| 1 | Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 meter in depth for laying/ taking out of pipe in soft/loose soil, complete all asdirected. |
| 2 | Returning/ refilling in trenches including spreading levelling, watering and well ramming in layer not exceeding 25 cm thick, complete all asdirected. |
| 3 | Removal of excavated surplus soilnot exceeding 50 meter and depositing where directed at level not exceeding 1.5 metre above the starting point, complete all asdirected. |
| 4 | Supply and laying pipe ERW steel including specials and welding work as per site requirement of size 250 mm diaas per IS 3589(1981) thickness 6 mmcomplete all as specified anddirected |
| 5 | All as per item No 4 here-in-before but of size 200 mm dia. |
| 6 | All as per item No 4 here-in-before but of size 150 mm dia. |
| 7 | Material and labour for desilting, scraping, cleaning thoroughly RCC under ground sump 5 lakh gallons capacity (in two compartments), scrapping all dirt, dust andrust from wall, roofs, side, bottom, inlet and outlet pipes by clean water mixed with high dose chemical flushing and bleaching powder solution @ 0.5 kg per square metre, draining out the muddy water through wash-out pipe, two coat of white wash including necessary arrangements for breathing for human being on job, safety belts, helmets, use and waste shuttering, motor pumps as required to drain out the reservoirs, arrangements for climbing up/down to water reservoirs,writing the date of cleaning with black and white colour paint complete all as specified and directed.NOTE:- The job includes arrangement of any other plant as required like motor pump and DG set to drain out the reservoirs and resetting of existing arrangements of all equipments of reservoirs like floats, water level indiacators, pipeline and sluice valves directlty connected with reservoirs for smooth functioning complete . |
| 8 | All as per item No 7 here-in-before but RCC UG Sump 3 lakh gallons capacity (in two compartments), complete. |
| 9 | All as per item No 7 here-in-before but RCC UG Sump 1.57 lakh gallons capacity (in one/two compartments), complete . |
| 10 | All as per item No 7 here-in-before but for RCC over head water tanks at 50 feet staging 3 lakh gallons capacity (in two compartments), complete |
| 11 | All as per item No 7 here-in-before, but for RCC over head water tanks at 50 feet staging 2 lakh gallons capacity (in one/two compartments), complete . |
| 12 | All as per item No 7 here-in-before, but for RCC over head water tanks at 50 feet staging 1.5 lakh gallons capacity (in one/two compartments), complete . |
| 13 | All as per item No 7 here-in-before, but for RCC over head water tanks at 50 feet staging 1 lakh gallons capacity (in one/two compartments), complete . |
| 14 | All as per item No 7 here-in-before, but for RCC over head water tanks at 50 feet staging .6 lakh gallons capacity (in one/two compartments), complete. |
| 15 | All as per item No 7 here-in-before, but for RCC over head water tanks at 50 feet staging .5 lakh gallons capacity (in one/ two compartments), complete . |
| 16 | Material and labour for opening and proper closing the existing filtration tankof swimming pool of 8000 gallons per hour capacity for repair/ servicing and cleaning by taking out filter media sand/aggregate/carbon filter media etc and refilling of the same .The job includes for resetting the filtration plant in functional condition as before complete all as specified and directed. |
| 17 | Material and labour for repair/servicing to 40 HD high pressure single head adjustable gear motor dosing pump of 40 HD capacity by repair/servicing of spare parts like pump tube, suction/discharge tubing, inject check valve, foot ball, adaptor with connecting nut, duck bill, connecting nut, valve o ring, rotor assembly, coil, roller assembly and terminal lugs, nut, bolts, cleaning/repairing of settling tank as required at site including testing of dosing pump sets to check the smooth functioning complete all as specified directed. (Note:- spares/parts like pump tube, suction/discharge tubing, inject check valve, foot ball , adaptor with connecting nut, duck bill, connecting nut, valve o ring,rotor assembly,coil, roller assembly will be measured and paid separetaly.) |
| 18 | Supply only pump tube suitable for item No 17 complete all as specified and directed. |
| 19 | Supplyonly suction/discharge tubing suitable for item No 17 complete all as specified and directed. |
| 20 | Supplyonly inject check valve suitable for item No 17 complete all as specified and directed. |
| 21 | SupplyonlySunction Valve/Foot Valvesuitable for item No 17 complete all as specified and directed. |
| 22 | Supplyonlyadaptor with connecting nut suitable for item No 17 complete all as specified and directed. |
| 23 | Supplyonlyduck bill suitable for item No 17 complete all as specified and directed. |
| 24 | Supplyonlyconnecting nut suitable for item No 17 complete all as specified and directed. |
| 25 | Supplyonlyconnecting valve \"O\" ring suitable for item No 17 complete all as specified and directed. |
| 26 | Supplyonlyrottor assembly with bearing bracket suitable for item No 17 complete all as specified and directed. |
| 27 | Supplyonly oil suitable for item No 17 complete all as specified and directed. |
| 28 | Supplyonlyroller assembly suitable for item No 17 complete all as specified and directed. |
| 29 | Supply and fixing in repair DOL Starter 415Volts, 3-Phase upto 10 HP capacity complete all as specified and directed. |
| 30 | Material and labour for taking up and down and carry to workshop centrifugal pump of capacity 100/75 HP by opening and dismantling from the position for repair/replacement components like bearing roller type, shaft welding and machining work, body asssemble and machining with opening and fitting, chabi machining and fitting, coupling bushing and boring, neck ring policing, nut bolt washers and greasing work andrefixing the same in position for smooth functioning of pumping set and testing at full load complete all as specified and as directed. Note :- Any additional item required to complete the job is deemed to be included in the quantity rate. |
| 31 | All as per Item No 30 here-in-before but of capacity 30 HP complete all as specified and as directed. |
| 32 | All as per Item No 30 here-in-before but of capacity 10/7.5 HP complete all as specified and as directed. |
| 33 | Material and labour for taking up and down & carry to workshop and opening the burnt motor 100/75 HP, 415 Volts and rewinding the same by super enamel copper wire as per existing size/gauge including provision of new insulating material, varnishingand fixing of new ISI make bearing both side and refixing the same in position and testing at full load and commissioning complete all as specified and directed.Note :- Any additional item required to complete the job is deemed to be included in the quoted rate. |
| 34 | All as per Item No 33 here-in-before but of capacity 30 HP complete all as specified and as directed. |
| 35 | All as per Item No 33 here-in-before but of capacity 10/7.5 HP complete all as specified and as directed. |
| 36 | Material and labour for repair/servicing of solar water heater system 250 to 1000 Ltr per day capacity complete all as specified and directed. |
| 37 | Supply and fixing in repair NRV 20 mm dia size suitable for solar water heater 250 to 1000 Ltrper day capacity complete all as specified and directed. |
| 38 | Supply and fixing in repairNRV 25 mm dia size suitable for solar water heater 250 to 1000 Ltr per day capacity complete all as specified and directed. |
| 39 | Supply and fixing in repairHeating Element for solar water heater 250 to 1000 leters per day capacity complete all as specified and directed. |
| 40 | Supply and fixing in repairHot Water Collector for solar water heater 250 to 1000 leters per day capacity complete all as specified and directed. |
| 41 | Supply and fixing in repairETC Washer 47 mmfor solar water heater 250 to 1000 leters per day capacity complete all as specified and directed. |
| 42 | Supply and fixing in repairETC Washer 58 mmfor solar water heater 250 to 1000 leters per day capacity complete all as specified and directed. |
| 43 | Supply and fixing in repair Vacuum Tube 47X1500 mm forsolar water heater 250 to 1000 leters per day capacity complete all as specified and directed. |
| 44 | Supply and fixing in repair Vacuum Tube 58X2100 mm forsolar water heater 250 to 1000 leters per day capacity complete all as specified and directed. |
| 45 | Supply and fixing in repairGasket forsolar water heater 250 to 1000 leters per day capacity complete all as specified and directed. |
| 46 | Supply and fixing in repair Flat plate collectorforsolar water heater 250 to 1000 leters per day capacity complete all as specified and directed. |
| 47 | Supply and fixing in repair Cold Water collectorforforsolar water heater 250 to 1000 leters per day capacity complete all as specified and directed. |
| 48 | Material and labour for taking up and down & carry to workshop and opening the booster pump of capcity of .5 to 2 HP, rewinding the same by super enamel copper wire as per existing size/gauge including provision of new insulating material, varnishingand fixing of new ISI make bearing, repair/replacement of impellers, shaft seals, pressure switch, check valve and pressure tank and refixing the same in position and testing at full load and commissioning complete all as specified and directed.Note :- Any additional item like electronic relays, fuses and switches etc required to complete the job is deemed to be included in the quoted rate. |
| 49 | Supply only OT Solution for chlorine test in 200 ml or nearest size packing complete all as specified and directed. |
| 50 | Supply and fixing in repair cast iron sluice valveof size 350 mm dia with stainless steel spindle and cast iron hand wheel complying with IS 14846-2000, class PN 1.0 both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts and washers of required size & Nos, including taking down old unserviceable CI sluice valve complete all as specified and as directed |
| 51 | Supply, installationtesting and commissioning in replacement ofindoor type LT panel of minimum size 2400X1600X500 mm or as ground requirement totally enclosed weather and vermin proof, suitably ventilated, 440 Volts, 50HZ, AC supply,fully compartamentalised cubical type made out of 3 mm thick CRCA sheet steel for load bearing and2.0 mm thick non load bearing portions, protection ofenclosure IP-54 as per IS-2147 of 1962 complete with pretreatmentand powder coating of approvedcolour including suitable angleiron/flat iron frame work/supports, excavation and earth work, PCC foundation etc, including the following switchgear, suppliedfitted and connected internally complete with bus bar all as directed and specified by Engr-in-charge :- (a)8 Nos copper bus bar of equal size of aluminium conductor with PVC coloured heat shrinkable type sleeves contiuous rating 600 Ampswith CTs , ammeter and volt meter with selector switches , set of LED type indicating lamps R,Y,B on incoming side, extended rotary handles, adon blocks in requisite numbers, aauxiliary contractors, start/stop buttons, star delta timers, single phase preventor, power terminals, nut, bolt washers, door knobs, gasket, lugs, sleeves, insulator, elemex terminals, cable and wires complete. (b) 4 Pole manual on load change over 400 A rating - 01 Nos(c) 4 Pole MCCB415 volt adjustable type, 100 Amps with breaking capacity 25 KA- 04 Nos(c) 3 Pole MCCB 415 volt 63 Amps with breaking capacity 25 KA- 02 Nos (d) 3 Pole Power Contactor 220V AC Coil AC3 duty, 415V AC, 5o Hz, 50 A (Delta) -04 Nos (e) 3 Pole Power Contactor 220V AC Coil AC3 duty, 415V AC, 5o Hz, 18 A (Star) -02 Nos(f) Thermal Overload Relay 22-32 A - 02 Nos(Note: any other item required to complete the job satisfactorily will be ilcluded in quoted rate) |
| 52 | M &L for GI Earthing complete with GIearth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of ditch not less than0.90 m x 0.60 m x 2.25 mtr, below ground level with top edge ofthe plate at a depth not less than 1.5 mtr below ground level, earth plate connected to 4mm dia GI wire,7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers,testing of completion (drawn in earth lead protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSRPart - I connected to earthing lead with Main switch/main control board,filling with charcoal dust , and common salt ,including necessary excavation and earth work in any type of soil ,perforated watering pipe medgrade 20 mm,funnel with wire mesh,earth lead protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 8 mm dia TMT bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directedNote :(i) 7.5 RM GI earth strip deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately.(ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.(iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm top of GI Plate.iv) Earthing test must be carried out in presence of Engr-in-Charge/JE E&M.v) Meggerrequired for testingwill bebe provided at site by the contractor.vi) Contractor shall submit earth resistance testing report before submission of RAR. |
| 53 | Material and labour for painting 100/75/30 HP Centrifugal Water Supply Pump with Motor, Iron Base, Inlet and outlet MS Pipe complete by applying two coats of anti-corrosive paint in differentexisting colours over a coat of red oxide zinc chrome primer after preperation of all exposed to steel surfaces including necessary scraping of rust occured on iron and old corrode paintand writingbasic details like MES No/SM No/Pump No/Motor No etc with white paint complete all as specified and directed. |
| 54 | All as per Item No 76 here-in-before but of capacity 10/7.5 HP complete all as specified and as directed. |
| 55 | Material and labour for repair/replacement of float type water level indicator including all spares like buyant float, guiding mechanism, wire ropes, guiding rods, indication iron plates etc of all existing types and sizes for OHTs of capacity from 0.4 lakh gallon to 3.0 lakh gallon capacity and UGs of capacity 1.5 lakh gallon to 5.0 lakh gallon including necessary arrangements for breathing for human being on job, safety belts, helmets, use and waste shuttering as required, arrangements for climbing up/down to water reservoir and other accessories as required complete all as specified and directed. Note:- The job includes proper testing by trial of one week period to get satisfactoy results of repaired/replaced float type water level indicator. |
| 56 | Supply and fixing in repair CI body and brass gate heavy duty non return valve (NRV) with by-pass arrangement, IS-5312, ISI marked both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & nos complete of size 250 mm dia complete all as specified and directed |
| 57 | All as per item no 56 here-in-before but of size 150mm dia complete all as specified and directed |
| 58 | All as per item no 56 here-in-before but of size 100mm dia complete all as specified and directed |
| 59 | Material and labour for mild steel iron frame/sheet work with suitable angle iron/ flat iron and sheet matching with existing insfrastructure on site providing required size of frame/sheet including welding work, provn of hinges, handle, holdfast and locking arrangements etc as required at site, applying two coats of anti-corrosive paint in any prescribed colour matching with existing insfrastructure over a coat of red oxide zinc chrome primer complete all as specified and directed. (Note: No of welding joints will be made all as directed by Engr-in-Charge) |
| 60 | Supply and fixing in replacement 4 pole terminal of existing make and size or equivalent suitable for panel of 75/100 HP Centrifugal Motor Pump complete all as specified and directed. |
| 61 | Supply and fixing in replacement aluminium bus bar of size 40X10 mm existing make and size or equivalent suitable for panel of 75/100 HP Centrifugal Motor Pump complete all as specified and directed. |
| 62 | Supply and fixing in replacement aluminium bus bar of size 30X10 mm existing make and size or equivalent suitable for panel of 75/100 HP Centrifugal Motor Pump complete all as specified and directed. |
| 63 | Supply and fixing in replacement aluminium bus bar of size 30X05 mm existing make and size or equivalent suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 64 | Supply and fixing in replacement aluminium bus bar of size 25X10 mm existing make and size or equivalent suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 65 | Supply and fixing in replacement aluminium bus bar of size 25X05 mm existing make and size or equivalent suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 66 | Supply and fixing in replacement Easypact TVS contactor of existing make and model (LC1E160) or equivalent suitable for panel of 75/100 HP Centrifugal Motor Pump complete all as specified and directed. |
| 67 | Supply and fixing in replacement of Easypact TVS contactor of existing make and model (LC1E120) or equivalent suitable for panel of 75/100 HP Centrifugal Motor Pump complete all as specified and directed. |
| 68 | Supply and fixing in replacement of Easypact TVS contactor of existing make and model (LC1E18) or equivalent suitable for panel ofCentrifugal Motor Pump complete all as specified and directed. |
| 69 | Supply and fixing in replacement of Easypact TVS contactor of existing make and model (LC1E25) or equivalent suitable for panel ofCentrifugal Motor Pump complete all as specified and directed. |
| 70 | Supply and fixing in replacement of Relay Tesys giga circuit breaker of existing make and model (LRE08A) or equivalent suitable for panel of 75/100 HP Centrifugal Motor Pump complete all as specified and directed. |
| 71 | Supply and fixing in replacement of Relay Tesys giga circuit breaker of existing make and size (07 to 10 Amps) suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 72 | Supply and fixing in replacement of Relay Tesys giga circuit breaker of existing make and size (09 to 13 Amps) suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 73 | Supply and fixing in replacement of timer switch of existing make and model (S1ETS1) or equivalent suitable for panel of 75/100 HP Centrifugal Motor Pump complete all as specified and directed. |
| 74 | Supply and fixing in replacement of aden block of existing make and model (LAEN11) or equivalent suitable for panel of 75/100 HP Centrifugal Motor Pump complete all as specified and directed. |
| 75 | Supply and fixing in replacement of phase indicator in different colours ( red/yellow/blue/green etc) of existing make and model suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 76 | Supply and fixing in replacement of digital ameter of existing make and model (upto 200 amps range) suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 77 | Supply and fixing in replacement of digital voltmeter of existing make and model (upto 500 volts range) suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 78 | Supply and fixing in replacement of selector switch for ameter and voltmeter of existing make and model suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 79 | Supply and fixing in replacement of start/stop switch of existing make and model suitable for starter panel of Centrifugal Motor Pump complete all as specified and directed. |
| 80 | Supply and fixing in replacement of NO/NC switch of existing make and model suitable for starter panel of Centrifugal Motor Pump complete all as specified and directed. |
| 81 | Supply and fixing in replacement of electronic fuse bottle type of existing make and model suitable for starter panel of Centrifugal Motor Pump complete all as specified and directed. |
| 82 | Supply and fixing in replacement of electric glands of existing make and model suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 83 | Supply and fixing in replacement of panel nobes of existing make and model suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 84 | Supply and fixing in replacement of steel lock for panel of existing make and model suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 85 | Supply and fixing in replacement of copper lugs of existing make and size ( 25 mm )suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 86 | Supply and fixing in replacement of copper lugs of existing make and size ( 35 mm )suitable for panel of Centrifugal Motor Pump complete all as specified and directed. |
| 87 | Supply and fix in replacement MCCB 415 volts 3 Pole 250 Amps 50 Hz with thermal adjustable and magnetic adjustable breaking capacity 36 KA complete all as specified and directed at site. |
| 88 | Supply and fix in replacement MCCB 415 volts 4 Pole 200 Amps 50 Hz with thermal adjustable and magnetic adjustable breaking capacity 36 KA complete all as specified and directed at site. |
| 89 | Supply and fix in replacement MCCB 4 Pole 415 volts 160 Amps 50 Hz with thermal adjustable and magnetic adjustable breaking capacity 36 KA complete all as specified and directed at site. |
| 90 | Supply and fix in replacement MCCB 4 Pole 415 volts 100 Amps 50 Hz with thermal adjustable and magnetic adjustable breaking capacity 25 KA complete all as specified and directed at site. |
| 91 | Supply and fix in replacement on load change over switch of capacity 400 Amps complete all as specified and directed at site. |
| 92 | Supply and fix in replacement on load change over switch of capacity 200 Amps complete all as specified and directed at site. |
| 93 | Supply Only Calcium Hypo Chloride minimum 65 % chlorinecomplete all specified and directed. |
| 94 | Supply only lead wool complete all as specified and as directed. |
| 95 | Supply only lead Pig complete all as specified and as directed. |
| 96 | Supply only Spun Yarn complete all as specified and as directed. |
| 97 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |