}

Annual Rates Contract For Up-Keepment / Replacement Of Impaired Parts Of Lt Control Panels / Ats / Lrs And Others Allied Equipments Installed At Various Tube Wells / Pumping Stations / Dug Wells Under The Jurisdiction Of Jal Shakti (Phe) Mechanical Urban , jammu-Jammu And Kashmir

Public Health Engineering Department has published Annual Rates Contract For Up-Keepment / Replacement Of Impaired Parts Of Lt Control Panels / Ats / Lrs And Others Allied Equipments Installed At Various Tube Wells / Pumping Stations / Dug Wells Under The Jurisdiction Of Jal Shakti (Phe) Mechanical Urban . Submission Date for this Tender is 18-08-2025. Control Panel Tenders in jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

50390912
Annual Rates Contract For Up-Keepment / Replacement Of Impaired Parts Of Lt Control Panels / Ats / Lrs And Others Allied Equipments Installed At Various Tube Wells / Pumping Stations / Dug Wells Under The Jurisdiction Of Jal Shakti (Phe) Mechanical Urban
Tender
Indian
Jammu And Kashmir
Jammu
18-08-2025

Tender Documents

Tender Details

Annual Rates Contract for Up-keepment / Replacement of impaired parts of LT Control Panels / ATS / LRS and others allied equipments installed at various Tube Wells / Pumping Stations / Dug Wells under the jurisdiction of Jal Shakti (PHE) Mechanical Urban Circle, Jammu= 1 Isolating the Three Phase Starting panel panels / ATS/LRS of Motors from incoming power by way of Disconnecting of electric Power connections from damaged equipment, extracting out impaired parts and checking of fault for repairs/rectification of faults. Making of temporary arrangement for running of pumping machinery for tubewells/dug wells for interrupted running of Pumping machinery. The job includes transportation/visiting and labor charges at site. 2 Isolating the Three Phase Starting panel panels / ATS/LRS of Motors from incoming power by way of Disconnecting of electric Power connections from damaged equipment, extracting out impaired parts and checking of fault for repair/rectification of faults for interrupted running of Pumping machinery. The job includes transportation/visiting and skilled labour charges at site. 3 Providing / fitting of internal protection circuit wiring. 4 Providing / fitting of voltmeter (0-500 V) analogue. 5 Providing / fitting of voltmeter (0-500 V) digital. 6 Providing / fitting of volt selector switch. 7 Providing / fitting of ampere meter (0-63 A) analogue. 8 Providing / fitting of ampere meter (0-100 A) analogue. 9 Providing / fitting of ampere meter (0-200 A) analogue 10 Providing / fitting of ampere meter (0-500 A) analogue. 11 Providing/ fitting of ampere meter (0-1000 A) analogue. 12 Providing/ fitting of ampere meter (0-63 A) digital. 13 Providing/ fitting of ampere meter (0-100 A) digital. 14 Providing/ fitting of ampere meter (0-200 A) digital. 15 Providing/ fitting of ampere meter (0-500 A) digital. 16 Providing/ fitting of ampere meter (0-1000 A) digital. 17 Providing / fitting of ampere selector switch. 18 Providing / fitting of push button on/off. 19 Providing/ fitting of phase indicator lamps (R). 20 Providing/ fitting of phase indicator lamps (Y). 21 Providing/ fitting of phase indicator lamps (B). 22 Providing/ fitting of star delta timer. 23 Providing/ fitting of terminal/connection plate of panel Upto 100HP. 24 Providing/ fitting of terminal/connection plate of Panel Upto 101HP to 300HP 25 Providing/ fitting of terminal/connection plate of Panel Upto 301HP to 500HP 26 Providing/ fitting of terminal/connection plate of panel Upto501HP and above 27 Providing/ fitting of Electronic Motor protection relay (digital) with inbuilt protections for voltage and current related faults. 28 Providing/ fitting of Electronic Motor protection relay (digital) with guardian fault analyzer cum controller 29 Providing/ fitting of quartz timer. 30 Providing/ fitting of delay timer. 31 Providing/ fitting of power wiring of Panel Upto 100HP. 32 Providing/ fitting of power wiring of Panel Upto 101HP to 200HP. 33 Providing/ fitting of power wiring of Panel Upto 201HP to 400HP. 34 Providing/ fitting of power wiring of Panel Upto 401HP and above. 35 Providing/ fitting of thermal overload relay as per rating Upto 50 HP. 36 Providing/ fitting of thermal overload relay as per rating Upto 51 HP to 100HP. 37 Providing/ fitting of thermal overload relay as per rating Upto 101HP to 300HP. 38 Providing/ fitting of thermal overload relay as per rating Upto301HP and above. 39 Providing and Fitting of CT as per rating below Upto 63Amp. 40 Providing and Fitting of CT as per rating below Upto 100Amp. 41 Providing and Fitting of CT as per rating below Upto 200Amp. 42 Providing and Fitting of CT as per rating below Upto 300Amp. 43 Providing and Fitting of CT as per rating below Upto 400Amp and above. 44 Providing / fitting of under voltage relay. 45 Providing / fitting of over voltage relay. 46 Providing / fitting of over current relay. 47 Providing / fitting of under current relay. 48 Providing / fitting of single phase preventer. 49 Providing / fitting of delay timer. 50 Providing / fitting of Switch Disconnector Fuse unit suitable for HRC fuse link in SS Enclosure of rating 63 Amp. 51 Providing / fitting of Switch Disconnector Fuse unit suitable for HRC fuse link in SS Enclosure of rating 100 Amp. 52 Providing / fitting of Switch Disconnector Fuse unit suitable for HRC fuse link in SS Enclosure of rating 125 Amp. 53 Providing / fitting of Switch Disconnector Fuse unit suitable for HRC fuse link in SS Enclosure of rating 160 Amp. 54 Providing / fitting of Switch Disconnector Fuse unit suitable for HRC fuse link in SS Enclosure of rating 200 Amp. 55 Providing / fitting of Switch Disconnector Fuse unit suitable for HRC fuse link in SS Enclosure of rating 250 Amp. 56 Providing / fitting of Switch Disconnector Fuse unit suitable for HRC fuse link in SS Enclosure of rating 400 Amp. 57 Providing / fitting of Switch Disconnector Fuse unit suitable for HRC fuse link in SS Enclosure of rating 630 Amp. 58 Providing/fitting of HRC fuse set of rating 63 Amp. 59 Providing/fitting of HRC fuse set of rating 100 Amp. 60 Providing/fitting of HRC fuse set of rating 125 Amp. 61 Providing/fitting of HRC fuse set of rating 200 Amp. 62 Providing/fitting of HRC fuse set of rating 250 Amp. 63 Providing/fitting of HRC fuse set of rating 400 Amp. 64 Providing/fitting of HRC fuse set of rating 630 Amp. 65 Providing/fitting of kit kat fuse links of ratings 100 Amp. 66 Providing/fitting of kit kat fuse links of ratings 200 Amp. 67 Providing/fitting of kit kat fuse links of ratings 250 Amp. 68 Providing/fitting of kit kat fuse links of ratings 400 Amp. 69 Providing/fitting of kit kat fuse links of ratings 630 Amp. 70 Providing / fitting of under voltage release (UVR) relay of ACB. 71 Providing / fitting of Shunt release (SR) relay of ACB. 72 Providing / fitting of Thermal Magnetic release of ACB. 73 Providing / fitting of Lockable Trip push button of ACB. 74 Calibration/Reconditioning/Servicingof operational ACB 75 Providing / fitting of transformer coils (03 Nos.) to Auto Transformer Starter (ATS) including cost of power wiring, taping for insulation for Auto Transformer Starter (ATS) of ratings Up to 200HP. 76 Providing / fitting of transformer coils (03 Nos.)to Auto Transformer Starter (ATS) including cost of power wiring, taping for insulation for Auto Transformer Starter (ATS) of ratings Up to 201HP to 300HP. 77 Providing / fitting of transformer coils (03 Nos.) to Auto Transformer Starter (ATS) including cost of power wiring, taping for insulation for Auto Transformer Starter (ATS) of ratings Up to 301HP to 500HP. 78 Providing / fitting of transformer coils (03 Nos.) to Auto Transformer Starter (ATS) including cost of power wiring, taping for insulation for Auto Transformer Starter (ATS) of ratings Up to 500HP and above. 79 Providing / filling/topping of transformer oil to ATS (per liter). 80 Providing / fitting of copper contact set of LRS (one set) 81 Providing / filling of electrolyte to LRS (per liter). 82 Repair to the rotating mechanism of the LRS. 83 Providing / fitting of link / DO set to electric substation. 84 Providing / fitting of lightening arrestor to electric substation. 85 Providing / fitting of fuse set to electric substation. 86 Providing/fitting of MCB-2 Amp. 87 Providing/fitting of MCB-6 Amp. 88 Providing/fitting of 3 pole MCCB-63 Amp @ 415V AC of breaking capacity 10kA. 89 Providing/fitting of 4 pole MCCB-63 Amp @ 415V AC of breaking capacity 10kA. 90 Providing/fitting of 3 pole MCCB-100 Amp @ 415V AC of breaking capacity 18kA. 91 Providing/fitting of 4 pole MCCB-100 Amp @ 415V AC of breaking capacity 18kA. 92 Providing/fitting of 3 pole MCCB-100 Amp @ 415V AC of breaking capacity 30kA. 93 Providing/fitting of 4 pole MCCB-100 Amp @ 415V AC of breaking capacity 30kA. 94 Providing/fitting of 3 pole MCCB-125 Amp@ 415V AC of breaking capacity 18kA. 95 Providing/fitting of 4 pole MCCB-125 Amp@ 415V AC of breaking capacity 18kA. 96 Providing/fitting of 3 pole MCCB-125 Amp@ 415V AC of breaking capacity 30kA. 97 Providing/fitting of 4 pole MCCB-125 Amp@ 415V AC of breaking capacity 30kA. 98 Providing/fitting of 3 pole MCCB-160 Amp@ 415V AC of breaking capacity 36kA. 99 Providing/fitting of 4 pole MCCB-160 Amp@ 415V AC of breaking capacity 36kA. 100 Providing/fitting of 3 pole MCCB-160 Amp@ 415V AC of breaking capacity 50kA. 101 Providing/fitting of 4 pole MCCB-160 Amp@ 415V AC of breaking capacity 50kA. 102 Providing/fitting of 3 pole MCCB-250 Amp of rating@ 415V AC of required breaking capacity 25kA. 103 Providing/fitting of 4 pole MCCB-250 Amp of rating@ 415V AC of required breaking capacity 25kA. 104 Providing/fitting of 3 pole MCCB-250 Amp of rating@ 415V AC of required breaking capacity 36kA. 105 Providing/fitting of 4 pole MCCB-250 Amp of rating@ 415V AC of required breaking capacity 36kA. 106 Providing/fitting of 3 pole MCCB-400 Amp@ 415V AC of required breaking capacity 36kA. 107 Providing/fitting of 4 pole MCCB-400 Amp@ 415V AC of required breaking capacity 36kA. 108 Providing/fitting of 3 pole MCCB-400 Amp@ 415V AC of required breaking capacity 50kA. 109 Providing/fitting of 4 pole MCCB-400 Amp@ 415V AC of required breaking capacity 50kA. 110 Providing/fitting of 3 pole MCCB-400 Amp@ 415V AC of required breaking capacity 70kA. 111 Providing/fitting of 4 pole MCCB-400 Amp@ 415V AC of required breaking capacity 70kA. 112 Providing/fitting of 3 pole MCCB-630 Amp@ 415V AC of required breaking capacity 36kA. 113 Providing/fitting of 4 pole MCCB-630 Amp@ 415V AC of required