| 1 | 1)Constructing Underground Gutter At Hingani N, Tal- Mohol. |
| 2 | Excavationfor roadway in earth, soil of all sorts, sand,gravel orsoft murum including dressingsectiontotherequiredgrade,camberandsideslopesandconveyingthe excavatedmaterials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. MORTH 301 |
| 3 | Removingrichmixcementconcreteincludingstackingthespoilsasdirectedwithall leads, lifts etc, complete.As directed by Engineer in charge. |
| 4 | Providingand laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, levelandslopeincludingnecessarycollars,excavation,laying,fixingwithcollarsin cement mortar 1:1 and refilling the trench complete. Bd.V.41, Page One Number 573 |
| 5 | Providing and constructing Brick MasonryInspection Chamber 60cm x 45cm x 90cmincluding 1:4:8 cement concrete foundation 1:2:4 cement concrete channels halfround G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. Bd.V.43, Page One Number 574 |
| 6 | Providing, laying andfixing P.V.C. pipe of 75 mm. dia. withfittingssuch as bends, tees,reducers,clamps,etc.includingnecessary excavation,trenchfillingetc.complete. Including removingexistingpipelineifnecessaryandconveyingandstackingthe sameinPWD chowky or as directed etc. complete. As directed by Engineer in charge. |
| 7 | Providing and laying in situ / ready mix M-20 cement concrete of trap /granite /quartzite /gneiss metal for approach slab / Rigid pavement including compacting, finishing, curing etc. complete. (excluding reinforcement) (with reversible drum type mixer/ concrete batch mixplant(panmixer) withSCADAwithfineagreegatesofrequiredspecifications (Natural sand / VSI sand finely washed etc ), cement 6.40 bags/cumt) CD.15 Page.No. 168 and B.7. Page No. 38 |
| 8 | Providing second classBurntBrickmasonrywithconventional/I.S.typebricksin cementmortar1:6infoundationsandplinthofinnerwalls/inplinthexternalwalls includingbailingoutwatermanually,strikingjointsonunexposed faces,rakingout jointson exposedfaces and watering etc. Complete. Bd.G. 1 Page One Number 313 |
| 9 | Providinginternalcementplaster20mmthickin Singlecoatsincementmortar1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Bd.L.4 Page One Number 368 |
| 10 | ProvidingandlayingRoughShahabadStoneFlooring25mmto30mmthickandof requiredwidthinplain/diamondpatternonabedof1:6C.M.includingcementfloat, striking joints, pointing in cement mortar 1:3 curing and cleaningetc. complete. Bd.M.1 Page One Number 379 |
| 11 | Providingsoak pitofsize 120cm x120cm x120cmincluding excavatingandfilling with brick-bats. Bd.V.46, Page One Number 576 |
| 12 | BASIC TEST OF Compressive Strength OF C.C. Cube (Set of 3 cubes). |
| 13 | Roalty Chrgess for Sand |
| 14 | Add 18% Of G.S.T. |
| 15 | 2)Constructing underground Gutter at Hingani N, Tal- Mohol. |
| 16 | Excavationfor roadway in earth, soil of all sorts, sand,gravel orsoft murum including dressingsectiontotherequiredgrade,camberandsideslopesandconveyingthe excavatedmaterials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. MORTH 301 |
| 17 | Removingrichmixcementconcreteincludingstackingthespoilsasdirectedwithall leads, lifts etc, complete.As directed by Engineer in charge. |
| 18 | Providingand laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, levelandslopeincludingnecessarycollars,excavation,laying,fixingwithcollarsin cement mortar 1:1 and refilling the trench complete. Bd.V.41, Page One Number 573 |
| 19 | Providing and constructing Brick MasonryInspection Chamber 60cm x 45cm x 90cmincluding 1:4:8 cement concrete foundation 1:2:4 cement concrete channels halfround G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. Bd.V.43, Page One Number 574 |
| 20 | Providing, laying andfixing P.V.C. pipe of 75 mm. dia. withfittingssuch as bends, tees,reducers,clamps,etc.includingnecessary excavation,trenchfillingetc.complete. Including removingexistingpipelineifnecessaryandconveyingandstackingthe sameinPWD chowky or as directed etc. complete. As directed by Engineer in charge. |
| 21 | Providing and laying in situ / ready mix M-20 cement concrete of trap /granite /quartzite /gneiss metal for approach slab / Rigid pavement including compacting, finishing, curing etc. complete. (excluding reinforcement) (with reversible drum type mixer/ concrete batch mixplant(panmixer) withSCADAwithfineagreegatesofrequiredspecifications (Natural sand / VSI sand finely washed etc ), cement 6.40 bags/cumt) CD.15 Page.No. 168 and B.7. Page No. 38 |
| 22 | Providing second classBurntBrickmasonrywithconventional/I.S.typebricksin cementmortar1:6infoundationsandplinthofinnerwalls/inplinthexternalwalls includingbailingoutwatermanually,strikingjointsonunexposed faces,rakingout jointson exposedfaces and watering etc. Complete. Bd.G. 1 Page One Number 313 |
| 23 | Providinginternalcementplaster20mmthickin Singlecoatsincementmortar1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Bd.L.4 Page One Number 368 |
| 24 | ProvidingandlayingRoughShahabadStoneFlooring25mmto30mmthickandof requiredwidthinplain/diamondpatternonabedof1:6C.M.includingcementfloat, striking joints, pointing in cement mortar 1:3 curing and cleaningetc. complete. Bd.M.1 Page One Number 379 |
| 25 | Providingsoak pitofsize 120cm x120cm x120cmincluding excavatingandfilling with brick-bats. Bd.V.46, Page One Number 576 |
| 26 | BASIC TEST OF Compressive Strength OF C.C. Cube (Set of 3 cubes). |
| 27 | Roalty Chrgess for Sand |
| 28 | Add 18% Of G.S.T. |
| 29 | 3)Constructing Paving Block infront of Village Panchayat Office at Hingani N.,Tal- Mohol. |
| 30 | Excavationfor roadway in earth, soil of all sorts, sand,gravel orsoft murum including dressingsectiontotherequiredgrade,camberandsideslopesandconveyingthe excavatedmaterials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. MORTH 301 |
| 31 | Providing, laying, spreading and compacting stone aggregates of specific sizes towater bound macad amspecification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening /binding Materials to fill up the interstices of coars eaggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means-GradingI (Using Screening TypeB (11.2mm) Aggreg MORTH 404 |
| 32 | Providingandfixingheavy duty interlockingconcreteRUBBERMOULD GLOSSYPAVINGBLOCKSof60millimeterthicknessofhavingastrengthof400 Kilogram/sq.mofapprovedqualityandshapeonabedofcrushedsandof25to30 millimeterthickincludingstrikingjointsandcleaning etc.complete.(using100% crushed sand) Bd. M-12 page One Number 385 |
| 33 | Providing and laying in situ / ready mix M-20 cement concrete of trap /granite /quartzite /gneiss metal for approach slab / Rigid pavement including compacting, finishing, curing etc. complete. (excluding reinforcement) (with reversible drum type mixer/ concrete batch mixplant(panmixer) withSCADAwithfineagreegatesofrequiredspecifications (Natural sand / VSI sand finely washed etc ), cement 6.40 bags/cumt) CD.15 Page.No. 168 and B.7. Page No. 38 |
| 34 | BASIC TEST OF C.C. Block |
| 35 | Roalty Chrgess for Sand |
| 36 | Roalty Chrgess for Other Metal |
| 37 | Add 18% Of G.S.T. |
| 38 | 4)S.R. to Magasvargiy Samaj Mandir at Hingani N., Tal- Mohol. |
| 39 | Removingcementtiles,ormarbleorpolished shahabadfloorordadowithoutbed concrete including stacking the materials as directed with all leads, lifts etc. complete As directed by Engineer in charge. |
| 40 | Removing doorsandwindowswithframesandstackingthematerialsasdirected withall leads, lifts etc. complete. As directed by Engineer in charge. |
| 41 | Providing and laying in situ, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, compacting and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer, With natural sand. Spec. No.: Bd. E. 1 Page No. 287 |
| 42 | Providing and laying damp proof course 50 mm thick in M20 cement concrete layerand bitumen / using cement with waterproofing compoundcuring, formworketc.complete. Bd.J.2 Page One Number 355 |
| 43 | Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to605mm x590mm to605mm of8to10mm thicknessandconfirmingtoIS. 15622-2006(groupBla)ofapprovedmake,shadeandpatternforflooringinrequired positionlaidonabedof 1:4 cement mortar including neat cement float, filling joints,curingandclearing etc. complete. Bd.M. 12 Page One Number385 |
| 44 | Providing and laying vitrified stone effect finish tileshaving size 590 to 605 mm x 590 to 605 mm of 8 to10 mm thicknessandconfirming toIS. 15622-2006(Group Bla)of approved make, shade and pattern for dado and skirting in required position fixed in1:4 cement mortar including requiredpositionlaidonabedof1:4cement mortarincluding neatcementfloat, filling joints, curign and cleaningetc. complete. |
| 45 | Providing and fixing double leaf steel door without ventilator including shutter of MS frame of angle 50x50x6 mm and shutter frame of MS angle of 30x30x6 mm and shutter sheet of 10 guage of approved quality with hold fast neceaasry fixing and fastening and fixtures,necessary welding with oil painting three coats including primer coate complete as per detailed drawings and as directed complete. |
| 46 | Providing and applying washable oil-bound distemper of approvedcolour andshade to oldand new surfacesintwocoatsincludingscaffolding,preparingthesurfaces. (excluding the primer coat.) etc. complete. Bd.P.5 Page One Number 413 |
| 47 | Providing and applying two coats of water proof cement paint of approved manufacture andofapprovedcolourtotheplasteredsurfacesincludingscaffoldingifnecessary, cleaning and preparing the surface, watering for two days etc.complete. Bd.0.8 Page One Number 406 |
| 48 | Basic test Conarete Compressive Strength of C C Cube (Set of 3 cubes) |
| 49 | Royalty Chargess for Sand(Attached Separate Sheet) |
| 50 | Add 18% Of G.S.T. |