Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil finishing work |
| 2 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.; In cement mortar |
| 4 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 5 | Removal and re-arrangement of existing furniture as per the new proposed layout. The bidder has to take care of all the furniture at the time of shifting. The bidder must carry out the work as instructed by the Client/Consultant. If any part is missing or damaged, the work has to be completed without any extra payment. The work includes cost of all types of tools, tackles, all labourers, accessories, etc. Work is completed for all floors, all levels, all depths, all heights, all leads and lifts etc.1. Chair type 1 :RevolvingCaster:: GF to FF:48 Nos 2. Chair type 2 : Fixed Chair ::GF to FF : 38 Nos 3. Chair type 3 :Training room chair : FF to GF : 35 Nos 4. Workstation : 1800 X 900 X 750 mm : GF to FF : 10 Nos 5. Workstation :1200 X 900 X 750 mm : GF to FF : 3 Nos 6. Workstation : 2250 X 600 X 800 mm : GF to FF : 12Nos 7. Workstation :3600 X 1200 X 750 mm : FF to FF : 1 Nos8. Half H. Storage: 2650 x 1200 mm: 1 Nos. |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above floor V level in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | CEMENT PLASTER (IN COARSE SAND): Providing and laying plaster in all floor, all height, all level : 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) |
| 8 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. Including grooves finish, all floor, all height, all level etc. complete |
| 9 | Wall Punning: Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. |
| 10 | Interior Paint : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 11 | Wall Primer: Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 12 | Exterior Paint: Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 13 | Mirror polishing on marble work/Granite work/kota stone work where ever required to give high gloss finish complete. |
| 14 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick Grey Polished kota stone or yellow river finish kota stone. Grey polished kota stone( 70% ) + Yellow river finish kota stone (30%) |
| 15 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.: 25 mm thick Grey Polished kota stone or yellow river finish kota stone |
| 16 | 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : Second class teak wood |
| 17 | Vinyl flooring : Vinyl flooring:Providing and fixing 2mm thick Exoro Luxury Vinyl flooringincluding necessary material, adhesive, tools, tackles, fittings etc complete. The Material Will be fixed with FEVICOL SR 505 Adhesive. Work complete for at all floor, all level, all depth, all Height, all lead and lift etc. work complete as per the detailed drawing, approved sample, specifications and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC. 2 mm thick Vinyl flooring Code: Exoro LE _201 |
| 18 | Sliding window: (Domal series): Supply & Fixing of Aluminium sliding window with powder coated as per by approved make & sampleby architect/EIC.frame section: 101.5 x 47.5 x 1.5 mm,Shutter section:27 x 65 x 1.54 mm, Glass : 5 mm thick reflective glass of saint gobain or approved make list.including concealed lock, albose, other necessary fixtures and fastening, PVDF rollers, EPDN gasket, silicon sealent etc. complete as per detailed drawings, mock sample and specifications. |
| 19 | Alluminium & Glass Railing :Providing and fixing of Alluminium (6063) glass balcony railing Bottom continue 120*60 mm section powder coated as per approved sample by Architect.Top 50 mm5 mm wall thickness pipe powder coated as per approved shade by Architect/ Client. Glass : 6+6+1.52 laminated toughenedglass as per approved make & Sample by Architect.Height : 1200 mm heighted with installation.Work complete including all type of material, anchor fastening, fittings , fixtures, Finish,loading , unloading , safety measures , transportation,all leads ,accessories,sample mockup, all floor , all levels, all heightsetc complete as per detailed drawings ,specifications & instruction of Client/EIC. sample mock shall be approved fromArchitect/Client. |
| 20 | Fabricated work: Providing Fabrication & erection of steelstructure as perdrawings including materials, consisting of plates, rolled steel joists, channels, angles, chequered plates etc and also rectangular / square hollow steel sections, insert plates in RCC/Brickwork, anchor bolts for steel structure, sleeve pipes, anchor nuts, washers etc, straightening of raw steel if required, fabrication of steel structures with primer and minimum two coats of anti corrosive matt finish paintincluding preparation of supplementary sketches and detailed bill of materials supply of bolts, nuts, washers, shims, packs, putty. gas, welding electrodes and all other consumables, as required and carrying out surface preparation all complete. The scope includes loading, transportation ,unloading and delivery and erection site of all fabricated structures,, alignment and welding of all structures true to line, level, plumb and dimension, including rectification if any, splicing, site assembly all as per technical specifications and drawings,all complete. Contactor shall providestability certificate for thefabrication structure. Rate inclusive of shop drawing. |
| 21 | Providing and fixing 12 mm thick Marine plywood conforming to IS: 710 / WPC board (Seminar Room steps) |
| 22 | Waterproofing Works on Masonry Wall: Providing and applying two coats of Brushbond Aquaprotect - polymer modified cementations waterproof coating tested as per USFDA CFR 175-300 and DIN1048 After carry out proper surface preparation including removing loose concrete, foreign material, cleaning of concrete surface, etc, pre dampening of the concrete surface mixing all components using heavy duty slow speed drill fitted with a mixing paddle followed by application of two coats coverage @1.9 kg/sq.m per coat using a suitable brushas per manufacturer’s instructions. Cured Brushbond Aquaprotect shall having the capability to resist a positive and a negative water pressure when tested to density: 1950 kg/m3,Water Permeability Test EN12390 (part8)Negative pressure: NIL Chloride ion Penetration as per ASTM C1202-03 : Low. |
| 23 | Interior work |
| 24 | Accoustic Baffel Ceiling (Cloud) :Size :- 600MM circleSuspended cloud baffle ceiling \"Ecotone\" make Polyester fiber Acoustic Panel Cloud shape baffle in Selected Colour. The baffle Cloud shall be in size of 600/900 Round27 MMThick in approved shade with Random Spacing . The baffle shall be made by using polyester fiber acousticpanelthicknessof9mm.Thebafflecloudshallbesuspendedusingsuspension hanger of required size and length (as per Cloud Hight) having Fastner , threaded rod , \"J\" Clip etc. With all material and labour etc Completed.The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles, adhesives consumable hardware accessories of approved make for all floors, all heights, all levels and all places within campus. Contractor/Supplier shall do all the needful and shall fulfill Architect\"s design intent. No additional claims will be entertained for this. Work complete as per the Detailed Drawing, & instruction of EIC. Rate shall be inclusive of all materials, loading, unloading, transportation, placing at all floors and for all leads and all accessories as described in item description. Size :-600 MM circle |
| 25 | Accoustic Baffel Ceiling (Cloud) :Size :- 900MM circle\"--------------Do-------------------as per above specification for complete work . |
| 26 | Full Height Partition Gypsum Partition (60min. fire rating) : 100mm thick Gypserra™ stud partition which includes inner layer of tapered edge 12.5mm thick Gypboard® Plain (conforming to IS 2095 Part 1:2011, Certified board) of size 1219x2438mm and outer layer of tapered edge 12.5mm thick Gyproc®Fireline board of size 1219x2438mm is screw fixed to C-stud.48x0.5mm Gypserra™ C-stud {Material-IS 513, Y/S-300Mpa, Finish - AZ150 (IS 15961)} placed at 610mm c/c in 50x0.5mm Gypserra™ {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} floor and ceiling channel.Floor & Ceiling channel is anchored to the floor & True ceiling using Gyproc® Rawl plug Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} /Hilti X-GN20MX anchor fasteners at 600mm c/c in centerline manner.Floor channel to be wrapped with 70μ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. 12.5mm thick Gypboard® Plain board strip of 50mm width is placed between ceiling channel and RCC ceiling slab when deflection is more than 10mm & fire rating is more than 30min. A Gypserra™ noggin channel {Material-IS 513,Y/S-300 Mpa, Finish - AZ150 (IS 15961)} of 50x0.5mm width has to be provided at the horizontal joints of the two boards. First layer of Gyproc® boards to be screw fixed with Gyproc® drywall screws of 25mm at minimum spacing of 600mm at centre and 600mm at periphery. Second layer to be screw fixed Gyproc® drywall screws of 35mm at minimum spacing of 300mm at centre and 300mm at periphery. 50mm Glass wool slab of density 20kg/m³ shall be placed in metal framework. Glass wool holding clip should be used to hold Glass wool slab in its position. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc® Pro-Fill Jointing compound, (Conforms to ASTM C475), Gyproc® Joint Paper tape or fiber tape. The junction of the partition with masonry & all penetration through the partition has to be treated with Hilti/Pyroplex fire and acoustic sealant. All other detailing and specifications to be followed as per approved drawing of Gyproc.Note: Applicator need 60min. fire rating certificates from Gyproc.Rate shallinclude cost of making of all cut-outs for light fixtures, switchboards gadgets, gizmo, pelmets, grooves, beads and also provide support/template where ever required & For door frame fixing, storages, shelves, paneling etc extra Wooden members to be used shall be of CP teak wood only. Including skirting /MDF board/wooden skirting cut out as per EIC instruction at siteThe rate shall be in sq.mt for all floors and at all heights including all costs. including ply base for fixing of TV or Overhead storage wherever required, The rates are also inclusive of necessary scaffolding, tools, tackles,, safety measures , Internal partial support (between two sturd) at 7\" height.The shop drawing (or asample mock of 5 Sqm minimum of the frame work and partition) shall be approved from EIC and Architect. All exposed corner shall be covered with perforated angle as per manufacturer\"s specifications or as directed by EIC. |
| 27 | Thin Profile Single leaf Glass Door: Supply & Installation of Modular Aluminium Glass door 45 X 75 mm System, Using 6063-T6 for Glass Door frame Dimension –105x 30mm. as per approved make list Finish – SILVER finish / Powder coating as per approved sample by Architect 10mm thk. clear thoughened Glass of as per approved make list Door closer of Assa Abloy K990 or Equivalent with confirming to 10 Lakh life cycle & UL certification, Glass Hinge, saddel plate, Mortise lock with handle, Door stopper as per approved make list.Item includes all necessary fitting/ fixing,fixtures of approved make complete as per specification, drawing, approval and instructions of the Architect/Client. Rate shall be inclusive of all material loading unloading at all height and all floor. Sample mock shall be approved from Architect/Client. |
| 28 | Thin Profile Glass Partition :Providing & Fixing ofSTL45 ie.Single glazed modular system consist of Aluminium section of 25*45*2.5 mm thick. All sections duly powder coated with 6063-T6 grade and required accessories ie glass to glass aluminium I sections, T section & 90 degree sections & Glass packing to adjust the floor level. Ceiling profile, Floor profile and wall profile are 25 mm visible face and 45 mm wide with 10mm toughen glass as per approved make& insertion of Thermoplastic gasket to adhere the glass firm & airtight.The sound reduction Value is from 32 to 35 Db.With 6 mm Groove inbuilt in system to accomodate the carpet & the uneven surfaces.Accessories/Hardware: neutral cure glazed& metal silicon sealant of approved make on the periphery of the glass & woodetc.Partition ht will be measured from finish floor to false ceiling level only. The rate shall be in sq.mt for all floors and at all heights including all costs. Glasswidth size shall be as per sugestion by EIC.Work complete including all type of material, fittings , fixtures,Finish, safety measures ,loading , unloading , transporation, all leads ,accessories, sample mockup, all floor , all levels, all heightsetc complete as per detailed drawings ,specifications & instruction of Client/EIC. |
| 29 | Frosted sparkling glass film (Colour film) : Providing and fixing frosted glass film of approved make Translucent, cast PVC, self-adhesive vinyl, special CRYSTAL-effect film to reproduce Sand-blasting effect on glass with customised designs. MCS warranty of 3 (if exposed to direct sunlight) to 10yrs (indoors) must be endorsed by manufacturer. Rate shall be inclusive plotter cutting design as per Architect/Client suggestion. Contractor shall provide shop drawing for approval of Architect/Client.work complete incuding all type of tools, tackles, scaffolding etc complete as per suggestion of Architect/Client. If in case any application finishing will not as per satisfaction contractor shall remove all film at their cost. Contractor shall do a sample mock of 5 Sqm minimum of glass film), shall be approved from Architect/Client. |
| 30 | Alluminium Skirting : Providing and Fixing ofAluminium Skirting as per approved make having width of 75 MM X thickness of 2mm made out of 6063 Grade Aluminium alloy dulypowder coatedas desired in the Ral Colour code decided by the architecthaving neat screw fixed arrangement with Rubber seal over it as per Manufacturers Specification. work complete as per the instruction of Architect. Rate shall inclusive ofmock up sample, all materials, loading, unloading,transportation, placing at all floors and for all leads,all accessories as described in item description. |
| 31 | Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags,fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building. |
| 32 | Accoustic Panelling : 9 mm thick Board - Terracotta shade or as approved by Architect.Providing and fixing wall acoustical panelling with using CS55 and IC91 framing directly to the wall and then fixing 12.5mm perforated board with the help of screw and using rockwool of 50kg density and 50MM thick between framing and perforated sheet then Fixing Ecotone make Marco polyester fiber acoustic wallpaneling with the specification of 9MM thick having density of1.90kg/m2 with NRC value of 0.80 surface matt finish which is fixed with solution SR505 asrequired. The panel should have euro class BASTME84-13 fire rating. The color shade of Panel as approved by Architect. Including all accessories, material & labor complete as directed by Engineer.Including surface preparation, Including cost of all type of tools, tackles, all labour, scaffolding, transportation, cleaning, at all floor, all level, all depth, all Height, all lead and lift etc.etc.work complete as per the detailed drawing, approved sample, specifications and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC. Only the clear elevation area shall be measured and paid. |
| 33 | 3D/ Digital wall paper : Providing and supplying 3D/ Digital wall papersas approved by Architect.Work complete includingall necessary fittings ,Design approval from architect, mock up sample,loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. Basic rate of wallpaper is Rs. 330 / Sq.ft |
| 34 | Roller Blinds : Providing and fixing blinds as perapproved make as per suggested shade & spring drive system with steel ball chain/one touch with speed control action roller blind with end brackets with head rail, components, bottom bar. Fabric : screen classic 3%to 5%Fabric value : 470 Gsm ,Thickness : 0.60 to 0.70 mm Construction: 75 % PVC & 25 % PolysterFabric to be as per approved sample. All the work complete as per the detailed drawing , mockup sampleand instruction of Architect/EIC. All complete as per approval of designer. The mode of Measurement: The size of the blind will be measured from end to end bracket (Left to Right bracket) height will be measured from top of the pelmet to sill bottom level and clear opening size only there will be not extra payment towered overlapping.& mockup sample approved by the Architect/ EIC. |
| 35 | Keyboard : Metal keyboard tray with Outer Dimension of the Keyboard tray is 507 x 245mm made of 1mm thick CRCA as per approved shade powder coatingfixing with require all necessary acessories etc complete. |
| 36 | C.P.U. trolly: for storage of C.P.U. unit conveniently under the table,This saves valuable desk top space. Soft vibration pads provided, Width adjustment of 95mm (3 3/4”) provided, wheel dia 30mm,load capacity 12kgs and set height 43mm,material steel with Nylon Castors and Black / Anthracite / White Matt finish. |
| 37 | Cabin table Unit : Table top : 1800 x 750 x 750mm, Side Unit :1050 x 450x 750 mm, Pedestal Unit-400x470X545.Providing and fixing table unit consist main table, side table ,back storage with pedestal unit with all necessary accessories keyboard, CPU stand ,cable manager, modesty panel etc with all required necessary accessories. All finishes laminate,powder coating /anodizing shade shall be approved by architect. Rate shall inclusive of mock up sampleproviding and fixing at site ofunit for approval of architect.Table top : 25 mm thick postfoam top (reverse bull nose) with 1 mm thick VNR laminate finish as per approved make and sample by Architect/ Client. Verticle support: Combination of alumium extrusions(6005-T6) & aluminium dia cast component (LM-24).4.Horizontal Support: Aluminium extrusion (6005-T6)Or MS support with powder coated . Wire management: Raceway :0.8 mm thick CRCA horizontal and vertical raceways with metal separator .one way or two way openable flip top box mounted on table top squezze :A special flexible rubber component that allows easy and safe passage of wires. All the exposed edges are sealed with 2mm thick PVC Imported edge banding on sides and bottom. The top and drawer facia are sealed with 2mm thick PVC edge. The drawer unit consists of 1 box drawer and 1 file drawer. The drawer box is fitted with telescopic channel Hettich or Haffle make for free movement. The drawer unit is provided with central locking system, where in the drawer are locked with one key.SS 304 recessed handles are provided for easy opening and closing of drawer. The drawer unit is fitted on castors (optional) for easy mobility. PVC edge banding are imported from Rehau or Dolken of Germany. The complete furniture unit is factory assembled with knock down fittings. Rate shall inclusive of mock up sample, all materials, loading, unloading, transportation, monocoat polish, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing , mockup sampleand instruction of Architect/Client. Equivalent to VNR Series Laminate. |
| 38 | Back side storage unit (750 H x 450 D) mm: Storage Comprising from IS 303 BWR 19 mm thick and 12 mm ply, finish with 1 mm thickLaminate finish as per approved make and shade by Architect. Storage top : 25 mm thick postfoam top with 1 mm thick VNR laminate finish as per approved make and sample by Architect/ Client.Solid Shutter : 25 mm thickcomprising from IS 303 BWR ply & finish with 1 mm thick VNR Laminate . Shelf: 19 mm thk IS 303 BWR ply finish with both side approved laminate. Inner area shall be finished with linear laminate. Ledge/Niche comprising from IS 303 BWR ply finish with 1 mm thick Laminate ,required lighting arrangement.The work shall be done as per the detailed drawing , specifications, sample approved and as directed by the Architect/Client. The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles, adhesives , grooves ,consumable hardware & required SS 304 grade hardware/accessories , Profile handle ,Wooden frame, monocoat polish , pvc edge banding , of approved make for all floors, all heights, all levels and all places within campus. Contractor shall do all the needful and shall fulfill Architect\"s design intent. No additional claims will be entertained for this. Equivalent to VNR series laminate. |
| 39 | 4\"ft height storage:450 mm DepthStorage unit top made up of 25 mm thk MDF Exterior grade The top has a post formation round edge finish with both side laminate .Storage body is made of 18mm thick MDF top with exterior grade finish with both side 1 mm th laminate . Shutter finish with both side 1 mm th laminate. The back of the unit is made from 9mm prelaminated board. All the exposed edges are with 2mm PVC edge Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding.Having premium lock with wave key technology and side and hinged shutters are sealed with 2mm thick PVC edge banding.SS 304 recessed handles are provided for easy opening and closing ofshutter. The units are assembled by knock down fittings such as Minifix & Dowels. All the hardware and Hinges are from Enox/Ebco. PVC edge banding are imported from Rehau or Dolken of Germany .Rate shall inclusive of mock up sample, all materials, loading, unloading, transportation, monocoat polish, placing at all floors and for all leads, all accessories as described in item description. As approval of EIC. All the work complete as per the detailed drawing , mockup sampleand instruction of Architect/EIC. Work complete as per the instruction of EIC. Equivalent to VNR series laminate. |
| 40 | Podium : Podium table : 600 x 750 x 1050 mm Podium table: Outdoor side 19mm thick IS 303 BWR ply with teak veneer finish monocoat polish.Inner side 19mm thick IS 303 BWR ply with veneer finish monocoat polish.MDU consiist 3nos. of drawers.Work complete including Providing &fixing , all necessary hardware and fittings, mock up sample,loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. Basic Rate of veneer : 120 Sq.mt |
| 41 | Puffy: Supplying and placing Puffy.Model Code: Amardeep Bright Puffy as per approved make list and ref image in technical specification sheet.* Wooden frame with high density foam.* Covered with upholstrey of leatherite/Fabric* S.Steel Legs at bottom.* Size: 450x450x450HWork complete includingall necessary fittings ,mock up sample,loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 42 | Two seater Sofa : Supplying and placing Two seater Sofa. as per approved and selection by Architect/ Client.Model Code: Amardeep as per approved make listSize - 1850 (L) x 800 mm (B) x 750 mm (H) or as per ref image.Three-seater sofa - The top shall be of Upholstery with PU Finish. The sofas are made of Metal base with powder coating , reinforced with supportive addendum in the seat. Engineered wood panels form/support the overall design structure, they synergize with the solid wood to offer unparalleled life to the product. Foam padding of multi-density and varying thicknesses provide cushion for the sofa. PU foam used is made Kurlon foam. plants using Indian Technology capable of producing the high-quality flexible polyurethane foam. It provides unparalleled comfort, ease of use and durability. The foam used is 32 Density for seating areas and 28 Density for backrest. The super soft foam used is in seating areas in 32-35 Density High-resilience (HR) foam which is unique and rarely used by manufacturers. Webbing: Interwoven high tensile elastic bands for optimum comfort and endurance. The work shall be done as per the drawing , specifications, sample approved and as directed by the Architect/EIC. The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles,approved make for all floors, all heights, all levels and all places within campus. Contractor shall do all the needful and shall fulfill Architect\"s design intent. No additional claims will be entertained for this.Rate shall inclusive of providingmockup sample for approval of architect. Basic Rate of Fabric : 800 Rmt |
| 43 | Centre table - 900mm x 600mm x 450mmSupplying and placing Rectangular Center table as per approved and selection by Architect/ Client.Model Code: Milo code as per approved make listCenter table top made of Solid wood finished with veneer with Stainless Steel Square pipe frame of 25mm x 25mm x 16guage Duly Polished.Work complete including all necessary hardware and fittings , mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client |
| 44 | Clay Pot/planter box:Providing and fixing of clay pot/plater box as per selection by Architect. Basic Rate of Material: Rs. 1000/Nos |
| 45 | Signages : Providing and fixing Signage\"s comprising from combination of HDF sheet & SS plate with laser cutting, 3M Vinyl letter with framing work if required with anti corrosion paint.The rate shall be for complete item inclusive of all material, buffing edge, labor, wastages, necessary tools & tackles, adhesives, consumable hardware & required SS 304 grade hardware/ accessories of approved make.Work complete including all type of material, fittings, fixtures, Finish, loading, unloading, transporation, all leads, accessories, sample mockup, all floor, all levels, all heights, etc complete as per drawings, specifications & instruction of Client/EIC. |
| 46 | Painting : Providing Wall paitingas per Architects selection . Basic rate of paintingis 3000/- NosWork complete includingall necessary fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 47 | Artifacts: Providing and supplying Artifacts as per selection . Glass/Metal/Fiber/CeramicBasic rate of Artifectsis - 4500 NosWork complete includingall necessary fittings ,mock up sample,loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 48 | Door mat : 450 mm X750 mmProviding and supplyingDOORMAT- SUPERLIVING (MATH WITH RUBBER BACKIN) POLYSTER/JUTEas per selection . Work complete includingall necessary fittings ,mock up sample,loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 49 | Providing and placing in position SS brush finish (5 LTS PEDAL BIN/ STEP BIN -) of Pedal bin 200x300 Stainless Steel Dustbin or Equivalent as per images and as selected by the Architect. |
| 50 | Grid Ceiling of Opta™ E (0.8 NRC): Providing and fixing tiled false ceiling of size 600x600 mm in true horizontal level suspended on interlocking Gyproc® Micro grids. It consists of main T runner of size (35x15x0.3x3000)mm, Gyproc cross T runner of size (35x15x0.3x1200)mm, Gyproc® secondary cross T runner of size (35x15x0.3x600)mm. Gyproc®Ceiling fastener with bracket is fixed to soffit , creating (1200 x 600/1200)mm grid. Gyproc® Main T runners are then suspended at 600mm c/c from ceiling using 4mm zinc electroplated butterfly level clips of size (85x30x0.8)mm spaced at maximum 1200mm center to center along main T runner and not more than 150mm from spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from the adjacent wall. 1200 mm cross T is interlocked between the main T at 600mm center to center to form a grid of 1200x600mm and then Gyproc® 600 mm secondary cross Tis then interlocked at middle of the (1200x600)mm grid to form grids of (600x600)mm. Cross T at the ends having length more than 600mm are to be supported independently. Finally, Ecophon Opta™ Etiles of size (595x595)mm and overall thickness 15mm, NRC-0.8 placed in the grid. Saint-Gobain Ecophon Opta™ E with tegular edge and 15 mm thickness, visible surface of each tile is 7 mm below the grid, visible surface is a batch painted glass tissue in white, back of the tile covered with glass tissue. • Size 600x600x15mm, • Manufacturing- Manufactured in Sweden, production unit is ISO 14001 certified. , • Acoustics-Sound absorption (Alpha W) - 1 at 200 mm o.d.s as per EN ISO 354 , • Acoustics-Sound absorption Class - Class A at 200 mm o.d.s as per EN ISO 11654, • NRC - 0.8 NRC as per ASTM C 423, • Fire Safety - Tested and classified as non-combustible according to EN ISO 1182 with reaction to fire classification class A2 s1 d0 according to EN 13501-1 – European Standard., • Flexural tensile strength - Class C/3N, • Indoor Air quality - Complying with the French regulation on VOC emissions, A level. Certified by the Finnish Building Information Group (RTS) with the M1 label. Certified by Eurofins Indoor Air comfort., • Product Certified under GRIHA council of India for Green Ratings, IGBC Green Pro certified, Comply with the REACH regulation of the European chemical Agency, certified by the EUCEB which confirms that mineral wool is produced in conformity with the Note Q of EC No 1272/2008 and therefore classification as a carcinogen does not apply., •Environmental Footprint - Environmental Product declaration (EPD) acc to international ISO 14025 & EN 15804 series of standards. , • Circularity - Minimum post-consumer recycled content 47%, Fully recyclable, • Humidity Resistance -Class C, relative humidity 95% and 30°C, according to EN 13964:2014, • Light Reflectance - 83% light reflectance. Cleanability- Weekly dusting and vacuum cleaning. , • Accessibility - The tiles are easily demountable, CE Marking - Ecophon ceiling systems are CE marked according to the European harmonized standard EN13964:2014. CE marked construction products are covered by a Declaration of Performance (DOP) which enables customers and users to easily compare performance of products available on the European market. |
| 51 | ELECTRICAL |
| 52 | Removing & Reinstallation of Existing Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduitas required.: 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 53 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.: 25 mm |
| 54 | Removing and Refixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.: 5/6 amps switch |
| 55 | 2 way 5/6 A Switch |
| 56 | 15/16 A switch |
| 57 | 3 pin 5/6 A socket outlet |
| 58 | 6 pin 15/16 A socket outlet |
| 59 | Telephone socket outlet |
| 60 | Removing and Refixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.: 1 or 2 Module (75mmX75mm) |
| 61 | 3 Module (100mmX75mm) |
| 62 | 4 Module (125mmX75mm) |
| 63 | 6 Module (200mmX75mm) |
| 64 | 8 Module (125mmX125mm) |
| 65 | Removing and Refixing following Modular base & cover plate on existing modular metal boxes etc. as required.: 1 or 2 Module |
| 66 | 3 Module |
| 67 | 4 Module |
| 68 | 6 Module |
| 69 | 8 Module |
| 70 | Removing and Redrawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.: 1 run of cable |
| 71 | Removing & Re-fixingfollowingway,horizontaltypethreepole andneutral,sheetsteel,MCBdistributionboard,415V,on surface/recess,completewithtinnedcopperbusbar,neutral busbar,earthbar,dinbar,interconnections,powderpainted includingearthingetc.asrequired.(Butwithout MCB/RCCB/Isolator): 8 way (4 + 24), Double door |
| 72 | Removing & Refixing under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all accessories,Junction Box,Jointsas required and demanded by engineer-incharge andlaying/erectingas per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D x T) Cat-III: [9] 100mm x 38mm x 1.6 mm with One Compartments |
| 73 | [10] 150mm x 38mm x 1.6mm with Three Compartments |
| 74 | [13] 300mm x 38mm x 1.6 mm with Three Compartments |
| 75 | Removing & Refixing under floor pregalvanised corrosion proof rectangular sheet steel cable Floor Junction boxes with Space Cut provision for fixing Tile/Carpet of Required size complete with Finishing and concealing of boxes in floor.: 200mm x 200mm x 65 mm Deep |
| 76 | 250mm x 250mm x 65 mm Deep |
| 77 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air deliveryminimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. |
| 78 | Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box. |
| 79 | Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without leakage and earthing. |
| 80 | Supplying & erectingfan hook box of10 mm M.S. round bar bounded to the RCC bars up to 50mm length each side and pierced through a16 Gauge M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with necessary finishing. |
| 81 | Supplying and erecting approved make double ball bearing oscillating type Heavy duty bracket fan with Aluminium Blades A.C. 23OV. 50cy/s wall mounted with height adjustment and rotary tilting device complete with guard, wall bracket,mounting accessories as directed. (A) 450mm |
| 82 | \"Supply Installation Testing Commisioning ofIndoor deep Recessed Round COB downlight27-30W Recess Mounted Round 36-40 DEGREE COB downlighter with below features 1. Pressure die cast Aluminum alloy housing for better thermal conductivity. 2. . Round Version.3. Efficacy of Fixture more then or equal to 85 Lumens /watt Available with 5700K, 4000K & 3000K CCT.4. CRI>80, High efficiencydriver with inbuild surge protection, over voltage protection, short circuit protection and operating at >0.9 PF. <5% THD 6. The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported . (Approved Led source Nichia , Cree, Lumileds , Osram Only). Multiple Fixture BODY color options/RAL code option should be provided to architects team for selection.Fixture/Fitting needs to be approved by the architect before installation Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva\" |
| 83 | ELV SYSTEM |
| 84 | SITC of4MP Fixed Lens Dome Type Camera,H.265 4MP IR Vandal Proof Dome N/W Camera, 2.8mm/3.6mm, 30M IR, Micro SD, DC12V/PoE, IP67/IK10, Basic IVA, 1 / 2.7\" CMOS, 2560 × 1440, 0.01 Lux, F1.2, AGC ON; Defog, True day/night, Digital WDR, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Cyber Security, Basic intelligent video analytics, NDAA Compliance, UL, CE, FCC Certified |
| 85 | SITC of Conduit Box for CCTV |
| 86 | SITC of Face Plate - Single (Keystone Jack,square) |
| 87 | SITC of Back Box |
| 88 | Removing & Reinstallation Of TV complete with bracket and fittings. |
| 89 | HVAC work |
| 90 | Replacement of defective remote control panel assemblyunit of Split air conditioner. |
| 91 | Shifting of Split A.C. The Scope includes dismantling, shifting, re-installing & re-commissioning of the units including topping up of Refrigerant gas, minor civil work wiring existing piping M S Stand electrical cabling with PVC drown piping for 1.00, 1.5 & 2.0 TR capacity. |
| 92 | Replacing the defective indoor unit body bysupplying and erecting new complete set of body up to 2.0 TR |
| 93 | Overhauling and servicing the Splittype A.C.MACHINES by Chemical cleaning ofthe condenser, cooling coil etc. by veniclean/Eq. material, water & cleaning all necessary parts and putting the machine in working order. |
| 94 | Replacement of defective Oscillatinglouvers of Split air conditioner up to 2.0 TR capacity. |
| 95 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.: (E) 19 mm dia. |
| 96 | Rate only Item |
| 97 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 98 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 99 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm |
| 100 | Single Leaf Flush Door finish with laminate: Providing and fixing in position 40 mm thick BWP grade single leaf flush doors of approved make and finished withboth side 1 mm thickVNR laminate as approved sample, Hardware system as per approved make & Sample (Hinges, Mortise lock with 3 pair key, Door stopper, door closer ). Door closer and mortise lock of Dorma/Geze/Haffle as per approved make by Architect. Hinges, Door stopper and other accessories of Kich/Ozone/Inox as per approved make by architect. work complete including all type of hardware, fittings , fixturesas per instruction of Client/ Architect etc complete as per detailed drawings and specifications. sample mock shall be approved from Architect/Client. Equivalent to VNR Series Laminate. |
| 101 | FRMR board Ceiling with30min fire rating :M/F Suspended 30min Fire Resistance ceiling includes Gypserra™ Perimeter Channel {Material-GI(IS513),YS-260Mpa,Finish- Galvanised 150GSM(IS27 )} is fixed along the perimeter of existing wall/ partition with the help of HILTI HPS - 1 (6x40) impact anchor, at 600mm centres.Gypserra™ Ceiling Angle {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is suspended by fixing it to the Gyproc® soffit cleat {GI(IS513)YS-260Mpa,Finish-Galvanised 150GSM(IS277) }. Soffit Cleat and Gyproc® Rawl Plug- Ø8x45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1220mm x 1220mm grid. Gypserra™ Intermediate channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277) } is fixed to the Gypserra™ Ceiling Angle with M6 x 12mm Hex Bolt & Hex Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13 Gyproc® metal to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.} The Gypserra™ Ceiling Section {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is then fixed to the Gypserra™ Intermediate Channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} with the help of Gyproc® Connecting Clip {Material-High carbon spring steel wire(BS970Gr.En42)-46-48HRC,Finish- Zinc plating 4-6 micron} and in direction perpendicular to the Intermediate channel at 457mm c/c. Use 50mm thick rockwool above celing for fire insulation, then Single layer of 15mm tapered edge Gyproc FRMR Board as per (EN 520:2004, Type F & H1 ASTM C1396, Type X)is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-ISO 7049/50,Finish-Case hardened Grey Phosphating} at 230mm centres on ceiling section & 150mm at periphery of ceiling. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc® Easy-fill 90 Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape. Serrated section has effective thickness of 2T ( 2xdepth), better load carrying capacity. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge/Manufacturers Specification.Necessary cutting / providing openings in the ceiling for AC fixtures, grills, electrical fittings, or other utility services, hatch openings etc. shall be provided by the Contractor and cost of making such modifications shall be included in the price. No separate charges for cutting / providing opening will be paid. Trap doors with necessary ply frame workto be provided as required at no extra cost.Work complete as per the detailed drawing and instruction of Architect/EIC. |
| 102 | Grid ceiling : Providing and fixing false ceiling at all heights with Eco – Friendly light weight calcium Silicate Modular Acoustical grid ceiling of dimension 595X595 MM having 15 MM thick integral densified edges reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50(minimum) as per IS 8225:1987, Product should have Zero VOC( Eco- friendly ) & More than 50% Recycled contents for high green building Poi Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4)& BS:476 (part 6 &7), Also the product should UL-723 & ASTM Complying 100% with NFPA Guide lines Light reflectance of 85% (minimum). Non-combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043W/mK as per ASTM 518:1991, in true horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising ofmain- T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of theEngineer-in-Charge. |
| 103 | Laminate paneling: Providing & fixing 12mm thick fire retardant marine plywood as per IS 710:2010 and IS 5509:2000 fixed on frame work finish with 1 mm thick laminate.The frame work shall be made from square hollow aluminium anodised section size of 50x50x1.5 mm & 25x50x1.5 mm of approved make conforming to IS code.The framework shall be fixed as per drawing vertically @ 600 mm c/c & horizontal 1200 mm c/c horizontally.All ply/wooden shall be treated with anti- termite treatment .Measurements for paneling work to be recorded upto finished false ceiling level only irrespective of aluminium frame work, which shall be provided from gr.level to RCC slab / beams soffit level.Rates shall also be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights /air-conditioners ,grills, diffusers etc & providing additional sections for strengthening around the openings/cutouts additional support for fixing of patch fittings for doors, making grooves between wall & board, in filled with termite treated wooden members if required or as per drawing /instruction of EIC. and no extra payment shall be considered for additional sections provided.All curved surfaces, recesses, waffles shall be part of the paneling including openable shutter wherever required area and finished with the same material.Work complete including all type of material,CNC , Engraving ,fittings , fixtures, Finish, loading , unloading , transportation,all leads ,accessories, groove,adhesive ,tape, headless nails, sample mockup, all floor , all levels, all heightsetc complete as per detailed drawings ,specifications & instruction of Client/EIC. only the clear elevation area shall be measured andpaid. sample mock shall be approved from Architect/Client. Equivalent to VNR Series Laminate. |
| 104 | Desk System : 1500 mm x 600 mm x 1100 mm Providing and fixing of Desking sysrem, with 30mm screen on the top with soft board and white marker. Flipup on the top for plugin. Alumnium legs with Metal passage side modesty.TABLE TOP:- Table top is made of 25mm E1 Gradepre-laminated particle board with PVC edge banding with Grommet provisionPrivacy: Glass screen as per selection by architectWIRE MANAGEMENT :MS-POWDER COATEDwire tray with switch plate 150D/300D*120H below the table top and concealed leg with Grommet size 120 x120D on table top is considered.Legs made-up of aluminum and fixed with die-cast connector which makes weld-free design, straight 90degree. Extrusion are made in trapezoid shape which gives aesthetically appealing sleek look.BEAMS: :Leg to Leg Beam will be made of Aluminum extruded powder coated with Trapezoidal cross section of size 55 x 40 x 65mm. Horizontal beams below table top will be with 40mm x 30mm rectangular tube CRCA Powder coated.MODESTY : :Below wire tray MS powder coated Modesty of 300H is considered. including LedgeKeyboard : Metal keyboard tray with Outer Dimension of the Keyboard tray is 507 x 245mm made of 1mm thick CRCA as per approved shade powder coatingfixing with require all necessary acessories etc complete.C.P.U. trolly: for storage of C.P.U. unit conveniently under the table,This saves valuable desk top space. Soft vibration pads provided, Width adjustment of 95mm (3 3/4”) provided, wheel dia 30mm,load capacity 12kgs and set height 43mm,material steel with Nylon Castors and Black / Anthracite / White Matt finish.Work complete as per drawing & direction complete with all standard fittings & fixtures, levelling screws etc. Proper fixing arrangement to floor/tiles for partition. |
| 105 | MOBILE PEDESTAL - PLB: 2Drawer+1 Filling Unit: 400W*450D*650H E1 grade 18 mm thickPreLaminated Mobile pedestal unit with 3 drawers. Upper 1 box drawers + 2 file drawer provided with Inner Metal Powder Coating Boxing sliding with soft closure Telescopic channels.The drawer unit is provided with central locking system, where in the three drawer are locked with one key.SS 304 recessed handles are provided for easy opening and closing of drawer.The drawer unit is fitted on castors (optional) for easy mobility. PVC edge banding are imported from Rehau or Dolken of Germany. The complete furniture unit is factory assembled with knock down fittings. Work complete as per drawing & direction complete with all standard fittings & fixtures, levelling screws etc. |
| 106 | Revolving Chair : Supplying and placing Revolving Chair with Seat.Model Code: EVO code make as per approved make list Work complete including all necessary hardware and fittings , mock up sample, loading,unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client |
| 107 | Console : Providing &fixing Console complete as per drawing/Ref Image. Approx size : 1500 x 400 x 600 mmmade fromup of 19 mm thick BWR grade ply & finished of Laminate as perapproved make and shade and solid wooden leg with matt finish monocoat polish as per drawing. Rate shall be inclusive of providing, fixing all necessary brass satin finish nickel plated/ S.S 304 grade (hardware from Hettich like Auto Hinges, handle, Rod locks, Multipurpose lock,Rate shall be inclusive of internal shelves of19mm thick IS 303 BWRply and laminate ,PVC edge beading . All external & internal exposed woodwork to be finished in PU semi gloss paint finish polish as per specified item\"s manufacturer\"s specifications.Rate shall inclusive of providing mock up sample for approval of architect. Equivalent to VNR series laminate. |
| 108 | SITC of Next generation enterprise Wi-Fi 6 (802.11ax) access points, It should be resilient, secure, and intelligent. Comes with Embedded Wireless Controller, Minumum 4 nos of 2.4 GHz 2 dBi/5 GHz 4 dBi Dipole Extranal Anttena, AP’s should be tested under Common Criteria Certification. and complying to details technical specs in attacehd sheet |
| 109 | Providing and erecting Inverter based approved make split air-conditioning unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means ofextra supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco Friendly green gas charging and 15A plug top & Remote Control & MS Stand) with necessary core cutting. (2)For 4/5 Star Rating of current year. : (C) for 1.7 to 2ton capacity |
| 110 | Supplying & installing MS standard type stand mounting for outdoor unit of Split A.C. upto 4 TR capacity erected with necessary hardware materials as directed. |
| 111 | Supplying and erecting insulated pair of soft copper tubing open or concealed including power and control cable,necessaryPVC drain pipes for Split AC machine up to 4 TR capacity |
| 112 | (C) Cordless Remote Control |
| 113 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.: (A) 50 mm dia. |
| 114 | Labour charges for Shifting of Existing furniture or any type of work like shifting, remove and Reinstallation/ fixing itemas per specified location as per direction by EIC/Architect. etc. complete. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy