}

Tender For Completion Of Incomplete Works For Provision Of Certain Technical Work Services Under Ge Af Amla, Betul-Madhya Pradesh

Military Engineer Services has published Tender For Completion Of Incomplete Works For Provision Of Certain Technical Work Services Under Ge Af Amla. Submission Date for this Tender is 29-08-2025. Electrification Work Tenders in Betul Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50339873
Tender For Completion Of Incomplete Works For Provision Of Certain Technical Work Services Under Ge Af Amla
Tender
Indian
Madhya Pradesh
Betul
29-08-2025

Tender Documents

Tender Details

Completion Of Incomplete Works For Provision Of Certain Technical Work Services Under Ge Af Amla; 1 Lumpsum price worked out by the contractorfor “BUILDINGS AND STRUCTURES” as listed in Sch A part I above/below the lumpsum price of Rs.2,41,60,000.00 as inserted by MES for Sch ‘A’ part I on srl page No. 31 2 Lumpsum price worked out by the contractorfor “SITE CLEARANCE/ EARTHWORK” as listed in Sch ‘A” part II above/below the lumpsum price of Rs.18,94,947.41 as inserted by MES for Sch ‘A’ part II on srl page No.32 3 Lumpsum price worked out by the contractorfor “REPAIR TO PROTECTION WALL NEAR BLDG NO. 99” as listed in Sch ‘A” part III above/below the lumpsum price of Rs. 94,319.65 as inserted by MES for Sch ‘A’ part III on srl page No.33 4 Lumpsum price worked out by the contractorfor “LIGHTENING PROTECTION” as listed in Sch ‘A” part IV above/below the lumpsum price of Rs. 47,107.38 as inserted by MES for Sch ‘A’ part IV on srl page No.34 5 Lumpsum price worked out by the contractorfor “ROAD/PATH/HARDSTANDING as listed in Sch ‘A” part V representing above/below the lumpsum price of Rs. 19,62,315.17 inserted by MES for Sch ‘A’ Part V on srl page No.36 6 Lumpsum price worked out by the contractorfor “EXTERNAL ELECTRIC SUPPLY as listed in Sch ‘A” part VI representing above/below the lumpsum price of Rs. 65,617.50inserted by MES for Sch ‘A’ Part VI on srl page No.37 7 Lumpsum price worked out by the contractorfor “AREA DRAINAGE” as listed in Sch ‘A” part VII representing above / below the lumpsum price of Rs. 31,42,439.12 as inserted by MES for Sch ‘A’ Part VII on srl page No.38 8 Lumpsum price worked out by the contractorfor “RETANING WALL” as listed in Sch ‘A” part VIII representing above / below the lumpsum price of Rs. 6,45,140.05 as inserted by MES for Sch ‘A’ Part VIII on srl page No.39 9 Lumpsum price worked out by the contractorfor “DEMOLITION/DISMANTLING” as listed in Sch ‘A” part IX representing above / below the lumpsum price of Rs.9,85,710.77 as inserted by MES for Sch ‘A’ Part IX on srl page No.40 10 SCH A PART X (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Sch A Part-II. 11 (A) INTERNAL ELECTRIFICATION 12 Material & Labour for using approved colour coding as per IS with flameproof point wiring concealed in wall/ ceiling / roof with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathedmulti stranded copper conductor of size 1.5 Sqmm(nominal area) PVC (FRLS) , 1100 volts grade drawn in and including ISI marked (IS 9537 Part II) of latest edition ERW stove enamelled, rigid steel conduit (metallic)not less than 20 mm dia with allflame prooffittings such as junction boxes, bends, tee, elbow etc all as per relevant IS and type tested/ approved by CMRI Dhanbad fixed with solid backed distance saddles & nettle fold GI screws all as specified including one runof 1.5 sqmm PVC insulated multistranded copper conductor of 1100volts gradefor continuous earthing for one light point/fan pointcontrolledby one no. FLP rotary switch complete all as specified and directed. Note : Flame proof accessories included in quoted rate except BOQ item no. 10.06 13 All as per item No 10.01 here in before with 4 sqmm size cable for one 3 pin 5/15A socket outlet on independent board complete all as specified and directed. 14 Material & Labourfor sub main wiring concealed in wall/ ceiling / roof with necessary fixing arrangements using approved colour coding as per IS with single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked drawn through ISI marked (IS 9537 Part II) of latest edition ERW stove enamelled rigid steel conduit suitable forwiring, suitable for wiring not less than 32mmwith all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc and making good the disturbed surface for 4 runs of 6sqmm size main cable and two runs of 6 sqmm size of earth continuity conductor complete all specified and directed. Note : Flame proof accessoreis shall be measured and paid separately ) 15 Supply & Fix Flame proof switch /isolator cast iron body 16A single pole ON/OFF, 240 volts LM-6 (rotary type) certified by CMRI and confirming to IS 2148 allcomplete as specified and directed. 16 Supply & Fix Flame proof,wheather proof switch socket & plug combined in LM 6 aluminum alloy housing 16 Amp, 240 volts 2 Pole+ Earth combined complete all as specified and directed. 17 Supply & Fixflame proof weather proof threaded type junction box LM 6 aluminum alloy 3 to 4 way complete with closing plug complete all as specified and directed. 18 Supply & Fix CMRI certified LED Flameproofweatherproof tube light fitting 2x16/20W with LM 6 aluminum alloy lamp housing , heat resistant and toughened glass, coverhinges cover with neoprene gasket, painted MS bar guard, epoxyfinish provided with built in controlgear box complete with all accessories internallyprewired& eye bolt for suspension, IP65 Protectioncomplete as specified and directed. 19 Supply & Fix CMRI Certified LED flameproof weather proof40 Watt integral bulkhead/well glass Luminarieswith heat resistant toughened flatglass cover, LM 6 aluminum housing complete with inbuilt control gear complete all as specified and directed. 20 Supply & Fix Flame proof weather proofexhaust fanof size 15 1440 RPM,CFM 2350, totally enclosed including fixing as per standard complete suitable for hazardous locations of zone 1&2,Exd with relevant IS & IP65 protection , complete with louvers & shutters single phase complete incl making Hole for fixing of fan. complete as specified and directed. 21 Supply & Fix single phaseflame proof weather proof ceiling fan in cast aluminum LM6 of size of 481440 RPM single phase 230 volts 50 Hz suitable for hazardous locations of zone 1&2cExd with relevant IS & IP65 protection, complete complete as specified and directed. 22 Supply & Fix Flameproof watherproof ceiling fan regulator forflame proof whether proof ceiling fan of size 48 suitable for hazardeous locations of zone 1 and 2 complete as specified and directed. 23 Supply and fix flameproof weatherproof wall industrial socket with 4 pole MCB 25 A, 415 volt3P+1N + Earth and plug top combined,Three Phase Earth confirming to IP 44 complete as specified and directed. 24 Supply & Fix weather proof flame proof with IP55 sheet metal enclosure for DB TPN 4 Way certifiedby CMRI Dhanbad of cast aluminum alloy LM-6 construction with cable entries at bottom consisting of DB with MCCB FP 16KA - 1 No as an incomer and MCB SP C Series 6A, 10KA - 8 Nos and TP 32A - 01 Nos as outgoing including flameproof cable gland & lugs at bottom side etc complete as specified and directed. 25 Material & Labour for Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, returning refilling in and removing of surplus soil to a distance upto 50mtr,PCC (1:3:6) type C-1 chamber (using 20mm grade stone agreegates) with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both ways MS handle 12mm dia, 15 mm dia light grade GI protection pipe, GI funnel with wire mesh, GI watering pipe of size 20 mm dia med. grade and lugs, main Earthing lead up to 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 5 of SSR Pt-I 1991 specification complete all as specified and directed. Note :-(i) The excess requirement (if more than 7.5 Mtr) of GI strip and their joints for connecting up to the test point will be measured and paid separately) (ii) The excavation exceeds if any will be deemed to be included in the item rate. 26 (B) COOLING APPLIANCE 27 Supply, Install and testing flameproof air cooled split unit room air conditioner with inverter compressor electric driven single phase of capacity 1.5TR, 5 Star BEE rated complete including provision of MS angle iron stand/bracket water outlet pipe to appropriate point and other necessary accessories etc and making good the disturbed surface all as directed and as per manufacturers instructions complete all as specified and directed. 28 Material & Labour for single phase 25amps 240V 50Hz two pole switch socket and plug combined in LM6 flame proof fitting and connecting with the wiring complete all as specified and directed. 29 Material & Labour for flame proof concealed point wiring using approved colour coding as per IS with 4 Sqmm two nos single core PVC insulated but unsheathed FRLS CABLE, 1100V grade, IS-694 marked with multistranded copper conductor and earth continuity wire with similar 4 Sqmm cable ( including connecting to earth dolly) drawn through ISI marked (IS 9537 Part II) of latest edition ERW stove enamelled, steel conduit concealed in wall , not less than 25mm dia with and including flame proof bends and elbows , couplers, bell mouth reducer, junction box all as per relevant LS and type tested approved by CMRI Dhanbad fixed with solid backed distance saddles & nestie fold GI screws all as specified for One 3 Pin socket outlet controlled by two pole switch socket and plug combined in LM6 flame proof fitting complete all as specified and directed. 30 (C) EXTERNAL ELECTRIC SUPPLY 31 Supply, Installed and testing of LT panel board out door type, weather and vermin proof, factory fabricated, cubical type made out of CRCA sheet 3.15mm thick with mounting on frame of angle iron 50X50X5MM fixed on ground but not less than height 30cm from ground level suitable for 415V, 3 Phase, 4 wire system with from openable each compartment and front double door with sliding bolt for locking arrangement with PVC star screwing hinged arrangement, epoxy power coated , internal wiring complete with copper conductor cable for metering system and CTs complete all as specified, comprising by providing of the following equipments/fittments complet:- (a) Aluminium bus bar suitable for three phase four wire system of current rating 400 amps covered with coloured PVC sleeves as per colour code mounted on DMC insulators 01 Set. 32 (b) MCCB 4 pole 415Volts of currentrating 250Amps, thermal release rupturing capacity 25 KA-01No. (b1) MCCB 4 Pole of current rating 63A, thermal release and rupturing capacity 16 KA - 03 Nos (c)MCCB, 4 pole of current rating 32 Amps thermal release and rupturing capacity 16 KA -04 Nos. (d) Digital Multi function meter 96mm square mounted type 0-500 volts-01No. (f) Indicating Neon (RYB) Lamp set of three - 01Set (g) Internal wiring complete with copper cables of suitable size and lugs including gland packing complete (h) PCC 1:2:4 type B-1 as in foundation incl earth work, form work rendering etc complete all as specified. (k) Analog time switch 03 module with contactor-01 set 33 Supply & Fix double wall corrugated high density polymer ethyl (HDPE) pipe for layingof electric cableof 63mm outer dia and 51mm inner dia with IS 14930 (Part 2) 2001 laid in trenches, wall floor pole including bends sockets and other connected accessories complete all as specified and directed. 34 Material & Labour for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick and burried directly Jr, ground (earth pit not less than2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth plate with GI strip of size 32x6mm by means of bolts, nuts check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and indicates including testing on completion including PCC pit (1:3:6) type C-1 using 20mm graded stone aggregate in cement concrete & 40mm thick precast RCC cover in (1:2:4) type B-1 20mm graded stone aggregate reinforced with 8mm dia MS round bar @ 75 c/c both ways with 02 Nos lifting handles of 12mm dia MS plain bar , GI pipe 50mm dia light grade GI pipe for earth lead protection etc complete all as specified and directed. Note: GI strip beyond 7.5 metres shall be measured and paid seperately. 35 (D) FIRE POINTS 36 Material & Labour for construction of fire point with permanant specification made out by CGI sheet on angle iron trusses support on angle iron post with brick plinth etc.,excavation and earthwork, painting to steel work, white whash to plinth etc complete all as specified and shown in drawings. 37 (E) ARMOUR PLATE 38 Supply & Fix 100mm thick spade heat treated plates in CQA(M)-51 specifications with hardness 321-377 BHN including drilling holes, welding etc as required for fixing all as specified and directed and as shown in drawing complete all as specified and directed. 39 Total amount of SCHEDULE A PART X (MISC B/R & E/M ITEMS)

Key Value

Document Fees
INR 3000 /-
EMD
INR 606000.0 /-
Tender Value
INR 5.61 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail