| 1 | Dismantling of stone slabs & tiles of anythickness & in any position laid, bedded and pointed in any mortar otherwise complete all as specified and directed. |
| 2 | Demolition cement concrete of any description and any position not otherwise specifically provided for complete all as specified and directed. |
| 3 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 4 | Dismantling floor, hearth or wall tiling etc including cement mortar bedding etc (but not backing)and removing rubbish off the premises complete all as specified and directed. |
| 5 | Demolition of cement concrete unreinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 6 | Dismantlling of Plain or corrugated steel sheeting, asbestos cement sheet, fibre glass reinforced translucent any gauge, thickness, including Nainital orsimilarpattern roof covering complete all as specified. |
| 7 | Dismantling and refixing of existing chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wirecomplete all as specified and directed. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 9 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removal of rubbish from site complete all as specified and directed. |
| 10 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 11 | M&L for PCC 1:2:4 type B1using 20mm graded aggregateas in surface channels and drains complete all as specified and directed. |
| 12 | M&L for providing precast cement concrete louvres and jallies 35 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4including taking down old louvers/jallies of any description, complete all as specified and directed. |
| 13 | M&L for precast cement concrete type B1(1:2:4) (20mm graded aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 including necessary formwork required complete all as specified and directed. |
| 14 | M&L for reinforced cement concrete (Nominal Mix) Type B1 1:2:4 using 20mm graded stone aggregate as in rafts, footings, foundation, beams; plinth beams; bases for columns and mass concrete, etc complete all as specified and directed. |
| 15 | M&L fly ash bricks old size straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 16 | Refixing of demolised old Brick work using fly ash bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 17 | M&L for providingcement concrete 1:3:6, type C2 (40mm graded aggregate] in post, foundations, filling and mass concrete complete all as specified and directed. |
| 18 | M&L for Granite 18 to 20 mm thick (of any type) work (table rubbed and polished) for wall lining(veenering to wall ) 10 mm thick in cement mortar (1:3 )and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 19 | M&L 18-20mm thick Lakha red granite work (table rubbed and polished including moulding, polishing) as in floor etc in any position including 15mm thick screed bed in cement mortar (1:4) and pointing with white or coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite of existing floors complete all as specified and directed. |
| 20 | S&F for Dholpur stone 16 to 18mm thick ,cladding gang saw cut with machine cut edges, uniform colour of each stone size notexceeding 0.25 sqm fixed with and including10 mm thick in cement mortar (1:3 )and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade Note :- Work to be carried out in multy storey bldgs, necessary steel scafolding shall be included in the rate complete all as specified and directed. |
| 21 | M&L for Form work to sides of concrete foundations, footings, sides and soffits of floor slab and plinth beams, columns and similar work vertical or batter rough finished surface of concrete complete all as specified & directed. |
| 22 | M& L for hand rails, half round or others stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc, wind ties for roof including securing bolts, posts and strutsbrackets etc in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for secuing wire mesh etc.) including all necessary drilling, bolting or reveting etc., and similar work confirming to FE-290 Gde E-165 complete all as specified and directed. |
| 23 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and \"scraved the other to be fitted with washers and one hexagonal or square nut n.exc 5 cm long and dia 5 to 10 mm complete all as specified and directed. |
| 24 | M & L for Steel work in tubular trusses including special shaper washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240complete all as specified and directed. |
| 25 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to FE-290 Gde E-165 complete all as specified and directed. |
| 26 | S&F MS plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachementconforming to Fe 410 W (Grade E-250 ,quality \"A\") complete all as specified and directed. |
| 27 | S&F 1.25mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified & directed. |
| 28 | M&L,MS round bars 10 mm dia and over cut to length, bent to shape reqd incl cranking bending etc and binding with MS wire (annealed) not less than 0.9 mm dia as in chain link fencing fixing complete all as specified and directed. |
| 29 | S&F for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. and similar small articles conforming to Fe 410 W (Grade E-250 ,quality \"A\" ) complete all as specified and as directed. |
| 30 | M&L for 75 mm thick Cement concrete 1:4:8type D-2using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 31 | M & L for 50 mm thick PCC 1:2:4 type B1 (20 mm graded aggregate)(using 20mm graded stone aggregates) in pavement/ hard-standing laid in alternative panels, surface finished even and smooth without using extra cement, including necessary form work, complete all as specified and directed. |
| 32 | M&L Chequered cement concrete tiles 30cm x30cmx 25mm thick with grey cement and pigment , set jointed in neat cement slurry , including 20 mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes all as specified and directed. |
| 33 | M&L outdoor parking tiles of size 400mmx400mmx10mm thick, set jointed in neat cement slurry , including 20 mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes all as specified and directed. |
| 34 | Providing and laying Machine pressed precast concrete interlocking paver block any shape and size with grey cement and no pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. |
| 35 | Providing and laying Machine pressed precast concrete interlocking paver block any shape and size with grey cement and no pigment confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and directed. |
| 36 | M & L in repairs for dismantling interlocking paver block of thickness 60mm and refixing in postion as specified after slope correction all as specified and directed. |
| 37 | M & Lin repairs for dismantling interlocking paver block of thickness 80mm and refixing in postion as specified after slope correction all as specified and directed. |
| 38 | M&L Factory made for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm),making drainage opening wherever required including dismantling of old kerb stone complete all as speecifed and directed |
| 39 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 40 | Taking down cement plaster on brick/concrete surfce includingracking out joints heaking for key scrubbing down with water etc., complete all as specified and directed. |
| 41 | M&L for prepartion of new concrete surface of any description over 10cm girth or width, not otherwise described applying two coats of synthatic enamel paint over a coat of primer completa all as specfied and directed. |
| 42 | M&L for prepartion of old kerb stone /concrete surface of any description over 10cm girth or width, not otherwise described applying one coats of synthatic enamel paintcomplete all as specfied and directed. |
| 43 | M&L for preparation of old treated surfaces of kerb stoneby complete removing of existing treatment and applying two coat ofsynthatic enamel paint complete all as specified and directed |
| 44 | M&L 15 mm thick rendering in CM 1:6 on other than fair faces of brick work & finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 45 | M&L Preparing of newly plastered surfaces and applying two coats of cement based paint (of approved tint) over a coat of primer complete all as specified and directed. |
| 46 | M&L Preparing of old plastered surfaces and applying one coats of cement base paint (of approved tint) complete all as specified and directed |
| 47 | M&L Preparing of old plastered surfaces and applying two coats of cement base paint (of approved tint) complete all as specified and directed. |
| 48 | Material & Labour for applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over wall surfaces complete all as specified and directed. |
| 49 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 50 | S & F in Fibre glass reinforced translucent corrugated sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed. |
| 51 | S & F pre painted galvalume aluminum Zinc coating GI based plain steel sheeting 0.5mm thick of any colour having tensile strength of 550 MPA as in ridge ,gutters etc fixed with self tapping screws complete all as specified and directed. |
| 52 | M&L for 6 mm thick asbestos cement, corrugated or semi corrugated sheets in roofs fixed with \"L\" hooks or \"J\" bolts complete all as specified and directed. |
| 53 | S & F in Fibre glass reinforced translucent plain sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc as specified and directed. |
| 54 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framedguard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 55 | Dismantling of GI barbed wire fencings fixed in RCC/Steel fencing posts complete all as specified and directed. |
| 56 | S&F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any tpe of standard rails straining bolts, incl securing or tying at crossings and provn of galvanised mild steel wire stappled or steel pins, etc complete all as specified and as directed.Note: Each line wire to be measured |
| 57 | M&L forRestraining, resecuring for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any tpe of standard rails straining bolts, including making good staples etcincl securing or tying at crossings and provn of galvanised mild steel wire stappled or steel pins, etc complete all as specified and as directed.Note: Each line wire to be measured complete all as specified and directed. |
| 58 | M & L for welding in repairs to structural steel / grill / guard bars exc 2.5 cm but not exc 5.00 cm in length and thickness of metal to be welded n. exc 6 mm complete all as specified & directed. |
| 59 | S&F Welded steel wire fabric (N exc 4.0 kg/Sqm) fixed complete to wood or steel frame work complete all as specified and directed. |
| 60 | S&F in repair galvanised punched typeConcertina coils of 1050 mm dia whenstretched to 8 mtr length and fixed on angle iron post/ struts with 3.15 mm dia GI wire etc complete all as specified and directed.Note:- Stretched length of concertina coil shall be measured & paid for. |
| 61 | M&L for Glass dividing strip 3mm thick and 38 mm wide inserted in position, conform to design complete all as specified and directed. |
| 62 | M&L for preparation of new steel surfaces of any description, not otherwise described not exc 10cm width or girth and applying 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 63 | M&L for earthwork filling with combination of mixture of sand (80%) andsaw dust (20%) in proportion to be delivered at site under own arrangement complete all as specified and directed by Engr in Charge. (01 Load = 8 Cum)Note : Rate quoted shall deemincluded for loading & unloading and stacking at the destination complete. |
| 64 | M&L for cutting of existing compacted earthwork (any type) filling and screening for separation of small metals from sand and removed away from site outside the defence land under own arrangements complete all as specified and directed by Engr in Charge. Note : Rate quoted shall deemincluded for loading & unloadingcomplete. |
| 65 | M&L for preparation of old steel surfaces of any description, not otherwise described not exc 10cm width or grith and applying 1 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 66 | M&L for providing cement concrete 1:2:4 type B-1using 12.5 mm graded aggregate as in coping incl weathering, slightly rounded or chamfered angle and throating complete all as specified and directed. |
| 67 | S&F Steel rolling shutters, thickness of laths 1.25mm, withoutball bearing including top cover, anchoring rod, hasp and staple, safety lever locks mild steel with 4 leversone shop coat of primer; erected in position as indicated, push pull or manual type erected in position as indicated, fixed in repairs, complete all as specified & directed. |
| 68 | M&L for preparation of floor/paver/path/chequered tile surfaces and applying a coat of glossy finish exterior emulsion paint with existing colour or any other selected colour by using hand roller etc complete all as specified and as directed by Engr-in-Charge. |
| 69 | M&L for cleaning of existing joints and Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound,Grade ‘A’ complete all as specified and directed. |
| 70 | Taking down and refixing of Steel rolling shutters, thickness of laths 1.25mmincluding top cover, anchoring rod, hasp and staple, safety lever locks mild steel with 4 levers after servicing, greasing and replacement of any parts for functioning of rolling shutter complete all as specified & directed. Note : No extra payment should be paid to contractor for fixing any new item for smooth functioning of rolling shutters at site complete all as specified and directed. |