breaking capacity 36kA. 114 Providing/fitting of 3 pole MCCB-630 Amp@ 415V AC of required breaking capacity 50kA. 115 Providing/fitting of 4 pole MCCB-630 Amp@ 415V AC of required breaking capacity 50kA. 116 Providing/fitting of 3 pole MCCB-630 Amp@ 415V AC of required breaking capacity 70kA. 117 Providing/fitting of 4 pole MCCB-630 Amp@ 415V AC of required breaking capacity 70kA. 118 Providing/fitting of 3 pole power contactor of 25 Amp. 119 Providing/fitting of 3 pole power contactor of 32 Amp. 120 Providing/fitting of 3 pole power contactor of 40 Amp. 121 Providing/fitting of 3 pole power contactor of 50 Amp. 122 Providing/fitting of 3 pole power contactor of 70 Amp. 123 Providing/fitting of 3 pole power contactor of 80 Amp. 124 Providing/fitting of 3 pole power contactor of 95 Amp. 125 Providing/fitting of 3 pole power contactor of 110 Amp. 126 Providing/fitting of 3 pole power contactor of 140 Amp. 127 Providing/fitting of 3 pole power contactor of 185 Amp. 128 Providing/fitting of 3 pole power contactor of 225 Amp. 129 Providing/fitting of 3 pole power contactor of 250 Amp. 130 Providing/fitting of 3 pole power contactor of 300 Amp. 131 Providing/fitting of 3 pole power contactor of 400 Amp. 132 Providing/fitting of 3 pole power contactor of 550 Amp. 133 Providing/fitting of 3 pole power contactor of 650 Amp. 134 Providing/fitting of 3 pole power contactor of 1250 Amp. 135 Providing/fitting of spare contactor kit of 3 pole power contactor of 25 Amp. 136 Providing/fitting of spare contactor kit of 3 pole power contactor of 40 Amp. 137 Providing/fitting of spare contactor kit of 3 pole power contactor of 50 Amp. 138 Providing/fitting of spare contactor kit of 3 pole power contactor of 70 Amp. 139 Providing/fitting of spare contactor kit of 3 pole power contactor of 80 Amp. 140 Providing/fitting of spare contactor kit of 3 pole power contactor of 95 Amp. 141 Providing/fitting of spare contactor kit of 3 pole power contactor of 110 Amp. 142 Providing/fitting of spare contactor kit of 3 pole power contactor of 140 Amp. 143 Providing/fitting of spare contactor kit of 3 pole power contactor of 185 Amp. 144 Providing/fitting of spare contactor kit of 3 pole power contactor of 225 Amp. 145 Providing/fitting of spare contactor kit of 3 pole power contactor of 250 Amp. 146 Providing/fitting of spare contactor kit of 3 pole power contactor of 300 Amp. 147 Providing/fitting of spare contactor kit of 3 pole power contactor of 400 Amp. 148 Providing/fitting of spare contactor kit of 3 pole power contactor of 550 Amp. 149 Providing/fitting of spare contactor kit of 3 pole power contactor of 650 Amp. 150 Providing/fitting of spare contactor kit of 3 pole power contactor of 1250 Amp. 151 Providing/fitting of Front Mounting add on auxiliary contact block of 3 pole power contactor 152 Providing/fitting of Side Mounting add on auxiliary contact block of 3 pole power contactor 153 Providing/fitting of operating /Spare coil of 3 pole power contactor of 25A to 40A 154 Providing/fitting of operating /Spare coil of 3 pole power contactor of 50A to 80A 155 Providing/fitting of operating /Spare coil of 3 pole power contactor of 95A to 140A 156 Providing/fitting of operating /Spare coil of 3 pole power contactor of 185A to 250A. 157 Providing/fitting of operating /Spare coil of 3 pole power contactor of 300 A to 400A 158 Providing/fitting of operating /Spare coil of 3 pole power contactor of 550 A to 650A 159 Providing/fitting of operating /Spare coil of 3 pole power contactor of 1000A to 1250A 160 Providing/fitting of change Over Switch Disconnectors (Manual Open execution) 63 Amp. 161 Providing/fitting of change Over Switch Disconnectors (Manual in SS Enclosure) 63 Amp. 162 Providing/fitting of change Over Switch Disconnectors (Manual Open execution) 100 Amp. 163 Providing/fitting of change Over Switch Disconnectors (Manual in SS Enclosure) 100Amp. 164 Providing/fitting of change Over Switch Disconnectors (Manual Open execution) 200 Amp. 165 Providing/fitting of change Over Switch Disconnectors (Manual in SS Enclosure) 200Amp. 166 Providing/fitting of change Over Switch Disconnectors (Manual Open execution) 250 Amp. 167 Providing/fitting of change Over Switch Disconnectors (Manual in SS Enclosure) 250Amp. 168 Providing/fitting of change Over Switch Disconnectors (Manual Open execution) 400 Amp. 169 Providing/fitting of change Over Switch Disconnectors (Manual in SS Enclosure) 400Amp. 170 Providing/fitting of change Over Switch Disconnectors (Manual Open execution) 630 Amp. 171 Providing/fitting of change Over Switch Disconnectors (Manual in SS Enclosure) 630Amp. 172 Providing /fitting of bus bars of rating Up to 100Amp. 173 Providing /fitting of bus bars of rating Up to 200Amp to 400Amp. 174 Providing /fitting of bus bars of rating Up to 401Amp and above. 175 Providing and fitting of copper thimble of capacity 16 sq. mm 176 Providing and fitting of copper thimble of capacity 25 sq. mm 177 Providing and fitting of copper thimble of capacity 35 sq. mm 178 Providing and fitting of copper thimble of capacity 50 sq. mm 179 Providing and fitting of copper thimble of capacity 80 sq. mm 180 Providing and fitting of copper thimble of capacity 95 sq. mm 181 Providing and fitting of copper thimble of capacity 100 sq. mm 182 Providing and fitting of copper thimble of capacity 120 sq. mm 183 Providing and fitting of copper thimble of capacity 150 sq. mm 184 Providing and fitting of copper thimble of capacity 185 sq. mm 185 Providing and fitting of copper thimble of capacity 200 sq. mm 186 Providing and fitting of copper thimble of capacity 300 sq. mm 187 Providing and fitting of Aluminum thimble of capacity 25 sq. mm 188 Providing and fitting of Aluminum thimble of capacity 35 sq. mm 189 Providing and fitting of Aluminum thimble of capacity 50 sq. mm 190 Providing and fitting of Aluminum thimble of capacity 80 sq. mm 191 Providing and fitting of Aluminum thimble of capacity 95 sq. mm 192 Providing and fitting of Aluminum thimble of capacity 120 sq. mm 193 Providing and fitting of Aluminum thimble of capacity 150 sq. mm 194 Providing and fitting of Aluminum thimble of capacity 185 sq. mm 195 Providing and fitting of Aluminum thimble of capacity 200 sq. mm 196 Providing and fitting of Aluminum thimble of capacity 240 sq. mm 197 Providing and fitting of Aluminum thimble of capacity 300 sq. mm 198 Providing and fitting of Aluminum thimble of capacity 385 sq. mm 199 Providing and fitting of Aluminum thimble of capacity 400 sq. mm 200 Providing and fitting of Aluminum thimble of capacity 500 sq. mm 201 Providing and fitting of Aluminum thimble of capacity 630 sq. mm 202 Making of 3 phase Power connection to repaired electric equipment including checking all the incoming and outgoing three phase electric power cable connections from electric transformer to panels connections. Testing on no load, and then full load at site. Complete job includes labor charges.

Key Value

Document Fees
INR 1000 /-
EMD
INR 100000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail