}

Tender For Misc. Different Breakdown Works For Unit 8 , 9 And Bop Area Except Coal Handling Power Plant 2X250mw, Dtps, Htps Kasimpur, Aligarh - Supply & Misc Electrical Work . 2 Supply, Transportation, Proper Laying & Fixing Of 20Mm Size Frls Pvc Condui, kasimpur-Uttar Pradesh

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited has published Tender For Misc. Different Breakdown Works For Unit 8 , 9 And Bop Area Except Coal Handling Power Plant 2X250mw, Dtps, Htps Kasimpur, Aligarh - Supply & Misc Electrical Work . 2 Supply, Transportation, Proper Laying & Fixing Of 20Mm Size Frls Pvc Condui. Submission Date for this Tender is 11-08-2025. Coal Handling Plant Tenders in kasimpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50288623
Tender For Misc. Different Breakdown Works For Unit 8 , 9 And Bop Area Except Coal Handling Power Plant 2X250mw, Dtps, Htps Kasimpur, Aligarh - Supply & Misc Electrical Work . 2 Supply, Transportation, Proper Laying & Fixing Of 20Mm Size Frls Pvc Condui
Tender
Indian
Uttar Pradesh
Kasimpur
11-08-2025

Tender Documents

Tender Details

Tender For Misc. Different Breakdown Works For Unit 8 , 9 And Bop Area Except Coal Handling Power Plant 2X250mw, Dtps, Htps Kasimpur, Aligarh - Supply & Misc Electrical work . 2 Supply, Transportation, Proper Laying & fixing of 20mm size FRLS PVC Conduit on Wall/Column/Structure. 3 Supply, Proper Laying, jointing & fixing of 16/20 mm Size or different PVC Size flexible Conduit. 4 Supply , Proper Laying & fixing of 2 Core 4 mm Copper Cable. 5 Supply & fixing ofTG Hall EOT Crane Bus bar Supporting Insulators / 0.4 KV MCC Switchgear. 6 Fabrication, fixing of lighting Pole & other Canopy Work. 7 Fixing of lighting pole by drilling on Concrete foundationat Cooling Tower/ESP Roof Unit 8&9. 8 Formation concrete plinth around the lightingPoleat Cooling Tower U 8&9for its strengthen. 9 Supply, Fabrication & installation of canopy/ shed on ESP Transformer of Unit#8&9 of with size 4200mm x 4200mm x 4200mm. 10 Fabrication & installation of canopy/shed on out door uncovered motors of Unit#8&9size1500mm x 1250mm x 1250mm. 11 Fabrication & installation of canopy/shed on Cooling tower motor of Unit#8&9size 1500mm x 1250mm x 1250mm. 12 Replacement of existing Motor Terminal Box with new fabricated Box of running LT Motors range from 90KW to 200KW. 13 Installation & Fixing of Bus bar assembly Box &125 Amp MCB on wall of Boiler , Mill area & Turbine hall etc. 14 Complete Rectifiction of damaged /burnt different rating Modules & Supply andreplacement of all damaged Interal Parts . 15 Complete Rectifiction of damaged /burnt 180/200 KW Modules & replacement all Interal Parts( including Supporting Copper Busbar assembly,Power Wires, Insulation Sheets, Add on block, TB, Indicating LED Lamps, Metres, Fans ). 16 Complete Rectifiction of damaged /burnt 110/125/132 KW Modules & replacement all Interal Part ( Including Supporting Copper Busbar assembly,Power Wires, Insulation Sheets, Add on block, TB, Indicating LED Lamps, Metres, Fans ). 17 Complete Rectifictionof damaged /burnt 60/75/90 KW Modules & replacement all Interal Part ( Including Supporting Copper Busbar assembly,Power Wires, Insulation Sheets, Add on block, TB, Indicating LED Lamps, Metres, Fans ). 18 Complete Rectifiction of damaged /burnt 30/37/45 KW Modules & replacement all Interal Part ( Including Supporting Copper Busbar assembly,Power Wires, Insulation Sheets, Add on block, TB, Indicating LED Lamps, Metres, Fans ). 19 Supply,Installation & Commissioning of Motor Protection Relay in diffenent KW Modules rating (22KW to 200 KW). 20 Supply & Replacement of damaged /Cracked different Type Insulators of ESP & other Parts. 21 Supply & Replacement of damaged /Cracked Pin Insulator for HVR rating 105KVA RatingHV 53KV/LV 373.5V ,Current rating1.96 Amp/ LV side 281Amp, DC Output peak 70KV. 22 Supply & Replacement of damaged /Cracked Wall Bushing Insulator for HVR rating 105KVA RatingHV 53KV/LV 373.5V ,Current rating1.96 Amp/ LV side 281Amp, DC Output peak 70KV. 23 Supply & Replacement of damaged /Burnt Disconnecting Assembly for HVR rating 105KVA RatingHV 53KV/LV 373.5V ,Current rating1.96 Amp/ LV side 281Amp, DC Output peak 70KV. 24 Supply & Replacement of damaged /Burnt Connecting Tube from Bushing Insulator to Electrode for HVR rating 105KVA RatingHV 53KV/LV 373.5V ,Current rating1.96 Amp/ LV side 281Amp, DC Output peak 70KV. 25 Supply & Replacement of damaged Silica gel Pot with Silica gel for HVR rating 105KVA RatingHV 53KV/LV 373.5V ,Current rating1.96 Amp/ LV side 281Amp, DC Output peak 70KV.

Key Value

Document Fees
INR 3540 /-
EMD
INR 38500.0 /-
Tender Value
INR 38.54 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail