Tender For Composite tender for water supply scheme Chuker adjoing areas under Capex- 1 Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleare 2 Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed 3 All Kinds of soil. 4 Ordinary Rock 5 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 6 Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:.: All kinds of soil : 7 Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil : 8 Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil : 9 Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : 10 Providing and laying hand packed stone soling 50 mm nominal size/ boulder filling including filling, spreading, dressing,ramming, all leads lifts and all carriages complete. 11 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 12 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 14 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) 15 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 16 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 17 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 18 Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein. 19 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works upto plinth level 20 Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) 21 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works above plinth level upto floor V level 22 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 23 Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 24 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) 25 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 26 In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. 27 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 28 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. 29 Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 30 Riveted and bolted 31 Welded 32 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge.Made of G.I. wire of dia 4 mm 33 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 34 Centering and shuttering including strutting, propping etc. and removal of form for: 35 Foundations, footings, bases of columns etc. for mass concrete. 36 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 37 Lintel, beams, plinth beams, girders, bressumers and cantilevers. 38 Suspended floors, roofs, landings, balconies and access platforms. 39 Columns, pillars, piers, abutments, posts and struts. 40 Edges of slabs and breaks in floors and wallsUnder 20 cm wide 41 Stairs (excluding landings) except spiral staircases. 42 Arches, domes, vaults upto 6 m span 43 Extra for arches, domes, vaults exceeding 6 m span 44 Extra for shuttering in circular work: 45 Foundations, footings, bases of columns etc. for mass concrete. 46 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 47 Lintel, beams, plinth beams, girders, bressumers and cantilevers. 48 Suspended floors, roofs, landings, balconies and access platforms. 49 Edges of slabs and breaks in floors and wallsUnder 20 cm wide 50 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured).Suspended floors, roofs, landings, beams and balconies (plan area to be measured) 51 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) 52 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand) 53 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level 54 Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washerscomplete. 0.50 mm thick with zinc coating not less than 275 gram/m2 55 Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washerscomplete. 0.63 mm thick with zinc coating not less than 275 gram/m2 56 Providing and fixing of 0.5mm color GS sheet soffit boarding including backing, supports etc., complete 57 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, raftersand trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2 58 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, raftersand trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gram/m2 59 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 60 M.S. tube 61 Supplying and fixing rolling shutters of approved make, made of required sizeM.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover 62 Providing and fixing balls bearing for rolling shutter 63 Providing and fixing plained eaves boarding. 64 300x40 mm (nominal size) 65 250x32 mm (nominal size) 66 Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.(1 kg of water proofing material in 50 kg of cement) 67 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primer 68 Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 69 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angles 40x40x6mm for diagonal braces 70 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade (two or more coats on new work). 71 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fastenersshall be paid for separately): First class kail wood 72 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fastenersshall be paid for separately): Second class kail wood 73 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class Kail wood (35mm) 74 Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete. With Galvanized M.S. Wire gauge with wire of dia 0.63 mm With 2nd class teak wood beading 62x19 mm 75 Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class Kail wood (35mm) 76 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (35mm thick)Second class kail wood 77 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size includingnecessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as perarchitectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)For fixed portion 78 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) 79 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer- in-charge. (Cost of aluminum snap beading shall be paid in basic item).With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) 80 15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 4 ( 1 cement : 4 fine sand) 81 12mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand) 82 12mm Cement plaster finished with a floating coat of neat cement of mix:1 : 4 ( 1 cement : 4 fine sand) 83 12mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 3 ( 1 cement : 3 fine sand) 84 Providing and fixing of 2mm MS sheet boardingincl supports etc complete job 85 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 86 Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm 87 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 88 Providing & fixing PVC soil waste and vent pipe. 89 100mm 90 75mm 91 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. 92 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 93 Providing and fixing brass bib cock of approved quality. 94 15mm dia nominal bore. 95 Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 96 Providing & fixing of 50 litre capacity gyser of approved quality (venus make or equivalent). 97 Providing & fixing Lighting points in 1.5 sqmm multistrand PVC wire to be laid in conduits including providing & fixing of 5-A switches complete. 98 Providing & fixing heating points in 2.5 sqmm multistrand PVC copper wire to be laid in conduits including providing & fixing of 16-A switches complete. 99 Providing & fixing of 1200mm sweep ceiling fans complete with accessories including dimmer of ISI mark complete. 100 Providing & fixing of Exhaust fan in 1.5 sqmm stand wire to be laid in conduits complete. 101 Providing & fixing of 16-A MCB of Indocap complete. 102 Providing & fixing of PVC under drainage laterals with specifications conforming to IS-4985 & IS-15801, 8mm thick fabricated out of approved make with nominal dia of 9mm perforations as per design of bed provided at 60 degrees along with PVC Tees and end caps grouted in concrete, the pressure rating of 10kg/sq cm 103 50 mm dia 104 75 mm dia 105 Providing & fixing MCB distribution box 10 way main double door system. 106 Providing/ supply of thermocol to be laid under matting and cutting into desired dimensions including all sorts of carraige upto site. (12mm) 107 Providing/ supply of Excel Matting upto site of workand cutting into desired dimensions including all sorts of carraige as per Engineer Incharge 108 Providing/ fixing of curtains standard size of standard material including all fixtures like hooks/ring/ rods curtain holder etc (complet job) as directed by Engineer Incharge 109 Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50 mm thick with 20mm nominal size stone aggregate. 110 Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with: Makrana White Second quality 16 mmMakrana White Second quality (16mm) 111 Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. 112 Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) 113 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface 114 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 115 1 mm thick 116 2 mm thick 117 Distempering with 1st quality Acrylic/oil bound washable distemper (ready-made) having VOC content less than 50 grams/litre of approved manufacturer and of required shade and colour complete as per manufacturers’ specifications, one or more coats on old work 118 Providing and fixing aluminium handlesfor door stopper ISI marked anodised ( anodi coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and sahde with necessary screws etc complete 119 125mm size 120 100mm size 121 Providing & fixing aluminium hanging floor door stopper ISI marked annodized ( Anodic coating not less than grade AC 10 as per IS-1868) transparent or dyed to required colour or shade with nuts and screws etc. complete (Single rubber stopper) 122 15mm Cement plasteron the rough side of single or half brick wall of mix: 1: 6 mix (1 cement : 6 fine Sand). 123 Providing and fixing aluminium tower bolts ISI marked (anodised anodic coating not lees than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessaryscrews etc complete 124 150x10mm 125 100x10mm 126 Providing & fixing aluminium sliding door bolt ISI marked annodized (Anodic coating not less than grade AC 10 as per IS-1868) transparent or dyed to required colour or shade with nuts and screws etc. complete (300x16mm) 127 Providing and fixing Salem Stainless Steel A lSI 304 (18/8) kitchen sink as per I.S. 13983 with C.l. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board 510 x1040mm Bowl depth 250mm 128 Applying priming coat: With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works 129 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete 130 Providing & fixing MS grill of required pattern in frames of windows etc. with Ms flat,square or round bars etc. including priming coat with approved steel primer. All complete. (fixed to steel windows by welding) 131 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In all colours, shades, except White, Ivory, Fume Red Brown 132 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete 133 On steel work 134 On concrete work 135 Providing and fixing G,I pipes (B medium) complete with G.I fittings excluding trenching and refilling etc., (external work) for rising main and delivery main of OHT 136 15 mm dia. nominal bore 137 20 mm dia. nominal bore 138 25 mm dia. nominal bore 139 40 mm dia. nominal bore 140 50 mm dia. nominal bore 141 65 mm dia. nominal bore 142 80 mm dia. nominal bore 143 100 mm dia. nominal bore 144 150 mm dia. nominal bore 145 Providing and fixing G.I. pipes complete with G.I. fittings excludingtrenching and refilling etc. (external work)(Light) 146 15 mm dia. nominal bore 147 20 mm dia. nominal bore 148 25 mm dia. nominal bore 149 40 mm dia. nominal bore 150 50 mm dia. nominal bore 151 65 mm dia. nominal bore 152 80 mm dia. nominal bore 153 100 mm dia. nominal bore 154 Renewing glass panes, with wooden fillets wherever necessary : Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm) 155 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 156 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown 157 Supply and filling of filter media from approved source - Gravel (Graded gravel - size ranging from 2.0mm to 40.00 mm) in filter beds. Including all carriages, complete job 158 Supply and filling of filter media from approved source - Sand (Coarse filter sand - in filter beds. Including all carriages, complete job 159 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 160 Providing and fixing of MS surface boxes (0.75x0.75x0.75) of 6mm thick plate for sluice valves. The job includs fixing of angle iron frame legs in cement concreate 1:2:4 mix with locking arrangements complete. 161 Providing/ fixing of 250MM and MS pipe including manufacturing fabricating installing at site fixed as a drum for providing different connections including installing of same on MS stands and fixing of outlet flanged connections of different dia including fixing a common supply main up to drum including all carriage complete. 162 Supplying and fixing of 25mm dia. medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 163 Providing and carrying out wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl. cost of conduit) 164 Providing and carrying out wiring for heating points with 4.0 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, modular combinedS&S 16Amp along with modular plate, suitable GI box and earthing the point with 2 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl cost of conduit) 165 Providing and carrying out wiring for twin control light points with 1.5 sq. mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, two way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl. cost of conduit) 166 Providing and carraying out circuit/ sub main wiring along the earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, two way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl. cost of conduit) 167 2x2.5 sq. mm + 1x2.5 sq.mm earth wire 168 2x4 sq. mm + 1x4 sq. mm earth wire 169 Supply and fixing single pole 5 A to 32 A rating, 240 V, 10 KA, C miniature circuit breaker suitable for inductive load in the MCB DB complete with testing commissioning and connections etc., as required 170 Supply of 24 Watt LED slim aluminium panel surface type complete in all respects 171 Installation of exhaust fan in the existing opening including making good the damaged connection testing commissioning as required 172 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 173 Supplying and fixing double pole 63 Amp 240V, 10 kA, C curve, miniature circuit breaker suitable for inductive load in MCB DB complete with connections, testing and commissioning etc. as required. 174 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 175 Supply of 200 mm nominal sweep Exhaust Fans including shutter from outside complete.Confirming to relevant Indian Standards 176 Supplying and fixing 12-way double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 177 Providing, fitting and testing of LED flood light IP65 30W rating to pre-wired electric points on the outside of the Filter House building. 178 Providing and laying of armoured cable 95mm, 3.5 core for main service line of reputed make in P.V.C pipes of required dia to accommodate the service line including bends etc., from main transformer to the main panel board including copper thimbles, earth work excavation and filling for laying of cable complete. 179 Providing and fitting at site 3-phase, Voltage stabilizer of following ratings, oil emersed, of standard make and quality including accessories as required. The job includes making of connections with main panel board and service line. To be paid in fitted and finished form after testing on full load capacity, complete job. 180 25 KVA 181 30 KVA 182 Providing and fitting of panel board with angle iron supports and A.C. sheets for fixing of MCCB, change over switch, bus bars etc. The job includes nuts bolts and embedding of supports in cement concrete blocks complete job. 183 Providing and fitting of: 184 100 Amp. 4 pole Change over of reputed make 185 200 Amp. 4 pole Change over of reputed make 186 32 Amp-Copper bus bar 187 32 Amp-Copper bus bar 188 100 Amp MCCB 189 63 Amp MCCB 190 16 Amp MCCB 191 3-phase indicator points 192 3-phase voltmeter and Amperemeters 193 Bleach and backwash tank pump panel board fittings starter (to be paid separately) 194 16 Amp MCCB 195 6 Amp MCCB 196 3-phase indicator points 197 3-phase voltmeter 198 3-phase Amperemeters 199 Air blower pannel board fittings starter (to be paid separately) 200 16 Amp MCCB 201 3-phase indicator points 202 3-phase voltmeter 203 3-phase Amperemeters 204 Alum tank panel board fittings starter (to be paid separately) 205 16 Amp MCCB 206 3-phase indicator points 207 3-phase voltmeter 208 3-phase Amperemeters 209 Rotatory bridge panel board starter (to be paid separately) 210 16 Amp MCCB 211 6 Amp MCCB 212 3-phase indicator points 213 3-phase voltmeter 214 3-phase Amperemeters 215 Providing, fitting, testing and commissioning of following items for Flash Mixer: 216 Mixing device with reduction gear system 217 3-phase Electrically driven motor: 218 1.0 HP 219 Foundation Base plate 220 Starter along with necessary wiring upto motor 221 Providing, fitting, testing and commissioning of following itemn for Alum Dosing Unit- 222 Mixing device with reduction gear system. 223 3-phase electrically driven motors: 224 1.0 HP 225 Foundation / Base plate 226 Starter along with necessary wiring upto motor 227 P.V.C outlet, overflow system with fittings upto point of application 228 50 mm dia Service water piping. 229 150 mm drain outlet 230 Constant dozing unit with time device 231 Manually operated hoist 232 Providing, fitting, testing and commissioning of following itemns forChlorine Dosing Unit- 233 Mixing device with reduction gear system. 234 3-phase electrically driven motors: 235 1.0 HP 236 Foundation / Base plate. 237 P.V.C outlet, overflow system with fittings upto point of application. 238 Starter along with necessary wiring upto motor 239 50mm dia service water piping 240 150 mm drain outlet 241 Constant dozing unit with time device 242 Providing fitting, testing and comissioning ofair blower standard make ISI mark capable of providing compression @ 0.35 kgs/sqcm coupled with suitable 3 phase induction electric motorcomplete with auxiliary pipe system upto filter beds with pressure guage, Nozzles, foundation block, base plate, air check valve , non- return valve, Starter etc 243 4.2 KLPM Air blower with 5.0 HP Motor. 244 Up Wash Arrangements Supply installation and successful testing and commissioning of mono block pumping unit standard make ISI mark coupled with 2 phase induction motor with appropriate pumping capacity so as to fill the tank within the max. of 2 hours with nominal dynamic head of 25m along with all accessories like foot valves, non- return valves, foundation block, base plate, suction pipe, suitable rising main with nominal dia 50mm (class-B)with heavey dutyvalves and other accessories required for the job. 245 Pumping unit with 5.0 HP Motor. 246 P/F testing and commissioning of MS Rotating Desludging Bridge comprising of following items:Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete for the Installation Testing and Commissioning of Half Bridge with Central Drive mechanism, scrapper and churners for required dia Clarifer. 247 Welded 248 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) 249 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete 250 On steel work 251 Central axle turn table with double bearing and guide for incoming cable. 252 Peripheral drive assembly with following motors, gear box, rollers, drive trolly (60:1 reduction gear box). 253 Pumping unit with 2.0 HP Motor. 254 Pumping unit with 5.0 HP Motor. 255 Starter along with necessary wiring upto motor 256 Flocculator drive assembly with crown wheel, pinion sets, reduction gear (40:1) with motors complete job. 257 1.0 HP 258 Incoming cable, telescopic electric pole with rotary current collector 259 Providing/ Fixing, installation, successful commissioning of double flanged MS pipes/specials to be fabricated from MS tube heavy quality nominal thickness 6mm, conforming to relevant Indian Standard IS-1239 and/or IS 1161 read with up to date amendments. The pipe material should be of standard quality and must withstand all the anticipated design pressure ratings.The work should be leakproof and should be painted with anti corrosive red oxide primer. Complete Job. 260 Providing & fixing of 0.63mm thick PGI sheets at construction joints including all leads and lifts complete job as directed by Engineer-in-charge 261 Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered).Depth exceeding 3 m but not exceeding 4.50 m 262 Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered). 263 Depth exceeding 1.5 m but not exceeding 3 m 264 Providing and laying S&S Centrifugally Cast (Spun)/ Ductile Iron Pipes conforming to IS : 8329 265 100 mm dia Ductile Iron Class K - 7 Pipes 266 150 mm dia Ductile Iron Class K - 7 Pipes 267 200 mm dia Ductile Iron Class K - 7 Pipes 268 250 mm dia Ductile Iron Class K - 7 Pipes 269 300 mm dia Ductile Iron Class K - 7 Pipes 270 350 mm dia Ductile Iron Class K - 7 Pipes 271 400 mm dia Ductile Iron Class K - 7 Pipes 272 Laying and fitting of G.I. pipes (all classes) complete excluding cost of pipes, fittings and Earth work. 273 15 mm dia. nominal bore 274 20 mm dia. nominal bore 275 25 mm dia. nominal bore 276 40 mm dia. nominal bore 277 50 mm dia. nominal bore 278 65 mm dia. nominal bore 279 80 mm dia. nominal bore 280 100 mm dia. nominal bore 281 150 mm dia. nominal bore 282 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 283 20 mm nominal bore 284 25 mm nominal bore 285 32 mm nominal bore 286 40 mm nominal bore 287 50 mm nominal bore 288 65 mm nominal bore 289 80 mm nominal bore 290 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately). 291 20 mm dia 292 25 mmdia 293 50 mm dia. 294 80 mm dia. 295 100 mm dia. 296 Providing/Fitting and fixing ,successful testing ofdouble flanged non rising spindle with hand wheel NRV C.I Sluice valveKirloskar make heavy duty of PNI rating ( male/ female) with R.I Cloth nuts bolts includesall leads and lifts , andcost of Spun yarn etc complete job . 297 100mm dia NRV 298 150mm dia NRV 299 Providing & fixing of MS bends of required dia and Tees including welding charges, carriage of welding machine upto site of work and fixing at site including cost of rubber gaskets/washers/nuts & bolts etc as complete job. 300 Providing fixing of MS lid cover of 0.60x0.60m with angle iron frame including locking arrangement and all carraiges complete. 301 Providing and fixing of MS ladder of required height made of 50x50x6mm angle section with 40x40x5mm thick treads etc all work as complete job. 302 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 303 25 to 40 mm nominal bore 304 50 to 80 mm nominal bore 305 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). 306 100 mm dia.Class I 307 150 mm dia.Class I 308 200 mm dia.Class I 309 Providing and fixing D.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Confirming to IS:14846 read with latest amendments. 310 80 mm dia. Class 1 311 100 mm dia. Class 1 312 125 mm dia. Class 1 313 150 mm dia. Class 1 314 200 mm dia. Class 1 315 250 mm dia. Class 1 316 300 mm dia. Class 1 317 350 mm dia. Class 1 318 Providing and laying D.I. standard specials such as tees, bends, collars, tapers, caps etc. suitable for flanged jointing as per IS : 9523 (as per site requirement) 319 Up to 300 mm dia. 320 Over 300 mm dia. 321 Providing and fixing of MS flanged joints (12mm thick) to double flanged GI/DI pipes including cutting of pipes, welding charges, cutting of flanges, rubber gasket, bolts, nuts including testing of joint and all sorts of carriages. Complete Job. 322 80 mm dia. pipe 323 100 mm dia. pipe 324 125 mm dia. pipe 325 150 mm dia. pipe 326 200 mm dia. pipe 327 250 mm dia. pipe 328 300 mm dia. pipe 329 350 mm dia. Pipe 330 Laying in position centrifugally cast (spun) iron S&S or flanged pipes (excluding cost of pipe) 331 Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket. 332 100 mm dia pipes 333 150 mm dia pipes 334 200 mm dia pipes 335 250 mm dia pipes 336 300 mm dia pipes 337 350 mm dia pipes 338 400 mm dia pipes 339 450 mm dia pipes 340 Installation, testing and commissioning of pre wired fluorescent fitting/ compact flurescent fitting of all types, complete with all accessories and tube/ lamp etc., directly on ceilling/ wall, including connections with 1.5 sq. mm FLRSPVC insulated, copper conducter, single core cable and earthing etc., as required. 341 Extra for pre finished nosing to tread of steps of marble stone 342 Extra marble stone flooring in tread of steps and risers using single length upro 2 mtr 343 Grassing with section no. 1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supply of good earth if needed (the good earth shall be paid separately) in rows 5cm apart in either direction 344 Spreading of sludge, dump manure or/ and good earth in required thickness as per direction of officer incharge (cost of sludge dump manure or/ and good earth to be paid separately 345 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):KD/ Silver wood 346 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.KD/ Silver wood 347 Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :KD/ Silver wood 348 Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. completePopular wood 349 Providng and fixing panelled or panelled and glazed shutters for doors , windows and clerestory windows including ISI marked M.S pressed Butt hinges bright finsihed of required size with necessary screws35mm thick silver wood/K.D 350 Providing and fixing of 2mm MS sheet boardingincl supports etc complete job 351 Supply and fixing/installation including succesful testing and commissioning alongwith trial run for a period of three (03) months GRP Hot Compressed Moudling SMC (Sheet Moulding Compound) tanks with certificate as per ISI Specifications and in accordance with (IS: 14399 -1996 Part I & II). In addition to the storage capacity, the tank should have a free board of minimum 150mm. The tank shall be assembled/constructed using GRP/SMC panel of 1 m x 1 m, 1 m x 2 m or 1m x 0.5m panel as per site requirement. The Dimensions of the tank shall be chosen as per site requirement/design/drawing of the steel staging/platform. The roof of the tank should have panel of size 1m x 1m or as per site requirement, one manhole should be provided on the roof of the tank with double lip construction and proper locking arrangement. The panel should withstand Hydro Static Pressure of at least 4 times the working load and should be provided with HUG nut bolts/washers; Rubber foam gasket cover washer, cleats, including air vents, necessary support system of appropriate size for the roof top panels. The tank shall be constructed as per manufacturers instructions and met all ISI standards. All M.S. Parts inside/outside should be painted with anti-corrosive paint to avoid rust. The tank should have ladders inside and outside, provision of inlet / outlet / overflow / drain etc. complete job. The rates include all Freight, lead, lift to any distance as a loading, unloading, all taxes (GST), charges, all L&M, T&P as a complete job. Nothing extra will be paid whatsoever the case may be, on turnkey basis.90.800 KL (20000 Gallon) 352 Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered).Depth not exceeding 1.5 m. 353 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. 354 Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. 355 Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified grade concrete mix, diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embeded in the pile cap etc. all complete including removal of excavated earth with all lifts and leads(Length of pile for payment Shall be measured from top of shoe to the bottom of pile cap) By percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, 356 450 mm dia piles [M25] 357 450 mm dia piles [M30] 358 450 mm dia piles [M35] 359 500 mm dia piles [M25] 360 500 mm dia piles [M30] 361 500 mm dia piles [M35] 362 600 mm dia piles [M25] 363 600 mm dia piles [M30] 364 600 mm dia piles [M35] 365 750 mm dia piles [M25] 366 750 mm dia piles [M30] 367 750 mm dia piles [M35] 368 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor pile method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer-in- Charge. Single pile upto 50 tonne safe capacity Initial test (Test Load 2.5 times the safe capacity) 369 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor pile method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer-in- Charge. Single pile upto 50 tonne safe capacityRoutine test (Test Load 1.5 times the safe capacity) 370 Providing and fixing D.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Confirming to IS:14846 read with latest amendments. 371 80 mm dia. Class 1 372 100 mm dia. Class 1 373 125 mm dia. Class 1 374 150 mm dia. Class 1 375 200 mm dia. Class 1 376 250 mm dia. Class 1 377 300 mm dia. Class 1 378 350 mm dia. Class 1 379 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).First class kail wood (35mm) 380 Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment) 381 Dry random rubble masonry with hard stone in foundation and plinth: With bond stone (Using Quarry) 382 Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with:Cement mortar 1:6 (1 Cement : 6 coarse sand) 383 Carriage of materials by mechanical transport including loading, unloading, stacking of materials - SAND: 384 5 Km 385 Beyond 5 km upto 10 km per km 386 Beyond 10 km upto 20 km per km 387 Beyond 20 km per additional km 388 Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Aggregate below 40mm : 389 5 km 390 Beyond 5 km upto 10 km per km 391 Beyond 10 km upto 20 km per km 392 Beyond 20 km per additional km 393 Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Aggregate 40mm and above : 394 5 Km 395 Beyond 5 km upto 10 km per km 396 Beyond 10 km upto 20 km per km 397 Beyond 20 km per additional km 398 Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Steel/ CGI Sheets: 399 5 Km 400 Beyond 5 km upto 10 km per km 401 Beyond 10 km upto 20 km per km 402 Beyond 20 km per additional km 403 Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Cement: 404 5 Km 405 Beyond 5 km upto 10 km per km 406 Beyond 10 km upto 20 km per km 407 Beyond 20 km per additional km 408 Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Bricks: 409 5 Km 410 Beyond 5 km upto 10 km per km 411 Beyond 10 km upto 20 km per km 412 Beyond 20 km per additional km 413 Carriage of materials by manual means including loading, unloading, stacking of materials- (Sand) 414 Ist 50m 415 Beyond Ist 50m 416 Carriage of materials by manual means including loading, unloading, stacking of materials- Aggregate Below 40mm 417 Ist 50m 418 Beyond Ist 50m 419 Carriage of materials by manual means including loading, unloading, stacking of materials- Aggregate 40mm and Above 420 Ist 50m 421 Beyond Ist 50m 422 Carriage of materials by manual means including loading, unloading, stacking of materials- Steel/CGI Sheets 423 Ist 50m 424 Beyond Ist 50m 425 Carriage of materials by manual means including loading, unloading, stacking of materials- Cement 426 Ist 50m 427 Beyond Ist 50m 428 Carriage of materials by manual means including loading, unloading, stacking of materials- Brick 429 Ist 50m 430 Beyond Ist 50m 431 Mechanical and Electrical 432 Supply, Installation, Testing & Commissioning of Non-clog Pumping Unit as per IS 5600 at Raw Water Stage. PUMP: - Type of pump:NonclogOpen wellSubmersible Vertical Pump• Solid Handling Capacity: 20mm (Minimum)• Quality of water:Raw water to be handledMATERIAL OF CONSTRUCTION: • Pump Casing: Cast Iron • Impeller: Stainless Steel • Pump Shaft : Stainless Steel • Motor Body: Cast Iron • Sealing :Dual mech. seal The bowl plate shall be provided with name plate depicting all specificationsPump- MOTOR: -15000GPH and 160M Head, with corresponding HP • Type : Squirrel Cage 3-Phase Induction Motor• Rating : Suitable for above parameter • Method of starting: Star – Delta. • Frequency : 50Hz + 3% • Voltage : 415± 6 %, -15%• Class of insulation: Suitable for above rating. Manufactures Test Certificate to be apended abd detailed specification as per cluase 2 ofof SBD. 433 Delivery pipe and Delivery Manifold line:- Providing/supplying and fitting of G.I flanged Rising Main/ delivery manifold at site, 100mm. The Pipe shall be hot dip Galvanized, class B and C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) “REDUCERS IF ANYALSO INCLUDED” Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The main technical specifications of the pipe are given here under: 125 mm dia GI rising main along with Delivery Manifold connectingpumping units, valves , tail pieces between valves, flanges, gaskets, nuts bolts, all inclusive as per the site requirement. 434 Providing and fitting ofDuctile Iron double flanged, Slanted seat swing check valve( NRV) Size: 80mm, any reducer to be made by the executing firm PN: 1.6/16as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges (Table flanges) perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. 435 Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves Size: DN80,any reducer to be made by the executing firm PN:1.6/16as per IS14846 for regulating the water supply outside the pumping units . The body and bonnent of the valve shall be of ductileiron, wedge with fully vulcanized EPDM rubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating(approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges (Table flanges) perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. 436 Steel work for Gantry ISMB 100 and PUMP Bay Base Frame ISMB100in built up tubularfor Gantry Columns trusses, construction of liner etc. including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. The drawings and Dimensions for Gantry/ Pump BaseFrame will be provided by Site In Charge at the time of execution of job 437 Providing and laying in position cement concrete of specified grade(1:2:4)( 1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size) including curing & including the cost of centering and shuttering. 438 Painting of steel structure by way of providing and applying of metal primer Red oxide andenamel paint of required shade and colour after surface cleaning by using emery paper of proper grade and grit size 439 Providing / fitting of geared / hand railing type - Plain Travelling Trolley of modular construction, fabricated out of rolled steel plates, pivot mounted, runners mounted on roller bearings for easy movement of wheels, with wide range for beam width selection up to ISMB 150/200 440 Supply of heavy duty hand break trolley ND 2500 Kgs capacity with easy handling to be used for lifting/shifting of electrical/Mechanical gadgets like voltage stabilizer, VT bowl, Motor etc. From loading site to pump station. Capacity:2.5 ton Mode l:DF 550x1100 Size:550x1100mm 441 Providing, installation andtestingof manual type triple spur gear chain pulley block along with monorail gearedtravelling trolleyhaving following features Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain:-The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation.Load chain wheel:- the load chain well should be double ball bearing supported andSpecially designed, perfectly machined wheel providing correct grip of load chaintomakes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below : Make = Reputed make Capacity = 3 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M 442 Fabrication, Providing and fitting ofModular motorcontrol panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories(operating capacity rating 50Hp) as under: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity copper with current density of suitable rating for 200 Ampere. All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards. b) Main Circuit Breaker (Incomer MCCB): Qty. = 02 No. of poles= 4 Pole Current Rating= 100A Rated operational voltage = 415 V + 15 % Rated frequency= 50+/-3%Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 50KA Type of release= Thermal-Magnetic Overload protection = 0.8 – 1×ln adjustable Short-circuit protection = 6-10×ln adjustable. Current rating = As per requirement c) Change over Switch: Qty. = 01 No. Rating= 100A Type =Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hz. d) Motor Back-up Protection MCCB: Qnty = 2 No No. of poles = 3P Current Rating = 100A Rated operational voltage =415 V +15 % Rated frequency = 50 + 3% Hz Ambient temperature= 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 50KA Current rating =100A e) starters:-= Fully automatic star delta(50HP) Power Specification -----3 phase, 415± 15% v &50 HzContactors : reputed makeLine Contactor -----AC3 100 ADelta Contactor --- AC3100 A Star Contactor -----AC3 100 A Timer ----- Star Delta ElectronicOverload relay – direct/CT operated (35-75A range)Coil Voltage : 220/240V Qty ----- 2 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty.= 1 No. No. of poles = 4P Current Rating= 63A. Rated operational voltage =415 V + 15 % Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) =25KA g)Stabilization unit Qnty---01 no Rating---- 1 KvA single phase automatic voltage stabilizer Input :90V-300Out Put : 220/240 ( as per coil voltage of contractors) Enclosure--- to be housed within the cubical panel in separated chamberwith additional meter , LEDfitted outer side MCB DP ---10A----1nos h)ProtectionDetails:Motor Protection Relay including other related accessories like single phase preventer relay, timer relay , overload-under load, phase difference etc. Display -----LED/LCD Compact motor protection relay Note: all setting is to be controlled at display.Qnty :01 nos) Protections : •Flush Mounting with display •Last trip data recording•Protections: - Thermal Overload with pre- alarm - Short Circuit - Earth fault - Phase loss, Unbalance, Phase reversal - Under Current, Over Load - Prolong starting, Locked Rotor. -Single phase protection- Single Phasing condition- Phase Reversal condition- Phase Unbalance condition-Modes of Operation i) Auxiliary ProtectionEarth Fault Relay -----3 phase Earth fault, ground fault moduleType -----GFRange 100-200A MCB ----- MCB SP , 10A (10 Ka)j) Metering Details: ● Incomers (Panel Mounted)(a) Multi-Function MetersLCD Display (1 No) Voltage of each phase , Current of each phase 3ø power (Active, Apparent) , 3ø Power factor Frequency , Energy (b) Analog voltmeter S/S operated (1 No)● (b) Outgoing (Analog voltmeter (0-500) S/S operated (1Nos) . Analog Ammeters 0-200 Amp(2Nos)for both starters Each outgoing with S/S CT operated. 443 Providing, fitting, testing and commissioning of 250Amp MCCB. Type -----Front Operated micro processor release type on load 4 pole Qty ----- 1 Nos No. of poles ----- 4Current Rating…..250 AmpRated operational voltage----- 415 V AC± 15%Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking cap at(415 volt A C , 50 Hz ) ----- 50kAType----- Microprocessor controlThe MCCB shall be housed in a panel fabricated out of 14SWG; duly given two coats of grey color powder coating, the door of the panel shall have a locking arrangement. The panel shall be installed on angle/channel structure, as per the direction of the site Engineer. 444 Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below:Rating: 100KVA Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling: Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion: virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations. Load: Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications. Rating: 100KVAManufacturers test certificate to be appended. 445 Supply , installation , commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer Rating: 200 KVA HT Transformer(copper), 3 phase (Level 2). Type of cooling:ONAN. Operating conditions: Input=11000 volts Output =433 volts AC supply in 3- phase. Terminals: Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge.Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality copper wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments.NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. Manufacturers certificate be appended 446 P/F/I/T of 50Sqmm3.5-core Aluminiumarmoured cable- 100m from HT Transformer to the Raw water station, service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. , and 35-SQmm copper single core 200m for internal connections from stabilizers to panels and to motors etc, the job includes thimbling , tapping, nuts and bolts etc. including 5No. tubular poles(ST410) complete. 447 Supply, installation, erection of 9 mtrs long H.T pope of specifications ST- 410 (sp-33) for stage 1st and 2nd . The job further includes drilling of holes for installation of various accessories fitting of insulators , brackets etc complete .wherever required the job further includes G.I wire earthing of pole as per REC standard. 448 Cement Bottoming 1:2:4 mix as per REC standards 0.5 cum/pole 449 Providing and fitting G.I Channel /Angle/ Flat /Riser of sizes including clamps. 450 Supply and installation of G.I V cross with top Bracket including clamps 451 Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. 452 Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation. 453 Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type. 454 Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320 mm. 455 Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) 456 Providing and fitting of 3x5/8” Galvanized nuts and bolts 457 Providing and fitting of Danger Plates with Clamps 458 Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices 459 Painting of poleswith Red oxide 460 Painting of poles with Aluminum paint 461 P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043 The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.Safe earthing electrode size:80 mm dia ,Length :2000 mm Back fill compound:30 kg 462 Stone pad (300mm x300mm x75mm) 463 P/L of ACSR conductor of size 0.05 as per the relevant IS standard 464 11 kV polymeric composite Disc Insulator 12 kV, Min failing load 45kN, Lighting Impulse 75kV Positive and 80 kV Negative, creepage distance 320mm 465 Providing and fitting of LT Distribution box for H.T transformer with MCCB For incomer and SFU for outgoing circuits. 466 Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete. 467 Providing, installation, testing and commissioning of outdoor type HT Trivecto-meter as per IEE Rule. Job includes grouting of legs in cement concrete as per site requirement. All cabling, earthing and allied accessories required to be provided by the firm. Moreover firm responsible for completing all sealingof PDD department and testing on load and no load at site. 468 CLEAR WATERSupply , installation , commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer Rating: 63 KVA HT Transformer(copper), 3 phase (Level 2). Type of cooling:ONAN. Operating conditions: Input=11000 volts Output =433 volts AC supply in 3- phase. Terminals: Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge.Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality copper wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. Manufacturers certificate be appended 469 Supply, installation, erection of 9 mtrs long H.T pope of specifications ST- 410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard. (in whole creation work all to be paid as per site usage) 470 Cement Bottoming 1:2:4 mix as per REC standards 0.5 cum/pole 471 Providing and fitting G.I Channel /Angle/ Flat /Riser of sizes including clamps. 472 Supply and installation of G.I V cross with top Bracket including clamps 473 Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. 474 Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation. 475 Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type. 476 Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320 mm. 477 Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) 478 Providing and fitting of 3x5/8” Galvanized nuts and bolts 479 Providing and fitting of Danger Plates with Clamps 480 Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices 481 Painting of poleswith Red oxide 482 Painting of poles with Aluminum paint 483 P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043 484 Stone pad (300mm x300mm x75mm) 485 P/L of ACSR conductor of size 0.05 as per the relevant IS standard (to be paid as per site) 486 11 kV polymeric composite Disc Insulator 12 kV, Min failing load 45kN, Lighting Impulse 75kV Positive and 80 kV Negative, creepage distance 320mm 487 Providing and fitting of LT Distribution box for H.T transformer with MCCB For incomer and SFU for outgoing circuits. 488 Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete. 489 Providing, installation, testing and commissioning of outdoor type HT Trivecto-meter as per IEE Rule. Job includes grouting of legs in cement concrete as per site requirement. All cabling, earthing and allied accessories required to be provided by the firm. Moreover firm responsible for completing all sealing of PDD department and testing on load and no load at site. 490 P/F/I/T of 50-Sqmm3.5-core Aluminium armored cable- 100m from HT Transformer, service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. and 35-SQmm copper single core-200m for internal connections from stabilizers to panels and to motors etc, the job includes thimbling , tapping, nuts and bolts etc. 491 P/F/I/T of 50 Sq mm AB(HT) Cable (3x35+1x70 sqmm) XLPE (11 kV , 3C+Earth) (to be used as per site) 492 Heat Shrinkable Outdoor cable termination Kit 493 Providing & fittingof D-clamps for holding of cable with poles 494 Supply, Installation, Testing & Commissioning of MCCB, 250A, 4-pole, 3-phase 415 ± 15% volts., Frequency:50± 3% C/S., 50 KA breaking capacity. The MCCB shall be housed in a panel fabricated out of 14SWG; duly given two coats of grey color powder coating, the door of the panel shall have a locking arrangement. The panel shall be installed on angle/channel structure, as per the direction of the site Engineer. 495 Providing, laying & fixing of shock proof rubber mats with adhesive/bonding material on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications:Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. 496 Providing & laying of 10mm thick anti shock rubber flooring/mats of reputed make. 497 Providing/Fitting of 50 mm dia flexible convas sleeve/conduit for carrying cables of different sizes 498 Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 100mm 499 Fabrication, providing and fixing of 9ft x 5ft Platform for restingHV power transformer(Ist & 2nd stage) 5ft above from the ground level. The job includes P/F of required size nuts, bolts, all tools and tackles, transportation charges and skilled labour component. The requisite drawing and sections shall be provided by the site incharge 500 Providing & fixing of 11KV rating & of standard quality link set(Ist & 2nd stage). The same is to be fitted at the tapping point location. 501 Providing & fixing of sign plates fabricated out of MS sheets of size 1ft x 1ft to be fixed on each pole(Ist & 2nd stage). The job includes letter writing as 11KV Danger in red color on the sign plates. 502 Supply, installation, testing and commissioning of MCCB, 200A, 4-pole, 3-phase 415 ± 15% volts.,Frequency : 50± 3% C/S., 50 KA breaking capacity.The MCCB shall be housed in a panel fabricated out of 14SWG; duly given two coats of grey color powder coating, the door of the panel shall have a locking arrangement. The panel shall be installed on angle/channel structure, as per the direction of the site Engineer. 503 P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043 The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.Safe earthing electrode size:80 mm dia ,Length :2000 mm Back fill compound:30 kg 504 Painting of whole substation structure platform(Ist & 2nd stage).including channels, etc. in one coat of steel primer paint and two coats of water proof silver color paint. 505 Providing, installation, testing of power cable for working voltage up to and including 1100 volts; 300 mm square armoured aluminium 3.5 core cable 506 Supply, installation, testing and commissioning of Copper conductor power cable having the following technical specifications for connecting V.T units of clear water stationwith main control panel.(185mm2), single Core 507 Supply, installation, testing and commissioning of Copper conductor power cable having the following technical specifications for connecting V.T units of clear water stationwith main control panel.85sqmm, single Core 508 Providing of good quality convenience and utility items as per following detailsa) Providing of good quality bedding for night stay/Shift consisting of: -i) Mattress with warm cover size 6x3 (6Kg)- 02 Nos ii) Quilt with warm cover size 5x8 (6Kg)- 02 Nos iii) Pillows with covers - 02 Nos iv) Single bed warm blankets with one sided Fur- 02 Nos The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 Nos, Steel patella (utensil) 5ltrs 02 Nos, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 Nos each, steel glasses 06 Nos, steel Plates with large spoons and bowls 03 Nos each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermo-cool 15x12 along with excel matting of 15x12 size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 Nos, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 Nos), Link locks, 509 TOOL KIT For Maintenance : The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of: Providing of tool kit consists of following itemsDouble ended Spanner (Chrome plated) 02 sets complete Double ended Ring spanners chrome plated 02 sets complete Allen key set black finish 02 sets complete Combination Pliers insulated with thick C.A sleeve; size in mm 165, 210, 255each02 No. Long nose plier insulated with thick C.A sleeve; size in mm 165, 205each02 No. Side cutting plier insulated with thick C.A sleeve; size in mm 165, 205 make02 No. Insulated screw DriversBlade length Blade dia Tip dimensions Quantity In mmin mm in mm50 3 1.6 x 0.4 02 75 3 1.6 x0.4 02 100 3 3 x 0.4 02 1253.53.5 x 0.502 1503.53.5 x 0.5 02 200 44 x 0.6 02 3005 5 x 0.802 viii. Hammer with handle weight110 mg, 340 gm , 600 gm each1No. .ix. Heavy duty pipe Wrench length in mm - 200, 300, 600 each01 No. x. Electric Multimeter =1No xi. Digital multimeter1No. xii. Digital Clamp tester capable to measure up to 400A - 1 No. xiii. Hack saw frame with hack saw blade01 no. xiv. S-16 MXL, S- 16 H X L Socket Set (19 sockets + 6 Accessories)01 No. 510 Supply of portable size Grease Gun 511 Supply, installation of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate. The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO. 512 Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover.with 2-core 4 mm2 Cu (25 m)wiring as per site requirement along with other accessories like SS-Combine (02 Nos), 3-pin plugs etc of reputed make for proper fitment and installation of the item. 513 Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized Octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp.The job includes fabrication, providing and fitting of three arm GI structure at the top having 120˚ angle between arms and each arm having 15˚ inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2x2x6 (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7 in length. The complete job includes earthing in GI Electrode as per relevant IS Code. 514 Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.26 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120˚ - 170˚ Lumens: >12000 Operating Temperature: -20˚C to 60˚C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is properly fitted on the arm of the pole and connected to the copper wire as provided in the high mast pole. 515 Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit. 516 Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site in charge. 517 Providing & fitting oflighting points for( machine room , operators room,) as per site requirement in 1.5 mm² multistranded single core 1100 volts, pvc insulatedcopper conductor through pvcconduit pipe by way, switches, socket modules , regulators ,indicators, 08/10 watt LED lamps Surface light Make. .Included is cost on account of modular switch boards with the wooden frames as per site requirements 518 Providing fitting of heating points in 2.5mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit by way of p / f of 15 Amp switches, 6 pin socketon modularfittingas per site requirements. Heating points are to be connected from main control panel. All accessories required is to be provided by the firm 519 Providing and fitting of 9” x 9”exhaust fan with complete wiring in 1.5 mm cu wire through conduit and 6 A modular controlcomplete job. Make Providing and fitting of 9” x 9”exhaust fan with complete wiring in 1.5 mm cu wire through conduit and 6 A modular controlcomplete job. 520 Providing, fitting of Distribution Board of reputed make 4 way S P N single door powder coated sheet steel enclosure for surface mounting fitted with bus bar, DIN channel, neutral link and incoming contact. the above DB is to be provided /fitted with double pole 40 amp MCB for Main. 32 A for heating circuit & rest 3 of 16/6 amps each for premises luminary, auxiliary circuit of reputed make. Further job includes providing / fitting 4 mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit as service line from main panel as per site requirements. Connections should be made in such a way Lighting pointsis to be connected via automatic transformer by way of p/f switch socket arrangement with allied fixtures & and heating points to main panel. Job includes dismantling of existing damaged conduit , wires, conduit and cleaning the surface properly 521 Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal. 522 Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipment’s installed at site for stage 1st and 2nd.