| 1 | Taking down carefully copper/ aluminum point wiring (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder, regulators, sockets light fittings etc, removing material to store for keeping in safe custody or for taking credit, and making good disturbed surface of walls, floors, etc. complete all as specified and directed by Eng-In-Charge. |
| 2 | M&L for point wiringfor modular accessories with modular metal flush box and cover plate with frame of suitable size complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLScable 1100 volts grade drawn throughmetallic rigid / PVC heavy duty concealed conduit/ casing capping/open coduit with 1.5 sqmm, single core, PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade as earth continuity wire terminated in new modular sunken boxes and modular metal flush box as required size at site incl all connected accessories, box made from not less than 1.6mm GI sheet factory made complete all as specified and directed by Eng-In-Charge. for one light controlled by one switch complete |
| 3 | S&F Modular switch one way 6A, 1 Module, complete all as specified and directed by Eng-In-Charge. |
| 4 | Supply and fixingin replacement for LED tube light fittings 1x20Watts, 230 volts surface and wall mounted LED type,extruded thermoplastic body with polycarbonate diffuser & integrated electronic driver complete with all accessories internally pre wired and including connection up with twin core twisted flexible copper conductor cable of size 1.5 sqmm and flexible pipe of white colour from ceiling rose to light complete all as specified and directed by Eng-In-Charge. |
| 5 | Supply and fixingin replacement for LED light fittings 1x10Watts, single side connection 230 volts surface and wall mounted LED type complete with all accessories internally pre wired and including connection up with twin core twisted flexible copper conductor cable of size 1.5 sqmm and flexible pipe of white colourfrom ceiling rose to light complete all as specified and directed by Eng-In-Charge. |
| 6 | Supply and fixing in replacement for Pluto Panel surface/recess mounted2\"x2\", 36 watt 230 v, 50 Hz, 120 lm/W, smart colour temperature, CCT controllable with remote control with dimming and CCT changes from 2700k to 6500 k housing having CRCA coated which provides soft-light and glare free symmetrical illumination including connection up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 7 | Supply, testing and commissioning of PIR ceiling mounted lighting management sensor detection range 360 working temperature 0 to 40 degree C power source 220-240 V /AC ,working humidity <93% RH rated load upto 2000 w ambient light <3-2000 lux (adjustable ) detection distance Max 8m power consumption 0.5 w time delay 10 sec ± 3 sec to 30 min ± 2 min (adjustable) optimum distance between sensors 6 meter installation height 2.5 m to 6 m, IP 41/54 including providing suitable pvc cable and PVC pipe and suitable relay as per site requirement, provision of automatic switch on and off the lighting loads as per presence of occupancy by complete all as specified and directed by Eng-In-Charge. |
| 8 | Supply and fix in replacement recess mounted circular LED slim fit low profile down lighter of capacity 18/20 watt complete all as specified and directed by Eng-In-Charge. |
| 9 | S&F in replacementLED 18 watt cool white/warm white, surface mountedround/square shape down light with white powder coated polycarbonate housing and pressure dicast heat sink having high efficiency complete all as specified and directed by Eng-In-Charge. |
| 10 | Supply and fix in replacement LED security light 45 watt, 240 voltIP 65 protection , weather proof with all other accessories complete all as specified and directed by Eng-In-Charge. |
| 11 | S&F in repair/replacement LED flood light, suitable for focasing oftree / buildings of capacity 200 watt,240 volt, 50 HZ complete all as specified and directed by Eng-In-Charge. |
| 12 | S&Fin repair/replacement LED flood light , suitable for focasing oftree / buildings of capacity 150 watt, 240 volt, 50 HZ complete all as specified and directed by Eng-In-Charge. |
| 13 | S&Fin repair/replacement LED flood light , suitable for focasing oftree / buildings of capacity 100 watt, 240 volt, 50 HZ complete all as specified and directed by Eng-In-Charge. |
| 14 | S&Fin repair/replacement LED flood light, suitable for focasing oftree / buildings of capacity 50 watt, warm white or cool white, 240 volt, 50 HZ complete all as specified and directed by Eng-In-Charge. |
| 15 | S&Fin repair/replacement LED flood light , suitable for focasing oftree / buildings of capacity 30 watt, warm white or cool white, 240 volt, 50 HZ complete all as specified and directed by Eng-In-Charge. |
| 16 | Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc complete all as specified and directed. |
| 17 | M & L for dry Sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and directed.Note: - Thickness after punning will be measured for payment. |
| 18 | Supply andlaying un-reinforced precast concrete cable cover, Class LV , Type 1, flat, size 250mm x 150mm x 40mmcomplete as directed |
| 19 | Returning, filling including spreading, leveling watering & well ramming in laying not exc. 25cm for not exc. 25 cm thick for soft/ loose soil complete all as specified and directed. |
| 20 | Removal of excavated material at a distance notexc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point for soft/loose soil complete all as specified and directed. |
| 21 | Supply,laying and testing ofcable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sqmm 3.5 core complete all as specified and directed. |
| 22 | Supply,laying and testing ofcable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core complete all as specified and directed. |
| 23 | M&L for Laying in trenches in road cross / floorstube galvanished iron light grade 80 Bore with all fittings for protection of cable complete all as specified and directed. |
| 24 | Labour onlyfor boring under road/drain by manual method for inserting the light grade pipe GI tubing up to 200 mm dia cable protection complete all as specified and directed by Engineer In Charge. |
| 25 | Supply, installation, commisioning and testing factory made and tested, CPRI approved,LT Panel(KISOK), outdoor type, mounted on rigid angle iron frame, suitable size, having independent compartment forinsulated Aluminium bus bar, incoming feeder and each out going feeder, dust and vermin proof, factory made, fabricated out of not less than 3.00 mm thick CRCA sheetsuitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminium bus bar of600 Amp rating for 3 phase and neutal4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set, common earth bus bar ofGI Strip 32 x 6 mm at bottom with panel board at two earth terminals , cable glands with independent plates at bottom for each out going and in coming cables in cable alley and complete board painted with powder coatingin siemens grey colourfront & rear opening type with double door shutter and locking arrangement including provision of 65 mm Godrej (freedom) lock with 2 keys, suitable aprons for cable entry/exist including taking down and refixing of exisiting cable properly with lug and thimable, Rate including for removal and taking out existing old/rusted LT Panel board of any type any size complete all as approved andcomprising as under: - |
| 26 | Incoming :- (a) ON load change over switch of 400 Amp Capacity- 01 No(b) MCCB 4 Pole, current rating 400 Amp, With Thermal Magnetic release, breaking capacity 35 kA at 415V, 50Hz- 01 Nos.(c)Digital voltwith selector switch.-01 set. (d)DigitalAmp meter with selector switch.-01 set.(e)Neon indicating lamps (R, Y & B) -01` Set. Out going :- (a) MCCB 4 Pole, current rating 250 Amp, With Thermal Magnetic release, breaking capacity 25 kA at 415V, 50Hz - 02 Nos.(b) MCCB 4 Pole, current rating 200 Amp, With Thermal Magnetic release, breaking capacity 25 kA at 415V, 50Hz - 02 Nos.(c) MCCB 4 Pole, current rating 160 Amp, With Thermal Magnetic release, breaking capacity 25 kA at 415V, 50Hz - 02 Nos.(d) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legsand made out of ISA5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.(e) M & L for necessary excavation and as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job |
| 27 | M & L for Earthing complete in repairs with galvanised steel earthelectrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth leadas eGI strip of 32X6mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed.Note: (i)Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any addition in length shall be adjusted through deviation order.(ii) Necessary excavation wk is included in this item. |