour / matrix of tiles set and bedded over 25mm thick fine river washed sand duly compacted with surface vibrator laid over compacted sub soil in flooring complete all as specified and directed. |
| 75 | M&L Sand for cushioning, interlocking tiles joint to be filled with sand, including spreading and levelling in layers n exc 25 mm thick. complete all as specified & directed. |
| 76 | M&L 75 mm thick cement concrete 1:3:6 type C-2 using (40 mm graded stone agg) as in sub base complete all as specified and directed. |
| 77 | S&F Pre-cast cement concrete block masonry 1:2:4 Type B-1 (using 20mm graded stone aggregates) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified & directed. |
| 78 | Demolition of brick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc.all as specified & directed |
| 79 | Dismantling timber scantlings 40 sq. cm and over in section as in framed work, in any position as in roof truss and Purlins complete all as specified & directed. |
| 80 | S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or fiat sections) including distance pieces, cleats etc conforming to IS 1161-1979 Fe410W (Gde E-250) Quality -A. Complete all as specificed and directed. |
| 81 | Supply and fix Pre-painted galvalume aluminium zinc coating Cl based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified including Dismantling of Old asbestos cement ( Corrugated or Semi Corrugated Sheets in roof Covering complete all as specificed and directed. |
| 82 | Supply and fix pre-painted galvalume aluminium zinc coating Gt based plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed With self tapping screws as specified and directed. |
| 83 | S&F mild steel flat iron as in wind ties including cutting drilling holes and securing bolts confirming to FE 410-0 of 310-0 complete all as specified & directed |
| 84 | Dismantling ceiling board of insulation boards etc any thickness complete all as specified and directed |
| 85 | Material & labour for provision of Powder Coated Gl frame work(snap grid) suitable for size as in false ceiling of size 600mmx600mm consisting of followings and all as directed:-i) Sections incorporated in frame work shall conform to designation 63400 given in IS: 737-1986. ii) The snap grid shall consist of Gl anodized main /cross tee of size 36.5mmx25mmx1.4mm thick and 25mm x 25m x 1.4mm thick, respectively. iii) Snap grid frame shall be fixed to ceiling with supporting hangers consisting of S & F 2mm dia mild steel Gl wire. iv) The main and cross tees shall be jointed at junction/crossings with Gl anodized angle bracket, of size 15mmx15mmx1.4mm thick, fixed with suitable mild steel, bolts, nuts and washers all as per manufacturer\"s instructions. v) The snap grid (main/cross tee section) shall be supported at ends all along the wall with aluminium anodized angle of size 25mmx25mmx1.4 mm anodized thick. vi) Size of the snap grid shall be 605mm by 605mm. vii) Minimum average thickness of anodizing shall be 15 micron. |
| 86 | S&F 4 mm thick gypsum board in ceiling size 60cm x 60cmfixed to any snap gird complete as per manufcturet\"s instructions complete all as specified & directed. |
| 87 | Demolition of stone Slab Laid Bedded and pointed in any Mortar and tiles of any Description or thickness in floor, Apron etc complete all as specified and directed. |
| 88 | M & L for Machine cut Kota stone slab Flooring 20mm to 25 mm thick laid over cement screed base laid and jointed with grey cement sturry mixed with pigment to match the shade of the slab including rubbing and polishing including Laid over & including 15mm thick Screed Bed or bedding layer of mortar for laying floor finish in CM 1:6 Complete all as specifed and directed |
| 89 | M & L for Machine cut Kota stone slab 20mm to 25 mm thick as in riser of steps,skirting,dado and pillar, laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including Laid over & including 10mm thick Screed Bed or bedding layer of mortar for laying floor finish in CM 1:4 Complete all as specifed and directed. |
| 90 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each ccmplete all as specified & directed. |
| 91 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm & n exc 4 Sqm each complete all as specified & directed. |
| 92 | S&F in repair Steel windows box type using \"P\" section comprising double frame for gauge and glazed Skelton shutter jointly with fiat iron 40mmx3mm complete including hinges, handle, tower bolts, stops. lugs etc all as shown on drawing.Note (i) For the perpose of measurement & payment double shutter with frame shall be considered as one unit (ii) Unit rate quoted against this item shall also include the iron mongreries shown on drgs (iii) gaurd bars glazing & Wire mesh shall be measured and paid for separately complete atl as specified and di ected. |
| 93 | Supply & fix galvanized mild steel wire cloth with 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified & directed. |
| 94 | S&F 3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading ) in square n.exc 0.5 Sqm in each panes complete all as specified and directed. |
| 95 | S & F Mild steel pain black sheet 3 mm thick in wall cladding, steel gates and similar work. cut to size, holes punched; including round headed screws, clout nails or rieveted and fixed to wood o steel framing with plain 40 mm la joints with rieveted or welded seams, including bending or turning up mitred angles, etc as required complete all as specifed and directed. |
| 96 | S & F Framed work such as grills, grating, angles and Flats etc for ornamental and intricate design with ends of bars shouldered and/or riveted or forged into spikes frame guard bars barred iron doors ladders ladders framed blauster walk ways railing frame work of water tank and similar work including tower bolts, sliding door bolts, Handles and all other necessary fitting required confirming to Fe 290 Gde E-165 complete all as specified and directed. |
| 97 | Taking down of cement plaster of any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified & directed. |
| 98 | M & L 15 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed. |
| 99 | Materials & labour for preparation of newly plastered surface and finishing the surfaces of wall with wall putty and applying two coat of Oil Bound distemper over one Coat of suitable Primer of, any colour, complete all as specified & directed |
| 100 | Materials & labour for preparation of Old plastered surface and finishing the surfaces of wall with wall putty and applying two coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. |
| 101 | M & L Preparation of new plastered surface of wall by applying 2mm thick wall care putty and making the surface smooth finishing walls and applying Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) using roller for painting complete all as specified & directed. |
| 102 | M& L Preparation of Complete removal of existing treatment by mechanical means plastered old surface of wall and applying 2mm thick wall care putty over one coat of primer and making the surface smooth and applying two coat of Acrylic smooth exterior paint of required shade ( two coat @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10sqm) using roller for painting complete all as specified & directed. |
| 103 | Demolition of cement concrete of ground floor n exc 15 cm in depth in any position not otherwise specifically provided for, complete all as specified & directed |
| 104 | M&L PCC 1:3:6 type C-O (using 12.5 mm graded stone aggregate) for hold fast pressed steel frame and angle iron door frames etc complete all as specified & directed. |
| 105 | S&F Pre-cast cement concrete block masonry 1:2:4 Type B-1 (using 20mm graded stone aggregates) with solid blocks, exc. 10 cm in width and setting in cement mortar, 1:6, including excavation for fixing and making good complete all as specified and directed. |
| 106 | Taking down carefully any type of battens or conduit point wiring with or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs/ isolators, fan regulators, tube tight fittings etc removing material from site complete all as specified & directed |
| 107 | Material & labour for point wiring with FRLS PVC insulated 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, unsheathed copper conductor cable in and including PVC concealed conduit of size 20mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunk zinc coated pressed steel terminal boxes including all cutting / chases etc in walls, with 3mm thick plastic laminated sheet cover including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth dolly complete all as specified and directed for One Tube light/bulb/street light point controlled by one, one way switch 05 / 06 Amps. |
| 108 | All as per item No 108.00 here - in - before but One ceiling fan point controlled by one, one way switch 05/06 Amps. |
| 109 | All as per item No 108.00 here - in - before but One exhaust fan point controlled by one, one way switch 05/06 Amps. |
| 110 | All as per item No 108.00 here - in - before but One 3 pin, 05/06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch. |
| 111 | All as per item No 108.00 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch. |
| 112 | Supply & fixing switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed |
| 113 | Supply & fixing socket outlet 5 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed. |
| 114 | Supply and fixing of decorative LED Tube light fitting 1x20 Watt , environmental friendly, energy efficient MS batten with retrofit T8 polycarbonate LED tube-01 NO, with batten and all accessories complete all as specified & directed. |
| 115 | Supply and fix lamp holder , PVC / polycarbonate type back plate suitable for batten fitting complete all as specified & directed |
| 116 | Supply & fix lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified & directed. |
| 117 | Supply & fixing of ceiling rose, 3 terminal PVC polycarbonate isolated body complete all as specified & directed |
