Tender For Provn Of Otm Accn In Alhilal; 1 Lumpsum price worked out by the contractor for Building and Structures as listed in Schedule A Part-I. 2 Lumpsum price worked out by the contractor for earth work, site clearance and site development as listed in Schedule A Part-II. 3 Lumpsum price worked out by the contractor for Internal water Supply Works as listed in Schedule A Part-III. 4 Lumpsum price worked out by the contractor for Internal Electrification as listed in Schedule A Part-IV. 5 Lumpsum price worked out by the contractor for Plumbing work Works as listed in Schedule A Part-V. 6 Lumpsum price worked out by the contractor for Protective Works as listed in Schedule A Part-VI. 7 Lumpsum price worked out by the contractor for Road, Path & Culverts Worksas listed in Schedule A Part-VII. 8 Lumpsum price worked out by the contractor for Sewage Dipsosal Works as listed in Schedule A Part-VIII. 9 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule A Part-IX. 10 Lumpsum price worked out by the contractor for External water supply as listed in Schedule A Part-X. 11 Lumpsum price worked out by the contractor for External Electrification as listed in Schedule A Part-XI. 12 Lumpsum price worked out by the contractor forCompound wall and steel gate as listed in Schedule A Part-XII. 13 Lumpsum price worked out by the contractor forConnecting Passage as listed in Schedule A Part-XIII. 14 Lumpsum price worked out by the contractor forLightening Protection as listed in Schedule A Part-XIV. 15 Lumpsum price worked out by the contractor forHot Water Apparatus as listed in Schedule A Part-XV. 16 Lumpsum price worked out by the contractor forDemolition and Dismantling Works as listed in Schedule A Part-XVI. 17 Schedule A Part-VII : Schedule of Credit 18 Schedule A Part-VIIII : Miscellaneous Items (to be quoted by the bidder) 19 INTERNAL ELECTRIFICATION : 20 Supply and fixing Led luminaire 600 mm x 600 mm, 35/36 watt LED 4000 k, 220 V AC surface mounted type with high efficiency having efficacy 120 lumens / watt, power factor more than 0.90, IP 20 soft glare free light complete with driver, holders etc including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed. 21 Supply and fixing round shape 12 watt, 220 volts, AC, 50 Hz suurface type with efficiency having efficacy 120 lumens / watt, power factor more than 0.90, IP 20 soft glare free light complete with drivers, holders LED lamp suitable for ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 22 S & F High performance IP66 streetlight 20 watt, housing made of die –cast aluminum, with street optic lens, with all accessories and connecting up with all including provision of 3 core flexible copper wire of size 1.5 sqmm from ceiling rose, and 20 W LED light etc drawn through and including 32mm bore GI light grade protection pipe upto 1.0m length with suitable fixing accessories on walls, complete all as specified and as directed. 23 Supply and fixing LED luminaire 1 feet, 20 watt LED 4000 k, 220 V AC Recess mounted type with high efficiency having efficacy 120 lumens / watt, extruded aluminium with a satin finish PMMA diffuser, for stand alone and seamless end-to-end connectivity having power factor more than 0.90, IP 20 soft glare free light complete including connecting up with copper conductor cable of suitable size complete all as specified and as directed. 24 Supply and fixing decorative wall light made out of polycarbonate suitable for 12 watt LED lamp complete all as specified and directed. (Price of LED lamp included in quoted rate). 25 Supply and fixing Auto clean curved glass kitchen chimney 90 cm 1500 cum / hrs suction power, wall mounted filter surface area 78 x 30 sqcm, Max noise db 58, inbuild 1.5 watt LED lamp 2 numbers (Hood primus plus energy HC SC KK 90, baffle filter, Touch control, Black in colour) including stranded installation with duction kit and duck pipe complete all as specified and as directed. 26 Supply and fixing VTPN Loadline DBs as per IEC 61439-3, with 250 Amps copper bus bar, 2 neutral bar, 2 earth bar, fully insulated bus bar, balnking plates (without MCBs and MCCBs) Double door 4-way suitable for upto 160 Amps MCCB incomer, IP 43 protection 415 Vols, AC, 50 Hz complete all as specified and directed. 27 Supply and fixing of telephone socket is Robust designed assembly plates smug fit on the wall with assembly plates with suitable modules, white in color, dust free glossy finish complete all as specified and as directed. 28 S & F blanking plate for MCB DBs complete all as specified and directed. 29 M & L for earthing complete with G.I earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected galvanized iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 M, including PCC chamber in PCC (1:2:4), type B1, using (20 mm graded stone aggregate) mild steel frame made out of angle iron od size 40 mm x 40 mm x 6mmthick duly painted with two coats of synthetic enamel paint over one red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangements with funnel internally secured with wire mesh with 20 mm dia light grade GI pipe for watering, 15 mm dia medium grade, GI pipe for earth pipe for earth wire protection with and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 connected to DBs all as specified and indicated including testing on completion. 30 EXTERNAL ELECTRIFICATION : 31 Supply, installing, commissioning & testing transformer suitable for 250 KVA (Level-2) step down floor mounted outdoor type 11/.433, 3 phase, 50 Hz AC, IS: 1180-2014 ISI marked, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 (vector group 4) with neutral brought out on LV side with for earthing and having tapping on HV side for constant output so as to alter/vary secondary voltage by(Tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories. The limit of temperature rise after continuous full load run as specified in IS-1180 (Part-I) 2014 and BEE Certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 32 (i) Oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (ii)Silica gel breather with connecting pipe, first fill of dehydrating agent. (iii)Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (iv) Air release valve plug (v) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints (vi)Explosive vent (vii) 01 No 100 mm dial type thermometer vapour pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc.(viii) Thermometer pocket on tank cover (ix) 04 Nos plain solid CI datachable rollers(x) Two Nos Earthing terminals marking plate.(xi) Rating plate and terminal marking plate (xii) Extra bushing for neutral outside the cable box brought out on LV side. (xiii) First filling of oil conforming to IS and tested upto 60 KV dielectric strenght (xiv) Lifting lugs (xv) Oil drain valve with plug(xvi) One cable box on HV side (Primary) consisting of 01 cable gland suitable for reception of taking in HT cable including gland joints (xvii) Hand hole of sufficient size to assess interior of tank(xviii) Dehydrating breather with first filling of Dehydrating agent (xix) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strip. (xx) Rating plate with terminal marking plate (xxi) Inspection cover. 33 Note :- (a) Transformer shall be Pre-Commisioned by SEI after installation.(b) Cost of all necessary T&P and measuring devices shall be provided by the contractor without any extra cost. (c) Drawing of transformer shall be approved by GE before placing the order. (d) Pre-dispatch inspection at factory premises shall be carried out by rep of Accepting Officer. Contractor shall intimate the planned date of inspection well in advance. All incidental expenditure for getting the inspection/testing in the factory premises shall be borne by the contractor including transportation and administration arrangement for the rep of accepting officer without any extra cost to the department. (e) PCC foundation, plateform as per TD drg without any extra cost. 34 Material and labour for cable route indicator post of size 900x300x100mm made of precast cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate, rounded tops as directed and embeded in ground (450mm below ground and 450mm above ground level) with PCC (1:3:6) type C-1, using 20 mm graded stone aggregate block of size 350x150x450mm, including 5 mm thick plastering all round of exposed surface of post above ground with CM (1:4) and finished even and smooth without using extra cement, applying two coats of cement base paint on plastered surface including writing letters (like HT UG cable, __ feeder etc.) with synthetic enamel paint in brown colour in suitable size including earth work and form work complete all as specified and as directed. 35 Supply and fixing energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection with suitable size of wire from junction box to street light fitting, fixing the light fitting with and including bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications,complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) CRI: Morethan 70 and CCT : 5700 K.(g) IP rating : IP65. (h) IK rating:Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire.(k) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) 36 Supply and fixing of Hot press Moulded SMC (Sheet Moulding Compound) junction box of inside dimention 240 x 130 x 110mm including 4 Nos Aluminium Stud terminal of suitable size and one Nos MCB SP 6 Amps and fixed on pole with clamps. bolts and nuts / grouted in coping of pole complete with two coat of synethictic enamel paint powder coated as provided by manufacturermake complete all as specified and as directed. 37 Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type outer shell made out of3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level,frame factory fabricated with front and backopenable double door systemlockable/openable by Keyshaving chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricatedhaving modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing,phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The Four Pole busbar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size F class insulator at an interval not more than 250 mm through out the length of the Four Pole busbar.The cubical incomer MCCB as well as outgoing shall have aluminium Four Pole extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size F class insulator complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- 38 Four Pole, Aluminium bus bar 1200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators 39 MCCB 500 Amp, FP50 Hz, 415 V, 36KA, adjustable type – 01 Nos (Incoming) 40 MCCB 200 Amp, FP50 Hz, 415 V, 36KA, adjustable type – 01 Nos (Out going) 41 MCCB 160 Amp, FP50 Hz, 415 V, 25KA, adjustable type – 01 Nos (Out going) 42 MCCB 100 Amp, FP50 Hz, 415 V, 25KA, adjustable type – 02 No (Out going) 43 Multifunction Meter Digital type showing Volt, Amp, Frequency, power factor,KW, KWh in built selector switch with suitable CT coils for three phase - 01 No 44 LED Indicated Lamp (R,Y,B) one Set-01 45 Internal power and control wiring with suitable size PVC insulated multistranded copper wire. 46 Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication. 47 Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type outer shell made out of3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level,frame factory fabricated with front and backopenable double door systemlockable/openable by Keyshaving chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricatedhaving modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing,phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The Four Pole busbar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size F class insulator at an interval not more than 250 mm through out the length of the Four Pole busbar.The cubical incomer MCCB as well as outgoing shall have aluminium Four Pole extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size F class insulator complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- 48 Four Pole, Aluminium bus bar 160 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators 49 MCCB 100 Amp, FP50 Hz, 415 V, 25KA, adjustable type – 01 No (Incoming) 50 MCCB 63 Amp, FP50 Hz, 415 V, 25KA, adjustable type – 01 No (Out going) 51 MCCB 32 Amp,FP50 Hz, 415 V, 25KA, adjustable type – 02 Nos (Out going) 52 MCB 32 Amp, DP50 Hz, 240 V, 10KA – 02 Nos (Out going) 53 MCB 16 Amp, DP50 Hz, 240 V, 10KA – 02 Nos (Out going) 54 Timer switch light sensing typewith outer sensor having current capacity 16A & control from 1 lux to 100K lux , 230 Volts, 50 HZ and 2 pole power contactor 16 Amps capacity single phase, 230 Volts 50 HZsuitable for 1 phase distribution -01 Each. 55 Multifunction Meter Digital type showing Volt, Amp, Frequency, power factor,KW, KWh in built selector switch with suitable CT coils for three phase - 01 No 56 LED Indicated Lamp (R,Y,B) one Set-01 57 Internal power and control wiring with suitable size PVC insulated multistranded copper wire. 58 Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication. 59 Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type outer shell made out of3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level,frame factory fabricated with front and backopenable double door systemlockable/openable by Keyshaving chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricatedhaving modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing,phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The Four Pole busbar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size F class insulator at an interval not more than 250 mm through out the length of the Four Pole busbar.The cubical incomer MCCB as well as outgoing shall have aluminium Four Pole extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size F class insulator complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- 60 Four Pole, Aluminium bus bar 250 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators 61 MCCB 160 Amp, FP50 Hz, 415 V, 25KA, adjustable type – 01 No (Incoming) 62 MCCB 63 Amp, FP50 Hz, 415 V, 25KA, adjustable type – 02 No (Out going) 63 MCB 32 Amp, DP50 Hz, 240 V, 10KA – 02 Nos (Out going) 64 MCB 16 Amp, DP50 Hz, 240 V, 10KA – 01 Nos (Out going for S/light) 65 Timer switch light sensing typewith outer sensor having current capacity 16A & control from 1 lux to 100K lux , 230 Volts, 50 HZ and 2 pole power contactor 16 Amps capacity single phase, 230 Volts 50 HZsuitable for 1 phase distribution -01 Each. 66 Multifunction Meter Digital type showing Volt, Amp, Frequency, power factor,KW, KWh in built selector switch with suitable CT coils for three phase - 01 No 67 LED Indicated Lamp (R,Y,B) one Set-01 68 Internal power and control wiring with suitable size PVC insulated multistranded copper wire. 69 Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication. 70 Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type outer shell made out of3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level,frame factory fabricated with front and backopenable double door systemlockable/openable by Keyshaving chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricatedhaving modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing,phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The Four Pole busbar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size F class insulator at an interval not more than 250 mm through out the length of the Four Pole busbar.The cubical incomer MCCB as well as outgoing shall have aluminium Four Pole extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size F class insulator complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- 71 Four Pole, Aluminium bus bar 160 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators 72 MCCB 100 Amp, FP50 Hz, 415 V, 25KA, adjustable type – 01 No (Incoming) 73 MCCB 63 Amp, FP50 Hz, 415 V, 25KA, adjustable type – 01 No (Out going) 74 MCCB 40 Amp,FP50 Hz, 415 V, 25KA, adjustable type – 01 Nos (Out going) 75 MCB 32 Amp, DP50 Hz, 240 V, 10KA – 02 Nos (Out going) 76 MCB 16 Amp, DP50 Hz, 240 V, 10KA – 02 Nos (Out going) 77 Timer switch light sensing typewith outer sensor having current capacity 16A & control from 1 lux to 100K lux , 230 Volts, 50 HZ and 2 pole power contactor 16 Amps capacity single phase, 230 Volts 50 HZsuitable for 1 phase distribution -01 Each. 78 Multifunction Meter Digital type showing Volt, Amp, Frequency, power factor,KW, KWh in built selector switch with suitable CT coils for three phase - 01 No 79 LED Indicated Lamp (R,Y,B) one Set-01 80 Internal power and control wiring with suitable size PVC insulated multistranded copper wire. 81 Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate.(ii) Drawing of panel shall be approved by GE before fabrication. 82 Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type outer shell made out of3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level,frame factory fabricated with front and backopenable double door systemlockable/openable by Keyshaving chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricatedhaving modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing,phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The Four Pole busbar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size F class insulator at an interval not more than 250 mm through out the length of the Four Pole busbar.The cubical incomer MCCB as well as outgoing shall have aluminium Four Pole extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size F class insulator complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- 83 Four Pole, Aluminium bus bar 250 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators 84 MCCB 160 Amp, FP50 Hz, 415 V, 25KA, adjustable type – 01 No (Incoming) 85 MCCB 63 Amp, FP50 Hz, 415 V, 25KA, adjustable type – 03 No (Out going) 86 MCB 32 Amp, DP50 Hz, 240 V, 10KA – 03 Nos (Out going) 87 MCB 16 Amp, DP50 Hz, 240 V, 10KA – 01 Nos (Out going) 88 Timer switch light sensing typewith outer sensor having current capacity 16A & control from 1 lux to 100K lux , 230 Volts, 50 HZ and 2 pole power contactor 16 Amps capacity single phase, 230 Volts 50 HZsuitable for 1 phase distribution -01 Each. 89 Multifunction Meter Digital type showing Volt, Amp, Frequency, power factor,KW, KWh in built selector switch with suitable CT coils for three phase - 01 No 90 LED Indicated Lamp (R,Y,B) one Set-01 91 Internal power and control wiring with suitable size PVC insulated multistranded copper wire. 92 Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication. 