Tender For Provision Of Lift In Cgom Building At Bhubaneswar Under Ge (I) (Cg) Bhubaneswar; 1 SCH A PART-IM&L for Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed. 2 Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified an directed. 3 M&L Granite 18-20mm thick (of any Colour any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incluiding rendering 15mm thick in CM 1:4 complete all as specified and directed. 4 M&L for complete removal of existing treatment on walls andapplying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth and one coat of alkali resisting priming paint andtwo coat of oil bound distemper on walls etc complete all as specified and directed. 5 Dismantling floor, hearth orwall tiling including cementmortar bedding (but notbacking), removing serviceabletiles to store and rubbish off the premises complete all as specified and directed. 6 M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tilesnot exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with existing shade including 15mm thick screed bed in CM 1:4 complete all as specified and directed. 7 M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with existing shade including 10mm thick rendering in CM 1:4 complete all as specified and directed. 8 M&L for mild steel Joist, channel, angle, or tee sections,of Grade Fe 410 -W (Gde E- 250)quality-A fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed. 9 M&L preparation of new steel surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 10 Providing, cement concrete Type B0 1:2:4 (using 12.5mm Graded Aggregate) in bed platesand the like including weathering, slightly roundedor chamfered angles and throating, Complete all as specified and directed 11 Demolition ofConcrete (unreinforced) in any description and pavings n exc 15 cm thickness (below or above ground level complete all as specified and directed. 12 M&L for 100mm thick PCC 1:4:8 type D2 (40mm graded aggregate)as in Sub Base complete all as specified and directed 13 M&L for Machine pressed precast concrete interlocking paverblock any shape and size with grey cement and pigment confirming to IS 15658-2006of 60 mm thickness, M-35Grade including 50 mm thick sand filling complete all as specified and directed. 14 Demolition ofCement Concrete (reinforcement cut as required to facilitate demolition) for lift shaft/Roofs,floors(otherthan ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. (Note:- For demolition/Cutting of concerte and Reinforcement is to be done only by using mechanical cutter ) 15 M&LRCC M-30 DESIGN MIX (20mm graded crushed stone aggregate) Walls, Lift well/walls retaining walls, basement walls, ballast walls, and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. 16 M&L10mm dia & over CRS TMT Bars cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 17 M&LFor Formwork to faces of walls, retaining walls, abutments, parapets andsimilar work including attached pillasters, buttresses, etc.; vertical or to batter fair finished surfaces complete all as specified and directed. 18 M & L for Rendering 10 mm thick in CM 1:6 onon fair faces of brick/concrete wall surfaces of any description and finishing surfaces even and smooth with out using extra cement complete all as specified and directed. 19 M&L preparation of newly plastered surfaces & applying three coat of white wash on internal walls complete all as specified and directed. 20 M&L preparation of old treated surface and applying two coat of white wash on internal wall (Lift well) complete all as specified and directed. 21 M&L preparation of old treated surface and applying two coat of white wash on ceiling complete all as specified and directed. 22 Supply, install testing and commissioning of electrically operated passenger lift of capacity 8passenger lift (544 Kg) in the existing lift well, of size 2.1 mtr x 2.1 mtr (LxW) 1.5 m/s speed with automatic GIEN micro stroke button control microprocessor based controller, simplex selective/collective control suitable for 3 phases 50 Hz 415 volts of Variable voltage variable frequency (VVVF) driving system full collective contoland car size of 1375mm (W) x 1400 mm (D) x 2139 mm (H) ,with suitable motor and gear unit to serve four floorsi.e. with 04 stops and 4 landings(Travel/rise 21 M approx) with or without attendant suitable for syncronised operation automatic power operated centre opening with fully automatic landing doors with 2 hours fire rated landing doors, self diagnostic control andstainless steel hairline finish at centre opening directionwith infra red sensors all along the higher for car door with automatic evacuation to nearest floor (ARD) including light curtain on car entrancedigital indicators in car and all landing with call indicating lights including LCD displayetc complete all as specified and directed. The lift shall be provided with and including the following :- Note : The following items are deemed to be included in the quoted rate. 23 (a)Fire man switch(b)Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load.(c)Battery operated emergency light (LED ceiling fitting) alarm (speaker for emergency alarm system to be fixed) .(d)Two sleek circular LED light fitting in false ceiling.(e)One sleek circular PVC heavy duty fan in false ceiling make for © and (d) Philips/Bajaj/Havells/Crompton Greaves.(f)Granite flooring finish in black sea .(g) Non stop button/independent operation(h) Over load warning indicator audio & visual type(j)Landing door should be fully automatic landingwith stainless steel hairline finish(k) Car wall finish in stainless steel hairline(l)Car door finish in stainless steel hairline(m)Deco ceiling finish in stainless steel hairline (n)Handrail in stainless steel finish on rear wall(o)Full height mirror on rear car panel(p)Car opening panel should be stylish, touch, sensitive glass panel(q)Door open alarm buttons(r)Visual call confirmation(s)Car posistion indicator.(t)Pre-annoncing arrows for collective controls and 16 segment display(u)Close loop control system and self diagnostic control(v)Overload detection and autmoatic evacuation to nearest floor (ARD)(w)Auto fan off and auto light off system(x)CCTV Cable & intercom - 3 way and voice synthesizer on car 24 M&L for point wiring with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in and including PVC conduit heavy duty with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thickswitch board and brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessarywall cutting and making good disturbed surface complete all as specified and directed. 25 All as per item No. 23 above but one 3 pin socket outlet 5 Amps on same board. 26 Supply and fixingof modular switch one way 6 Amps 1 Module complete all as specified and directed. 27 Supply & fixing modularsocket outlet2 /3 pin 6 Amps 2 modules complete all as specified and directed. 28 Supply and fixing white modular cover plate with frame including metal flush box 1 Module complete all as specified and directed. 29 Supply and fixingwhite modular cover plate with frameincluding metal flush box 4 Module complete all as specified and directed. 30 S&FMCB DB made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and din rail of SPN 8 way, 240 Volts double door fixed in wall , making good disturbed surfaces,complete all as specified and directed. 31 Supply and fixing amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of single pole and Neutral (SPN) and current carrying capacity 40 to 63 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 32 Supply and fixing amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 33 Supply and fixing LED lights fitting 1x 16W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 34 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core complete all as specified and directed. 35 Excavation in trenches n.exc 1.5m wide and n. exc 1.5m depth getting out of soil for taking out or laying of pipe line etc complete all as specified and directedfor laying of cable, errection of poles, stay andpipe linein soft/loose soil complete all as specified and directed. 36 Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed. 37 Removal of surplus soil to a distance n. exc 50 m above the starting point complete all as specified and directed. 38 M&L for laying of bricks locally available sub class B bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed. 39 M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable complete all as specified and directed. Note : Punned thickness shall be measured for payment purpose. 40 M & L For Earthing complete with GI earth plates electrode 600x600x6mm thick burried directly in ground earth pit not less than2.25 mtr deep below ground level with top edge of earth plate not less than 1.5m below GL the plate surrounded with adequate quantity of charcoal dust mixed with salts to a packet thickness of 15 cm all around the plate,using GI earth strip 25x4 mm connected to earth plate by means of nut ,bolts and washersGI pipe light grade 32 mm bore for protection of strips from edge of earth plate to transformer plinth including water pipe of size light grade 32 mmfrom earth chamber toedge of earth plate,CI funnel with wiremesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pitcover 50mm thick pre-cost RCC 1:2:4 type B-1 dully rainforced with MS bars 6mm dia @100 cc both ways with 10mm dia MS bar in lifting handle excavation earth work etc all as directed in electrical plateNo 3 ofSSR pt I complete all asspecified and directed. 41 M&L for MCCB 3 Pole .415 V. fixed type,100 Amps with breaking capacity 16 KA in existing LT panel complete all as specified and directed. 42 S&FGI strip 25 mm x 4 mm complete laid in trenches / ducts fixed on steel structure (in extn of earthings) complete all as specified and directed. 43 Supply & fixingtesting and commissioning CPRI approved LT panel board out door type factory made duly finished, double door, cubical type floor mounted of suitablesize , Made out from 3.15 mm thick CRCA sheet powder coatedmounted on angle iron frame(50mmx50mmx6 mm thick) from structure , three phase 440 volts with suitable high conductivity epoxy painted aluminium bus bars- 04 Nos.mounted on porcelain insulators, drill for out going connection, prewired using suitable size of copper wire, using proper lugs / thimbles including din rail for fixing of MCCBs/MCBs, cable glandsof suitable sizesfor incoming and outgoing cables complete all as specified and directed. including the necessary PCC work andwith and including following :- 44 (a) MCCB100 Amp,36 KA,4 Pole-01 No(Incomer from Existing Panel) (b) MCCB40 Amp,16KA,4 Pole-03 No(Outgoing for 2 Nos of new lift & one spare) (c) MCB SPN 32 amps-01 No.(d) LED indicator lamp set of3(e)Voltmeter digital type with of (0-440) Volt(f ) Ammeter digital type with of (0-100) A 45 SCH A PART-II (COMPREHENSIVE MAINTENANCE OF LIFT)Comprehensive Maintenance , servicing and repairs including renewal/replacement of defective parts incluidng Auto Rescue Device(ARD) of electrically operated08 passengers lift after 2 year DLP. Suitable ground plus Five upper floors (G+3) i.e. with 04 stops and 04 landings with AC ,VVVF drive with selective control systemfloors,speed 1.5m/s and Automatically operated door system.Note : AMC of the lift during DLP period(i.e 2 years after completion of Phase-I work) shall be responsibility of the contractor and rate quoted by the contractor shall be deemed to included for this aspect.Noting shall be paid extra on this account. 46 AMC on 1st year after expiry of defect liability period (For 01 lift ) 47 AMC on 2nd year after expiry of defect liability period(For 01 lift ) 48 AMC on 3rd year after expiry of defect liability period(For 01 lift ) 49 Note :- (i) The rate quoted are demmed to include all/any charges related to renwal of lift licence and lift insurence from State Govt/other agency.(ii) The rate is inclusive of all items as required at site including any spares to keep the lift operational all the time (iii) Maintenance of the lifts should be donethrough the OEM(iv)The contractor should attend the complaint/breakdown immediately.(v) Maintenance of the lifts should be done as per manufactruer instrutions