| 118 | Supply and fixing sheet metal enclosure, Triple pole and neutral AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & 1K 09 protection including provision for four pole isolator/MCB as incomer with metal double door and flush to wall including all cutting etc complete all as specified & directed. |
| 119 | Supply and fixing Isolator 4 pole \"B\" series 100 amps capacity AC 415 V, 10kA, complete all as specified and directed. |
| 120 | Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8way, with 200 Amps rated complete all as specified & directed. |
| 121 | Supply & fixing MCB SPN, AC, 240 volts of 32 to 63 Amps, C curve, 10 kA, complete all as specified and directed |
| 122 | Supply and fixing MCB SP, AC, 240 volts of 06 to 32 Amps, C curve, 10 kA, complete all as specified & directed. |
| 123 | Material and labour for sub main wiring with 06 Sqmm nominal cross sectional area. two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRIS-FLEXIBLE WIRING CABLE, CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid nonmetallic PVC concealed conduit of 25 mm dia, medium grade with all MS conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directedNote:- One meter of conduit along with 2x6 sq mm wire and one 6.0 sq mm earth shall be measured as one unit length |
| 124 | Supply, laying commissioning, testing of XLPE underground LT cable 1100 volts grade of size 16 Sqmm 3.0 core armoured. PVC sheathed with aluminium conductor heaw duty complete all as specified & directed |
| 125 | Supply / laying and fixing 40mm bore galvanized steel tubes with all fittings, light grade, laid in trenches for cable protection complete all as specified & directed. |
| 126 | M&L for washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling and hard punning complete all as specified & directed. |
| 127 | Material and labour for continuous brick edging with width equal to the depth of the brick of whole sub class \"B\" bricks laid on edge complete all as specified & directed. |
| 128 | Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with Gl wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB\"s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around Gl earth plate, Gl pipe medium grade 20mm nominal bore watering pipe Gl sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B-1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C-1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified & directed. |
| 129 | Supply and fixing LED building security light fitting 1x35 Watt luminaries with die cast aluminium housing comprising epoxy powder coated enclosed with glass cover in frame with high power LED white lamp of capacity 35 watt including making connections complete with bracket fitting made out of Gl pipe medium grade including clamp sand nuts and bolts. |
| 130 | Taking down Ceiling fan and hook, sealing cable end dismantling blades and removing fans and blade to stores for safe custody complete all as specified & directed. |
| 131 | Supply and fixing new ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor ( BLDC) complete all as specified and directed. |
| 132 | MP.L for Ceiling fan hook made from steel structural, bracing support bend into shape for hanging of ceiling fan complete all as specified and directed. |
| 133 | Supply and fix desert cooler electric driven single phase 230 Volt metallic body (Gl) , thickness not less than 1.5mm capacity of water not less than 70 Ltr , 1440 RPM with copper winding and power consumption not more than 240 watt, 50 Hzs complete all as specified and directed. |
| 134 | Supplying and fixing decorative LED tube light fitting 1x10 watt surface mounted, with extruded polycarbonate, integrated lamp & driver , with opal diffuser and decorative end plates. complete with accessories complete all as specified & directed |
| 135 | Supplying and fixing decorative LED tube light fitting /warm 1x20 watt surface mounted, with extruded polycarbonate , integrated lamp & driver , with opal diffuser and decorative end plates complete With accessions complete all as specified & directed |
| 136 | Supplying and fixing LED bulk head light fitting wall mounted With back lit LED 10 watt, IP-66,complete with all accessories complete all as specified & directed. |
| 137 | Supply and fix exhaust fan 300 mm , single phase , 50 HZ with double ball bearing heavy duty all with all including all fixing material complete all as specified & directed. |
| 138 | Supply and fixing in repair LED security light fitting1x25/30 Watt luminaries with die cast aluminum housing IP-66 comprising epoxy powder coated enclosed with glass cover embedded lens in frame with high power LED white lamp type complete all as specified and directed. |
| 139 | Supply & fixing MCB, DP (Double Pole), AC, 240 volts, B series capacity 32 Amps to 40 Amps 10kA and making connections complete all as specified & directed. |
| 140 | Taking out old unserviceable LT cable any size and Supply, laying commissioning, testing of XLPE underground LT cable 1100 volts grade of size 10 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in tranches, fixing on wall, under road crossing through protection pipe etc complete as specified and directed |