}

Tender For Miscellaneous Electrical Maintenance Work Under Chanderlok Building Wiring Enquiry Bm-I(E) Division., New Delhi-Delhi

New Delhi Municipal Council has published Tender For Miscellaneous Electrical Maintenance Work Under Chanderlok Building Wiring Enquiry Bm-I(E) Division.. Submission Date for this Tender is 29-07-2025. Electrical Maintenance Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

50280465
Tender For Miscellaneous Electrical Maintenance Work Under Chanderlok Building Wiring Enquiry Bm-I(E) Division.
Tender
Indian
Delhi
New Delhi
29-07-2025

Tender Documents

Tender Details

Tender For Miscellaneous Electrical maintenance work under Chanderlok Building wiring enquiry BM-I(E) division.- 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group – C 2 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 3 Wiring for circuit/ sub-main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 4 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required 5 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 6 Supplying and fixing of following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V on surface /recess, complete with tinned copper bus bar, neutral bas bar earth bar din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4+24), Double Door 7 4 way (4+12), Double Door 8 Supplying and fixing following way, single pole and neutral, sheet, steel, MCB distribution board, 240V on surface / recess, complete with tinned copper bus bar, neutral bus bar earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator) 6 way Double Door 9 Wiring for circuit /sub-main along with earth wire with the following size of FRLS PVC insulted copper conductor single core cable in surface / recessed medium class PVC conduit as required. 2x10 sq. mm. + 1x6 sq. mm. earth wire 10 Supplying and fixing 5A to 32 Amp. Rating, 240/415V 10kA “C’” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole 11 Supplying and fixing following rating, double pole 240V isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A 12 63 A 13 Supplying and fixing following rating, double pole 415 V isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A 14 Supplying and fixing following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 15 Providing & fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubicle panel making connections etc as required .200A 36 KA FP MCCB 16 Supplying, installation, Testing & Commissioning of LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt )LED Recessed /surface Down lighter (Round / square/ Rectangular) following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K /4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector 22watt Make: Phillips/Havells/Crompton/Wipro 17 Supplying and fixing of cubical type panel board fabricated from 16 SWG CRCA sheet, duly powder coated, of approximate size 500 mm x 500 mm x 200 mm deep, suitable for wall mounting, complete with one number 250 Amp, 4 Pole, 415 Volt, 36 kA breaking capacity MCCB, enclosed in a separate chamber. The panel shall include a bus-bar chamber with 4 Nos. copper bus-bars of size 25 mm x 10 mm, each rated for 250 Amp, properly insulated and mounted. It shall also be provided with one set of ammeter and voltmeter, each with a selector switch, RYB phase indicating LED lights, and internal wiring using 16 sq.mm copper conductor wires with necessary thimbles, lugs, and ferrules. The panel shall include provision for installation of existing 3-phase energy meter, along with a proper enclosure and neutral link. The panel shall be provided with ventilation louvers, a handle for door operation, 65 mm locking arrangement, and a danger plate as per IS standards. It shall be grouted/fixed to the wall with necessary supports, including all associated masonry repair, whitewashing, earthing, testing, and commissioning, complete in all respects as required at site. 18 S&F of Cubical board made out of CRCA sheet 16 SWG, powder coated of suitable size 300 x 400 x 150 mm deep (nominal)suitable for supply and installation of MCCB 125amps 36KA breaking capacity, 4 pole, 415Volt, copper bus-bar chamber having 4 Nos, 125 amps capacity, copper bus bar of size 25mm x 5mm, one set of Amp and Volt meter with selector switch RYB indicating lights including wiring with 16sq. mm copper wire, thimbles, nut bolts along with grouting in the wall including connection testing, commissioning, painting and providing locking arrangement along with lock 65 mm size, provision for ventilating air fins, handle for opening of door, fixing of danger plate, including masonry/white washing work etc. complete as required at site. 19 Dismantling of old material including old PLL fittings, Panel , DB Box as iron scrapetc. complete as required at site then deposit the same to the enquiry of JEE (BM-I) at Chanderlok Building 20 Credit for retaining the old PLL fittings, Panel , DB Box as iron scrap

Key Value

Document Fees
Refer document
EMD
INR 19594.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail