}

Tender For Provision Of Training Shed And Pt Shed At Lucknow, lucknow-Uttar Pradesh

Military Engineer Services has published Tender For Provision Of Training Shed And Pt Shed At Lucknow. Submission Date for this Tender is 22-08-2025. Shed Construction Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50251576
Tender For Provision Of Training Shed And Pt Shed At Lucknow
Tender
Indian
Uttar Pradesh
Lucknow
22-08-2025

Tender Documents

Tender Details

Tender For Provision Of Training Shed And Pt Shed At Lucknow; 1 Design, fabrication, supply and erecting, Pre-engineered building steel structure/LGSF made from 345 Mpa high strength Hot rolled paletes and factory produced zincalume cold rolled light gauge steel zincalume frame (1 mm BMT)for provision oftraining and PT Sheds of size and shape mentioned in architectural drawing using 0.45 mm base metal thickness, pre-painted 0.50 mm corrugated galvalume aluminium zinc coating (AZ-150 GSM) aluminium zinc alloy coated colour having tensile strength of 550Mpa as in roofingfixed with self tapping screws including S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.60 mm thick (AZ not less than 150) of colour having tensile strength of 550Mpa as in ridge/valley gutter roof covering/cladding to wall fixed with self tapping screws, (factory made valley gutter, shape and size directed by Engineer-in Charge including supply of bolts, gutter bolts, screws, washer, pipe nails distance pieces, plug, holder bats for pipe and all jointing materials, down take pipe, downspout pipe and metal clamp of appropriate size and shape and LGSF structure with brick work in CM 1:4 onas per mentioned in architectural drawing all as specified with following design parameters all as specified and vetted design and drawing by any IIT/NIT and approved by Chief Engineer Lucknow Zone with permanent specification complete all as specified and as shown on drawing:-(i) Frame type Pre-Engineered Building (ii) External size of training and PT shed as perarchitectural drawing (iii) LGSF structure with 1 mm to 2.5 mm thick(iv) Anti-corrosion treatment and painting as per IS -1477 Part 1 & 2 .(v) PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate including form work in base of footing.(vi)RCC work M-30 in footing, plinth beam & Stair case/steps as per approved mix design and as per IS:9103(vii)All necessary civil works for setting for super structure layout, excavation, back filling, removal of surplus soil, RCC foundation/footing, plinth beam, RCC sitting step with granite finish including bull nosing finish & Stainless steel railing complete.Note : (i) Design parameters of PEB structure is attached as appendix ‘A’ (ii) Following items mentioned under srl no 1.01 to1.13 here-in after shall also be included in lump sum rate quoted against Srl item No 1 of BOQ. 2 Site clearance/site developments 3 Anti termite treatment 4 All primary structural components should be confirmed to IS: 2062 E-350 BR, Having a minimum tensile strength of 490 MPs and pass physical & Chemical tests stipulates therein 5 Purlins and side girt membersshall be made from cold Formed Sections, Confirming to IS : 811, having a minimum tensile strength of 345 MPs. The sheets used for cold forming sections shall confirm to IS : 1079, 2009 quality HR3 6 Permanently colour coated high tensile steel sheet havingminimum base metal thickness of 0.45mm (i.e excluding Aluminium -Zinc/galvanizing & colour coating thickness) & minimum Yield strength of 550 Mpa, coated with 55% Al-Zn alloy @ 150 g/Sqm as per ASTM A792M; Color coated with total minimum thickness of 40 microns (nominal) comprising of Silicon, Modified polyester (SMP with silicon content of 30% minimum) paint or super Polyester paint of minimum 20 microns (nominal) Dry Film Thickness (DFT) on exposed side over 5 microns (nominal) primer coat and 10 microns (nominal) approved colour Epoxy paint on other side over 5 microns (nominal) primer coat as per ASTM A755M 7 Kota stone flooring shall be 18 to 20 mm thick machine cut and polished at site after fixing (Mirror polish/granite polish). Size of Kota stone slabs used in floors shall be not less than 500 mm x 500mm.Kota stone slab shall be laid over 20mm thick screed in CM (1:6) over 100 mm thick PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate over rammed earth. Jointing shall be with grey cement mixed with pigment to match the shade of Kota stone slab. The floor shallachieve mirror finish surface. 8 75 mm thick PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as inplinth protection & Saucer drain. Plinth protection surface finishedeven and smooth without using extra cement of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) 9 Stainless steelrailingwith SS hand rail pipes grade 304 as perarchitectural drawing shall be provided. 10 10 to12 mm thick ready mix plaster on internal surface and external surface of wall. 11 Preparation of newly plaster surface of wall and applying two coats of synthetic enamel paint over a coat of primer on internal and external surface of wall. 12 Ramp provided same as per flooring specification 13 PAINTING SCHEME FOR STRUCTURAL STEEL WORK:(a) Soap paint :- One coat of inorganic zinc silicate primer-75 microns(b) Soap paint :- One coat of polyurethane paint -30 microns(c) Site paint :- One coat of polyurethane paint- 30 microns (after erection & fixing work) 14 Applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer on other than structural steel surface 15 INTERNAL ELECTRIFICATIONM&L for point wiring completeforOne light/Fan/Exhaust Fan/Bell point controlled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 Sqmm(nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 25 mm dia non metalic PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof / floor slab and ceiling, pressed GI concealed terminal modular boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including suitable cover plate of any module including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :-(i) In case of roof/ceiling, heavy duty PVC pipe not less than 25 mm dia shall be used without any extra cost.(ii) Height of socket should be 1.2m above from FFL 16 M&L for Point wiring completeforone 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insualted and unsheathed FRLSH CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 25 mm dia non metalic PVC conduit medium grade concealed in wall / roof / floor slab and ceiling, pressed GI concealed terminal modular boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :-(i)In case of roof/ceiling, heavy duty PVC pipe not less than 25 mm dia shall be used without any extra cost.(ii) Height of socket should be 1.2m above from FFL 17 M&L forPoint wiring completefor power point controlled by oneswitch with PVC insualted and unsheathed FRLSH cable 2.5 Sqmm(nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 25 mm dia non metalic PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /wall/ floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 2.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :- In case of roof/ceiling, heavy duty PVC pipe not less than 25 mm dia shall be used without any extra cost.One circuit controlled by max one points only. 18 S&F Switch piano, flush type 5 Amps single pole, one way complete all as specified and directed. 19 S&F Socket outlet, flush type 2 in 1, 5 pin, 5 Amps, multi-purpose complete all as speci-fied and directed. 20 S&F Switch piano, flush type single pole, one way 15 Amps complete all as specified and directed. 21 S&F Socket outlet, flush type 2 in 1, 5 pin, 5 and 15 Amps, multipurpose complete all as specified and directed. 22 S&F Ceiling rose, 3 to 4 ter-minals 65x50mm, PVC/ poly-carbonatebody, 240 Volt ISI marked complete all as specified and directed 23 S&F LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSIBin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification.complete all as specified and directed 24 S&FTPN DB 4 way double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete without MCCBand with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed by Engr in charge. 25 S&F MCB single pole 6 to 32 Amp rating C Series,10 KA240 Volts, AC50 Hz , ISI marked complete all as specified and directed . 26 S&F MCB TPN 63 Amp rating C Series,10 KA415 Volts, AC50 Hz , ISI marked complete all as specified and directed. 27 Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, class insulation B, 3 Nos blades, 30/40 Cm long down rod, 2 no canopy, shackle kit, safety rope, copper winding, power factor not less than 0.90 services value (CMM/W) minimum 6.0 Air delivery min 210 CMM, 350 RPM (tolerance as per IS: 3742019) THD less than 10 % without remote and electronic regulator unit for speed control and all remaining accessories including safety pin, nuts, bolts, washers, suitable for 230 V, 50 Hz single phase AC supply earthing etc and connecting up the fan to ceiling roseincluding PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceilingfan motor not less than 0.5 mtr long with PVC connector 2 way/3 wayfor connection and writing MES No. in black synthetic enamel paint/engraving tools etccomplete all as specified and directed.Note:- (a) T&P will be provided by the contractor for reaching any height of the building/warehouse/Hanger 28 M&L Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round baras in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.(ii) Earthing wire beyond 7.5m shall be measured and paid separately. 29 S&F LED Building security light fitting 35 Watt with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <20 W (35W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed. 30 EXTERNAL ELECTRIC SUPPLYExcavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth,laying of pipes & cable etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed 31 Returning filling in with approved excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. 32 Removing excavated material (soils) to a distance n.exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as specified and directed. 33 M&L for Sand cushioning to U/G cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, punned thickness shall be measured) in trenches com-plete all as specified and di-rected.Note: - Only punned thickness shall be measured and paid. 34 Supply and laying sub class ‘B’ bricks old sizeof size 230mmx115mmx75 mm for protection of LT under ground cable complete all as specified and directed 35 M&L for 40 mm dia galvanised steel tubing, light grade, with all necessaryfittings and fixtures laid in trenches, fixed to walls, poles, under road/floor etc for cable protection completeall as specified and directed. 36 Supply, laying, testing and commissioning of XLPE PVC insulated, PVC sheathed armoured LT 1100 volts heavy duty withaluminum conductor of size 25 sqmm 4 core passing through pipe, in duct, on poles, in trenchesincluding fixing hardware, clamps, making good the damaged surfaces etc, as required completeall as specified and directed.

Key Value

Document Fees
INR 1000 /-
EMD
INR 248000.0 /-
Tender Value
INR 1.72 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail