Tender For Repair/Maint Of Sewage Treatment Plants And Allied Works Under Ge Satwari, satwari-Jammu And Kashmir

Military Engineer Services has published Tender For Repair/Maint Of Sewage Treatment Plants And Allied Works Under Ge Satwari. Submission Date for this Tender is 14-08-2025. Sewage Treatment Plant Tenders in satwari Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

50316350
Tender For Repair/Maint Of Sewage Treatment Plants And Allied Works Under Ge Satwari
Tender
Indian
Jammu And Kashmir
Satwari
14-08-2025

Tender Documents

Tender Details

Tender For Repair/Maint Of Sewage Treatment Plants And Allied Works Under Ge Satwari; 1 M&L for cleaning of sludge receiving chamber, screen channel, MBBR unit, Tube settler unit and chlorine mixing contact tank (Civ unit) of the plant at Peeru Vihar STP of capacity 1.0 MLD complete all as specified and directed. Note : Tube settler is required to be removed before cleaning of STP and stack properly. After cleaning is completed, tube settler is to be re-fixed in its original position.The quoted rate shall be deemed to include the same. 2 All as perSer item No 01 here -in-before but of the plantnear BSO yard STP of capacity 1.2 MLD complete all as specified and directed. 3 All as per Ser item No 01 here -in-before but of the plant at Raipur Satwari STP of capacity 0.5 MLD complete all as specified and directed. 4 All as per Ser item No 01 here -in-before but of the plant at 166 MH STP of capacity 0.2 MLD complete all as specified and directed. 5 M&L for Cleaning of sludge dry bed, drain line (Civ unit) and sorounding area of plant i.eexcavated grass /weeds/hard cement concrete / stone, debris, excess soil etc. at Peeru Vihar STP of capacity 1.0 MLD complete all as specified and directed. Note:- (i)The rate shall be deemed to be include the cost of removing the grass, weeds, debris, excess soil etc to a distance not less than 2000m and keeping the excavated surface clean and leveled (ii)If there is any damage to the existing services like HT/LT UG cable, telephone wire, pipe line and sewage line etc,the same shall be repaired by the contractor immediately and quoted rate shall be deemed to include the same . 6 All as per Ser item No 05 here -in-before but of the plant at near BSO yard STP of capacity 1.2 MLD complete all as specified and directed. 7 All as per Ser item No 05 here -in-before but of the plant at Raipur Satwari STP of capacity 0.5 MLD complete all as specified and directed. 8 All as per Ser item No 05 here -in-before but of the plant at 166MH STP of capacity 0.2 MLD complete all as specified and directed. 9 M&L for cleaning of sludge from underground sump (Lift well) ,main sewage/drainage receiving sump of size 3 metre diameter and 6 metre deep at Satwari officer enclave and removing sludgeto a distance not less than 1500 metre to a designated place including scrapping off the walls and cleaning the surfaces including preparation of surfaces& applying two coats of cement base paint over a coat of primer complete all as specified and directed. 10 All as per Ser item No 9 here-in-before but of size 8 metre diameter 06 to 08 metre deep at 166 MH, 15 Guard and near APS School complete all as specified and directed. 11 All as per Ser item No 9 here-in-before but of size 10 metre diameter 6 metre deep at Raipur Satwari complete all as specified and directed. 12 All as per Ser item No 9 here-in-before but open type and of size12 metre diameter 6 metre deep at near Pump House No 02 including taking out broken trees/branches if foundcomplete all as specified directed. 13 All as per Ser item No 9 here-in-before but of size 10-12 metre diameter 6-8 metre deep at Raipur Satwari near STP complete all as specified and directed. 14 M&L for scrubbing of outer wall surfaces with wire brush of Reciving chamber, screening chamber, MBBR chamber, sludge settler and chlorine mixing tank of capacity 0.5 MLD to 1.2 MLD of plant and preparing the surfaces of wall, chajjas, facias, faces of columns, beam including all metal/pipe line surfaces etc and applying two coats of weather proof exterior emulsion paint over a coat of 1mm thick wall care putty complete all as specified anddirected. Note: The quoted rate shall also be deemed to include:-(i)Removal of scrappedmaterial deposited at plinth protection to a distance upto 50 mtr from plant. (ii)All types of safety equipments and tools required at site. 15 All as per Ser item No 14 here-in-before but ofpackage type STP plant at 166 MH complete all as specified and directed. 16 M&L forfillingofPVC bio pac floatingmedia of MBBR unit of the sewage treatment plantof size 22mm x 13mm, thickness 1.5 mm complete all as specified and directed. 17 S&F in replacement of automatic star delta starter, three phase of suitable size of motor 15/20 HP with over current relay control system, single phase preventor , Phase reversal protection, Phase unbalance protection, Auto restart (with variable 30 sec to 5 min on delay) and power on & pump on indication complete all as specified and directed. 18 S&F in replacement of automatic star delta starter, three phase of suitable size of motor 25/30 HP with over current relay control system, single phase preventor , Phase reversal protection, Phase unbalance protection, Auto restart (with variable 30 sec to 5 min on delay) and power on & pump on indication complete all as specified and directed. 19 S&F in replacement of single phase preventor, 230 Volts, 50 cycles etc complete all as specified and directed. 20 M&L for taking out 12.5 HP non clog submersible pump set from sewage sump, disconnecting pipes, pump and transporting to workshop for repair , cutting of burnt winding/cleaning of stator for rewinding with super enameled copper wire of existing size, providing with insulating materials, flame proof/water proof laminated insulated strips, cotton tape, varnishing complete and shifting back to site and lowering & assembling in the existing position, connecting and testing complete all as specified and directed. 21 Allas per Ser item No 20 here in before but of size 10 HP complete all as specified and directed. . 22 Allas per Ser item No 20 here in before but of size 7.5 HP complete all as specified and directed. . 23 Allas per Ser item No 20 here in before but of size 3.5 HP complete all as specified and directed. . 24 M&L for replacement ofthrust bearing of non clog submersible motor of capacity 7.5 HP to12.5 HP complete all as specified and directed 25 M&L for replacement ofgun metal bushes for non clog submersible motor of capacity 7.5 HP to 12.5 HP complete all as specified and directed 26 M&L for replacement ofImpellers for non clog submersible pump of capacity 7.5 HP to12.5 HP complete all as specified and directed 27 M&L for replacement ofBowl bush for non clog submersible pump of capacity 7.5 HP to 12.5 HP complete all as specified and directed 28 M&L for replacement ofNeck ring for non clog submersible pump of capacity 7.5 HP to 12.5 HP complete all as specified and directed 29 M&L for replacement of Seal guide sleeve for non clog submersible motor of capacity 7.5 HP to 12.5 HP complete all as specified and directed 30 M&L for replacement of Seal guide sleeve for non clog submersible motor of capacity 3.5 HP to 7.5 HP complete all as specified and directed 31 M&L for dismantling and de-couplingair blower pump of capacity up to 20 HP from existing foundation with electric motor,repair/overhaulding, replacement/adjustment of the following spares:- (a) Adjustment of safety valve (b) Replacement of spring assy (c)Re-metaling/ turning of pump shaft. (d)Replacement of oil ENKLO 320,oil seal,bearing, filter.(e) Replacement of pressure gauge. (f) Replacement of Air filter/cleaner (g) Any minor spares required and re-assembling the pump,testing including painting complete all as specified and directed Note: The cost of transportation to and from workshop is deemed to be included in the quoted rate. 32 M&L for disconnecting air blower motor of capacityup to 20 HP from air blower pump and transporting to workshop for reapir , cutting of burnt winding/cleaning of stator for rewinding with super enameled copper wire of existing size, providing with insulating materials, flame proof/water proof laminated insulated strips, cotton tape, varnishing complete and shifting back to site , lowering & assembling in the existing position, connecting and testing complete all as specified and directed. 33 S&F in replacement of V Fan belt for blower compressure as per existing makecomplete all as specified and directed . 34 M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in support to CI/GI pipes,header etc including necessary form work complete all as specified and directed. 35 Repair & maintenance of existingsludge duct of size 300mm x 600mm by providing 50-80 mm thick PCC 1:3:6, type C-1(using 20 mm graded crushed stone aggregates) in existing drain wall duly finished with 15 mm thick cement mortar 1:4 complete all as specified and directed. 36 Repair & maintenance of existingsludge duct of size 450mm x 600mm by providing 50-80 mm thick PCC 1:3:6, type C-1(using 20 mm graded crushed stone aggregates) in existing drain wall duly finished with 15 mm thick cement mortar 1:4 complete all as specified and directed. 37 M&L for framed work such as gateway (any size with opening and closing) of dry bed duct, gratings etc with ends of bars shoulderd and/or riveted, or forged into spikes, framed guard bars, barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks,cooler stand,ladder and similar work conforming to Fe290, Gde-E-165 including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces complete all as specified and directed. 38 Carry out water (Raw and treated ) from all STP plants and testing for bacterial, chemical and biological analysis of sewage water treated water from Govt approved lab for following parameters and submission of test reports all as directed: -(a) PH, (b) Chemical Oxygen demand/COD, (c) Biological Oxygen Demant/BOD(d) Total Suspended solids, (e) Oil and Grease(f) TKN, (g) Total Coliform, (h) Organism MPN(k) Dissolved OxygenNote: Water testing shall be carried out twice in the peroid of contract and empty collection bottle will be arranged by the contractor. 39 S&Fsewage non-clog submersible pump set of capacity 7.5 HP , STPC375222 7.5 MODEL, 4 Delivery 25 Meters Head andfixing of nuts, bolts, washer complete all as specified and directed. 40 M&L in repairfor complete earthingwith galvanised mild steel earth plate electrode of size600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr below ground level connected to GI strip 25x4mm by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1, precast RCC cover slab using reinfocement with XPM weighing not less than 4.00 kg/Sqm with suitable handle made of 12mm round bar including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh ,40mm diamedium grade galvanised steel tubing upto 7.5 m length for drawing earth strip protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed. 41 Supply of culture for bacteria production complete. 42 Supply & filling of Alum at various locations of STP plant complete all as specified and directed . 43 Supply and spreading dry river sand in dry bed of sludge tank for sludge settling/ filteration including taking out existing sand and deposting serviceable sand in position complete all as speficifed and directed. 44 Supply and spreading shingle or pea gravel (3 to 6mm size )100mm thick in a layer complete all as speficifed and directed. 45 Supply and laying of PVC / nylone net mat of size 10 micronbetween gravels and river fine sand in the dry bed of STP complete all as speficifed and directed. 46 S&F in replacementsludge Tube settler pad as per existing size at BSO yard STP complete all as specified and directed. 47 M&L for treatement of cracks found in the core concreteas under :-(i) Opening of crack by making a V notch/groove of size 12mm x 12mm over the entire length of the crack as identified by the Engr-in-charge.(ii) Cleaning of all dust/debris/loose material from V notch/groove(iii) Drilling hole of 16mm dia and about 40mm deep along the length of crack @ 300 mm c/c or thickness of structural member whichever is less. Note : In case length of crack is found less than 300 mm then min 2 holes shall be drilled. (iv) Inserting 12 mm dia flexible PVC one way injection nipple in the hole drilled above and fixing the nipple with the help of fast setting epoxy putty. (v) Seal the surface around the nipple and the area of crack between successive nipples polymer modified mortar to ensure that there is no leakage from any gap.(vi) Allow the polymer modified mortar to cure for 24 hours and ensure that is firmly fixed in postion.(vii) Cleaning nipple one by one commencing from the top to bottom in case of column and one by one in alternate direction in case of wall using blow compressed air followed by water injection duly ensuring that there is no obstruction in free flow of grouting materials .(viii) Injecting resin with very low viscosity monomer by mixing resin and hardener in proportions recommended by manufacturer by using injection gun equipped with pressure gauge & valves for controlling of flow of compressed air & resin. Note : Pressure shall be in the range of 1-2 kg/sqm and shall be done in nipples one by one as per order recommended by manufacturer. Mixing of resin and hardener shall be mixed in small quantities so as it is consumed with in 30 minutes. Before use mixer shall be stirred thoroughly.(ix) Allow entire effected surface to cure for 24 hours.(x) Cutting out projected parts of the nipple & seal the hole in the nipple with epoxy putty as recommended by manufacturer.(xi) Cleaning of exposed surface of substrate off any dust /loose material after ageing of the grout as recommended by manufactuer. Note :- Complete treatment to be carried out by authorised applicator of the manufacturer. 48 M&L for providing PMM (Polymer modified cementitious mortar) as under :-(i) Dry substrate surface and make free of debris & dust(ii) Apply Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above, apply 15 mm thick PMM (Polymer modified cementitious mortar)Note :Application of PMM shall be preferably be in coat of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed.Note :- Complete treatment to be carried out by authorised applicator of the manufacturer. 49 M&L for food grade certified elastomeric waterproofing coating of water retaining structure as under :-(i) Cleaning of existing surfaces of RCC members (Wall/slabs) and making surface free of loose material, oil, grease etc. vigorously by wire brushing includinglight grit blasting where necessary as directed by Engr-in-charge.(ii) Further, cleaning the surface using biocide (as recommended by manufacturer) to ensure that surface is free of algae and fungus and no trace of paint (any type) left out. (iii) Cleaned surface to be allowed to dry.(iv) Apply a coat of solvent free epoxy resin coating for potable water retainingstructure at nominal rate of 10sqm/ ltr @ 100 micron thickness after dry or as recommended by manufacturer.(v) Apply a more coat of Solvent free epoxy resin coating for potable water retainingstructure at nominal rate of 10sqm/ ltr (Thickness 100 micron in dry state) after 5-6 hours as recommended by manufacturer complete all as specified and directed. Make Fosroc Nitocote EP 405) or Sikagard 67 Note :- Complete treatment to be carried out by authorised applicator of the manufacturer. 50 S&Fin replacement carbon steel butterfly valve, screwed both ends for iron pipe of 150 mm bore complete all as specified and directed. 51 S&Fin replacement carbon steel butterfly valve, screwed both ends for iron pipe of 100 mm bore complete all as specified and directed. 52 S&Fin replacement carbon steel butterfly valve, screwed both ends for iron pipe of 80 mm bore complete all as specified and directed. 53 S&Fin replacement carbon steel butterfly valve, screwed both ends for iron pipe of 50 mm bore complete all as specified and directed. 54 Supply and laying mild steel pipe, 50 mm bore (heavy duty) both side flange endedalongwith nuts, bolts,washer & rubber sheet,laid in trenches complete all as specified and directed. 55 Supply and laying mild steel pipe, 80 mm bore (heavy duty) both side flange endedalongwith nuts, bolts,washer & rubber sheet,laid in trenches complete all as specified and directed. 56 Supply and laying mild steel pipe, 100 mm bore (heavy duty) both side flange endedalongwith nuts, bolts,washer & rubber sheet,laid in trenches complete all as specified and directed. 57 Supply and laying mild steel pipe, 150 mm bore (heavy duty) both side flange endedalongwith nuts, bolts,washer & rubber sheet,laid in trenches complete all as specified and directed. 58 Supply and laying mild steel pipe, 200 mm bore (heavy duty) both side flange endedalongwith nuts, bolts,washer & rubber sheet,laid in trenches complete all as specified and directed. 59 Supply and fixing DI/MS specials of pipe upto 200 mm dia bore such as bends, tees, collars, tail pieces etc conforming to latest IS complete all as specified and directed. 60 S&F in replacement of MCCB 200 Amps,4 pole,415V,3 phase,50 HZ of breaking capacity 36 KA with adjustable thermal & adjustable magnetic setting complete all as specified and directed . 61 S&F in replacement of MCCB 160 Amps,4 pole,415V,3 phase,50 HZ of breaking capacity 36 KA with adjustable thermal & adjustable magnetic setting complete all as specified and directed . 62 S&F in replacement of MCCB 100 Amps,4 pole,415V,3 phase,50 HZ of breaking capacity 36 KA with adjustable thermal & adjustable magnetic setting complete all as specified and directed . 63 S&F in replacement of MCCB 63 Amps,4 pole,415V,3 phase,50 HZ of breaking capacity 36 KA with adjustable thermal & adjustable magnetic setting complete all as specified and directed . 64 S&F in replacement 1100 volts grade, heavy duty submersible flat cable, PVC insulated & PVC sheathed, 16 sqmm 3 core with stranded copper conductor, suitable for submersible motors & pumpsand making connection complete all as specified and directed 65 S&F in replacement 1100 volts grade, heavy duty submersible flat cable,PVC insulated & PVC sheathed 10 sqmm 3 core with stranded copper conductor, suitable for submersible motors & pumps and making connection complete all as specified and directed 66 S&F in replacement 1100 volts grade, heavy duty submersible flat cable,PVC insulated & PVC sheathed 6 sqmm 3 core with stranded copper conductor, suitable for submersible motors & pumps and making connection complete all as specified and directed

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB