Replacement Of Sewage Of Pump-Sets And Other Allied E And M Works At Sarai Kale Khan Sps In Jangpura Constituency Ac-41. , Supply Of Horizontal, Non Clog Sewage, Solid Handing Pump Having Discharge 378 M3/Hr. Head 15 Mtr. 1475 Rpm With Ci Impeller, 410 Shaft & Ss Sleeve, Ci Body, Coupled With 40 Hp, 3 Phase Ac, 1475 Rpm, Tefc Squirrel Cage Induction Motor, Mounted On A Common Fabricated Ms Base Frame With Ci Tyre Type Coupling And Ms Coupling Guard. Make Of Pump:-Kirloskar/M&P/Jyoti/Any Djb Approved Make Make Of Motor:-Cg/Kirloskar/Abb/ Any Djb Approved Make , Supply Of Ms Pipe Of Size 250 Mm Dia Make- Tata/Jindal , Supply Of Ms Pipe Of Size 150 Mm Dia Make- Tata/Jindal , Supply Of Ms Bend Of Size 150 Mm Dia. , Supply Of Ms Flange Of Size 150 Mm Dia. (12Mm Thickness) , Supply Of Ms Flange Of Size 250 Mm Dia. (12Mm Thickness) , Supply Of Cidf 150 Mm Sluice Valve, Non Rising Spindle. Pn 1.0.Make:- Kirloskar/Ivc , Supply Of Cidf Swing Type Non Return Valve Pn 1.0, Size150 Mmmake:- Kirloskar/Ivc , Supply Of Nut Bolt With Washer , Supply Of High Pressure Rubber Packing , Making To Suitablesize M.S Clamp As Per Requirement Duly Fabricated Out Of 12.5 Mm Thickness X 100Mm Wide With Nut Bolts For Supporting Of Horizontal Suction Pipeand Other Supporting Required. , New Generation Energy Saving And Environmental Friendly Long Life 70/72 W Led Street Light Made Up Of Pressure Die Cast Aluminum Housing With High Efficient Led As Lighting Source And Pc Cover Having Top Opening Separate Driver Compartment With Ip66 Protection And Impact Resistance Of Ik07. , Supply/ Fixing Of 32 Mm Dia X 2 Meter Long G.I. Pipe (Medium Class ) Bracket For Mounting Of Fluorescent / Hpmv / Hosv Street Light Fitting On Pole Including Bending The Pipe To The Required Shape , 2 Nos. 40 Mm X 3 Mm Flat Iron Clamp With Nuts, Bolt And Washer, Painting The Flat Iron With Primer And Finish Paint Etc. As Required. , Supply And Fixing 1200 Mm Size Ceiling Fan. Make : Havells/Orient/Crompton / Any Djb Approved Make. , Supply And Fixing 450 Mm Size Exhaust Fan. Make : Havells/Orient/Crompton / Any Djb Approved Make. , Supply And Fixing 600 Mm Size Air Circulator Fan. Make : Havells/Orient/Crompton / Any Djb Approved Make. , Wiring For Light Point / Fan Point/ Exhaust Fan / Call Bell Point / With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Type Switch,Suitable Size Ms Box And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Dsr 20221.10.3 , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connection But Excluding Modular Plate Etc. As Required. 5/6 A Switch Dsr 2022 1.24.1 , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connection But Excluding Modular Plate Etc. As Required. 15/16 A Switch Dsr 2022 1.24.3 , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connection But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 A Socket Outlet Dsr 2022 1.24.4 , Wiring For Circuit/ Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire. Dsr 20221.14.3 , Removing Of Electric Connection, Dismantling Of Pumps, Motor, Valve, Tyre Coupling, Suction And Delivery Pipes Etc By Cutting Of Nut Bolt And Lifting The Same At Suitable Place And Re-Installation, Erecting, Testing, And Commissioning Of The Above Said Equipments/ Accessories With Necessary Required Items For Completion Of Work I.E. Flange, Msbend, Nrv, Sluice Valve , Pipe, Base Frame, Tyre Coupling Etc, Loading, Unloading, Cartage, Lifting The Same And Taking Out At Floor Level, Making Good All Damages Caused During Installation And Restoring The Same To Their Original Finish As Required, Adequate Safety Provision, Barricading, Warning Signal And Other Safety Measures While Executing The Work Or Wherever Necessary So As To Avoid Accident. The Components Of The Installation Shall Be Of Such Design So As To Satisfactory Function Under All Conditions. , Lt Distribution Panel Sheet Steel Enclosure Made Out Of 2Mm Crca Sheet Totally Enclosed, Powder Coated Free Standing, Floor Mounted Type, Dust& Vermin Proof, Outward Opening, Lockable Doors Having Hidden Hinges And A Bolted Back Cover Both Using Non-Deteriorating Neoprene Rubber Gaskets To Provide Ip-54 Protection .The Each Part Of The Fabricated Panel Will Be Strictly Subjected To Seven Tank Treatment. The Various Components, Assemblies And Sub Equipments Of The Panel Will Be As Per Standard Given In Relevant Is. The Bus Bar Of The Panel Will Be Shaped Out Of High Conductivity, Electrolytic Conductor And Shall Be Liberal Sized In Aluminium. The Control Wiring Of The Panel Will Be Done With Pvc Flexible Copper Wires Of 1.5Mm Cross Section. Each Wire Will Be Terminating With A Ferule Crimped To The Wire, Size 1800Mm X1600x400mm. With All Allied Equipments I.Emccb 415V, Tp 3Phase High Breaking Capacity 50Ka 50Hz,250Ampwith Spreader& Handle-1 No., Mccb 415V, Tp 3Phase High Breaking Capacity 50Ka 50Hz,160Amp With Spreader-3 Nos., Mcb Single Pole 6Amp.- 9 Nos., Mcb Triple Pole 32Amp-1 No., Mcb Triple Pole 63Amp-1 No., Pvc Insulated Copper Flexible Cable Single Core 50 Sq.Mm-80 Mtr. , Over Load Relay 20-33-3 Nos., Over Load Relay 6-10 Amp Range-1 No., Amp. Meter Digital-5 Nos., Volt Meter Digital -1 No., Motor Protection Relay (32-88Amp.). 3 Nos., Power Contactor 220V 3Phase140amp. 9Nos., Power Contactor 220V 3Phase32amp.-1 No., Star Delta Timer On Delay (3-30Sec.)-3 Nos., Indicating Lights Led Type Ryb& On/Off.-18 Nos., Start Push Button Green-3 Nos., Stop Push Button Red-3 Nos., Current Transformer 200/5 (3 Nos.), 100/5 (6 Nos.), 30/5 (3 Nos.)-1 Set., On Load Change Over Switch 200Amp. Open Execution Type-1 No., Fitting Of The Above Components In Panel Enclosure With Terminal Blocks, Channels, Ferrules, Thimble, Support Insulator On Bus Bar, Required Hard Wares, Control Wiring In 1.5Sq Mm Wire Complete In All Respect. Jobincluding Make Provision Of Star Delta Starter (2 Nos.) And Dol Starter (1 No).-1 Job Note:- All Switch Gear Will Be Djb Approved Make , Dismantling Of Old Panel, Structure, Damaged Components And Installation Of The Panel At Site By Making Foundation ,Termination Of Cable Both Incoming & Out Going Side ,Mongeringof Complete Panel , Including Cable Connection,. This Includes Cartage, Loading& Unloading Etc.-1 Job And Testing& Commissioning Of Thepanelwith Relevant Is As Follow: - Check Equipments Specification - Continuity And Earthing -Mccb Mechanism And Alignment -Meggaring Of All Equipments For Phase To Phase, Neutral To Body, Neutral To Earth And Phase To Earth. - All Functional Tests -Checking Forall Tightness Of Nuts And Bolts -Alignments Of Doors Etc. -Interlocking Tests-1 Job.