| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for foundation. (Laying of under ground cables) in hard/dense soil and getting out all as directed. |
| 2 | Excavation in trenches exceeding 1.5 m wide and not exceeding 3.0 mtr in depth for foundation. (Laying of under ground cables) in hard/dense soil and getting out all as directed. |
| 3 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for foundation. (Laying of under ground cables) in hard rock and getting out all as directed. |
| 4 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well rammingin layers n. exc. 25 cm thick complete all as specified and directed. |
| 5 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 6 | M&Lfor dry sand filling in trenches around under ground cable complete all as specified and directed. |
| 7 | M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required. |
| 8 | Material and labour for laying DWC (Double wall corrugated) pipe conforming to IS 16205 (electric cable use) of nominal outer dia 50 mm and inner dia 38mm for laying electrical cables under trenches / under road/ wall complete all as specified and directed. |
| 9 | M&L for cutting of PCC/Hard standing/WBM road not exceeding 45 cm in width & not exceeding 60 cm in depth for passing of cable and making good of disturbed surface to match with the existing surface complete all as specified and directed . |
| 10 | M & L forPCC 1:3:6 (nominal mix) type C-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concreteincluding necessary frame work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site. |
| 11 | Supply and fix in replacement oflight gradeGalvanised iron pipe 80mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitablemild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable proction.(Note:- Excavation & earth work shall be measured and paidfor separately under appropriate item of this schedule ):- Make :- Jindal/TATA/Prakash surya |
| 12 | All as per Item No 11 here-in-before but of size 50 mm bore |
| 13 | Ditto- all as per Item No 11 here-in-before but of size 40 mm bore |
| 14 | M&L PCC Coping for, steel tubular poles new and old (1:2:4) Type B-1 using 20 mm graded aggregate for coping of poles including necessary form work complete allas specified and directed at site. |
| 15 | Supply and fix, laying & Testing by removing existing unsv aerial bunch cable cable 1100 volt grade stranded and aluminiumconductor 4 core x 70 Sqmm, (three phase and one neutral), 50 Sqmm (insulated messenger) , electric power cables (heavy duty) 1100 volts grade withstranded aluminum conductor including all fittings such as anchor clamp,suspension clamps,inline connector,cable protection and dead construction, in cluding taking down unserviceable cable all as per IS or as specified & directed. |
| 16 | Supplyand fix in replacement of existing unsv cable, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade withstranded aluminum conductor of size 120 sqmm 3.5 core all as per IS, specified & directed. |
| 17 | All as per Item No 16 here-in-before but of size 95 Sqmm 3.5 core |
| 18 | All as per Item No 16 here-in-before but of size 70 Sqmm 3.5 core |
| 19 | All as per Item No 16 here-in-before but of size 50 Sqmm 3.5 core |
| 20 | All as per Item No 16 here-in-before but of size 35 Sqmm 3.5 core |
| 21 | All as per Item No 16 here-in-before but of size 25 Sqmm 4 core |
| 22 | All as per Item No 16 here-in-before but of size 10 Sqmm 4 core |
| 23 | All as per Item No 16 here-in-before but of size 16 Sqmm 2 core |
| 24 | All as per Item No 16 here-in-before but of size 10 Sqmm 2 core |
| 25 | S&F in replacement of cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5/4 core. Make :- 3M/ Raycem/ Denson |
| 26 | All as per item No 25 but for 25 to 50 Sqmm size. |
| 27 | All as per item No 25 but for 70 to 150 Sqmm size. |
| 28 | S&F in replacement of Off Load Change Over Switch (Manual change over in sheet enclosure) with sheet steel enclosure fixed over wall / panel etc. of rating 200 Amps, 415 Volts, 4 pole withcomplete with sheet steel enlcosure all as specified and directed by Engineer in Charge. |
| 29 | Taking out under ground, LT cables, different sizes, by excavation and earth work in any type of soil, removing bricks or PCC tiles of any size, re-laying in the same trenches or re-routing after rectification of fault as required complete all as specified and directedNOTE:- (i) Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separetely.(ii)Retrieved serviceable bricks or PCCcable cover/Bricks and sandshall be re-laid on the cable & the cost for the same is deemed to be included in the unit rate. |
| 30 | Supply and fix inreplacement of 1100 Volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size of aluminum conductor 10 sq mm stranded conductor all as specified and directed. |
| 31 | Supply and fix in replacement, errecting of steel tubular poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long)including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellowpaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\" (inch) wide complete all as specified and directed. Make : India Co. Ltd Jamshedpur/ Fabrico(India) Pvt Ltd Meerut/National TubingCo. KanpurNote: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. |
| 32 | M & L in replacement ofACSR conductor of size 6/1 x 2.59(Weasel) and6/1 x 2.11 (Squirrel) ISI marked for LT over head lines on poles including stretching, tightining of poles insulator with winding wire of suitable size with insulator/strechingof ACSR conductor all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fix in replacement of cradles, hexagonal/rectangular, fabricated with galvanised steel wire4 mm dia as in repairs complete all as specified and directed. |
| 34 | Dismantling, cross arms, clamps, supports made of channels or angle section etc including nuts and bolts and setting aside all as required at site or directed. |
| 35 | Supply and fix in replacement of mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections as ordered including necessory nuts, bolts, washers , welding, bending, cold or hot , drilling holes for bolts , in any shape or size as indicated or directed with and including preparations of new steel surfaces& applying two coats ofaluminiumpaint overone coat ofred oxide Zn Chrome primer complete all as specified. |
| 36 | Supply and fix in replacement of Pin type insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65 mm dia for 1100 volt grade. |
| 37 | Supply and fix in replacement of Insulator shackletype porcelain vitreous, white brown or green 100mm height and 115 mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nutfor conductor working pressure 1100 volt grade complete. |
| 38 | Supply and fix in replacement of Loop insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mmx 140mm, clearance of hole 25.5 mm, Complete all as specified and directed. |
| 39 | M&L for Earthing complete with GI earth plate electrode ofsize 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to GI strip 32 x 6 mm size drawn through 40mm GI light grade pipe and including providing 15mm bore GI pipe medium grade as water pipe with suitable size funnel, as earthing lead filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC(1:3:6) type C1 using 20mm graded stone aggregate and PCC cover made with PCC (1:2:4) type B1 using 20mm graed stone aggregate reinforced with 8mm TMT bar @ 100mm c/c alongwith lifting handle of 8mm dia steel bar complete all as shown and specified in electrical plate no.3 of SSR Part-I (2009) all as directed.(Note:GI strip upto 7.5 m length in included in unit rate quoted by contractor). |
| 40 | M & L for cutting, trimming of branches along the OH conductor of LT/ HT line within 2 mtr distance along both side of line and strictly all branches in one place as directed by Engineer-in-Charge. |
| 41 | M & L for Re-streching of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors andaddingnew length( if required) in placeof old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire all as specified.( Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge) .Note:- Five lines together will bemeasured as one span from pole to pole. |
| 42 | M & L for Painting topoles (9/11 mtr long) including cross arms, \"V\" brackets, \"D\" clamps, nuts, bolts,complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed |
| 43 | Supply,installing, testingand commissioning Outdoor type LT feeder piller box to accommodate the under mentioned accessories, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double door, front side openable, type IP 54 protection made of CRCA sheet 3.15 mm thick of size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including dismantling old unsv LT feeder piller box / busbar chamber etc complete with the following items housed in :-BUSBAR :- 630 Amps rated copperbus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulatorbus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar).INCOMING:- (i)4 pole MCCB of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal megnatic release type - 01No. (ii) Digital multifunctinal meter V, A, F, KW- 01 No. |
| 44 | (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set(iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 200 Amp, breaking capacity 25 KA with thermal magnetic release - 02 Nosa) 2 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with thermalmagnetic release, adjustable type e - 04 Nos. |
| 45 | S&F in repair Bus bar chamber with door type of size 400 x 380 x 190 mm made out of MS sheet 3mm thick with Copperbus bar three phase & neutral each 320 x 20 x 6 mm of size fixed on insulators and fixing on steel pole with proper clamps, nuts , bolts & washers of required size and making connection of LT cables with thimbles, glands and making good the disturbedsurfaces incl water proof PVC sticker like danger mark all as required at site. |
| 46 | Supply and fix in replacement of aluminium strip 25 x 3.15 mm with saddles and fixing screws, insulators rawal plugs etc forconductor for roof and fixed on wall upto test point all as specified. |
| 47 | Supply and fix in replacement of galvanized iron strip 32 x 6 mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground /drawn into hume pipe. NOTE : Excavation & earth work shall be measured and paid for seperately under relevant item of schedule. complete all as specified and directed. |
| 48 | Supply and fix in replacement of wooden block heavy weight of size 30x30x30 cm with hole of 20 cm for fixing of air termination rod of any size incl dismantling and taking down old existing unserviceable wooden block complete all as specified and directed. |
| 49 | Supply and fix in replacement of GI tubes light grade, galvanised, 20 mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for fixing of air terminationincl dismantling and taking down old existing unserviceable GI tubes lightgrade complete all as specified and directed. |
| 50 | Supply and fix in replacement of five pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed. |
| 51 | Supply and fix in replacement of Test point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point completed all as specified. |
| 52 | Supply, fix in replacement, connecting and testing of MCCB 100 Amps and 25 KA 4 pole. |
| 53 | Supply, fix in replacement, connecting and testing of MCCB 63 Amps and 25 KA 4 pole. |
| 54 | Supply, fix in replacement, connecting and testing of MCCB 315/320 Amps and 36 KA 4 pole.Make |
| 55 | Supply, fix in replacement, connecting and testing of MCCB 250 Amps and 36 KA 4 pole. |
| 56 | Supply, fix in replacement, connecting and testing of MCCB 200 Amps and 36 KA 4 pole. |
| 57 | Supply, fix in replacement, connecting and testing of MCCB 160 Amps and 25 KA 4 pole. |
| 58 | Supply and fixin replacement cable lug suitable for 10 Sqmm cable with made of copper including nut,bolt and washer complete all as specified and directed..Make:Dowells/AXIS/INDIAN |
| 59 | Supply and fixin replacement cable lug suitable for 16 Sqmm cable with made of copper including nut,bolt and washer complete all as specified and directed..Make:Dowells/AXIS/INDIAN |
| 60 | Supply and fixin replacement cable lug suitable for 25 Sqmm cable with made of copper including nut,bolt and washer complete all as specified and directed.Make:Dowells/AXIS/INDIAN |
| 61 | Supply and fixin replacement cable lug suitable for 35 Sqmm cable with made of copper including nut,bolt and washer complete all as specified and directed.Make:Dowells/AXIS/INDIAN |
| 62 | Supply and fixin replacement cable lug suitable for 50 Sqmm cable with made of copper including nut,bolt and washer complete all as specified and directed.Make:Dowells/AXIS/INDIAN |
| 63 | Supply and fixin replacement cable lug suitable for 70 Sqmm cable with made of copper including nut,bolt and washer complete all as specified and directed.Make:Dowells/AXIS/INDIAN |
| 64 | Supply and fixin replacement cable lug suitable for 95 Sqmm cable with made of copper including nut,bolt and washer complete all as specified and directed.Make:Dowells/AXIS/INDIAN |
| 65 | Supply and fixin replacement cable lug suitable for 120 Sqmm cable with made of copper including nut,bolt and washer complete all as specified and directed.Make: Dowells/AXIS/INDIAN |
| 66 | Supply and fixin replacement cable lug suitable for 150 Sqmm cable with made of copper including nut,bolt and washer complete all as specified and directed.Make:Dowells/AXIS/INDIAN |
| 67 | Supply and fixin replacement Anchor clamp suitable for 70 Sqmm to 95 Sqmm cableas per site requirment complete all as specified and directed. Make:Sintex/Hansel/Legrand |
| 68 | Supply and fixin replacement Suspension clamp suitable for 70 Sqmm to 95 Sqmm cableas per site requirment complete all as specified and directed. Make:Sintex/Hansel/Legrand |
| 69 | Supply and fixin replacement inline connector suitable for 70 Sqmm to 95 Sqmm cableas per site requirment complete all as specified and directed. Make:Sintex/Hansel/Legrand |
| 70 | Supply and fixin replacement cable protection suitable for 70 Sqmm to 95 Sqmm cableas per site requirment complete all as specified and directed. Make:Sintex/Hansel/Legrand |
| 71 | Supply and fixin replacement dead construction suitable for 70 Sqmm to 95 Sqmm cableas per site requirment complete all as specified and directed. Make:Sintex/Hansel/Legrand |
| 72 | Supply and Replacement in repair of Stay assembly complete with accessories i.e stay plate 300mm x 300mm x 6mm,16 mm dia stay rod, galvanized thimbles, G.I. stay wire 7/4 SWG, loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No.1 on Ser Page No.19-47 of MES Schedule Part-I complete. Note : Stay clamp, excavation and earth work and concrete for stay pit and insulator shall be measured and paid for separately. |
| 73 | Repair, maint and of broken doors for LT panel and bus bars by welding and incl fixing ofnew hinges and other material as required at site complete all as specified and directed. |
| 74 | Supply and fix in replacement of High power LED street light 60 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium roadway luminaire with high power LEDs as light source and electronic driver fixed on pole/wall along with service bracket as per sample, clamps as directed, nuts, bolts, and washers as directed incl electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated from junction box to street light by laying in bracket/ pipe/ pole complete all as specified. Make : Havells/Surya/Bajaj |
| 75 | Supply andinstallation, connecting eclectically & commissioning in replacement of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxidecomplete with 200 amps rated copper bus bar suitable for 3 phase 4wire supply system duly drilled holes and makingall cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 200 Amps 4 pole 415 Volt, 35/36 KA. |