Repairing Of Mcc Panel With Supply And Installation Of Submersible Pumping Machinery Along With Other Allied Works At Eklavya Model Residential School, Mukutmonipur, Dist - Bankura Under B.M.D. Phe Dte., bankura-West Bengal

Public Health Engineering Department has published Repairing Of Mcc Panel With Supply And Installation Of Submersible Pumping Machinery Along With Other Allied Works At Eklavya Model Residential School, Mukutmonipur, Dist - Bankura Under B.M.D. Phe Dte.. Submission Date for this Tender is 01-08-2025. Submersible Pump Tenders in bankura West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

50241511
Repairing Of Mcc Panel With Supply And Installation Of Submersible Pumping Machinery Along With Other Allied Works At Eklavya Model Residential School, Mukutmonipur, Dist - Bankura Under B.M.D. Phe Dte.
Tender
Indian
West Bengal
Bankura
01-08-2025

Tender Documents

Tender Details

Repairing of MCC panel with Supply and installation of Submersible pumping machinery along with other allied works at Eklavya Model Residential school, Mukutmonipur, Dist - Bankura under B.M.D. PHE Dte.- 1 Detection of fault, dismantelling ofthe burnt out electrical spare, wire and others of the motor control panel, through cleaning and removing all damage materials from inside of the panel after disconnecting electrical lines with the engage of skilled electrician as per direction of EIC. 2 Supply and delivery of following spares part as per sample. 3 INCOMER: 4 MCCB, TMD, TP (WITH O/L, S/C TRIPS), 63A, 36kV 5 DIGITAL AMMETER 96 SQ. MM., 0-60A 6 DIGITAL VOLT METER 96 SQ. MM.,0-300V AC 7 CT 60/5A, 15VA, CL-1 TAPE WOUND, 60/5A 8 INDICATION LAMPS LED TYPE (R,Y,B,A), 230V 9 MCB, SP FOR CONTROL , 6A 10 EMERGENCY PUSH BUTTON, 10A 11 OUTGOING: 12 MCB, DP, 20A 13 BI-METALLIC THERMAL O/L RELAY, 13-19A 14 POWER CONTACTOR, 3P (MAIN), 25A 15 POWER CONTACTOR, 3P (FOR START CAP.) | 25A 16 ON DELAY TIMER, 230V AC , 3 Sec.-3 Hrs. 17 CAPACITOR, 230V AC (FOR START), 200MFD 18 CAPACITOR, 230V AC (FOR RUN), 100MFD 19 MCB, SP FOR CAPACITOR, 6A 20 NORMAL P.B SWITCH, GREEN, 10A 21 NORMAL P.B SWITCH, RED, 10A 22 AUTO/MANUAL SWITCH (1P, 2WAY), 10A 23 MCB, SP FOR CONTROL, 6A 24 MCB, DP FOR AREA LIGHT 32A 25 DP MCB 16A 26 POWER CONTACTOR, 3P 25A for light 27 INDICATING LAMPS LED TYPE (ON) 230V, R,G,A 28 Single core 2.5 sq.mm FRLS wire 29 Single core 4 sq.mm FRLS wire 30 Single core 6 sq.mm FRLS wire 31 Fitting fixing of above supplied item sl. no. 2.01 to 2.23 with servicing of whole MCCpanel, rewiring of the burntout control circuit and power circuit with the supply of necessary gauge of cu.wire, power termional etc. socketing all the leads properly for proper fitting by engaging skilled electrician including testing commissioning complete as per direction of EIC. 32 Supply and deliveryof clear water vertical wet type submersible pump suitable for bore well conforming to IS : 8034 ( and as amended there after ) with standard MOC for potable clear coldwater and capable, The pump shall be directly couprled with a continuous rated 2- pole suitable wet type verticalsquirel cage induction motor conforming to IS : 9283 (and as amended thereafter),suitable for operation in AC Three phases 415 V,50HZ (category B motor). Method of stating- DOL, Test certificate along with characteristic curve should be submitted at the time of delivery.Discharge: 1.3 m3/hr, Head: 115 Mtr. 33 Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 4 way 34 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 4 Way 35 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 36 FP : 32 Amp. 37 TP: 16 Amp. 38 Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit FR (Precision make) incl. necy. fittings as required. 39 3 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC 40 3 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC 41 Supply and delivery of Direct online starter for above supplied pump with fullowing specification: AC coil voltage: 260-440V, Relay range: 3.8 A to 6.0 Amp. 3 phase, Contactor: 20 Amp. With inbuild ammeter, voltmeter, selector switch, with single phase preventer. 42 Supply and delivery of 1.1KV grade 2.5 sq.mm x 3 core water proof flat submersible cable IS 694:2010 for above submersible pump.(Make: Approved Vendor list of PHED) 43 Supply and delivery of 1.1KV grade 4 sq.mm 3 core XLPE insulated Aluminium armoured cable conforming to IS 7098 (Part 1) 2011 with Up To Date Amendments.(Make: Approved Vendor list of PHED) 44 Supply and delivery of the followingpipes, valves and gauges etc at site:- 45 3 mtr long 40 mm dia UPVC standard type column pipe [cream color] with both side threaded and one end side socketed with registered KPMG. 46 40 mm dia. CI Top & Bottom adopter. 47 40 mm dia. GM Globe valve ISI Screwed End 48 40 mm dia. GM Check non return valve ISI Screwed End 49 40 mm dia. GI Elbo 50 40 mm GI Nipple 51 40 mm x 32 mm GI reducer 52 Split type MS fabricated suitable tubewell cover as per Pair tubewell housing with a necessary arrangement for clamping devices including holes for air pipe and cable entry gland. 53 Making CC foundation for support of the kiosk box after excavating the earth upto a depth of 0.6 Mtr below the GL including supply of all materials complete with 12 mm thick cement plastering with net cement finishing complete as per direction of EIC (size: 3 x 1 x 5) 54 Suitable Kiosk box for cable connection of submersible pump motor set with degree of protection IP 65 including suitable legs and 3 Nos. Al. Bus bar for 32 Amps and all necessary earthing arrangement and insulator as per direction of EIC. 55 Supply & Making necessary pvcSchedule 80 pipe (dia of pipe not less than 32mm) protection for submersible cable from kiox box to submersible pump-motor set including supply of all specials and complete the job including labour charges of earth cutting (where necesary) minimum 760 mm depth from GL. 56 Installation of Submersible pumping machinery to newly sunk tubewell along with column pipes (as required), top cover, valves, and specials of above with protection pipe and supply of MS clamp, nut bolt, cable gland socket etc. making inerconnection of the pump delivery line to pump collecting main line near tubewell with supply of all necceasary pipe, reducer/enlarger, GI/MS specials etc. including brick, sand, cement, rod etc and laying & fitting fixing of starter with necessaery earthing with drawing of power cable from starter & cable protection pipe as required and all to complete the job including all connection & testing commissioning as per direction of EIC. 57 Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. PVC Pipes 58 Dia: 40 mm 59 Dia: 32 mm 60 Supply and fitting fixing of CPVC Ball valve 61 Dia: 40 mm 62 Dia: 32 mm 63 Add: 18% GST 64 Add: 1% Cess

Key Value

Document Fees
Refer document
EMD
INR 24000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail