}

Tender For Comprehensive Maintenance Of Ups System And Servo Voltage Stabilizer At Various Locations Under Ge (Af) Marathahalli., marathahalli-Karnataka

Military Engineer Services has published Tender For Comprehensive Maintenance Of Ups System And Servo Voltage Stabilizer At Various Locations Under Ge (Af) Marathahalli.. Submission Date for this Tender is 13-08-2025. Dry Cell Batteries Tenders in marathahalli Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

50339850
Tender For Comprehensive Maintenance Of Ups System And Servo Voltage Stabilizer At Various Locations Under Ge (Af) Marathahalli.
Tender
Indian
Karnataka
Marathahalli
13-08-2025

Tender Documents

Tender Details

Tender For Comprehensive Maintenance Of Ups System And Servo Voltage Stabilizer At Various Locations Under Ge (Af) Marathahalli.; 1 Comprehensive maintenance of UPS3 KVA (03 Nos) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carriedin a three months all as directed by Engr-in-Charge.Note :-(i) Thereport shall be submit tothe Engr-in-Charge (ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint (iii) The Battery will be measured and paid seperately.(iv) The rate inclusive of all defects parts.Note :- 03 Nos UPS of 3 KVA will be measured as one job. 2 Comprehensive maintenance of UPS 4 to5 KVA (01 No) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carriedin a three months all as directed by Engr-in-Charge. Note :-(i) The service report shall be submit tothe Engr-in-Charge (ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint (iii) The Battery will be measured and paid seperately.(iv) The rate inclusive of all defects parts. 3 Comprehensive maintenance of UPS 6 to 8 KVA (01 No) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carriedin a three months all as directed by Engr-in-Charge. Note :-(i) The service report shall be submit tothe Engr-in-Charge (ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint (iii) The Battery will be measured and paid seperately.(iv) The rate inclusive of all defects parts. 4 Comprehensive maintenance of UPS10 KVA (04 Nos) any make at various location with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carriedin a three months all as directed by Engr-in-Charge. Note :-(i) The service report shall be submit tothe Engr-in-Charge (ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint(iii) The Battery will be measured and paid seperately.(iv) The rate inclusive of all defects parts.Note :- (i) 04 Nos UPS of 10 KVA will be measured as one job. 5 Comprehensive maintenance of UPS 15 KVA (01 No) any make at various location with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carriedin a three months all as directed by Engr-in-Charge. Note :-(i) The service report shall be submit tothe Engr-in-Charge (ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint .(iii) The Battery will be measured and paid seperately.(iv) The rate inclusive of all defects parts. 6 Comprehensive maintenance of UPS20 KVA (02 Nos) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carriedin a three months all as directed by Engr-in-Charge. Note :-(i) The service report shall be submit tothe Engr-in-Charge .(ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint(iii) The Battery will be measured and paid seperately.(iv) The rate inclusive of all defects parts.Note :- (i) 02 Nos UPS of 20 KVA will be measured as one job. 7 Comprehensive maintenance of UPS30 KVA (02 No) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carriedin a three months all as directed by Engr-in-Charge. Note :-(i) Theservice report shall be submit tothe Engr-in-Charge (ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint (iii) The Battery will be measured and paid seperately.(iv) The rate inclusive of all defects parts.Note :- (i) 02 Nos of UPS of 30 KVA will be measured as one job. 8 Comprehensive maintenance of UPS60 KVA (01 No) any make at various locationswith complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carriedin a three months all as directed by Engr-in-Charge. Note :-(i) The quarterly service report shall be submit tothe Engr-in-Charge (ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint (iii) The Battery will be measured and paid seperately.(iv) The rate inclusive of all defects parts. 9 Comprehensive maintenance of UPS80 KVA (01 No) any make at various locationswith complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carriedin a three months all as directed by Engr-in-Charge. Note :-(i) The service report shall be submit tothe Engr-in-Charge (ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint.(iii) The Battery will be measured and paid seperately.(iv) The rate inclusive of all defects parts. 10 Repair andmaintenance of servo voltage stabilizer oil cooled/Air cooled 1 KVA to 15 KVAany make at various locations with complete calibration of systems, including all parameter as per manufacturer design servicing rectification of defects replacement of required parts etc the parts measured in relevant scheduleall as directed by Engr-in-Charge. Note : (i) Theservice report shall be submit to Engr-in-Charge (ii) Parts to be measured and paid seperately. 11 Repair andmaintenance of servo voltage stabilizer oil cooled/air cooled 16 KVA to 50 KVAany make at various locations with complete calibration of systems, including all parameter as per manufacturer design servicing rectification of defects replacement of required parts etc the parts measured in relevant scheduleall as directed by Engr-in-Charge. Note : (i) Theservice report shall be submit to Engr-in-Charge duly signed.(ii) Parts to be measured and paid seperately. 12 Repair andmaintenance of servo voltage stabilizer oil cooled/air cooled 55 KVA to 100 KVA (03 Nos) any make at various locations with complete calibration of systems, including all parameter as per manufacturer design servicing rectification of defects replacement of required parts etc the parts measured in relevant scheduleall as directed by Engr-in-Charge. Note : (i) Theservice report shall be submit to Engr-in-Charge (ii) Parts to be measured and paid seperately. 13 Repair andmaintenance of servo voltage stabilizer oil cooled/air cooled 100 KVA to 500 KVA any make at various locationswith complete calibration of systems, including all parameter as per manufacturer design servicing rectification of defects replacement of required parts etc the parts measured in relevant schedule are i all as directed by Engr-in-Charge. Note : (i) The service report shall be submit to Engr-in-Charge (ii) Parts to be measured and paid seperately. 14 Auto transformer of any capacity required for Sl Item Nos 1 to 13:- 15 Supply only Auto Transformer 2 /4/6/8/10 Amps 16 Supply onlyAuto Transformer 12/15/18/20 Amps 17 Supply onlyAuto Transformer 23/28 Amps 18 Supply onlyAuto Transformer 32/35 Amps 19 Buck Boost of any capacity required for Sl Item Nos 1 to 13:- 20 Supply onlyBuck Boost Tx 2/4/6/8/10 Amps 21 Supply only Buck Boost Tx 12/15/18/20 Amps 22 Supply only Buck Boost Tx 23/28 Amps 23 Supply onlyBuck Boost Tx 35/45 Amps 24 Supply onlyBuck Boost Tx 60/100 Amps 25 Control transformer of any capacity required for Sl Item Nos 1 to 13:- 26 Supply onlyControl transformer PS Sensing Tx 27 Supply onlyControl transformer Ph Re Sensing 3 Ph Tx 28 Supply onlyControl Transformer DPS Sensing Tx (each) 29 Supply only Control Transformer DC Motor sensing Tx 30 Meters of any capacity required for Sl Item Nos 1 to 13:- 31 Supply only 0-300 v local 72 Sqmm 32 Supply only 0-500 v local 96 sqmm 33 Supply only 0-300 Voltmeter AE 72 Sqmm 34 Supply only 0-500 Voltmeter AE 96 Sqmm 35 Supply only DPM Volt & Amp Meter 36 Supply only CT Coils 37 Carbon Brushes of any capacity required for Sl Item Nos 1 to 13:- 38 Supply only Carbon Brush upto 30k/75k 39 Supply only Carbon Brush upto 200k 40 PCBs of any capacity required for Sl Item Nos 1 to 13:- 41 Supply only 2K2R & 2K5R PCB 42 Supply only SCVS2 PCB 43 Supply only DGDPS Control PCB 44 Supply only Phase reversal PCB 45 Supply only E Over load PCB 46 Supply only D C Motor contrl PCB 47 Supply only 3 Phase cutoff PCB 48 Supply only 3mm LED strip 5 lights 49 Supply only 2K2/2K5 Control PCB 50 Supply only 5/ 10 mm LED strip 51 Supply only DPS LED PCBS 52 Supply only 2K6R New control PCB 53 Supply only LED Strips 54 Motors (DC & AC) of any capacity required for Sl Item Nos 1 to 13:- 55 Supply only12V DC Motor Big 56 Supply only 3Kg Stepper Motor 57 Supply only10 Kg Stepper Motor 58 Supply only 3Kg/10 kg RC Network 59 Control switches of any capacity required for Sl Item Nos 1 to 13:- 60 Supply only SPST Switch (I&D) 61 Supply only DPDT Switch (A.M) 62 Supply only Spring loaded switch 63 Supply only Salzer switch (A&V) 64 Supply only Pot meter 1K Ohms 65 Supply only Surg/Spike Sentry Box 66 Coupling gears of any capacity required for Sl Item Nos 1 to 13:- 67 Supply only Main gear upto 30/75/80 kva 68 Supply only Pinon Gears (8 & 10mm) 69 Electricity Components of any capacity required for Sl Item Nos 1 to 13:- 70 Supply only BT-136 TRAIC 71 Supply only IC 741 & 555 BEL 72 Connectors of any capacity required for Sl Item Nos 1 to 13:- 73 Supply only 8 way Blank type 74 Supply only 22 pin Edge connectors 75 Supply only PCB connector 76 Supply only 4 way connector 77 Taking out the sample of isolation transformer oil from bottom of each itemsinstalled at various locations for checking die elecric strength & acidity test of oil and carrying out dehydration (Filtration) of cooling/ insulating oil of LT switch gears through straight line oil filtration plant for removing carbon deposit, extracting moisture content etc.After filtration, the oil shall withstand 40 KV for one minute die electric strength.Die elecric strength & acidity to be tested before and after filtration and submit the test results all as specified and directed by Engr-in-Charge. 78 Supply only insulating /cooling oil suitable for isolation transformers / switch gear etc having die electric strength of more than 40 KV for filling / topping up complete all as specified and as directed by Engr-in-Charge. 79 Taking down electrical chimney filter for cleaning and reassembling complete including testing and commissioning to the entire satisfaction of complete all as specified and as directed by Engr-in-Charge. 80 Supply only for battery 42 AH alongwith necessary suitable fitting complete all as specified and directed by Engr-in-Charge. 81 Supply only for battery 26 AH alongwith necessary suitable fitting complete all as specified and directed by Engr-in-Charge. 82 Supply only for battery 75 AH alongwith necessary suitable fitting complete all as specified and directed by Engr-in-Charge. 83 Supply only for battery 65 AH alongwith necessary suitable fitting all as directed by Engr-in-Charge. 84 Repair and maint of isolation transformer upto 250 KVA drain out old oil and after filtration the oilandchecking the winding of transformer and refilling the same after rectified the problem and change the parts all as specified and directed by Engr-in-Charge. 85 Supply socket wrench set i.e Bit sockets :SL 4,5,6 Ph 1,2,3,Pz1,2,3,Hex 3,4,5,6,7,8,T10,15,20,25,30,40 ,1/4 DR Sockets:4,4.5,5,5.5,6,7,8,9,10,11,12,13,14mm ,Hex key wrenches 1.5,2,2.5 mm,1/4DR universal joint ,1/4 X2 extension bar ,1/4 X6 flexible extension ,1/4 DRsliding bar 1/4 quick ratchet handle ,6 spinner handle ,Bit adaptor ,blow case along with box complete all as directed by EIC 86 Supply only tool box with 1 hand saw,bit set SL 1/8,SL3/16,SL 1/4,PH1,PH2,T15,T20,H1/8,H5/32,Adaptor ,9 W LED flashlight ,precision screwddrivers PH1,PHO slotted 1.6 mm,2.o mm ,5m insulation tape ,measuring taoe,adjustable wrench,hammer,nose pler,combination plier,bit driver,tester knife ,1/4 Dr socket etc complete all as directed by EIC 87 Supply only BD40 cordless smart screwdriver ,microusb charger with cable ,manual orecision bit holder,screwdriver bits along with multimeter complete all as directed by EIC 88 Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sq.mm, 3½ core including taking down existing cablecomplete all as specified. 89 Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 Sq.mm, 3½ core including taking down existing cablecomplete all as specified. 90 Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium 3½core including taking down existing cablecomplete all as specified. NOTE FOR Sl Item Nos 36 to 38 :- Excavation & Earthwork, Cable protection, Sand cushioning shall be measured & paid seperately 91 Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, not exceeding 10 sq m on plan and getting out in any type of soil (i.e. soft/loose soil or hard/dense soil) complete all as specified. 92 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils. 93 Removal of surplus soil to a distance not exceeding 50 m and deposited where directed at a level notexceeding 1.5 mabove the starting point complete all as specified. 94 S&F 50 mm bore GI tubing light grade including necessary fittings such as bend, tee, elbow etc complete in trenches/ on wall complete all as specified. 95 Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250 x 150 x 40 mm for cable protection 96 Supply and spreading fine river sand in trenches for cushioning of under ground cable all as directed by Engr-in-Charge at site Note:- Only punned thickness 18 cm will be measured and paid . 97 Disconnection unsv Supply and fixing & Testing UPS 1000 VAcomplete all as specified and as directed by EIC 98 Disconnection & Supply ,fixing, testingBattery12 Volts.180 AH 99 Disconnection ,Supply,testing.commissioning of JIELONG roller shutter motor of model no ECR168-1P-(300),single phase 220 V AC,50 Hz,,Power 250 W,weighting load 300 Kg ,IP44,complete all as specified and as directed. 100 M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level, Alternate layers of charcoal)& common salt Crystal, in and including back filling compund in layers and filling up with black cotton soil upto the top edge/ ground level andconnected to copper earth strip 20 x 3 mmby means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly, equipment all as shown in electrical plateNo. 5 of SSR Part I of 2009 & testing complete including 40mm dialight grade GI pipe upto 7.5 mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame,including 20 mm bore water pipe medium gradeGI Tubing includingGI Funnel , wire mesh etc. (NOTE :- Copper earth continuity conductor 20x3 and GI light grade protection pipe 40mm dia beyond 7.5 mtr shall be measured and paid under the respective items ). 101 Dismantling,takingdown M&L for Copper strip of size 20 x3.15 mm complete including cut to length and size to match the existing system and fixing the same to the wall / roof on/on polewith fixing materials complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail