supply installation testing and commissioning of some additional Data networking and allied infrastructure including Access Point at Proposed IntegratedCourt Complex (G+6) Building at Alipurduar District.- 1 Supply & Laying of 20mm PVC conduit pipe ( Laying Over Surface or Through Cable Tray as required) with same OEM accessories ISI standard MMS. Make- AKG/Precision/Supreme 2 Supply & Laying of 25 mm dia HDPE Pipe with all accessories as required for the entire system with all OEM accessories as per site conditionMake:- Finolex/Oriplast/Supreme, Quality :- ISI approved 3 Supply & Laying Solid PVC Cable Duct. Make: Precision/AKG/Supreme 4 SITC of Cutting Channel of 43 mm X 43mm Size on masanry wall incl. S & F heavy gauge polythene pipe dia as stated below by means of iron hooks and Supplying and drawing 18 SWG GI Wire as fish wire with mending good damages to building works with 25 mm dia 3 mm thick polythene pipe without earth continuity wire. 5 SITC of stackable, Layer 3, fully managed, 1RU, GE Switch to be operated on 200-240VAC, 50 Hz Supply, with perpetual license of OEM, having minimum technical specification: 24-port 100/1000X SFP stackable L3 switch with 4 SFP+ ports and 2 fixed power supplies (Dual power supply from day 1, 128 Gbps Switching Capacity, 16K MAC, 4K VLAN, 40Gbps stacking bandwidth, static routing, RIPng, OSPFv3, BGP, IEEE 802.1Q, IEEE 802.1v, IEEE 802.3ac, IEEE 802.1p, IEEE 802.3ad, QoS based on VLAN, port, MAC,ACL, RADIUS, TACACS+, DHCP snooping, IP source guard and Dynamic ARP Inspection, IEEE 802.1x, SNMPv6, Telnetv6, SSHv6, IGMP snooping, MLD snooping, PIM-SM, console port, USB or equivalent interface, Port and VLAN mirroring, UDLD, Open FlowMake: Cisco, Juniper, Extreme, Allied telesis , Netgear, ZYXELWarranty: 03 (Three) Years onsite comprehensive OEM warranty with parts and service. 6 SITC of Layer 2 , fully managed, 1RU, GE Switch to be operated on 200-240VAC, 50 Hz Supply,withoneyearsoftwarerenewablelicenseofOEM,havingminimumtechnical specification :a) 24 x 10/100/1000 Mbps host ports (Minimum).b) 4x 1GE SFP portc) Fanless operation with operating temperature up to 45°Cd) 1 GB DRAM and 512 MB Flash RAM (Minimum).e)SoftwaresupportwithIPv4routing(900 staticroutes),multicastrouting(IGMP)including necessary software licensef) Minimum switching capacity of 56Gbpsg) Number of VLAN Supported: 4K (Minimum).h) Total number of MAC Address: 16,000 (Minimum).i) Minimum Security features e.g. Dynamic Host Configuration Protocol (DHCP) Snooping,DynamicARPInspection, Access control lists (ACLS) for IPv6 and IPv4 security and Quality- of-Service(QoS)ACLelements,SNMP,MACaddressnotification,Spanning-TreeRoot Guard (STRG), IGMP filtering etc.Applicablestandards:IEEE802.1p:CoSprioritization,IEEE802.1Q:VLANtagging, IEEE802.1X:PortAccessControl,IEEE802.3:10BASE-T,IEEE802.3u:100BASE- T,IEEE 802.3ab: 1000BASE-T, IEEE 802.3z: 1000BASE-X, IEEE 802.3x:Pause, Frames/FlowControl,IEEE802.1D:SpanningTreeProtocol,IEEE802.1s:Multiple instancesofSpanningTreeProtocol(MSTP),IEEE802.1w:Rapidreconfigurationof Spanning Tree Protocol, IEEE 802.3ad: Link Aggregation Control Protocol, Make: Cisco, Juniper, Extreme,HP, Netgear, ZYXEL Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. 7 SITC of Layer 2 , fully managed,PoE enabled, with PD: minimum 370 Watt (should have minimum 15.4 Watt per Port) 1RU, GE Switch to be operated on 200-240VAC, 50 Hz Supply,withoneyearsoftwarerenewablelicenseofOEM,havingminimumtechnical specification :a) 24 x 10/100/1000 Mbps host ports (Minimum).b) 4x 1GE SFP port including modular and field replaceable SFP module of same ratingc) Operating temperature up to 45°Cd) 1 GB DRAM and 512 MB Flash RAM (Minimum).e)SoftwaresupportwithIPv4routing(900 staticroutes),multicastrouting(IGMP)including necessary software licensef) Minimum switching capacity of 56Gbpsg) Number of VLAN Supported: 4K (Minimum).h) Total number of MAC Address: 16,000 (Minimum).i) Minimum Security features e.g. Dynamic Host Configuration Protocol (DHCP) Snooping,DynamicARPInspection, Access control lists (ACLS) for IPv6 and IPv4 security and Quality- of-Service(QoS)ACLelements,SNMP,MACaddressnotification,Spanning-TreeRoot Guard (STRG), IGMP filtering etc.Applicablestandards:IEEE802.1p:CoSprioritization,IEEE802.1Q:VLANtagging, IEEE802.1X:PortAccessControl,IEEE802.3:10BASE-T,IEEE802.3u:100BASE- T,IEEE 802.3ab: 1000BASE-T, IEEE 802.3z: 1000BASE-X, IEEE 802.3x:PauseFrames/FlowControl,IEEE802.1D:SpanningTreeProtocol,IEEE802.1s:Multiple instancesofSpanningTreeProtocol(MSTP),IEEE802.1w:Rapidreconfigurationof Spanning Tree Protocol, IEEE 802.3ad: Link Aggregation Control ProtocolMake: Cisco, Juniper, Extreme,HP, Netgear, ZYXELWarranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. (for CCTV and AP) 8 SITC of Dual Band Wireless Access Point with POE Injector 802.3ax GIGABIT.Dual-band radios; supports 256-QAM 2X2 MIMO with 2 Spatial Streams; 20, 40, and 80 MHz Channels; 1.488 Gbps data rates on dual concurrent radio operations; Packet Aggregation (AMSDU, AMPDU); Reduced Interface Spacing; Layer 2 and Layer 3 Layer 3 routing, 802.1q, DynDNS, DHCP server/client, BOOTP client, PPPoE and LLDP; Security: Stateful Firewall, IP filtering, NAT, 802.1ax, 802.11i, WPA2, WPA TripleMethodology Rogue Detection: 24x7 dual-band WIPS sensing, on-board; IDS, and secure guest access (hotspot); Quality of Service (QoS) WMM, WMM-UAPSD, 802.1p, Diffserv, and TOS; Operating Channels: 2.4 GHz band: channel 1 through channel 13, 5.2 GHz band: channel 36 through channel 165.Make: Cisco, Juniper, Extreme, Netgear, ZYXELLicence: 03(Three) Years subscription with 24x7 Comprehensive on-site support for 03(Three) Years. 9 SITCof1G Base SRMultiMode modularand fieldreplaceable SFPmodule ofsame rating of Ethernet Switch & OEMMake: Cisco, Juniper, Extreme,, Netgear, ZYXEL Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. 10 SITCofMULTITUBE DOUBLESHEATHEDSTEELARMOUREDOFCcable, 6F,6T, 50/125 Micron, OM3. Make: R & M, Belden, Tyco, ComscopeWarranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. 11 SITC of Multi Mode LIU, 12F, 1U Drawer shelf, Fully loaded with SC,OM3 Pigtails,Adapters,Splice Trays, Fiber Management Rings and Splice Slvees.Make: R & M, Belden, Tyco, Comscope, Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. 12 SITCofDuplex Multi mode 50/125 OM3LSZH Armoured Fiber PatchCable, SC- SC/ SC-LC/ LC-LC as per sites requirements - 3 MTRMake: 3C3, R & M, Belden, Tyco, ComscopeWarranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. 13 SITCofNetworkingHorizontalunArmouredCable,1000Base-T(GigabitEthernet), 100Base-T (Fast Ethernet), 10Base-T (Ethernet), 1-500 MHz (Minimum), Category 6, 4- Pair,F/UTP,23AWGsolidbarecopperconductorswithFEPinsulation,polyester separator, overall shield, Flame arrest jacket LSZH OUTER sheath COVERas to standard of ISO/IEC 11801Ed. 2.0, EN 50173-1 and TIA/EIA 568C.Make: R & M, Belden, Tyco, Comscope, Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. 14 SITC of CAT 6 F/UTP 24 Port Modular fully loaded patch Panel ISO 11801 AMD 1 Class EA TIA-568-C.2 Cat 6 ANSI/EIA-1069-A IEC 60603-7Make: R & M, Belden, Tyco, Comscope, Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. 15 SITCofCAT6InformationOutlet, STPdie-castJackwithdustcover,180°cableexit faceplate & backbox, Make: R & M, Belden, Tyco, ComscopeWarranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. (CCTV 173 nos., AP 32 nos. and LAN point 375 nos.) 16 SITCofPATCHCHORDCategory 6 4-Pair, SF/UTP,Horizontalcable,23AWGsolid bare copperconductors WITH RJ45 CONNECTOR AT BOTH END 0.5MTR LENGTHMake: R & M, Belden, Tyco, ComscopeWarranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. 17 SITCofPATCHCHORDCategory 6 4-Pair, SF/UTP,Horizontalcable,23AWGsolid bare copperconductors WITH RJ45 CONNECTOR AT BOTH END 2 MTR LENGTHMake: R & M, Belden, Tyco, ComscopeWarranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service. 18 SITC of Floor Mounted Cross Connect Equipments Network Rack27U x 1000 x 800 Rack - Front Glass Door with Cam Lock - Fan Unit of 360CFM(Min) / 230 Volt - 4no - 6; Way 5A PDU, along with input Cable - 2no - H/w Packet of 20 - 8no - 1U PVC Cable Manager - 6no. Ref. Make: Tata, Vertiv, Netrack, Valrack, Legrand, Rittal, APW, MRSWarranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 19 SITC of WALL Mounted Cross Connect Equipments12U x 600 x 500 Rack - Front Glass Door with Cam Lock - Fan Unit of 90CFM / 230 Volt - 1no - 6 Way 5A PDU, along with input Cable - 1no . Hardware packet of 20-3 No.,Make: Tata, Vertiv, Netrack, Valrack, Rittal, APW, Warrenty: 03 (Three) Years onsite comprehensive OEM warranty with parts and service. 20 SITC: 06 KVA Online UPS (1-ph input, 1-ph output) System with 10080 VAH (Min) Back-up Battery, Rack, Links, Cables & Other Accessories.Technology: Digital Signal Processing (DSP) controlled Microprocessor based technology true On-line, Hot-Standby Mode, Parallel Redundant Mode or Load Sharing Mode (1+1) configuration enabled; Input: 1-phase, 220/230/240V, 176 ~ 280 Vac (full load) ; 80 ~ 175 Vac (50% ~ 100% load), >0.99PF (full load), 50Hz ± 5Hz, Current Harmonic Distortion <3.0%; Output: 1-phase, 220/230V/240V ± 1%, > 0.90PF (full load), 50 Hz ± 0.1Hz; Harmonic Distortion (input current): < 3% (linear load); Crest factor: 3:1; Efficiency (AC/DC) Overall is (Online Mode) >=93% at full load; Operating Temperature: 0 ~ 55°C; Relative Humidity: 5 ~ 95% (non-condensing); Battery: SMF, 12 V, Mono Block batteries. The UPS battery shall be of Advanced Glass Mat Valve Regulated Sealed Lead Acid Battery Construction type (AGM or VRSLAB) in ABS Flame Retardant (UL94V-O) grade (UL 2436) spill containment casing to meet UL 62368-1/IEC 62133 or equivalent standards type to obtain a full rated load battery backup, standard FR DC Cable; Battery set: Complete with self standing cubicle or cabinet; Certification: CE, BIS; Type Test Report: ISO 9001, ISO14001,OSHAS18001;Display: LCD display and LED indicators;Separate Battery bank with accessorised. Including Inbuilt/Separate Isolation Transformer & necessary Earthing arrangement. 06 KVA 1Ø/1Ø (Phase input/output) with 10080 VAH (Min) Battery Backup or equivalent VAH or Higher, DC BUSBAR VOLTAGE ±192/±240; 12V SMF Battery, with MS-Rack, Interlink Nyvin Cable, Connector, Special battery terminal insulation cover and other accessories.Make: Schneider, APC, DELTA, Vertiv, Eaton, Numeric, Hitachi, Avo, Orion; Make Battery: Amararaja-Quanta/Exide, Model: Rack Mount Only.Warranty: 03(Three) years on UPS & 03(Three) years on Battery onsite warranty with parts and service. 21 SITC of: 1kVA (1.0/(168) (KVA/VAH)) Line-Interactive UPS having minimum technical specification:1.0VA /600 Watt or Higher Line Interactive Micro Processor Controlled UPS; Technology: IGBT-PWM; Type of battery: SMF-VRLA confirming to JISC-8702 Pt 1,2 &3; Rated Output (Volt): Single Phase Quasi-Sin-wave 230 V AC, 50 Hz; Degree of protection: IP 20; Inverter Efficiency (%): > / = 70%; Total harmonic distorsion (%): < / = 40%; Input (Volt): Single phase sinewave(160-280v); Switching over time (Mili sec): Maximum 10 milli seconds; Overload Time (Minutes): > / = 10 minutes; Load power factor: > / = 0.6; Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode: 230 Volts +/-15%, 50 +/-3 Hz; Overload (%): >/=10%; Variation in output voltage in battery mode (%) (UPS output voltage in battery mode): 230 Volts +/- 10%; Variation on output frequency in battery mode (Hz):