Tender For Integrated Conservation Landscaping And Adaptive Upgradation Of Raja Bharmal Ki Chattariyan Royal Cenotaph Of Amber.-- 1 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge 3 1: 4: 8 or leaner mix.(B-14/14.2.2) 4 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-incharge.In cement mortar.(B-14/14.3) 5 Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:For thickness of tiles 25mm to 40mm. 14.23.1 6 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:PWD. Item no. 9.2 7 Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar.(B-14/14.9.2) 8 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. 9 CARRIAGE OF MATERIALS Building Rubbish Stone metal (Grit and ballast etc.) For 10 Km.For Depth upto 1.50 m G-4.1 10 Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed: Ordinary rock (B-1/1.7) 11 Earth work in excavation by mechanical means (Hydraulicexcavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed : All kinds of soil(B-1/1.6) 12 Filling available excavated earth (excluding rock) in trenches,plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.(B-1/1.25) 13 add extra carriage of sand up to 10 km lead 14 Providing and laying inposition cement concrete including curing, compactionetc.completein specified grade excluding the cost of centering and shuttering All work upto plinth level. 15 M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size)..(B-3/3.1.2) 16 M10 grade Nominal Mix1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 17 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.M20 grade Nominal Mix / Design Mix (B-4/4.1) 18 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix(B-4/4.2) 19 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix (B-4/4.3) 20 Providing M-25 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix.(B-4/4.6.1) 21 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Thermo-Mechanically Treated bars.(for all concrete works)Reinforcement for above @ 1.1 % or 120 kg / cum (B-4/4.13.3) 22 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.(B-4/4.9) 23 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for (B-4/4.10) 24 Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc.(B-4/4.10.2) 25 Columns, Pillars, Piers, Abutments, Posts and Struts. (B-4/4.10.3) 26 Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks(B-5/5.1) 27 Cement mortar 1 : 6 (1 cement : 6 coarse sand)(B-5/5.1.2) 28 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :(B-5/5.2) 29 Cement mortar 1 : 6 (1 cement : 6 coarse sand) (B-5/5.2.2) 30 Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand)5.8.2 31 Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry . 32 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). (B-6/6.1.6) 33 Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in :Cement Mortar 1:6( 1-Cement : 6-Sand). (B-6/6.2.6) 34 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : (B-12/12.2) 35 20mm thick .(B-12/12.2.2) 36 12mm thick ..(B-12/12.2.3) 37 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand)(B-12/12.5) 38 Rough Chisel dressed Sand stone 35 mm thick flooring of approved shade set over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointing with cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects :Red sand stone (Karauli stone) 11.21.1 39 Stone work (machine cut edges) for Wall cladding/ Veneering work up to 10m height with 20 to 30 mm thick Red Sand Stone (Karauli ) and backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade To be secured to the backing by means of cramps which shall be paid separately) Exposed face machine cut 40 Stone work (machine cut edges) for Wall cladding/ Veneering work up to 10 m height with 20 to 30 mm thick Pink Sand stone (Bansi Paharpur) and backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid separately) 41 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases in stone and holes in walls wherever required. (B-6/6.11) 42 Providing and fixing stone dowels 10x5x2.50 cm cut to double wedge shape as per design in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases.(B-6/6.12) 43 Supplying and fixing machine cut fine dressed Red/Pink sand stone dasa or coping, with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade.25 mm thick(B-6/6.19.1) 44 Supplying and fixing machine cut fine dressed Red/Pink sand stone dasa or coping, with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade.50mm thick 45 Fine grinded Gangsaw cut 30-35 mm thick stone flooring over 20 mm (average) thick base of cement mortar 1:4 (1 cement :4 coarse sand) jointed grey cement slurry mixed with pigment to match the shade of stone complete as per design drawing and instruction of EI. 46 Supply& fixing of M-20grade precast cement concrete Kerb or Dand upto 60cm length over 20mm thick base of cementmortar1:6 including jointing earthwork,pointing& jointing with cement mortar 1:4 of size20 x 25 cm PWD.CH. No.5.8.1 47 Fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:4 ( 1cement : 4 coarse sand) with joints finished flush. Red Sand stone size not less than 1350 Cm2, 40 mm - thk stone to be match with existing flooring 48 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).)For fixed portionPowder coating aluminum ( minimum thickness of powder coating 50 micron)(B-16/16.1.1.2) 49 For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Powder coating aluminum ( minimum thickness of powdercoating 50 micron) (B-16/16.1.2.2) 50 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in chargePrelaminated particle board with decorative lamination on both sides.(B-16/16.4.2 ) 51 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness (B-16/16.5.3) 52 Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 fine sand): Flush/ Ruled pointing.(B-12/12.37 ) 53 Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.(B-16/16.8 ) 54 Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-chargePolyester powder coated minimum thickness 50 micron aluminium . (B-16/16.9.3 ) 55 Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-charge Powder coated minimum thickness 50 micron aluminium 8.26 56 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent with pair of CP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge.8.31 57 Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.Powder coating aluminum ( minimum thickness of powder coating 50 micron) (B-16/ 16.10.2) 58 S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding.(B-16/16.11) 59 Providing & fixing door, window, chowkhats and otherframes, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade :Ivory coast wood Grade I 8.1.6 60 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete20 mm 8.25.2 61 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) (B-12/12.22.1) 62 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect (B-12/12.40.2) 63 Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provisionNew Work (B-12/12.43.1) 64 Providing and applying plaster of paris putty of 2 mmthickness over plastered surface to prepare the surface even and smooth complete PWD. CH. No.12.23 65 Steel work in built up tubular trusses including cutting,hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished seamless type tubes.9.3.2 66 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide (B-9/9.8 ) 67 Extra if square,rectangular hollow tubelar sections are used or grill made by flats only 9.8.1 68 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work(B-12/12.46.1) 69 Providing and fixing Stone jali 50mm thick Red/Pink sand stone as per ornamental design to fixed with white cement/epoxy mortar including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade.6.22 70 Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, nickel plate MS 20 mm dia curtain rod with nickel plated bracket including fixing with 25x3 mm MS flat 10 cm long all bcomplete 8.24 71 Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, nickel plate MS 20 mm dia curtain rod with nickel plated bracket including fixing with 25x3 mm MS flat 10 cm long all complete 16.58 72 Providing and fixing Red/Pink sand stone post (Mataga)having size 100x100mm heights 600 to 750 mm as perornamental design such as like flower octonogal head border etc. to fixed with white cement/epoxy mortar including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade.6.23 73 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 74 Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification: Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by usingabove formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work. 75 White washing with lime to give an even shade including all scaffolding:New work (three or more coats).12.34.1 76 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 77 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cementmortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. 78 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.7.6.1 i 79 Granite/Kota Stone Work Full Edge moulding 7.6.1 i 80 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work includingnecessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 7.8 81 Extra for Mirror polishing on marble work where ever required to give high gloss finish complete PWD. CH. No.7.9 82 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades ceramic glazed vitrified tiles with water absortion less than or equal to 0.08% confirming to IS:13753 & IS : 15622 on walls, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).7.20.1 83 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades ceramic glazed vitrified tiles with water absortion less than or equal to 0.08% confirming to IS:13753 & IS : 15622 on walls, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).Size 196mm x 1215mm 7.20.3 84 P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size 600 mm X 1200 mm 7.24.1 85 P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size 600 mm X 600 mm 7.24.1 86 Providing and fixing horizontal chajja of Red/ White sand stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade 87 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure A35 mm thick Decorative teak veneer both side 8.13.3.3 88 Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item 8.14 89 Extra for providing vision panel not exceeding 0.1 Sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) :8.15 90 Providing and applying Melamine polish on teak wood work of approved brand and manufacture to give an even shade with two or more coats by compressor including sand papering, wood filler coat etc complete in all respect New Surface 12.50.1 91 Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification.50mm thick.3.7.1 92 Supplying and Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand 93 Anti termite treatment of floor using Imidacloprid 30.5% EC non repellent, odorless, low dose, environmentally safe terniticide with rapid action non corrosive stain free, by drilling 12mm diameter holes 300mm apart injecting the emulsion as per specification and plugging with cement mortar1:2 ( 1 cement : 2 coarse sand) in the whole floor area DPE 12mm dia termitube system with required number of junction boxes are to be installed. The termitube will run all along the perimeter wall both inside and outside. In the middle area thetermitube to be installed at an interval of 1.00 Mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. After successful testing of termitube, pesticide emulsion of imidacloprid 30.5% EC mixed withwater in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. The plinth area of the area treated will be measured for payment 1.39 94 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in allcolour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment size 1000 mm X 1000mm 7.25.3 95 Extra for pre finished nosing in treads of steps of Kota stone/sand stone slab. 11.24 96 Filling the gap upto 5 mm depth and 5 mm width in betweenaluminium frame & adjacent RCC/ Brick/ Stone work byproviding weather silicon sealant over backer rod of approvedquality as per architectural drawings and direction of Engineerin-charge complete.16.7 97 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane.15.11 98 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting offollowing operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound conforming to IS. 2645 over the RCC slab including cleaning the surface before treatment.(b) Laying cement concrete using broken bricks/brick bats 25 mm to 100mm size with 50% of cement mortar 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:4 (1 cement :4 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300x300xmm square (e) The whole terrace so finished shall be flooded with 10.21 water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm. 99 Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shadeand colour completeincluding all scaffolding as permanufacturers specification. Two or more coats on new work including prepartion of basewith primer, putty, lippy etc complete in all respect. New work (two or more coats) over and including priming coat with cement primer. 32.30.1 100 Landscaping and beautification 101 Laying of lawns including ploughing levelingbreaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost : in rows 15 cm apart in either direction 3.1.1 102 Laying of Selection No.1 grass tiles (2‟X2‟ size) for development of garden, including levelling of soil and spreading of manure PWD. Item no 3.1.4 103 Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc.good soil of earth PWD. Item no. 1.3.1 104 Supply of dry manure including loading unloading,transportation & stacking at site. Farm yard manure ( organic )PWD. Item no. 1.1.1 105 Hedges of various varietiesEnarmi in P.B(5”X5”) - 1‟1.22.3 106 Planting of trees /shrubs/ hedge and climbers plants at desired distance in row and watering 107 SANITARY WORKS 108 P. & F Squatting Pan (Indian type) white glazed vitreous china 1st quality W.C. Pan (IS : 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor (excluding the pair of foot rest.) Size 510 mm 1.1.2 109 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall:WVC with C.P. brass bend.1.20.1 110 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor.1.13.1 111 P & F Jet spray for water closet with C.P. Copper Tube flange1.59 112 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (large) or half stall size 610x400x80mm1.14.2 113 P & F W.V.C. Urinal Partition Plate of approved standard make of size 630x315mm including making good the wall. 114 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 610 mm x 510 mm 115 Providing & Fixing Premium quality Bottle trap internal portion 32mm, size 250mm long wall connection pipe & wall flange as per approved by Engineer in Charge 116 Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge 117 Soap dish 118 Paper Holder 119 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers-Size 600 x 450mm x 4 mm thick 120 Providing & fixing C.P.flange for 15mm dia taps 121 P & F Extension Pipe for bib cocks of approved quality/make.C.P. brass of Heavy & Superior quality 50x15mm 122 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:C.P. Brass bib cock,15mm nominal bore. 123 P & F Inlet Connection (Angle Valves) Superior quality, ofapproved make, for Wash basin, Gyser etc C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 124 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 3.45.2 125 75 mm dia 126 110 mm dia 127 Providing and Fixing Unplasticized Poly Vinyl Chloride(UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Coupler 110 mm diaBend 87.5 Dg. 110mm dia (ii) 3.45.4 128 Providing and fixing on wall face Unplasticised Rigid PVC Single socketed pipes rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 110 mm dia 129 Pipe Clip. 110mm dia (ii) 3.45.4 130 Nahni Trap with Jali 4 110mm dia (ii) 3.45.25 131 1.0 mm thick stainless steel AISI -304 & IS 13983-1994 kitchen sink of approved make as per Engineer-in-charge with large waste coupling.1.38.9 132 37 x 18 x 7 17x15x7 (with drain board) 1.38.9.4 133 P& F waste Pipe with all fitting P.V.C. with C.P. nut 40 mm dia 1.43.3 134 P & F Inlet Connection (Angle Valves) Superior quality, ofapproved make, for Wash basin, Gyser etc C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 135 P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm. 3.5.1 136 Supplying and fixing C.I. Cover with frame, C.I. gratings for chambers & man holes. 3.31 137 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 50 mm nominal size 2.37.4 138 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 2.38 139 15 mm nominal size 2.38.1 140 20 mm nominal size 2.38.2 141 25 mm nominal size 2.38.3 142 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).(S-2/2.39) 143 32mm nominal size (S-2/2.39.4) 144 50 mm nominal size (S-2/2.39.5) 145 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 ltr. Capacity(2.26.5) 146 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make (-do-) 32mm nominal bore.2.15.4 147 (-do-) 50mm nominal bore 2.15.6 148 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 .) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.160 mm dia.3.16.4 149 Providing & Laying C.C. 1:3:6 (Stone Agreegate 20mm nominal size) all around PVC Pipe including 7.5 cm thick bed concerte [Width & Height = Dia of Pipe in CM+15 CM] excluding cost of Pipe & Excavation of trenches etc.PVC pipe 160 mm dia 3.16.5.2 150 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C. flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design Depth up to 1.5 M 3.20.1 151 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M- 15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- 3.27 152 Size 400 x140x150 cm.(for 50 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect. 3.27.3