93 Supply, installation & testing of main distribution feeder pillar box cubical, indoor type, factory fabricated out of 2 mm thick CRCAsheet of size not less than 800mmx800mmx240mm, having inbuilt locking arrangement with 2 Nos lock and keys, rubber gasket packing, earthing arrangement, door handles, danger notice board, inside & outside painted with two coats of polyster powder coated, incl common alluminium busbar of 200 amps rating - 04 Nos. mounted on porcelain supports, suitably spaced & enclosed in chamber, cable entry holes, cable glands, copper wired of suitable size including lugs, fixing of main board on the wall with necessary civil work, DB should have sufficient space to accomodate incl neccessary civil/plastering work for making good the disturbed surfaces incl supply & fixing of following items complete :- 94 (i) MCCB 4 pole, 415 volts, 40 amp, 25 KA breaking capacity- 1No. (incoming) 95 (ii) MCB SPN 16 Amp, 230 V, 10 KA breaking capacity, C series - 4 Nos. (outgoing) 96 Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIearthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. 97 Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIearthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.(ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item.(iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. 98 EXTERNAL WATER SUPPLY 99 Supplying, laying, jointing and testing Ductileiron pipe (ISI marked) class K-7, bore 150 mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed.Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly.(ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate. 100 Supplying, laying, jointing and testing Ductileiron pipe (ISI marked) class K-7, bore 100 mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed.Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate. 101 Supply and fixing DI fitting upto 150 mm bore pipe line for reducing/bends (any type radius and angle) tapers any type, straight, bend, increasing decreasing or double socket extra Tee pieces single branch Y Junction double branch cross collers cap etc complete all as specified and as directed.Note:- Make of DI fittings shall be same make as DI pipe or as per recommendation of DI pipe manufacturer 102 Material and labour for Construction of brick masonary valve pit chamber size 90 X90 X90 cm (internal dimension) using sub class B bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed. 103 Material and labour for Construction of brick masonary valve pit chamber size 120 X120 X120 cm (internal dimension) using sub class B bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed. 104 Material and labour for Cutting ofexisting CI/DI pipes line 300 mm bore for inserting and including tee of size 150x100x100mm for taping in trenches including run lead joint complete all as specified and as directed.NOTE:- Necessary earth work, CI fitting/lead joints etc reqd to complete the job deemed to be included in the quoted rate. 105 SEWAGE DIPOSAL 106 DWCPE (SNB) 200 (OD)/175(ID) mm diameter pipes on laid in trenches and jointed complete all as specified and directed. 107 On Site LLDPE septic tank conventional type Designed To carry sewage and sullage water, including excavation in any type of soil, PCC 1:4:8 below foundation, Vent Shaft, connection Of 30 User etc.complete all as specified and directed. 108 On Site LLDPE septic tank conventional type Designed To carry sewage and sullage water, including excavation in any type of soil, PCC 1:4:8 below foundation, Vent Shaft, connection Of 10 User etc,complete all as specified and directed. 109 On Site Septic Tank(10.60 x 2.70M) Excavation over areas,Hard core 100 mm thk, 200mm thk PCC 1:2:4,Brick masonry in CM 1:4,rendering 1:4 for 150 users etc.complete all as specified and directed.(as per TD No.CEPZ-TD/013/13 DT 11 SEP 2013 SHT No 1/5 to 5/5) 110 Soakage Pit excavation over areas in any type of soil, complete filled with brick bats of size 3.0 m dia. x 3.75 m effective depth complete all as specified and directed.(as per TD No.CEPZ-TD/013/13 DT 11 SEP 2013 SHT No 1/5 to 5/5) 111 Soakage Wells excavation, in any type of soil, foundation in PCC 1:3:6, Walls of honey combed masonry with top ring of M-25 Concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.5 M dia X 4.5 M effective depth 112 ROAD PATH AND CULVERT 113 Providing and applying 2.5 mm thick retro-reflective road marking strips of specified shade/colour using hot thermoplastic material, applied by a fully or semi-automatic thermoplastic paint applicator machine fitted with a profile shoe heater, operated by an experienced operator on a prepared road surface. The work includes the cost of all materials, labour, tools and plant (T&P), and cleaning the road surface of all dust, debris, oil, grease, and foreign material, complete all as per the directions of the Engineer-in-Charge. 114 SUMMER APPLIANCES 115 Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz,of capacity 253 ltrs with BEE approved, minimum 3 star rating single door, stablizer free operation, DC Inverter Technology, R600a Refrigerant,LED display, tempered glass self,deodorizer and with fruit & vegetable drawer complete all as specified and as directed.Make :Sumsung, Model : RT28T3453 UT or equivalent Model of LG/Voltas/Bluestar/Hitachi/DaikainNote : Contractor shall submit original purhase voucher and Warranty card as remmended by manufacturer. Minimum warranty should be 1 years for complete product and 10 year for compressor after Installation and commissioining of complete units 116 Supply, installing, commissioning and testing of hard top deep freezer single phase 220V, 50Hz of 400 ltrs capacity having single door, direct cool evaporator type,refrigerant 134a, caster lock, Temp range<-18 ºC, Analogue temp setting, magnetic door gasket, caster wheel, inside alluminium cladding, outside body -PCM plastic material etc complete all as specified and as directed.Make : Blue Star, Model: CHFSD400DHSW or equivalent Model of Voltas / Godrej / LGNote : Contractor shall submit original purhase voucher and Warranty card as remmended by manufacturer. Minimum warranty should be 1 years for complete product and 10 year for compressor after Installation and commissioining of complete units. 117 Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA with wall mounting bracket complete all as specified and as directed.Make : V-Gaurd, Model- VG100 or Equivalent Model ol Sinetrac / AE. 118 HOT WATER APPARATUS 119 Supply, installing, commissioning and testing of Solar Water Heating system (Flat Plate Collector) based on indirect transfer of heat of capacity 1500 Ltrs Per Day having makeup tank capacity of 10 ltr including electric backup stainless steel hot water tank suitable for inlet water with chlorine and fluoride content up to 100 PPM and comprising of solar flat plate collector, collector stand assembly with collector A Size aluminium box collector comprising of following :- 120 ISI Marked (IS-12933 Part-I)-1992 with amendment NO 1 & 2 solar flat plate collector, having outer nominal diameter of 1860mm x 1240mm &110 mm material aluminium cast type channel and angle back covering 22 SWG aluminium sheet. Upper covering not less than 4 mm thick tempered/toughened glass absorber selectively coated copper fin and tubes, nominal fin size 0.2 mm thick x 1716 mm length, tube size 24 SWGX 1270mm ODX1721mm length, insulation 50 mm thick mineral wool of 48 gauge aluminium foil Gaskets EPDM/SPDM/Neoprene, Flanges 62 mm OD x 3 mm thick brass flanges header pipe 22 SWG X25.4 mm OD X 1320 length with following specification :- 2 Nos (i) Cover plate shall be toughened glass conforming to IS 12933 (Part-I) 1992 with amendment NO 1 & 2. (ii) Collector box shall be made of aluminium sheet, type Grade, Size and finish of material used shall be as per IS 12933 (Part-I) 1992 with amendment No 1 & 2. (iii) Sheet for abserver shall be made of copper type Grade, size and finish of material used shall be as per IS 12933 (Part-I) 1992 with amendment No 1 & 2.(iv)Collector box insulation shall confirm IS 12933 (Part-2, section V) 1992 with amendment No 1 & 2. (v)Gaskets and groutments shall confirm to IS 12933 (Part-2, section VI) 1992 with amendment No 1 & 2.(vi)Cold water Tank of 500 Ltr duly mounted on suitable size of platformIncluding necessary structure and finishing work, foundation. 121 Insulated stainless steel Hot water storage tank non pressure type made of stainless steel grade 04 Cr 18 NI or 07 Cr 18 NI of IS 1570 (Part-3)-1985, TIG Welded of 300 Ltrs capacity, non-magnetic tank with stainless steel fittings with following specification -01 No shall be insulated with 40 mm thermal grade PU insulation with FRP Cladding Tank stand assembly shall be made of Size 38 x38 x 4 mm duly pre-treated and stove enamelled with black colour paint. 122 Provisions of electrical back up with min 3 KW heating element - One Job Solar water heating system shall be provided on roof of single / double storey building.The electrical back up connection shall be tapped from sub main board provided at ground floor. 123 Heat exchanger shall be cage type and made of stainless steel tube of grade 04 Cr 18 NI or 0718 NI of IS 1570 (Part-2) 1885 124 Note:- (i) The system shall be tested on completion to ensure that 500 ltrs of water at 65 degree centigrade is available in hot water tank on a normal day in cold season. (ii) General Purpose rotational moulded PVC/Syntex overhead tank of capacity 500 ltrs for each system with inlet and outlet solar heat exchanger shall be provided at roof 3 M above roof level as catered for in building drawings. (iii)Normal water pipes and accessories from the normal overhead water tank to inlet of both make up water tank and plate collector shall be included in the quoted rates only.Similarly hot water pipes from hot water storage tank to bathrooms/ kitchen shall be measured and paid for separately 125 All other pipe /civil work, steel staging work for PVC tank, electrical work, outlet and inlet thermometer, air release valves, check valves, gate valves, controls and instruments etc.all as required shall be paid as under relevant iems seperately. Make : The complete solar water heating system shall be one of the following makes:SOLOHROME SYSTEM INDIA LTD (PARWANOO HIMACHAL) / SURYA JYOTI DEVICE INDIA LTD ( ROPAR PUNJAB) / INTER SOLAR. 126 Supply, installing, commissioning and testing of Solar Water Heating system (Flat Plate Collector) based on indirect transfer of heat of capacity 500 Ltrs Per Day having makeup tank capacity of 7 ltr including electric backup stainless steel hot water tank suitable for inlet water with chlorine and fluoride content up to 100 PPM and comprising of solar flat plate collector, collector stand assembly with collector A Size aluminium box collector comprising of following :- 127 ISI Marked (IS-12933 Part-I)-1992 with amendment NO 1 & 2 solar flat plate collector, having outer nominal diameter of 1860mm x 1240mm &110 mm material aluminium cast type channel and angle back covering 22 SWG aluminium sheet. Upper covering not less than 4 mm thick tempered/toughened glass absorber selectively coated copper fin and tubes, nominal fin size 0.2 mm thick x 1716 mm length, tube size 24 SWGX 1270mm ODX1721mm length, insulation 50 mm thick mineral wool of 48 gauge aluminium foil Gaskets EPDM/SPDM/Neoprene, Flanges 62 mm OD x 3 mm thick brass flanges header pipe 22 SWG X25.4 mm OD X 1320 length with following specification :- 2 Nos(i) Cover plate shall be toughened glass conforming to IS 12933 (Part-I) 1992 with amendment NO 1 & 2.(ii) Collector box shall be made of aluminium sheet, type Grade, Size and finish of material used shall be as per IS 12933 (Part-I) 1992 with amendment No 1 & 2. (iii) Sheet for abserver shall be made of copper type Grade, size and finish of material used shall be as per IS 12933 (Part-I) 1992 with amendment No 1 & 2.(iv)Collector box insulation shall confirm IS 12933 (Part-2, section V) 1992 with amendment No 1 & 2.(v)Gaskets and groutments shall confirm to IS 12933 (Part-2, section VI) 1992 with amendment No 1 & 2. 128 Insulated stainless steel Hot water storage tank non pressure type made of stainless steel grade 04 Cr 18 NI or 07 Cr 18 NI of IS 1570 (Part-3)-1985, TIG Welded of 300 Ltrs capacity, non-magnetic tank with stainless steel fittings with following specification -01 No shall be insulated with 40 mm thermal grade PU insulation with FRP Cladding Tank stand assembly shall be made of Size 38 x38 x 4 mm duly pre-treated and stove enamelled with black colour paint. 129 Provisions of electrical back up with min 3 KW heating element - One Job Solar water heating system shall be provided on roof of single / double storey building.The electrical back up connection shall be tapped from sub main board provided at ground floor. 130 Heat exchanger shall be cage type and made of stainless steel tube of grade 04 Cr 18 NI or 0718 NI of IS 1570 (Part-2) 1885 131 Note:- (i) The system shall be tested on completion to ensure that 500 ltrs of water at 65 degree centigrade is available in hot water tank on a normal day in cold season. (ii) General Purpose rotational moulded PVC/Syntex overhead tank of capacity 500 ltrs for each system with inlet and outlet solar heat exchanger shall be provided at roof 3 M above roof level as catered for in building drawings. (iii)Normal water pipes and accessories from the normal overhead water tank to inlet of both make up water tank and plate collector shall be included in the quoted rates only.Similarly hot water pipes from hot water storage tank to bathrooms/ kitchen shall be measured and paid for separately 132 All other pipe /civil work, steel staging work for PVC tank, electrical work, outlet and inlet thermometer, air release valves, check valves, gate valves, controls and instruments etc.all as required shall be paid as under relevant iems seperately. Make : The complete solar water heating system shall be one of the following makes:SOLOHROME SYSTEM INDIA LTD (PARWANOO HIMACHAL) / SURYA JYOTI DEVICE INDIA LTD ( ROPAR PUNJAB) / INTER SOLAR. 133 Supply, installing, commissioning and testing of Solar Water Heating system (Flat Plate Collector) based on indirect transfer of heat of capacity 200 Ltrs Per Day having makeup tank capacity of 5 ltr including electric backup stainless steel hot water tank suitable for inlet water with chlorine and fluoride content up to 100 PPM and comprising of solar flat plate collector, collector stand assembly with collector A Size aluminium box collector comprising of following :- 134 ISI Marked (IS-12933 Part-I)-1992 with amendment NO 1 & 2 solar flat plate collector, having outer nominal diameter of 1860mm x 1240mm &110 mm material aluminium cast type channel and angle back covering 22 SWG aluminium sheet. Upper covering not less than 4 mm thick tempered/toughened glass absorber selectively coated copper fin and tubes, nominal fin size 0.2 mm thick x 1716 mm length, tube size 24 SWGX 1270mm ODX1721mm length, insulation 50 mm thick mineral wool of 48 gauge aluminium foil Gaskets EPDM/SPDM/Neoprene, Flanges 62 mm OD x 3 mm thick brass flanges header pipe 22 SWG X25.4 mm OD X 1320 length with following specification :- 2 Nos(i) Cover plate shall be toughened glass conforming to IS 12933 (Part-I) 1992 with amendment NO 1 & 2.(ii) Collector box shall be made of aluminium sheet, type Grade, Size and finish of material used shall be as per IS 12933 (Part-I) 1992 with amendment No 1 & 2. (iii) Sheet for abserver shall be made of copper type Grade, size and finish of material used shall be as per IS 12933 (Part-I) 1992 with amendment No 1 & 2.(iv)Collector box insulation shall confirm IS 12933 (Part-2, section V) 1992 with amendment No 1 & 2.(v)Gaskets and groutments shall confirm to IS 12933 (Part-2, section VI) 1992 with amendment No 1 & 2. 135 Insulated stainless steel Hot water storage tank non pressure type made of stainless steel grade 04 Cr 18 NI or 07 Cr 18 NI of IS 1570 (Part-3)-1985, TIG Welded of 300 Ltrs capacity, non-magnetic tank with stainless steel fittings with following specification -01 No shall be insulated with 40 mm thermal grade PU insulation with FRP Cladding Tank stand assembly shall be made of Size 38 x38 x 4 mm duly pre-treated and stove enamelled with black colour paint. 136 Provisions of electrical back up with min 3 KW heating element - One Job Solar water heating system shall be provided on roof of single / double storey building.The electrical back up connection shall be tapped from sub main board provided at ground floor. 137 Heat exchanger shall be cage type and made of stainless steel tube of grade 04 Cr 18 NI or 0718 NI of IS 1570 (Part-2) 1885 138 Note:- (i) The system shall be tested on completion to ensure that 500 ltrs of water at 65 degree centigrade is available in hot water tank on a normal day in cold season. (ii) General Purpose rotational moulded PVC/Syntex overhead tank of capacity 500 ltrs for each system with inlet and outlet solar heat exchanger shall be provided at roof 3 M above roof level as catered for in building drawings. (iii)Normal water pipes and accessories from the normal overhead water tank to inlet of both make up water tank and plate collector shall be included in the quoted rates only.Similarly hot water pipes from hot water storage tank to bathrooms/ kitchen shall be measured and paid for separately 139 All other pipe /civil work, steel staging work for PVC tank, electrical work, outlet and inlet thermometer, air release valves, check valves, gate valves, controls and instruments etc.all as required shall be paid as under relevant iems seperately. Make : The complete solar water heating system shall be one of the following makes:SOLOHROME SYSTEM INDIA LTD (PARWANOO HIMACHAL) / SURYA JYOTI DEVICE INDIA LTD ( ROPAR PUNJAB) / INTER SOLAR. 140 S&F Rotational moulded poly-ethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified having capacity of 500 Ltrs complete all as specified and directed. 141 S&F Rotational moulded poly-ethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified having capacity of 750 Ltrs complete all as specified and directed. 142 S&F Rotational moulded poly-ethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified having capacity of 2000 Ltrs complete all as specified and directed. 143 Schedule of Credit Works as listed in Schedule A Part-XVII has been attached in tender in PDF format amount of schedule i.e Rs 17,13,684.78 shall be deducted from the total amount of BOQ to arive at the contract sum.