| 1 | Supply and fixing offactory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect.CAT-AAA |
| 2 | S&Fof 63 Amp. 415 V metal clad TPN HRC Rewireable type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. |
| 3 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.807 (B)25 A TPN |
| 4 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swgand inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) |
| 5 | Supply and wiring of submains with 3 nos. 2.5 sq mm & with 1 no earth wire of 2 No. 1.5 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour andT & P etc. required for proper completion of the work as directed by Engineer in charge. |
| 6 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. |
| 7 | Supply and fixing of single unit neon aviation obstruction light (GEC-ZH750) / Bajaj BJAOL-1 complete withtransformer and neon spiral etc. at the top of the building complete in all respect. |
| 8 | S/F of 16 mtr. High Mast shaft of approved make with rising system hot dip glavanized inside & outside dip, heaving pole sheet thickness 3mm. Top dia mimimum 150 mm. Bottom dia 360 mm. Base plate 35 mm. thick suitable for wind velocity as per IS 875 Part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 1.5 HP power tool moter, 3 Point suspension system with steel wire rope 6mm. dia, double drum winch, including making suitable foundation as per manufacture drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc. complete in all respect. |
| 9 | supply of 150 Ltr Capacity Usha Make Model No. SS 150/150 with refrigerator R-22 having cooling capacity 150 Ltr with extra large stainless steel body with water tap 02 no. complete in all respects. |
| 10 | Supply of 4 KVA Stabilizor range 140-280 with plug top complete in all respects. |
| 11 | Installation and Commossioning charge of water cooler including connection complete in all respectsApp. |
| 12 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 15 mm, having thermal stability for hot & cold water supply, complete in all respect. |
| 13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 25 mm, having thermal stability for hot & cold water supply, complete in all respect. |
| 14 | Supply and Fixing of Brass stop cock of approved make complete in all respects. |
| 15 | Supply and Fixing of waspipe of 40mm for wastage water drain from water cooler. |
| 16 | |Construction of 2.0 mtr.X1.5mtr. X10Mtr. cage made of 50mmx 50mm X 5mm angle Iron with10 HWG welded wire mesh of size 1\" X2\"Gavalinized GI sheet of 24 HWG on roof top and side to protect the coller from rain the foundation of cage shall be 0.15 m in 1:2:4 cemetn concerete bae and brick work. Work including labour material for proper completion of work. |
| 17 | Supply of hosting of sintax or equivalent high density polythylene seamless ofpoece mound tank complete in all respect. |
| 18 | Supply and fixing of power plug with 20 Amp./250 voltflush type modular switch and 5 pin 20 A/250 volt flush type universal modular socketswitch on concealed M.S boxincluding supply of all material, labour T&P etc. required for proper completion of work. |
| 19 | S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve |
| 20 | S&F of6 Amp. to 32Amp. DP MCB (10 KA) C Curve |
| 21 | S&F surface/flush mounting 4 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed at site byEngineer in charge. |
| 22 | S/L of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer –Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.6Sqmm 2 core - |
| 23 | Supply and fixing of one number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
| 24 | Supply and fixing of 32 Amp. 415 V metal clad T.P.N. rewireable type switch fuse unit on Angle Iron Bracket complete with all respects. |
| 25 | Supply of 1HP submersible pump set with starter UPIN 65m head (Pluga/Crompton Greeves /KSB) |
| 26 | Supply and fitting of 4sqmm 3 core copper wired cable (ISI mark) complete in all respect |
| 27 | Installation of 1.0 HP submersible motor pump with 32mm G.I. Lowering, submersible cable 4sqmm & installation of starter including supply of labpur, T&P etc complete in all respect Jal Nigam |
| 28 | Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 and aboveProtection complete in all respect.CAT- AAA |
| 29 | Dismelting of LED street light |
| 30 | Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc 25 Sqmm X 3.5 core. |
| 31 | 16 Sqmm X 4 core |
| 32 | S/F of Plam and pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape, and making connections etc. complete in all respects as per direction of the Engineer incharge 25 Sqmm X 3.5 core |
| 33 | 16 Sqmm X 4 core |
| 34 | Supply & fixing steel tubular pole 9.50 Metre long designated 410 SP-36 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. |
| 35 | Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete inall respects. |
| 36 | Supply & erection of over head G.I.wire no. 8 to 6 SWG including binding etc. complete in all respect. |
| 37 | Dismelting/Erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete inall respects. |
| 38 | Dismelting/Erection of over head G.I.wire no. 8 to 6 SWG including binding etc. complete in all respect. |
| 39 | Supply & erection of hexagonal / cradle type gaured of G.I.wire no. 8 to 4 SWG including binding/ spacer etc. complete in all respect. |
| 40 | Supply & fixing of 100 mm x 110 mmshackle insulator /100 mm x 80 mm pin insulator including G.I. Bolts / spindlenuts etc. complete in all respect. |
| 41 | Supply & fixing of 230 mm x 32 mm x 1.5 mm galvanised steel strips including holes for shakcle insulators pins andbolts etc. complete in all respect. |
| 42 | Supply & erection of \"D\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint . |
| 43 | S/I/T/C of LT Panel vennin proof floor mounting M.S. Channel base with bottom and fabricated out of 2.0/1.6mm thick CRCA sheet steal painted with powder coated paint of shadeas per the directin of enginne in charge after proper sheet treatment process of dheet dteel. The Cus bar of panel shall be of electrical grade hig conductive aluminum alloy of appropriate cross section as per rating. The main bus bar shall run throughout the panel of rating as main incomer rating. The Busbar shall be supported by non hygroscopic SMC/DMC bus bar supports which shall be mounted on proper interval to ensure the bear the jerks of short circuit of 50KVA for panel having ACB as incomer & 36 KVA for pannels having MCCB Incomers. Panel shall be constructed in fully segregatedcompartment design for each feeder as per 3b construction format the panel shall be completed in all respect as per IS: 8623 part 2&3 There shall be separeate metering compartment for incomer meteing and outgoin meteringAll Incomer feeder shall be provided with multifunction metering along with phase indicating lights and other associated components such as CT, control MCB Terminal Block etc. and all outgoing feeders 100Amp & above shall be prvided with 3 phase ammeter along woth phase indicatin lights and other associated components such as CT, Control MCB Terminal Block etc. The feeders above shall be provided as sccommodated all measuring instruments shall be digital type & all indicating lights shall be LED type.Wiring shall be done from 1100V Grade PVC insulated copper flexible wire. All ACB shall e electrically operated Draw out type with microprocessor Based O/L, S/C & E/F Release of breaking/withstand capacity (ICU/ICs/Icw) 50KA or more All MCCB shall be thermal magnetic/ microprocessor with O/L & S/C protection along with required spreders & extended rotary handle with pad locking facility of breaking capac ity (ICU/ICS) 36KA or more all MCB shall be thermal 10kA \"c\" curve cubicle type switch board shall be Cat-A and B only. Incoming 100 Amp. MCCB-1 No, outgoing 63 Amp. MCCB-1 Nos. and 32 Amp. MCCB-2 No. |
| 44 | Supply & erection of stay set at 3.5 Metres away from the pole complete with galvanised 19 mm dia x1.80 Metre long stay rod, 30 cm x 30 x 6.3 mm anchor plate, thimble stay clamps, stay insulator,19 mm 600 mm double screw tightener,7/3.5 mm G.I. stay wire etc. in 1:3:6 cement concrete complete in allrespect. |
| 45 | Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect |