Tender For Provn Of Stp At Af Stn Bihta, bihta-Bihar

Military Engineer Services has published Tender For Provn Of Stp At Af Stn Bihta. Submission Date for this Tender is 13-08-2025. Sewage Treatment Plant Tenders in bihta Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

50315874
Corrigendum : Tender For Provn Of Stp At Af Stn Bihta
Tender
Indian
Bihar
Bihta
13-08-2025

Tender Documents

Tender Details

Tender For Provn Of Stp At Af Stn Bihta; 1 SCHEDULE A PART I (BUILDING WORKS) 2 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartI . 3 SCHEDULE A PART II (INTERNAL WATER SUPPLY) 4 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartII. 5 SCHEDULE A PART III (INTERNAL ELECTRIFICATIONS) 6 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartIII. 7 SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) 8 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartIV . 9 SCHEDULE A PART V (EXTERNAL ELECTRIFICATION) 10 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartV 11 SCHEDULE A PART VI (SEWAGE DISPOSAL) 12 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartVI 13 SCHEDULE A PART VII (AREA DRAINAGE) 14 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartVII 15 SCHEDULE A PART- VIII (ROAD/PATH AND CULVERT) 16 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartVIII 17 SCHEDULE A PART- IX (COMPOUND WALL, FENCING AND GATE) 18 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part IX 19 SCHEDULE A PART- X (EARTHWORK AND SITE CLEARANCE) 20 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part X 21 Sch A PartXI (Miscellaneous Items of B/R and E/M) 22 Design, supply, installation, testing and commissioning of sewage treatment plant (STP) fully automatic alongwith SCADA (without sample analyser) of STP following capacity with following specifications :- 23 Sewage treatment plant (STP) having capacity of 200 cum/day (KLD) at AF Stn Bihta including all civil work electrical, mechanical, control and instrumentation works alongwith provn ofrequired LT panel, pump as based on latest CPCB norms & rating for STP and other allied equipment for STP as per OEM to achieve the parameter as mentioned in tender documents. Parameters for treated water are encl. Parameters of Raw sewage as given in Annexure- I are tentative however contractor should test the raw sewage at their endfrom any auth Govt lab (NABL accredited) and STP should be designed accordingly to discharge treated water as per parameters specified in tender documentsNotes :-(i) There is no embargo on the technology to be used for sewage treatment scheme. Any technology selected for STP should also take accountability of the expertise in the area, Life cycle cost of the STP and intended reuse of treated waste water STP shall be provided as per parameters as per Annexure.(ii) Bidder will submit detailed drg/design/hydraulic diagram/tech data duly vetted by IIT/NIT to GE (AF) Bihta for approval of scheme/drg by CWE(AF) Bamrauli.(iii) Scope of work include complete civil, electrial and mechanical work alongwith treated water tank of detention time 4 hours, mechanical and electric work pertaining to STP plant including Raw sewage collection sump suitable for 200 KLD capacity plant. The scope also includes LT Panel for STP. Panel should have incoming/outgoing MCCB and other protective/ operational devices as to be designed by contractor/OEM/consultant for operation of the plant. 24 (iv) Contractor will keep a stock of spares as required to changed periodically as per OEM. The spare parts required to changed should be easily available in market and no foreign spares to be used in the STP.(v) In case bidder select MBBR technology then equilization tank of suitable capacity to be provided at site. 25 The rate for manning portion will be measured and paid seperatly under respective item. Rates quoted by the contractor shall also be inclusive for following items :-(i)Contractor shall provide all type of tool kits as required for maintenance of STP installation.(ii)Minor stores required for maintenance should be provided by the contractor as directed by Engr-in-Charge.(iii)Contractor shall provide process and line diagram of STP plant on SS Board of size 4 feet 3 feet including capacity and specification of STP. 26 Lifting Man hole Pump :- Design, Supply, installation, testing and commissioning of vertical non-clogging type wet pit application pump suspended by vertical column pipe which protect the transmission shaft. Pumps having solid handling capacity of upto 30 mm size particles having CI casing & impeller complete with all accessories, motor of required capacity, delivery header with isolation valve, pressure gauge with isolation cock, level controller (with wiring) to control, etc. including suitable size of submersible cable from control to motor panel complete all as specified and directed by engineer-in-charge for following requirement sizes:- Make: CRI, Grundfos, Kirloskar, Wilo, XylemNOTE :-The qtymentioed are tentative and can be varried as per the design submitted by the bidder. 27 4.67 m3/hr discharge at 10 MWC, (1 W +1S), Peak Flow 28 1.17 m3/hr discharge at 10 MWC (1W +0S), Avg Flow 29 5.53m3/hr discharge at 10 MWC(1W +1S), Peak Flow 30 1.38 m3/hr discharge at 10 MWC(1 W +0S), Avg Flow 31 9.43 m3/hr discharge at 10 MWC (1 W +1S), Peak Flow 32 2.36 m3/hr discharge at 10 MWC, (1 W +0 S), Avg Flow 33 INTERMEDIATE SUMP 1&2 :- Design, Supply, installation, testing and commissioning (SITC) of vertical non-clogging type wet pit application pump suspended by vertical column pipe which protect the transmission shaft. Pumps having solid handling capacity of upto 30 mm size particles having CI casing & impeller complete with all accessories, motor of required capacity, delivery header with isolation valve, pressure gauge with isolation cock, level controller (with wiring) to control, etc. including suitable size of submercible cable from control to motor panel complete all as specified and directed by engineer-in-charge. required for following intermideate sumps :-Make: CRI, Grundfos, Kirloskar, Wilo, Xylem.NOTE :-The qtymentioed are tentative and can be varried as per the design submitted by the bidder. 34 15.22 m3/hr discharge at 10 MWC (1W +1S), Peak Flow INTERMIDEATE SUMP -1 35 3.81 m3/hr discharge at 10 MWC (1W +0S), Avg Flow INTERMIDIATE SUMP-1 36 25.88 m3/hr discharge at 10 MWC (1W +1S), Peak Flow INTERMIDEATE SUMP-2 37 6.47 m3/hr discharge at 10 MWC (1W +0S), Avg Flow INTERMIDATE SUMP-2 38 Material & labour of ductile iron pressure pipes having K-9 class, 100 mm Nominal bore, conforming to IS 8329: 2000,having socket & spigot end with necessary fitting i.e. tee,bend,socket etc. including pipe specials complete all as specified and directed by engineer-in-charge. 39 M & L for sludge transfer 50 mm Nominal bore,MS ERW CLASS- C Piping of including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories, duly insulatedcomplete all as specified and directed by the engineer-in-charge. 40 M & L for sludge transfer 80 mm Nominal bore,MS ERW CLASS- C Piping of including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories, duly insulatedcomplete all as specified and directed by the engineer-in-charge. 41 M & L for sludge transfer 100 mm Nominal bore,MS ERW CLASS- C Piping of including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories, duly insulatedcomplete all as specified and directed by the engineer-in-charge. 42 Supply, installation, testing and commissioning of50 mm nominal bore wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 43 Supply, installation, testing and commissioning of80 mm nominal bore wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 44 Supply, installation, testing and commissioning of100 mm nominal bore wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 45 Supply, installation, testing and commissioning of 50 mm nominal bore wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 46 Supply, installation, testing and commissioning of 80 mm nominal bore wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 47 Supply, installation, testing and commissioning of 100 mm nominal bore wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 48 S & F of 4 bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar complete with accessories, etc. as specified and directed by engineer-in-charge.Make: General, WIKA, TSI 49 Supply, installation, testing and commissioning of CPRI approved load-break/fault-make switch with TAG type HT HRC fuse, fuse trip mechanism, earth switch with interlock with the main drive mechanism, shunt trip coil (220 V, 50 Hz, AC) and electrical standard indications, conforming to IS 9920/ IEC 62271-2002 and having the following specifications for outdoor floor mounted installation including plateform as per manufacturer recommendation as specified and directed by the engineer-in-charge. 50 [i] Type of Break: Air Break 51 [ii] Rated Voltage: 12 kV 52 [iii] Rated Frequency: 50 Hz 53 [iv] Rated Current: 630 A 54 [v] Rated Peak Current: 85 kA 55 [vi] Rated Short time Current: 31.5 kA (for 1 sec.) 56 [vii] Rated Making Current: 80 kA 57 [viii] Rated breaking Current: 630 A 58 [ix] Impulse Voltage wave shape 1.2/50 µs: To Earth: 75 kV; Between Poles: 75 kV; Between Open Contacts: 85 kV 59 [x] Power Frequency Test Voltage: To Earth: 35 kV; Between Poles: 35 kV; Between Open Contacts: 45 kV 60 [xi] Breaking of Capacitive Load: 50 A 61 [xiii] Closed Loop Breaking Current cos φ = 0.31 MD 62 [xiv] Rated Transformer Off Load Breaking Capacity = 120 A 63 [xv] Rated Line Charging Breaking Capacity: 90 A 64 [xvi] No. of Poles: 3 65 [xvii] No. of Breaks per Pole: Single 66 [xviii] Degree of Protection: IP 65 67 S & F 45W LED street-light having pressure die-cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection, including necessary electrical connections to the fitting with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer all as specified and directed. [Make: BAJAJ Cat-Part No. 169799 BRTFG 45W LED ,Havelles Cat-Part No. ENDURAPEARLNEOSL45WLED757PASYTOPC, Crompton Cat-Part No. LSTP-45-CDLor equivalent] 68 S & F weather- proof PVC junction box of size 250 mm x 200 mm x 100 mm, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos. of polymide gland with check nut (M-32- 3 Nos.) fixed on poles with flat aluminium clamps of size 20 mm x 3 mm, nuts, bolts, washers, etc. complete all as specified and as directed. [Make: SINTEX Cat-Part No. GS-JB-2817, ENYCASE Cat-Part No. KF5350, HENSEL Cat-Part No. JSN250 or equivalent] 69 Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical type PLC based (LIFTING MANHOLE - 27 Panel) of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 55 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. ( LIFTING MANHOLE - 27 Panel) 70 The Panel shall comprise of the following: 71 [a] Busbar Chamber: 72 [i] Aluminium busbar of 80A capacity, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) 73 [a] Incoming: 74 [i] 16 A, 415 V, Ics = Icu =10 kA, 50 Hz, FP MCB - 01 Nos. 75 Programmable Logic Controller (PLC) Feeder 76 PLC Unit - 01 No. with Power Supply Unit 77 [b] Outgoing: 78 [i] 0.5 HP Starter with 1.6A, 100kA, TM Release MPCB - 2 No. 79 [ii] 0.2 HP Starter with 1A, 100kA, TM Release MPCB - 1 No. 80 Ultrasonic Sensor - 03 Nos. 81 Panel Enclosure 82 Size :- 600MM (W) x 700MM (H) x 300MM (D) 83 Fabrication:- 3.15 mm CRCA sheet 84 Pre Treatment : 7 tank process 85 Painting : Powder coated with RAL7032 86 Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical type PLC based LIFTING MANHOLE - 123 Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 55 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. ( LIFTING MANHOLE - 123 Panel) 87 The Panel shall comprise of the following: 88 [a] Busbar Chamber: 89 [i] Aluminium busbar of 80A capacity, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) 90 [a] Incoming: 91 [i] 16 A, 415 V, Ics = Icu =10 kA, 50 Hz, FP MCB - 01 Nos. 92 Programmable Logic Controller (PLC) Feeder 93 PLC Unit - 01 No. with Power Supply Unit 94 [b] Outgoing: 95 [i] 1 HP Starter with 2.5A, 100kA, TM Release MPCB - 2 No. 96 [ii] 0.2 HP Starter with 1A, 100kA, TM Release MPCB - 1 No. 97 Ultrasonic Sensor - 03 Nos. 98 Panel Enclosure 99 Size :- 600MM (W) x 700MM (H) x 300MM (D) 100 Fabrication:- 3.15 mm CRCA sheet 101 Pre Treatment : 7 tank process 102 Painting : Powder coated with RAL7032 103 Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical type PLC based LIFTING MANHOLE - 88 Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 55 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. ( LIFTING MANHOLE - 88 Panel) 104 The Panel shall comprise of the following: 105 [a] Busbar Chamber: 106 [i] Aluminium busbar of 80A capacity, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) 107 [a] Incoming: 108 [i] 16 A, 415 V, Ics = Icu =10 kA, 50 Hz, FP MCB - 01 Nos. 109 Programmable Logic Controller (PLC) Feeder 110 PLC Unit - 01 No. with Power Supply Unit 111 [b] Outgoing: 112 [i] 1 HP Starter with 2.5A, 100kA, TM Release MPCB - 2 No. 113 [ii] 0.2 HP Starter with 1A, 100kA, TM Release MPCB - 1 No. 114 Ultrasonic Sensor - 03 Nos. 115 Panel Enclosure 116 Size :- 600MM (W) x 700MM (H) x 300MM (D) 117 Fabrication:- 3.15 mm CRCA sheet 118 Pre Treatment : 7 tank process 119 Painting : Powder coated with RAL7032 120 Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical type PLC based INTERMEDIATE SUMP-1 Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 55 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. ( INTERMEDIATE SUMP-1 Panel) 121 The Panel shall comprise of the following: 122 [a] Busbar Chamber: 123 [i] Aluminium busbar of 80A capacity, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) 124 [a] Incoming: 125 [i] 16 A, 415 V, Ics = Icu =10 kA, 50 Hz, FP MCB - 01 Nos. 126 Programmable Logic Controller (PLC) Feeder 127 PLC Unit - 01 No. with Power Supply Unit 128 [b] Outgoing: 129 [i] 2 HP Starter with 4A, 100kA, TM Release MPCB - 2 No. 130 [ii] 0.5 HP Starter with 1.6A, 100kA, TM Release MPCB - 1 No. 131 Ultrasonic Sensor - 03 Nos. 132 Panel Enclosure 133 Size :- 600MM (W) x 700MM (H) x 300MM (D) 134 Fabrication:- 3.15 mm CRCA sheet 135 Pre Treatment : 7 tank process 136 Painting : Powder coated with RAL7032 137 Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical type PLC based INTERMEDIATE SUMP-2 Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 55 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. ( INTERMEDIATE SUMP-2 Panel) 138 The Panel shall comprise of the following: 139 [a] Busbar Chamber: 140 [i] Aluminium busbar of 80A capacity, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) 141 [a] Incoming: 142 [i] 16 A, 415 V, Ics = Icu =10 kA, 50 Hz, FP MCB - 01 Nos. 143 Programmable Logic Controller (PLC) Feeder 144 PLC Unit - 01 No. with Power Supply Unit 145 [b] Outgoing: 146 [i] 3 HP Starter with 6.3A, 100kA, TM Release MPCB - 2 No. 147 [ii] 1 HP Starter with 2.5A, 100kA, TM Release MPCB - 1 No. 148 Ultrasonic Sensor - 03 Nos. 149 Panel Enclosure 150 Size :- 600MM (W) x 700MM (H) x 300MM (D) 151 Fabrication:- 3.15 mm CRCA sheet 152 Pre Treatment : 7 tank process 153 Painting : Powder coated with RAL7032 154 S & F ISI marked 16 A, SP, C- curve MCB for AC applications till following capacity, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed. Make: Schneider, Legrand, Havells 155 Design, Engineering, Supply, Install, Testing and Commissioning ofsilent Diesel engine driven Generating set of minimum capacity50 KVA, 415 Volts, 3 Ph, 4 wire, 50 Hz engine as per IS:10002 and alternator as per IS:13364 complete with relay panel and switchgears for automatic starting on mains failure, control panel and sound proof canopy as per CPCB norms, necessary earthing pits, connections and foundation, platform all as per manufacturer recommendations,etc all as specified and directed.Make:Kirloskar, Crompton Greves, Cummins or other make approved by GE 156 DG set should be CPCB–IV norms complaint. Emission limit (g/kW-hr) standard shall be as under:- 157 The DG Set & AMF Panel shall be wired, interlinked & logically controlled with commercial supply for uninterrupted supply to the Essential Services LT Panel. 158 S & F 10 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: BAJAJ Cat-Part No. 112407 BCLSB 10 WH or equivalent model of Havells, Philips or Wipro 159 S & F 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.Make: BAJAJ Cat-Part No. 112785 BCLAB 20W or equivalent model of Havells, Philips or Wipro 160 S & F 20 W LED buildingsecurity light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 100 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Copper conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed. Make: BAJAJ Cat-Part No. BAJAJ 169799 BRTFG 45W LED I or equivalent model of Havells, Philips or Wipro 161 S & F BLDC five star rated energy efficient high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. Make: Crompton Cat-Part No. ENTRUST50 or Havells Cat- Part No. ES-50 or equivalent model of Usha or BAJAJ 162 S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10 or equivalent model of Usha, Havells or BAJAJ 163 S & F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 6000 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No.EXHD450- 4-1 or equivalent model of Usha, Havells or BAJAJ 164 S & F ISI marked MCB for AC applications 6 A SP C Curve type, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed. 165 S & F ISI marked MCB for AC applications 63 Amp DP C Curve type, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed. 166 Supply and laying SFRC Manhole cover complete all asspecified 167 S & F 150mm Wide PVC Water Bar complete all as specified and directed. 168 M & L for providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 7 conforming to IS : 8329 : 100 mm dia Ductile Iron Double Flanged 169 M & L for Cutting of PQC/PCC road to the width and depth required for laying RCC NP3 pipe of sewage line including hacking banching and including making good to top surface of road width 170 M & L for Cutting of bituminous road to the width and depth required for laying RCC NP3 pipe of sewage line including hacking banching and including making good to top surface of road width 171 Supply and fix chain pulley block capacity 02 ton with tripod mannual type including suitable size of MS chain for lowering and lifting complete all specified and directed 172 M & L for cutting holes in RCC walls exceeding 150 mm thick and not exceeding 230 mm thick making joints for drain pipes including making good the cutting surface using cement concrete (using 12.5 mm graded stone aggregate), complete all as specified and directed by Engineer - in - Charge. 173 Supply, installation, testing and commissioning of Submersible treated water pump capable of100 m3/hr discharge at 30 MWC head having CI casing & impeller complete with all accessories, motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply, pressure gauge with isolation cock, isolation valve, NRV on delivery line, strainer at suction. mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve, etc. complete all as specified and directed by engineer-in-charge. (1 W+ 1 S) 174 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 175 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 176 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 177 NOTE FOR ITEM NO 164to 166:-THE QUOTED RATE SHALL BE DEEMED TO INCLUDED THE FOLLOWING OPERATIONS :-(a) These item shall be executed during the defect liability period of 24 months after completion of Phase I, contractor shall quoted the rate accordingly.(b) All consumable items as well as parts such as Sodium Hypo chlorite and any other chemical required, compressor oil, grease etc required for operation of plant shall be provided by contractor at his own cost as per the manufacturers instructions and direction of GE during the period of Manning & Operation. Cost of the same shall be deemed included in the unit rates quoted by contractor as overed onder defect liability period. 178 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 179 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 180 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 181 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 182 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 183 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 184 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 185 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 186 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 187 NOTE FOR ITEM NO 168 to 176 :- (a) These item shall be executed after the defect liability period of 24 months after completion of Phase II, contractor shall quoted the rate accordingly.(b) All consumable items as well as parts required for M & O afterthe defect liability period shall be issued by the department as free for fixing.(c) The contractor shall enter in to MOU with OEMs for the provision of STP plant and further for M &O (During the defect liability period and after the defect liability period as catered in tender and the same shall be submitted by the bidder before issue of completion of phase I.(d) THE QUOTED RATE SHALL BE DEEMED TO INCLUDED THE FOLLOWING OPERATIONS :- 188 (i) Preventive and breakdown maintenance of all the equipments by regular oiling greasing chaging of gland packing, replacement of nuts and bolts etc during th eperiod of work order.(iii) To maintain the instalaltions provided under this contract as per PCB norms/standard Engineering pratice.(iv) Sapre parts if any required for operation/amintenance of sewage treatment plant during the currency of defect liability period shall not be included in the rate quoted.(v) Periodiocal maintancence shall be carried out by the authorised representative of the original equipment manufacturer(OEM) 189 (vi) Electric and water for operation of the plant will be supplied by the department free of cost.(vii) Operation of raw sewage pump, air blowers, filler feed pump, dual media filter activate carbon filter(if applcable), dosing sysyem, ultra filtration system(if appilcable)& control panel.(viii)Removing of material arrested at bar screeen.(ix) Removing of oil floating at surface.(x) Change over from one pump to another daily on requirment.(xi) Change over from one blower to another blower on requirment.(xii) Cleaining of air filter of blower regularly on requirment basis. 190 (xiii)Applying grease to all motors blowers periodically including supplying of suitable quality of grease as per site requirement. (xiv) Draining of sludge from MBBR reactor once in a month to avoid chocking of air guard. (xv)Removing of sludge from settler depending upon the actual load. (xvi)Maintaining of log books for records operation of plants including cost of stationary. (xvii) Back wash offilter and activate carbon filter weekly. (xviii)Screeing of inlet and outlet mesh boxreactor weekly.(xix) Washing to tube media with low pressure out of raw water required. (xx)Draining of burn out lubricant oil and refilling of appropriate lubricate oil in air blower after 2000-2500 operation including cost of lubricant. (xxi) Maintenance and operation of filter press and collection output neatly / A-05/P-165.(xxii) STP operation of standby DG set and when required.(xxiii)STP operating clear water pumps regularly and in consultation with Engineer-in-Charge.(xxiv) Oteh maintenance work as per instruction of Engineer - in - Charge. 191 NOTE FOR ITEM NO 164 TO 176 :- Contractors quoted rates for the above items shall be deemed to include the cost of following also :-(a)Testing of treated water :The treated water shall be got tested by the tenderer once in a month from regional Govt Lab / other approved lab.Samples shall be collected in the presence of Engr-in-Charge and test reports shall be submitted to Engr-in-Charge in original for record purpose.If parameters of tested water are beyond the limits mentioned in PS or Contractor failed to carryout the required tests the recovery at double the quoted rates of the Contractor for the entire month for M & O shall be made from the Contractor. (b) Maintain the safety and security measures of the palnt. (c)Keep the installation neat and tidy. (d)Decision of GE shall be final and binding on account of quality and quantity of material/ chemicals required for maintenance and operation of the plant.All materials brought at site and incorporated in work during the defect liability period shall b ekept in record purpose duly indicated with relevant purchase vouchers and test certificates. (e) Disposal of treated sewage/sludge as directed by Engr-in-Charge.(f) Efficient treatment of the sewage water shall be ensured by the Contractor and required characterstics of outlet treated sewage shall be as specified in PS.(g) The contractor shall be responsible for watch and guard of installations round the clock 24 hours. Any loss or damage to the plant, uipmen tinstalled and Govt. property in the Pump house premises shall be made good/borne by e contractor. (h) Operating connected accessoriess such as all type of sluice valve & connecting accessories shall be deemed included in the unit rates quoted by contractor. 192 (j) Testing of earthing of machinary/equipment shall be carried out on monthly basis as directed.(k) If any loss or damage takes place to the equipment, machinery, tools, stores, fitting and fixtures etc or any other equipment installed in the pump house premises during the contract period, the same shall be made good/borne by the contractor. (l) The contractor will submit the complete details of the tradesmen alongwith their ualification certificate before commencement of work. (m) General cleanliness and upkeeping the existing pump house including getation within the primises of pump houses/sumps are aupto 5 Mtrs all round within the and ary walls by deploying manpower with T&P if required, at any time all as directed.(n) Please ensure that all trademen engaged in subject work covered in EPF scheme. Proper doc should be maintained in this regard and submitted alongwith each payment.(o) The expense incurred due to insurance and EPF scheme for the staff deployed by the contractor for manning & operation shall also be deemed included in the quoted rates of BoQ. Nothing extra shall be admissible in this account. (p) Contractors quoted rates hall be deemed to include removal of dried sludge and its disposal outside MD land during the M&O period as directed by Engineer-in-Charge. (q) Testing of incoming sewage and treated sewage shall be done by the contractor from any Govt. approved lab as approved by GE on a monthly basis during the M & Operation test report shall be submitted to GE.Contractors quoted rate shall be deemed to include for the same 193 (r) In case contractor fails to employ the duty person in any of the shift, he shall be liable to be the recovery @ Rs 1000/-per shift and No payment shall be made for that shift. (s) If any loss or damage takes place to the equipment, machinery, tools, stores, fitting and fixtures etc or any other equipment installed in the pump house premises during the contract period, the same shall be made good/borne by the contractor. (t) The contractor will submit the complete details of the tradesmen alongwith their ualification certificate before commencement of work. (u) Unit rates inserted are inclusive of minimum wages as per latest notifications, Labour Welfare Cess @1% and GST @ 18%. (v) The items required for comprehensive maintenance after DLP shall be supplied by the department by the concern GE as per requirement. 194 (vi)Contractor shall provide all type of tool kits as required for maintenance of STP installation.(vii)Contractorshall provide two set of uniform with name plate and one mobile set duly recharged of each operator & helper .(viii)The log sheets will be maintained by the operator in installations & contractor shall provided Log Book, Attendance register, Plant running record book and rate quoted by the contractor shall deemed to included in his quoted rates.(ix)The contractor will be responsible for upkeep of the installation in neat and tidy conditions and in a presentable manner. The surrounding of the installation will also be maintained neat and clean by removing grassesand other vegetation.(x)Greasing, lubricating of all equipment of installation including cleaning of screen bar, oil grease trap as directed by Engr-in-Charge.(xi)The site documents such as log sheet, Attendance etc will be checked by daily by JE, weekly by Engr-in-Charg and monthly by GE.(xii)Technical qualification of operator in ITI Pass in electric/Engine fitter from Govt institution with 3 years experience in related trade .(xiii)Minor stores required for maintenance should be provided by the contractor as directed by Engr-in-Charge. 195 (xiv)Contractor shall submit all documents within one month such insurance cover, EPF, ESI, Police verification of all the workers employed by him.(xv)Testing of earthing of each equipment and record will be produce to Engr-in-Charge in each 6 months, testing equipment will be provide by contractor. Watering with salt in each earthing for obtaining the result less than 1 ohms.(xvi)Operator will be working at site all safety precaution, in case my accident/injury of any person deputed by contractor shall be fully responsible for setting all claims/compensation.(xvii)The chemicals required for treatment /disinfection of water will be provided by the contractor. Water treatment/disinfection shall be done timely and quality of water will be checked as per IS specification before supplying to users. Penalty will be imposed to contractor in absence of chemical dozing Rs 200/day.(xviii)If any slackness noticed a suitable action shall be initiated as per the existing rule and contract is liable to be terminated.(xix)Contractor will employee addition employee for rest/leave.(xvi)Proper handing/taking over of operator to be done and operator should not leave the installation before arrival of next operator. 196 S & F of20 mm Nominal bore CL 150 # rated ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories complete all as specified and directed.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 24-07-2025 Amdt No 1 Other 13-08-2025
2 24-07-2025 CORR NO 1 Other 13-08-2025

Key Value

Document Fees
INR 3000 /-
EMD
INR 802000.0 /-
Tender Value
INR 9.53 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail