Tender For Electrification Of Phc At Bemdoora (Voi Bemdoora)- 1 Point wiring for switch controlled primary lighting points with 3x1.5 sq mm (P+N+E)FRLS PVC Insulated flexible stranded copper conductor wires of Polycab/Havells/ Anchor/ Finolex make in recessed or surface conduiting system, incl. the cost of supplying and fixing of metallic modular grid plate mounted flush, 240 volt 6A control switch housed in zinc chromate passivity Gl box with modular cover plate complete as per specifications and as required. The job includes providing and laying of circuit wiring with 3x1.5 sq mm PVC insulated multistranded copper wire laid through PVC conduit from DB to first switch in sub circuit, excl. cost of conduit. (C. job). Separate wiring for normal and inverter supply is to be provided and no extra circuit wiring shall be paid what so ever reason or length. 2 Point wiring for switch controlled primary lighting points with 3x1.5 sq mm (P+N+E)FRLS PVC insulated flexible stranded copper conductor wires of Polycab/Havells/ Anchor/ Finolex make in recessed or surface conduiting system, incl. the cost of supplying and fixing of metallic modular grid plate mounted flush, 240 volt 6A control switch and 240 volt 300watt stepped electronic speed regulator housed in zinc chromate passivity Gl box with modular cover plate complete as per specifications and as required. The job includes providing and laying of circuit wiring with 3x1.5 sq mm PVC insulated multistranded copper wire laid through PVC conduit from DB to first switch in sub circuit, excl. cost of conduit. (C. job), Separate wiring for normal and inverter supply is to be provided and no extra circult wiring shall be pald what so ever reason or length. 3 Point wiring for 10A socket out lets with 3x2.5 sq mm (P+N+E)FRLS PVC Insulated 660/1100volt grade flexible stranded copper conductor wires of Polycab/ Havells/Anchor/ Finalex make in recessed or surface conduiting system, incl. the cost of supplying and fixing of metallic modular grid plate mounted flush, 3 no. 240 volt 6A S pin socket out lets along with 3 no. 6A control switch housed in zinc chromate passivity Gl box with modular cover plate complete with internal connections, loop earthing wire of same size as per specifications and as required. The job includes providing and laying of circuit wiring with 3x2.5 sq mm PVC Insulated multistranded copper wire laid through PVC conduit from DB to first switch in sub circuit, excl. cost of conduit. (C job). Separate wiring for normal and inverter supply is to be provided and no extra circuit wiring shall be paid what so ever reason or length. (Maximum two points shall be connected on one circuit) 4 Point wiring for 16A socket out lets with 3x4 sq mm (P+N+E)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires of Polycab/ Havells/Anchor/ Finolex make in recessed or surface conduiting system, incl. the cost of supplying and fixing of metallic modular grid plate mounted flush, 240 volt 16A 6 pin combined shuttered socket out lets along with 240volt 16A control switch housed in zinc chromate passivity Gl box with modular cover plate complete with internal connections, loop earthing wire of same size as per specifications and as required. The job includes providing and laying of circuit wiring with 3x4 sq mm PVC insulated multistranded copper wire laid through PVC conduit from DB to first switch in sub circuit, excl. cost of conduit. (C. job). Separate wiring for normal and inverter supply is to be provided and no extra circuit wiring shall be paid what so ever reason or length. (Maximum two points shall be connected on one circuit) 5 Supply, installation, testing and commissioning of 10Watt LED bulb with holder and PVC base block/ base plate. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of six months reckoned from the date of successful commissioning/ handing over of site to the intending department. 6 Supply, installation, testing and commissioning of1200 mm sweep ceiling fans of Havells/ Crompton Greaves/Bajaj/ Usha (Sample to be got approved), incl. cost of ceiling rose (if required) and making of necessary connections. 7 Supply, installation, testing and commissioning of 200 mm sweep shutter type exhaust fans of Havells/ Crompton Greaves/BajaJ/ Usha (Sample to be got approved), incl. cost of ceiling rose and making of space in walls/ windows as per site and necessary connections. 8 Supply and fixing of modular blanking plates on modular switch plates, excluding cost of switch plates 9 Wiring for ircuits/ sub mains along with earth wire in FRLS PVC Insulated 650/1100volt grade flexible stranded copper conductor wires of Polycab/ Havells/Anchor/ Finolex make in recessed or surface conduiting system, excluding cost of conduits 10 2 x 2.5 sq.mm + 1 x 2.5 sq. mm for inverter / solar sub main 11 2 x 4 sq. mm + 1 x 4 sq. mm for normal sub main 12 2 x 6 sq. mm + 1 x 6 sq. mm for heating sub main 13 Supply and fixing of 25 mm dia. Medium grade PVC conduit including its allied accessories like bends and concealed deeps, etc. for laying of wires, recessed In RCC stab / walls including refacing of walls or fixed with necessary clips and rowel plugs complete. 14 Supply and fixing of fan deep made of heavy gauge sheet in RCC slabs 15 Supply and fixing of 12 way Double door surface/ recess mounting, 240 V, SP&N MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer, 16 Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA C curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. 17 Supply, installation, testing and commissioning of 32A DP rating 240/415V, 10 КА С curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. 18 Supply, installation, testing and commissioning of 63A DP rating 240/415V, 10 ΚΑ C curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. 19 Supply and foxing of single pole blanking plates on existing MCB distribution boards. 20 Supply, laying, connecting and commissioning of 25 sq. mm 2 core PVC insulated flat Aluminum un armored LT cable for service line, incl. cost of required al. thimbles/lugs duly crimped. (Over head).