Tender For Electrification Work In The National Highway Block Office Building Of Lakhimpur Kheri District - Wiring for light point/fan point/exhaust fan point/call bell point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with moduler switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core e.t.c as required. Group B As per DSR no.-1.10.2 2 Wiring for twincontrol light point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core in surface/ recessed medium class PVC conduit, 2 way module switch, module plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core e.t.c as required. As per DSR no.-1.11 3 Wiring for circuit/ submain wiring along withearth wire with the following sizes of FRLS PVC insulated copper conductor single corecable in surface/ recessed medium class PVC conduit, as required. 4 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire As per DSR no.-1.14.1 5 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire As per DSR no.-1.14.2 6 2 X 4 sq. mm + 1 X 4 sq. mm earth wireAs per DSR no.-1.14.3 7 2 X 6 sq. mm + 1 X 4 sq. mm earth wireAs per DSR no.-1.14.4 8 2 X 16 sq. mm + 1 X 6 sq. mm earth wireAs per DSR no.-1.14.6 9 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch , connections etc. as required. As per DSR no.-1.29 10 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch , connections etc. as required.As per DSR no.-1.30 11 Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type.Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA C Curve. Cubicle type switch board shall be Cat-A and B only.Incoming 200Amp.MCCB-1 NoOutgoing 63 Amp. MCCB-04 Nos. 12 Supplying and fixing following ways,4 ways (4+12), Double door and 4 way Double door TPN MCBDBhorizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)As per DSR no.-2.4.1 13 Supplying and fixing following way Double door SPN MCBDB single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)As per DSR no.-2.3.3 14 For 12 way, Double door 15 Supplying and fixing 63 A rating, 4 pole, 415V,MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 16 Supplying and fixing 40 A rating, two pole, 240V/415V,MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 17 Supplying and fixing 63 A rating, two pole, 240V/415V,MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 18 Supplying and fixing of following current rating, B curve 10KA Single pole, 240V/415V,MCB in the existing DB complete with connections, testing and commissioning etc. as required. 19 40 A 20 63 A 21 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of Single poles in the exixting MCB DB complete with connections, testing and commissioning etc. as required.As per DSR no.-2.10.1 22 Supply and fixing DP Sheet steel enclosure on surface/recess along with 25/32 Amp. 240 V C Curve DP MCB Complete with connections , Testing & Commissioning.As per DSR no.-2.16 23 Earthing with G.Iearth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metrelong etc. with charcoal/coke and salt as required.As per DSR no.-5.4 24 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required.As per DSR no.-5.7 25 Supplying and Laying 25 mmx 5 mm G.I Strip at 0.5 Meter below ground as strip earth electrod , including Connection / Termination with G.I nut, Bolt, Spring , washer etc as required As per DSR no.-5.9 26 Supplying and fixing of Wall fan 400mm Sweep 27 S/F Exhaust Fan 300mmsweep metallic 28 Supply and Fixing of Hexagonal / Round G.P fan box of Approved make 29 Supplying, Installation, Testing andCommissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos, canopies, shackle kit, safty rop, copper winding, Power factor not less than 0.9, Service value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 347-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temprature rise =75 degree C(max.), insulation resistance more than 2 mega phm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.As per DSR no.-19.1 30 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.As per DSR no.-1.38 31 Supplyand fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22watt suitable for up to 1x22watt LED Polycarbonate tubelight complete Including tube suitable for bothsurface & suspended complete in all respect. 2620 system lumens, >120 Lm/W, PF>0.95, THD <10%, CRI>80, sheet thickness min 0.8mm, Tube with aluminium heat sink,>300V over voltage protection, 2.5 KV internal Surge Protection, with 5year warrantee.CAT AAAAs per DSR no.-23.07 32 S/O of LED Bulb 15W/17W 33 Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughend glass/ UV stabilized PC Cover and lenses suitable for 110 Watt to 130 Watt and Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved complete in all respect includingLabour.13200-15600 system lumens, High Power LED with lenses, 120 Lm/W, PF>0.95, THD <10% at full load, CRI >70, Potted driver Set in Metal housing (Not Circuitory), Phase to phase Protection at 440V & >300V auto cut and re-start feature, 4KV internal Surge protection, with 5 years warrantee.CAT AAAAs per DSR no.-23.13 34 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade on wall surface as directed by the Engineer-Incharge, complete in all respect. including excavation & refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.As per DSR no.-20c.1.10 35 S/O of 25 sqmm 3-1/2 core armoured cable. 36 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by engineer - incharge complete in all respect.including excavation & refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.As per DSR no.-20a.1.16 37 S/O of 150sqmm 3-1/2 core armoured cable. 38 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheated/XLPE aluminium conductor cable of 1.1 KV grade as required 39 25 sq. mm 3-1/2 core As per DSR no.-9.1.20 40 150 sq. mm 3-1/2 coreAs per DSR no.-9.1.26 41 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 42 Supplying and Laying of 1800mm x 900mm x 12mm thick Rubber mating of Tested Quality