| 1 | SH: RCC WORK |
| 2 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 3 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 5 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 6 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 8 | Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 9 | SH: ROOFING |
| 10 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 11 | 110 mm diameter |
| 12 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 13 | Bend 87.5° |
| 14 | 110 mm bend |
| 15 | Shoe (Plain) |
| 16 | 110 mm Shoe |
| 17 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 18 | 110 mm |
| 19 | SH: FINISHING |
| 20 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 21 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 23 | One or more coats on old work |
| 24 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 25 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 26 | SH: REPAIRS TO BUILDING |
| 27 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead : |
| 28 | With cement mortar 1:4 (1cement: 4 coarse sand). |
| 29 | Renewing glass panes, with wooden fillets wherever necessary: |
| 30 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 31 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \"S\" or \"P\" trap including dismantling of old WC seat and \"S\" or \"P\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. |
| 32 | Orissa pattern W.C Pan of size 580x440 mm |
| 33 | Providing & fixing single scaffolding system on the exterior side of building made with 50 mm dia (approx) bamboo tree 1.00 metre centre to centre horizontal & vertical for repair of projected roof maintaining it in a serviceable condition for the required duration as approved and removing it there after complete as per direction of Engineer-in-charge. |
| 34 | Taking out existing wooden door shutter shutters, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 35 | SH: DISMANTLING & DEMOLISHING |
| 36 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. |
| 37 | SH: SANITARY INSTALLATION |
| 38 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 39 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. |
| 40 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 41 | 10 litre capacity - White |
| 42 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 43 | Semi rigid pipe |
| 44 | 32 mm dia |
| 45 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 46 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 47 | 100 mm inlet and 100 mm outlet |
| 48 | Sand cast iron S&S as per IS: 3989. |
| 49 | SH: WATER SUPPLY |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 51 | 20 mm nominal outer dia pipes. |
| 52 | 25 mm nominal outer dia pipes. |
| 53 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. |
| 54 | 25mm nominal bore, weighing not less than 62 gms |
| 55 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 56 | 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 57 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 58 | 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 59 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 60 | 15mm nominal bore, 107 mm long. Weighing not less than 110 gms. |
| 61 | SH: REPAIRS & REHABILITATION |
| 62 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. |
| 63 | 75mm average thickness |
| 64 | 50 mm average thickness |
| 65 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge |
| 66 | Bars upto 12 mm diameter |
| 67 | Bars above 12 mm diameter |
| 68 | Replacement of sufficiently damaged reinforcements or providing additional reinforcements with the damaged reinforcements by welding etc. includingcost of reinforcement (TMTbar of required dia), mobilization etc. complete as per direction of Engineer-in-Charge. (work is to be executed upto 20 m heights above G.L). |
| 69 | Repairs of damaged RCC portion in beams, columns floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 70 | 75 mm average thicknes |
| 71 | 50 mm average thicknes |
| 72 | Plastering in cement mortar 1:3 (1 cement:3 fine sand) of 6 mm thick admixed with water proofing compound of approved make such as plastocrete super or equivalent confirming to IS 9103-1999,IS 2645-1975 and ASTM C-494-86 Type A @ 0.2% by weight of cement and as per manufacturer specification complete to improve water tightness and workabilitywithout increased water contentand as per direction of Engineer in Charge.(work is to be executed upto 20 m heights above G.L). |
| 73 | Extra for providing & fixing liquid intgral water proofing materials conforming to IS: 2645 of the approved brand such as ROFF HYPROOF/LATICRETE or equivalent at the rate of 140ml/50kg bag of cement or in proportion as recommended by the manufacturer in RCC/CC/Cement mortar etc. as per direction of Engineer-in-charge. (Note: Integral liquid water proofing material shall be added in the water needed for preparation of RCC/CC/Mortar etc.) |
| 74 | SH: MISCELLANEOUS WORK |
| 75 | Cleaning & clearing of choked W.C pan as per direction and satisfaction of Engineer-in-charge. |
| 76 | P/F PVC water storage tank cover of standard quality with lockingarrangement as per direction and satisfaction of Engineer-in-charge. |