Tender For Provn Of Certain B/R Sanctioned Works At Af Stn Suratgarh; 1 BOQ (PROVN OF CERTAIN B/R SANCTIONED WORKS AT AF STN SURATGARH) 2 S & F cold rolled Mild steel, plain, black sheet of 1.6mm thick in wall cladding and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as directed and specified by Engr-in- charge. 3 M&L for 75mm thick PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in Hard standing/path etc, finished the surface even and smooth without using extra cement, complete all as specified and directed. 4 M&L for 50mm thick PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in Hard standing/path etc, finished the surface even and smooth without using extra cement, complete all as specified and directed. 5 M&L for PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundations or mass concrete complete all as specified and as directed by the Engr-in-Charge 6 M&L Hardcore of gauge n. exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface in broken stones or boulders all as specified and as directed by Engr-in-Charge 7 M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement, complete all as specified and as directed 8 S&F for Plain, galvanised, mild steel sheeting, 1 mm thick as in ridges,hips, valley gutters, eaves gutter drip, downspouts and straight flashings (length and girth as fixed) of with grade of zinc coating 275 provided with weldiing joints(include for the supply of bolts, gutter bolts, screws,washers, pipe nails, distance pieces, plugs, and all jointing materials, and also for all necessary cutting of gutters and pipes, drilling for bolts and jointing and fixing in position.). Note:- work is to be executed at height ofApprox 10-15 meter. 9 Cutting holes in brick wall Exc. half brick but not exc. one brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required for cooler stand,complete all as specified and directed 10 M&L for prepration of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. 11 M&L for brick work with sub class B bricks, straight or curved on planexc 6 m mean radius built in cement mortar 1:6, complete all as specified anddirected by Engineer-in-Charge. 12 M&L for brick work with sub class B bricks, straight or curved on planexc 6 m mean radius built in cement mortar 1:4, complete all as specified anddirected by Engineer-in-Charge. 13 M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 , finished even and smooth without using extra cement, complete all as specified anddirected by Engineer-in-Charge. 14 M&L for Preparation of new plastered wall surfaces and applying two coats of cement paintcomplete all as specified and directed by the Engineer-in-Charge. 15 Demolition ofBrick work masonry or stone/ boulder masonry, built in cementmortar including all quoins, arches, pillars, etc, complete all as specified and directed. 16 M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint in camouflage pattern of any description over and includingone coat of primer all as specified & directed by Engineer-in- Charge. 17 M&L for dismantling wrought iron or mild steel work of any description no otherwise provided for 18 M&L Rolled mild steel work as in Roof trusses (framed), trussed purlins (angle, channel or flat) incl cleats. Complete with grade of steel Fe-410-00 (Grade E-250). Complete all as specified and directed by Engr in Charge. 19 Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings & removing from site. 20 S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile streangth of 550 Mpa as in roof covering cladding to wall , fixed with self tapping screws as specified. 21 Demolition of cement concreteunreinforced in groundfloors andpavingsnot exc 15cm thickness below or above ground level etc all as specified and as directed by Engineer-in-Charge. 22 M/L PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub bases, 75 mm thick. Complete all as specified and directed by Engr in Charge. 23 M &L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigments incl a layer of 25 mm thick sand filling. Complete all as specified and directed by Engr in Charge. 24 Dismantling of floor hearth or wall tiling and Stone floor including cement mortar bedded (but not backing) & removing serviceable tiles to store and rubbies of the premises 25 M&L for Vitrified ceramic tiles 10mm thick (square/ rectangular) area of each tile not exceeding 0.36 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white or colour cement to match with and including provision of 15 mm thick screed bedding in CM (1:6), complete all as specified and directed. 26 M&L for Vitrified ceramic tiles 10 mm thick ( Square/ rectangular) area of each tiles not exceeding 0.36 Sqm in vertical surfaces such as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including provision of backing coat of 10mm thick in CM (1:4), complete all as specified and directed. 27 M&L 25mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl 20 mm thick screed in CM 1:4. Complete all as specified and directed by Engr in Charge. 28 Demolition of cement concreteunreinforced in groundfloors andpavingsnot exc 15cm thickness below or above ground level and removing rubbish from the premises etc. Complete all as specified and as directed by Engineer-in-Charge. 29 M&L for rendering 10mm thick plaster on brick or concrete surfaces in cement mortor (1:6) finished the surface even and smooth without extra cement. Complete all as specified and directed by Engr in Charge. 30 M&L for 5 mm thick, plaster in cement mortar (1:3) on surfaces of ceilingand finishing the surface even and smooth without using extra cement all as specified & directed by Engineer-in-charge. 31 M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer all as specified & directed by Engineer-in- Charge. 32 M&L for preparing old painted surfaces by washing, rubbing down and stopping of distempered and painted surfaces and applying a one coat of oil bound distemper on surfaces of walls complete all as specified & directed by Engineer-in-charge. 33 M&L for II nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed 34 S& F 25mm thick , Block boards, grade 1 quality, exterior grade, decorative type with decorative face veneers on both faces, fixed with screws to timber frame-work.Complete all as specified and directed by Engr in Charge. 35 S&F Secound Class Hardwood, plain fillets square rectangular or trangular in section wrought sectional area exceeding 13 sqcm and n exc 25 sqcm fixed with nails,bullnosed, splayed, chamfered or rounded on one edge or face 36 S&F Hasp and staple, 100 mm allumuniun anodised, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws 37 S&F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flaps 40mm ( when open). Complete all as specified and directed by Engr in Charge. 38 S&F 40 mm knobs of brass, polished fixed with nut screw &washer bright finished. Complete all as specified and directed by Engr in Charge. 39 S&F in repair curtain rail, mild steel, chromium plated with fixing brackets, stops roller etc. all as specified & directed by Engineer-in-charge. 40 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth. Complete all as specified and directed by Engr in Charge. 41 S&F Medium grade GI tubing 15 mm bore with all fittings , to walls, ceiling or laid in floors etc. Complete all as specified and directed by Engr in Charge. 42 -Ditto- all as per item as above here in before but in 20mm bore pipe 43 S&F gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed in repairs to 15 mm bore pipe. Complete all as specified and directed by Engr in Charge. 44 S&F gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed in repairs to 20 mm bore pipe. Complete all as specified and directed by Engr in Charge. 45 S&F in repairs bib taps cast copper alloy chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and Complete all as specified and directed by Engr in Charge. 46 M&L CP Fancy type Pillar cock 15mm bore cast copper alloy with capstan heads rocket type with areator fixed in repair. Complete all as specified and directed by Engr in Charge. 47 S&F, Powder coated, anodised aluminium frame for door, window and ventilator including necessary jointing cleats. Complete all as specified & directed by Engineer-in-charge. 48 M & L for powder coated, Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specifiedNote: Glass shall be measured and paid seperately. 49 M & L for powder coated, Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specifiedNote: Glass shall be measured and paid seperately. 50 M&L for sheet glass 5.5mm thick, ordinary quality and glazing with, rubber packingexc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge 51 M&L Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufactures. Complete all as specified and directed by Engr in Charge. 52 S&F 2 levers brass mortice lock vertical type, size 100mm including escutcheon plates and two keys complete all as specified & directed by Eng-in-Charge 53 S&F Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed. Complete all as specified and directed by Engr in Charge. 54 S&F for anodised aluminium snap grid 605 x 605 mm frame work for false ceiling with sections as per Clause 10.38 of SSR Part-I (2009). Complete all as specified and directed by Engr in Charge. 55 M&L for exposed metal frame ceiling with 8mm calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) 56 S&F Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified 57 S&F Solid PVC wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. 58 S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling fixing to wall to make PVC Frame as per specification and drawing. 59 S&F PVC connections 450 mm long 15 mm size with PTMT nuts. Complete all as specified and directed by Engr in Charge. 60 S&F PVC (SWR) pipes of 75 mm dia, single socket fixed to walls. Complete all as specified and directed by Engr in Charge. 61 M&L Cutting openings, through brick walls for door, window and other openings or nlarging existing openings. converting window into door openings, etc. or cutting outdefective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks,removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m 62 Demolition of reinforced concrete of any description and n any position not other wise specially provided for 63 M & L for RCCM- 25 using 20 mm graded crushed stone coarse aggregatein slabs supported on walls and in shelves and the like etc complete all as specified and directed 64 M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) 65 S&F,door closer hydraulically regulated, designation No. 3, universal type, aluminium extruded sec body suitable for door shutters of 851 to 1000 mm in width and of weight between61 to 80 kg and fixed. Complete all as specified and directed by Engr in Charge. 66 M&L for counterr top viterous China wash hand basin, white, oval type incl waste coupling CP 32mm dia,PVC waste pipe 32mm dia & CP gretting with holes complete all as specified and directed by Engr-in-chardge. 67 M & L foranodised Aluminium frame works such as grills with frames and frame guard bars and similar works. Complete all as specified and directed 68 Excavation in trenches n exc 1.5 m wide and n exc 1.5 depth for foundations etc and getting out as in hard / dense soil complete all as specified and as directed. 69 Excavation in trenches n exc 1.5 m wide and n exc 1.5 depth for foundations etc and getting out as in soft / loose soil complete all as specified and as directed. 70 M&L cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in fdn and mass concrete complete all as specifed and directed. 71 M & L for Plain cement concrete type B1 1:2:4 ( using 20 mm graded granite stone aggregate) as in copings, bed plates and the like including weathering, slightly surface.complete all as specified and as directed. 72 Returing, filling in including spreading, levelling , watering and well ramming in layers n exc 25 cm thick with hard/dense soil complete all as specified and as directed. 73 Removing of excavated material exc 50 m but n exc 250m and depositingwhere directedcomplete all as specified and as directed. 74 M & L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms molds, mitered/stopped ends etc. complete all as specified and as directed. 75 M & L for P.C.C 1:2:4 type B1 (using 20 mm graded stone aggregate) as in surface channels and drain, complete all as specified and as directed. 76 M & L for precast Reinforced cement concrete type B-11:2:4 (20mm graded aggregate) and set in Cement Mortar (1:4) as indrain cover slabs including necessary form work complete all as specified and directed. (Reinforcement shall be measured and paid seperately). 77 M & L TMT bars10 mm dia and cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. 78 S&F Framed work such as grills, gratings, cooler stand / fire point stand etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings;famework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specifiedand directed. 79 Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary of tender documents.