| 1 | Demolition of cement concrete of any description and in any position not otherewise specifically provided for as in roof padding etc and removing of debris from outside MD land complete all as specified and as directed. |
| 2 | M&L for 10 mm thick Plaster on RCC roof slab and sunken portion with CM ( 1:3) using water proofing compound @ 3%by totalweight of cementused as per manufacturer\"s instructions shall be carried out complete all as specified and as directed.(Note : WPC shall be measured and paid separately under relavant item) |
| 3 | M&L for PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate as in roof padding / sunken floors and similar work using WPC @ 3%by total wt of cement used as per manufacturer\"s instructions complete all as specified and as directed. (Note : WPC shall be measured and paid separately under relavant item)) |
| 4 | M&L for preparing plastered surfaces and applying primer @ 0.30/Kg per sqm and applying tack coat of bitumen 85/25 @ 1.2 kg/Sqm laying 3.0mm thick polyster reinforced APP modified water proofing membrane weighing not less than 3.5kg/sqm 100 mm overlaps both longitudinally and transverselyby torchbonding overcoat of hot blown andone coat of bitumen basedpaint @1.20 ltr/sqm over APP membrane including removal of existing water proofing treamant on roof with plaster, sunken slabs, edges and vertical surfaces complete all as specified and as directed. |
| 5 | M&L for applying a coat of reflective bitumenous aluminium paint @ 0.15 Kg / sqm over Bitumen surface complete all as specified and as directed. |
| 6 | Supply only water proofing compound complete all as specified and as directed. |
| 7 | S&F rotational moulded Polyethylene [HDPE] water tanks, Triple layered, ISI Marked Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes including taking down old tanks complete all as specified and as directed. |
| 8 | S&F rotational moulded Polyethylene [HDPE] water tanks, Triple layered, ISI Marked Cylindrical & Vertical Type 500 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes including taking down old tanks complete all as specified and as directed. |
| 9 | S&F in repairs Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and completeall as specified and as directed. |
| 10 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan- necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) completeall as specified and as directed. |
| 11 | S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 110mm complete all as specified and as directed. |
| 12 | S&F PVC (SWR) bends 110mm complete all as specified and as directed completeall as specified and as directed. |
| 13 | Dismantling of Asbestos cement (corrugated, semicorrugated and Transulent sheet etc) sheets in roof covering incl ridges complete all as specified and directed. |
| 14 | Dismantling of Mangalore pattern roofing tiles with or without ceiling tiles or slate roofing in roof covering incl ridges complete all as specified and directed. |
| 15 | Dissmantling timberscantling 40 sq cm and over in any position complete all as specified and directed. |
| 16 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 17 | M&L fpr Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of anycolour having tensile strength of 550 Mpa as in roof covering/ cladding towall, fixed with self tapping screws complete all as specified and directed. |
| 18 | S&FPre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as on roof covering/ridgesfixed with self tapping screws complete all as specified and directed. |
| 19 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates Grade Fe 410 -W (Gde E- 250) quality A completeall as specified and as directed. |
| 20 | M&L for preparation of new steel surfaces over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer completeall as specified and as directed. |
| 21 | M & L for preparing old painted steel and iron surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of aluminium paint all as specified and directed. |
| 22 | Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets completeall as specified and as directed. |
| 23 | S&F for anodoised aluminium powder coated snap grid frame work for ceiling 605mm x 605mm using aluminium anodoised sections specified in SSR part-I 1991 including cutting, drilling jointing ect complrtr including 4mm dia of GI hangers wire suspenders fixed with adjustable connectors and providing 6mm thick E-boards (Classic) 605mm x 605mm sizecompleteall as specified and as directed. |
| 24 | M & Lfor seamless false ceiling made out of 12mm thick of gypsum board fixed to the ceiling section with 25mm long self drillingand tapping screws having Philips head with under head cutter at 200mm centre to centre, including finishing the joints of face board with specially formulated joining compound and 48 mm wide fibre tape to provide seam less finish and including GI channel 0.55 mm thick with two unequal flanges of 20 to 30mm and web of 27 mm fixed to surrounding wall using nylon sleeve and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 215 mm each and web of 45 mm suspended from soffits at approx. 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.20mtr length) of 0.55 mm thick having kurled web of 50 mm and flanges of 26 mm each with lips of 10.5 mm fixed to theintermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including 6mm thick GI hangers adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40x3 mm size long and expansion hold fasteners 12.5mm dia 40mm long includingthin layer of Pop with Gypsum binder,sanding the surfaces till smooth surface is obtained and finally applying two coats of acrylic emulsion over one coat primer over 3mm thick putty completeall as specified and as directed. |
| 25 | S&F in repairs of CPVC pipes 20 mm dia SDR 11 & plian CPVC SDR 11 fittings in wall /ceiling or laying in floors taking down old GI tubes complete all as specified and directed. |
| 26 | S&F in repairs of CPVC pipes 25 mm dia SDR 11 & plian CPVC SDR 11 fittings in wall /ceiling or laying in floors taking down old GI tubes complete all as specified and directed. |
| 27 | M&L for plain cement concrete type B1, (20 mm graded crushed stone aggregate) as in coping, and gap filling of between wall and roof, tank stagging and similar works etc complete all as specified and directed. |
| 28 | Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning with detergent/detergent powder etc. reconnecting and re-fixing in position including cleaning and removing all scale dirt etc. from tanks and from mouth of circulating pipes etc. and writing the date of cleaning of tank and due date for cleaning of tank , capacity of tanks exc. 500 liters and not exc. 1000 liters complete all as specified and as directed(Note: Each tank will be shifted as twice) |
| 29 | Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning with detergent/detergent powder etc. reconnecting and re-fixing in position including cleaning and removing all scale dirt etc. from tanks and from mouth of circulating pipes etc. and writing the date of cleaning of tank and due date for cleaning of tank , capacity of tanks exc.250 liters and not exc. 500 liters complete all as specified and as directed(Note: Each tank will be shifted as twice) |
| 30 | Cleaning of RCC/PVC water tanks with bleaching powder removing all scale and dirt etc from tank and from tanks and from mouths of circulating pipes, etc including writing with paint out side tanks \"tanks cleaned on with month and year capacity of tanks exc 250 & n. exc 500 ltrs and recconecting air lock complete all as specified and as directed. |
| 31 | S&F in repairs 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed completeall as specified and as directed. |
| 32 | S&F in repairs 25mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed completeall as specified and as directed. |
| 33 | S&F in repairsfor providing20mm dia CPVC gate valvesscrewed both ends for iron pipes completeall as specified and as directed. |
| 34 | S&F in repairsfor providing25mm dia CPVC gate valvesscrewed both ends for iron pipes completeall as specified and as directed. |
| 35 | Taking down cement plaster from walls built in cement mortar, etc. including raking out joints, hacking for key, scrubbing down with water, etc. to receive plaster completeall as specified and as directed. |
| 36 | M&L for rendering 15 mm thick onfair face surfaces of brick work or concrete in CM (1:4) finished even and smooth without using extra cement completeall as specified and as directed . |
| 37 | M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM (1:6) even and smooth without using extra cement completeall as specified and as directed. |
| 38 | M & L for preparing new plastered or unplastered surfaces on walls including cornices and applying two coat of cement base paint complete all as specified and as directed . |
| 39 | M & L for preparing new plastered or unplastered surfaces on walls including cornices and applying two coats of Oil bound distemper over a coat of cement primer completeall as specified and as directed. |