SPECIAL REPAIR FOR CONVERSION OF LT OH LINE INTO UG CABLE, REPLACEMENT OF EXISTING HPSV/MV/MH LIGHT FITTINGS INTO LED LIGHT FITTINGS AND REPLACEMENT OF DAMAGE/BROKEN EXISTING LT PCC/RCC POLES INTO STEEL TUBULAR POLE ALONGWITH CONNECTED WORKS AT BORARUPAK MIL STN UNDER GE 872 EWS.; 1 Dismantling of unserviceable/serviceable ACSR Conductor of any size & type from existing LT over head lines complete all as specified and directed. 2 Dismantling of GI wire from existing LT over head line complete all as specified and directed. 3 Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed. 4 Taking down carefully old unserviceable/serviceable insulator any type from existing LT over head lines complete all as specified and directed. 5 Taking down carefullysecurity light fitting of any make/capacity from existing LT poles complete all as specified and directed. 6 Dismantling of stay assembly along with all accessories from existing LT poles complete all as specified and directed. 7 Dismantling of existing LT PCC/RCC Poles complete all as specified and directed. 8 Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard/dense soil for laying ofUG cable complete all as specified and directed. 9 Excavating in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr deep and not exceeding 3 mtr deep for excavation of poles and getting out in any type of soil complete all as specified and directed. 10 Returning , fillingin including spreading, leveling , wateringand well ramming in layers not exc 25 cm thick with soils complete all as specified and as directed. 11 Removal of surplus soil to a distance not exc 50 mtr away and depositing where directed as a level not exc 1.5 mtr above the starting point all as directed. 12 M&L for sand cushioning using dry and clean sand in two layers, first layers of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed.Note :- Punned thickness only will be measured and paid. 13 Supply and laying well burnt/fire Bricks of size 230 x113 x 75 mm locally available best quality (sub class B bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified. 14 Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9 metres long)including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellowpaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2 (inch) wide complete all as specified and directed.(Note :- Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this sch) 15 Material and labour for PCC 1:4:8 type D2 using 40mm stone aggregate as in foundation, fillingand mass concrete complete all as specified and directed. 16 Material and labour for PCC 1:3:6 type C2 using 40mm stone aggregate as in foundation, filling and mass concrete all as specified and directed. 17 Material and labour for PCC 1:2:4 type B1 using 20mm stone aggregate in coping of pole including necessary form work complete all as specified and directed. 18 Supply and laying XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 95 Sqmm x 3.5 Core complete all as specified and directed. 19 All as per item No 18.00 here- in- before butof size 70 Sqmm x 3.5 Core. 20 All as per item No 18.00 here- in- before butof size 50 Sqmm x 3.5 Core. 21 All as per item No 18.00 here- in- before butof size 35 Sqmm x 3.5 Core. 22 All as per item No-18 here in after butof size 25 Sqmm x 4 Core. 23 All as per item No-18 here in after butof size 16 Sqmm x 4 Core. 24 All as per item No 18.00 here- in- before butof size 16 Sqmm x 2 Core. 25 All as peritem No 18.00 here- in- before butof size 10 Sqmm x 2 Core. 26 Supply and laying of 80mm dia GI tubinglight grade as in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc all as specified anddirected of size 80 mm dia bore. 27 All as per iitem No 26.00 here- in- before but size 50 mm dia bore. 28 Cutting the existing road straight by manual upto 100 mm dia dore, depth and width not less than 1 Mtr below ground level for passing of underground cable and filling back with excavated soil up to 75 %road portion and 25 % shall be made with plain cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. 29 All as per item No 28.00 here- in- before but size 50 mm dia bore. 30 S&F Cable Route indicator duly marked with LT UG cable CI plate elliptical shape with 12mm dia MS rod not less than 700mm in length and embeded in PCC block 1:3:6 (type C1) of size 300x300x300mm in gound including necessary earth work complete all as specified and directed. 31 Supply, jointing, commissioning and testing of cable jointing Kit for 1100 V grade cable for straight through jointwith jointing material and accessories suitable foraluminium conductor cable of sizeupto 50 Sqmm x 3.5 Core complete all as specified and directed. 32 All as peritem No 31.00 here- in- before but of sizefrom 70 Sqmm to 120 Sqmm x 3.5 Core. 33 S&F pole mounted shockproof and rustproof Junction Box rectangular shape, 4 way of size 240X130X110 mm outdoor type and fixing with one MCB SP 10 Amps, C curve, 10 kA including fixing with two nos flat iron clamps of suitable size with necessary mild steel nuts & bolts complete all as specified and as directed. 34 Fixing only of serviceable LED street light fitting of any make/type/capacity complete all as specified and directed. (serviceable LED street light fitting obtained from Item No 5 herein before shall be used.) 35 Supply and fixing LED street light fitting of capacity 60 Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal anagement in multiple optics complete with IP 65/66 protection complete all as specified and directed. 36 All as peritem No 35.00 here- in- before but of sizeof capacity 45 Watt, 230 V AC outdoor type complete all as specified and directed. 37 M&L Street light bracket made out of 150 cm long 32 mm dia light grade GI pipe with required shape with provision of nut and bolts for fixing on top of the pole duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified. 38 S&F (FR) PVC insulated and PVC round unsheathed multistranded copper conductor flexible cable of size 1.5 sqmm x 3 core, complete all as specified and directed. 39 S&F LED flood light of capacity 120 watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. 40 Supply and fix in replcement ofStreet light Digital timer comprising of incoming cable termincal, MCBs, timer, contactor, outgoing termincal duly prewired and accessories housed in MS box outdoor type of capacity 40 Amps TPN, 3 pole, 230 volts contractor rating 32 Amps TP complete all as specified and directed including installation and testing . 41 Supply and installation CPRI approved LT Electric control panel, cubical type, for outdoor use, double door dust & vermin proof floor mounted made out of CRCAsteel sheet of3.15 mm thickand 2.00 mm thick other parts andangle iron legs of size 50mmx50mmx6mm having front and rear hinged doors with front openable shutters for each MCCB/Change Over with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely with fully enclosed bus bar chamber, having electrolytic high conductivity insulated bas bar made but of aluminium strips of rating 600 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete all as including necessary PCC work of height 45 cm from the ground level all as specified and directed.INCOMMING : (i) MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 16 kA - 01 No(ii) Basic Multifunction Meter Cl 0.5 with RS485 - 01 No.(iii) LED Indicator lamp in three colour RYB - 01 Set of 3.OUTGOING:-(i) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 kA - 02 Nos(ii) MCB TPN of capactiy 63 Amps, 415 V, 10KA C curve - 03 Nos(iii) MCB SPN of capactiy 40 Amps, 240 V, 10KA C curve - 04 Nos 42 Supply and installation CPRI approved LT Electric control panel, cubical type, for outdoor use, double door dust & vermin proof floor mounted made out of CRCAsteel sheet of3.15 mm thickand 2.00 mm thick other parts andangle iron legs of size 50mmx50mmx6mm having front and rear hinged doors with front openable shutters for each MCCB/Change Over with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely with fully enclosed bus bar chamber, having electrolytic high conductivity insulated bas bar made but of aluminium strips of rating 600 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete all as including necessary PCC work of height 45 cm from the ground level all as specified and directed.INCOMING:-(i) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 16 kA - 01 No(ii) Basic Multifunction Meter Cl 0.5 with RS485 - 01 No.(iii) LED Indicator lamp in three colour RYB - 01 Set of 3.OUTGOING:-(i) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 kA - 01 No(ii) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 kA - 02 Nos(iii) MCB TPN of capactiy 63 Amps, 415 V, 10KA C curve - 04 Nos 43 Supply and installation CPRI approved LT Electric control panel, cubical type, for outdoor use, double door dust & vermin proof floor mounted made out of CRCAsteel sheet of3.15 mm thickand 2.00 mm thick other parts andangle iron legs of size 50mmx50mmx6mm having front and rear hinged doors with front openable shutters for each MCCB/Change Over with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely with fully enclosed bus bar chamber, having electrolytic high conductivity insulated bas bar made but of aluminium strips of rating 800 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete all as including necessary PCC work of height 45 cm from the ground level all as specified and directed.INCOMING:-(i) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 16 kA - 01 No(ii) Basic Multifunction Meter Cl 0.5 with RS485 - 01 No.(iii) LED Indicator lamp in three colour RYB - 01 Set of 3.OUTGOING:-(i) MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 16 kA - 01 No(ii) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 kA - 02 Nos(iii) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 kA - 03 Nos 44 M & L for Earthing complete with galvanised mild steel earth plate electrode 600X600X6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level, connected to machinery/equipment etc and incl GI strip 32×6 mm dia as earthing lead by means of bolts, nuts, check nuts and washers, protected with and including 50 mm dia light grade GI pipe, 20 mm dia GI pipe (Medium grade) for watering, necessary earth work.PCC 1:3:6 type C1 concrete pit, RCC (1:1.5:3) type A1 pre-cast cover (54X54X5 cm) duly reinforced with and including 8 mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar, embedded in pre-cast cover slab all as specified and shown in electrical plate No-3 of SSR Part-I including testing on completion complete all as specified and directed.