Tender For Renovation Of Indra Park In Ward No. 14 Mc Hansi
Tender Value
42.32 Lakhs
Estimated cost
Bid Submission
04 Aug 2025
0 days left
EMD
84655
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
hansi → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Renovation of Indra park in ward no. 14 mc hansi
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing of 16 Sqmm 4 core Aluminium Armoured cable |
| 2 | Supply and erection of underground cable loosein existing pipe or trenches complete in all respect upto the satisfaction of engineer incharge 25 sqmm 4core cable armored of approved brand. |
| 3 | Supply of Spike Light 12w (Cat. No. VSTP SP 0312) made of pressureDie Cast Aluminium Housing with weather proof gaskit ensuring IP66protection |
| 4 | Providing and fixing of LED flood light 150 watt cat no- efe- 05150 fixture made of pressure die cast Aluminium Back Chowk Housing with front opening Toughened glass for uniform distribution of light having IP66 protection, Hight Efficiency LED, potted IP65 driver used inside with 6kva surge Protection for better performance of luminary |
| 5 | Supply and erection of 65 Amp. 3 Phase automatic/ digital time switch of Indo Asian Make HSN code 8537 along with contactor of required capacity of Indo Asian Make movement controlled by precisaty quartzoscillation operation on main supply of continue to run on built in rechargeable nickle cadium call for 150 hours in the event of power failure including cost of all petty items complete in all respect upto the entire satisfaction of Engineer in charge of work. |
| 6 | Providing and fixing of water body Fountain with Nozzles, Submersible Pumps, Filtration Lighting control Panel, Complete in all respect as entire satisfaction of engineer incharge (NS) |
| 7 | Supply ofPuPainter 4 mtr Decorative pole made out of gi Pipe with MS Base Plate Dia 325x12 min, Aluminum casting Base and Joint Without Control Box |
| 8 | Analysis RateAnalysis of Repairing of Open gym Equipment1. Welding machine with material = 100.00/- one time. (A)2. Bearing and Greasing = 367.00/-one time. (B)3. All other items i.e Seat, 200.00/- one time. (C)Front rest etcTotal A plus B plus C =667.00/- one timeNote:- including alltypes of taxes and carriage etc.It is certified that rates taken in the analysis are lowestand reasonable. |
| 9 | RATE ANALYSIS OPEN AIR GYM Double Cross walker/ Double Cross TrainerProviding and installation of outdoor gymnasium equipment as per approved design and including grouting in ground with concrete at specified location till the satisfaction of engineer in-charge.Double Cross walker/Double Cross TrainerB-class G.I. - pipe to be used of different nominal bore. Different type of Ms hushes to be used in machines and pins of material sae-8620 |
| 10 | RATE ANALYSIS OPEN AIR GYM-LEG PRESSProviding and installation of outdoor gymnasium equipment as per approved design and including grouting in ground with concrete at specified location till the satisfaction of engineer in-charge.NS Item -Leg Press: Providing designing and fixing of leg press of size 2000x550x1600 mm fabricated with main post of 114mm dia and 2.5mm thick and rest of the pipes 40mm dia and 2.5mm thick. All pipes made up of hot rolled tubula etc INCLUDING |
| 11 | RATE ANALYSIS OPEN AIR GYM - PULL CHAIRProviding and installation of outdoor gymnasium equipment as per approved design and including grouting in ground with concrete at specified location till the satisfaction of engineer in-charge.NS Item -Pull Chair and Push Chair (Two in one) 1. Dimensions (LxWxH) 1800 x 700 x 1800mm. 2. Fabricated with main post of NB 100mm (G.I) `C` Class pipe of approved make. 3. Seat main frame of NB 50 mm (G.I.) `C` Class pipe, Pipe connecting main post with handle frame of NB 65mm (G.I.) `C Class pipe. 4. Handle frame of pipe NB 32mm and NB 25mm (G.I.) `C` Class. (NB stands for nominal bore i.e. internal diameter of pipe in millimeters. 5. All pipes are powder coated with 80-120 micron thick akzo Nobel or equivalent paints. 6. All joint of pipe are robotic welded with joints scalloped as necessary and dressed |
| 12 | RATE ANALYSIS OPEN AIR GYM - TWISTERProviding and installation of outdoor gymnasium equipment as per approved design and including grouting in ground with concrete at specified location till the satisfaction of engineer in-charge.NS Item-_ Twister:- Providing, and fixing Twister of size 1700 X 1300 X 1300 mmb make of Green Gym or Equivalent fabricated with main post of 140 mm dia and 3.0 mm thick rest of the pipes are 40mm dia and 2.5 mm thick all pipes made up of hot rolled tubular steel and hot dipped galvanized, and powder coated using Akzo Nobel or equivalent of 80-120 MICRON THICK etc INCLUDING FIXING AT SITE. |
| 13 | RATE ANALYSIS OPEN AIR GYM - Rowing machineProviding and installation of outdoor gymnasium equipment as per approved design and including grouting in ground with concrete at specified location till the satisfaction of engineer in-charge.NS Item -Rowing machine: Providing designing and fixing rowing machine of size 1280x800×1150 mm fabricated with main past of 114 mm dia and 2.5mm thick and rest of the pipes 40mm dia and 2.5 mm thick. All pipes made up of hot rolled tubular steel and hot dipped galvanized and powder coated using Akzo Nobel or equivalent of 80-120 micron thick. All joints of pipe are robotic welded with joints scalloped as necessary and dressed off removing sharp edges and burrs. Zinc primer paint to be applied at all welding points prior to finishing. Handle bars are to be provided with high quality grip rubber Foothold shall be made up of nylon alloy with rounded edges to prevent any impact or injury and base cover to be made up from virgin LLDPE manufactured by rotational moulding with minimum thickness of plastic as 3mm colourful and UV resistant and environmental friendly. Bearing used shall be maintenance free duly oil sealed and self lubricated made by reputed company to be approved by Engineer in charge. Equipments to be fitted with inbuilt limiters to prevent unwanted movement. All open ends of pipe to be closed by GI/LLDPE caps for user safety. The equipment to be fixed on ground with concrete of minimum strength M-25 and J shape welded bolts and once the concrete is set, fix the equipments on to it and cover with the base plate A.I complete as per direction and approval of engineer in charge regarding material shape of equipment colour on metal seat and base pedal and fixing of equipments etc INCLUDING FIXING AT SITE. |
| 14 | Spekar 6305TD |
| 15 | Amplifier 4 set Amp |
| 16 | Wire Bundel 300 ft |
| 17 | 100 watt led light |
AI Tender Summary
Tender Timeline
Jul 28, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedAug 04, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 04, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender